N106DA

ENSTROM HELICOPTER CORP 280C · 1976 · Rotorcraft · 1 engine · 3 seats · Valid Registration

Registered owner: BEARTOOTH FENCING LLC, MT (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

BOEING 767-232 No injuries Part 121operator not named in the NTSB record
Source: NTSB case NYC87IA202

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

29 reports on file, 1995-05-10 – 2004-12-25.

SMOKE/FUMES/ODORS/SPARKS · 2004-12-25 Matched by certificate designator
ATA 2121

Part: COOLING FAN — MALFUNCTIONED (E/E BAY) · airframe 66,471 hrs · 32,318 cycles

FWD EQUIPMENT COOLING FAN MESSAGE WITH SMELL. REPLACED SAME.

Source: SDR DL767041140
FALSE WARNING · 2004-12-16 Matched by certificate designator
ATA 2612

Part: CIRCUIT CARD — INTERMITTENT (FIRE WARNING) · airframe 66,390 hrs · 32,285 cycles

INTERMITTENT FWD CARGO FIRE LIGHT PLUS BELL CAME ON DURING TAXI IN. REPLACED FIRE CARD M10427 IN P-54 PANEL. SYSTEM CHECKS NORMAL PER M/M. PER CVG FIRE DEPT, NO EVIDENCE OF SMOKE, ODOR, OR FIRE FOUND.

Source: SDR DL767041108
Earlier reports · 1995–2002 · 27 reports

2002

FALSE WARNING · 2002-10-28 Matched by certificate designator
ATA 5270

Part: SENSOR — INTERMITTENT (EMERGENCY EXIT) · airframe 63,009 hrs · 30,630 cycles

FT EMER DOOR LIGHT COMES ON INTERMITTENTLY IN FLIGHT. BITE CKD PSEU HAD PREVIOUS SENSORS 193 AND 192 TARGET FAULTS. NO PRESENT FAULTS. SENSOR 192 TARGET TEST OK. VISUALLY INSPECTED DOOR INTERIOR MECHANISM AND EXTERIOR PER M/M 52-21-02-2, FOUND OK.

Source: SDR DL767021259

2001

FLUID LOSS · 2001-09-02 Matched by certificate designator
ATA 3200

Part: HYDRAULIC LINE — BLOWN (RT PYLON) · airframe 59,771 hrs · 28,993 cycles

RT HYD SYSTEM PRESSURE LOST DUE TO LEAK. FLUID DECREASES RAPIDLY WHEN DEMAND PUMP IS ON. - REPLACED EDP DISCHARGE LINE

Source: SDR DL767011464
FLUID LOSS; WARNING INDICATION · 2001-08-23 Matched by certificate designator
ATA 2912

Part: MODULE — CRACKED (HYDRAULIC SYS) · airframe 59,702 hrs · 28,955 cycles

ON HYD START UP LOST ALL CENTER SYSTEM FLUID. FOUND PRESS FILTER BOWL CRACKED AND SEPARATED FROM C1 ACMP PRESSURE/CASE DRAIN FILTER MODULE. REPLACED SAME MODULE PER M/M, CHECKS NORMAL, NO LEAKS.

Source: SDR DL767011392
SMOKE/FUMES/ODORS/SPARKS; WARNING INDICATION · 2001-08-14 Matched by certificate designator
ATA 2121

Part: FAN — DEFECTIVE (MANIFOLD BAY) · airframe 59,621 hrs · 28,918 cycles

DURING APPROACH SMOKE PRESENT IN COCKPIT. SHORTLY AFTER THE LEFT RECIRC FAN EICAS MSG APPEARED. TURNED LEFT RECIRC FAN OFF. SMOKE DID DISSIPATE AFTER LDG. CONTRACT MTC FOUND THE LEFT RECIRC FAN C/B IN, BUT POPPED WHEN BARELY TOUCHED. ALSO C/B WAS VERY HOT TO THE TOUCH. REPLACED RECIRC FAN

Source: SDR DL767011335
OTHER · 2001-05-18 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 58,861 hrs · 28,556 cycles

CORROSION FOUND ON THE STA 1480 FLOORBEAM AT THE RT O/B FRAME ATTACHMENT LOCATION AND AT RBL 72 AFT UPPER FLANGE. ER/A 397554-14.

Source: SDR DL767010818

2000

NO TEST · 2000-07-30 Matched by certificate designator
ATA 3350

Part: CIRCUIT BOARD — FAILED (COCKPIT) · airframe 56,451 hrs · 27,534 cycles

DURING ROUTINE MAINT FOUND COCKPIT EMERGENCY LIGHT ILLUMINATING DURING POWER DOWN. REPLACED CIRCUIT CARD.

