N108DL

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

BOEING B767-232 No injuries Part 121operator not named