Source: SDR DL767001436

1999

WARNING INDICATION · 1999-10-13 Matched by certificate designator
ATA 3240

Part: SWITCH — INOPERATIVE (BRAKE)

ABORTED T/O DUE TO T/O CONFIG HORN, PARKING ON EICAS PARKING BRAKE HANDLE WAS DOWN. REPLACED PARKING BRAKE SWITCH PER M/M 32-44-08 TEST OK PER M/M AND PERFORMED T/O CONFIG TEST, ALL OPS CKS OK.

Source: SDR DL767992269
NO TEST · 1999-08-15 Matched by certificate designator
ATA 3350

Part: EMER EXIT LIGHT — INOP (COCKPIT)

FOUND COCKPIT EMERGENCY LIGHT OVER DOOR INOP.

Source: SDR DL767991843
NO TEST · 1999-06-27 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

AFT CABIN EMERGENCY LIGHTS INOP ON L/O TEST. REPLACED POWER SUPPLY AND CHARGER, SYSTEM CHECKS NORMAL.

Source: SDR DL767991452

1998

OTHER · 1998-11-11 Matched by certificate designator
ATA 5754

Part: WEDGE — DELAMINATED (NR 6 LE SLAT)

THE UPPER SKIN OF THE TRAILING EDGE WEDGE ON THE NR 6 SLAT WAS FOUND WITH A 5 X 4 AREA OF DELAMINATION APPROXIMATELY 62 INCHES FROM THE O/B EDGE OF THE SLAT. THE DAMAGE WAS TRIMMED AWAY AND REPAIRED PER THE B767 SRM 51-70-10 AND DOCUMENTED PER ER/A 366072-14AD.

Source: SDR DL767982344
NO TEST · 1998-09-11 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

MSU T/S EMERGENCY LIGHT PROBLEM. FOUND M735 BATTERY CHARGER BAD. REPLACED CHARGER AND BATTERY PACK. CKS NML.

Source: SDR DL767981889
OTHER · 1998-04-11 Matched by certificate designator
ATA 5310

Part: STRUCTURE — CORRODED (BS 430)

FUSELAGE STRINGERS 36L TO 33R WERE FOUND CORRODED BETWEEN FS 412 AND 456. NEW SECTIONS OF STRINGER WERE SPLICED IN PER SRM OR LONGER BLUEPRINT STRINGER SPLICES WERE INSTALLED. A SMALL SECTION OF SKIN WAS CORRODED AND CUTOUT. THE SKIN WAS REPAIRED PER THE B767 SRM. THE OVERALL REPAIR WAS DOCUMENTED AND INSTALLED PER ER/A 364467-14, REV A. LIAISON ENGR'G DETERMINED THAT SPILL IN B/B WAS CAUSE AND THEREFORE AN ISOLATED INCIDENT.

Source: SDR DL767980799

1997

FLUID LOSS; WARNING INDICATION · 1997-09-29 Matched by certificate designator
ATA 2910

Part: HOSE — CHAFFED (NR 2 ENGINE)

APPROX 30 MIN AFTER ENGINE START-R HYD SYS QTY EICAS MSG. SELECTED STATUS PAGE AND RT HYD QTY SHOWED .05. S/O RT PRIMARY AND DEMAND PUMP OFF. FOUND ENG HYD PUMP PRESS HOSE WORN THROUGH. HOSE WAS RUBBING BRACKET BOLT HEAD JUST BELOW TOP GANG CLAMP. REPLACED LINE AND REPOSITION TO PREVENT RUBBING, REF IPC 29-11-51-10 ITEM 255.

Source: SDR DL767971914
NO TEST · 1997-08-26 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

LEFT CENTER BY MID GALLEY OVERHEAD EMERGENCY LIGHTS INOP. REPLACED POWER SUPPLY, OPS CHECKS NORMAL.

Source: SDR DL767971668
NO TEST · 1997-08-26 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

FWD MOST 4 RT OVERHEAD EMERGENCY LIGHTS INOP. REPLACED POWER SUPPLY, SYSTEM OPS CHECK NORMAL.

Source: SDR DL767971666
NO TEST · 1997-08-26 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

RT SIDE OUTSIDE EMERGENCY LIGHTS INOP. REPLACED POWER SUPPLY, CHECKS NORMAL.

Source: SDR DL767971667
NO TEST · 1997-08-26 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

AFT LT 3 OUTSIDE EMERGENCY LIGHTS INOP. REPLACED POWER SUPPLY, OPS CHECK NORMAL.

Source: SDR DL767971665
SMOKE/FUMES/ODORS/SPARKS · 1997-08-20 Matched by certificate designator
ATA 2422

Part: INVERTER — FAILED (E/E COMPT)

FL 390 EN ROUTE TO KSFO, FIRST HAD A STATUS MESSAGE STANDBY INVERTER, FOLLOWED BY A BURNING SMELL AND THEN HEAVY SMOKE, FOLLOWED SMOKE REMOVAL CHECKLIST AND DIVERTED INTO KLAS. FOUND STATIC INVERTER FAILED, REPLACED SAME. PERFORMED TEST PER MM. ALL OPS NORMAL EICAS MSGS CLEARED.

Source: SDR DL767971631
NO TEST · 1997-01-15 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

EMERGENCY LIGHT AFT OF C2 CARGO DOOR INOP. RELAMPED, OPS CHECKS NORMAL.

Source: SDR DL767970066
INFLIGHT SEPARATION · 1997-01-13 Matched by certificate designator
ATA 5730

Part: PANEL — MISSING (LT WING/FUS)

LT WING TO FUSELAGE PANEL 195CL MISSING MOST SCREWS STILL IN NUTPLATES. PANEL MUST HAVE LEFT INFLIGHT. FOUND DURING LTTR CK. MFG PANEL TREATED AND PAINTED AND INSTALLED PER ERA NR 360958-14.

Source: SDR DL767970060

1996

OTHER · 1996-02-05 Matched by certificate designator
ATA 2710

Part: BEARING — FAILED (AILERON CONTROL)

ON PREFLIGHT FLIGHT CONTROL CHECK, AILERON VERY STIFF TO MOVE ON BOTH PILOT CONTROL COLUMNS. FOUND BAD BEARING IN CENTERING MECHANISIM IN LEFT WHEEL WELL. REPLACED BEARING, OPERATION CHECK NORMAL.

Source: SDR DL767960286
FALSE WARNING · 1996-01-22 Matched by certificate designator
ATA 3260

Part: SENSOR — MALFUNCTIONED (NLG)

RETRACTING FLAPS TO UP POSITION AFTER T/O, THE FLAPS AND CONF LIGHT ILLUM WITH ASSOCIATED WARNING. STATUS MSG NOSE A/G DISAGREE STATUS MSG APPEARED. A/C WAS A ATB DUE TO STATUS MSG, NOSE A/G DISAGREE. REPLACED S266 NOSE GEAR COMPRESSED SENSOR.

Source: SDR DL767960149
NO TEST · 1996-01-20 Matched by certificate designator
ATA 3350

Part: BULB — FAILED (RT OVERWING)

RT OVERWING EMERGENCY LIGHT INOP. RELAMPED AND CLEANED CONTACT.

Source: SDR DL767960139

1995

OTHER · 1995-12-31 Matched by certificate designator
ATA 5320

Part: FAIL-SAFE CHORD — CORRODED (FS 1540)

THE FUSELAGE RT SIDE AFT PASSENGER DOOR LOWER SILL INNER CHORD WAS FOUND WITH DEEP CORROSION ON THE ATTACHED FAIL-SAFE CHORD AT FS 1540. THE CORROSION IS OF DEPTH REQUIRING CUT OUT. THE CORROSION WILL BE REPAIRED IN ACCORDANCE WITH REF ER/A272246 REV C.

Source: SDR DL767960375
OTHER · 1995-11-05 Matched by certificate designator
ATA 5712

Part: RIB — CRACKED (WS 716)

NR 2 SPOILER ACTUATOR OUTBOARD SUPPORT RIB AT WS 716 CRACKED IN HALF, IPC 57-11-53-03, ITEM 715. REPLACED RIB.

Source: SDR DL767954412
OTHER · 1995-05-15 Matched by certificate designator
ATA 5753

Part: SKIN — DELAMINATED (LT TE FLAP)

PREVIOUS REPAIR TO I/B LOWER SURFACE ON O/B FLAP IS DELAMINATED. WHEN DAMAGED AREA WAS REMOVED, WATER WAS FOUND. ACCOMPLISHED REPAIRS PER SRM 57-53-01.

Source: SDR DL767952290
OTHER · 1995-05-10 Matched by certificate designator
ATA 5751

Part: SKIN — DAMAGED (LT AILERON)

INBOARD END OF OUTBOARD AILERON HAS CONDENSATION ON LOWER SKIN SURFACE, DUE TO WATER INGESTION. ACCOMPLISHED REPAIRS PER SRM 57-60-02. FOUND AT LETTER CHECK.

Source: SDR DL767952038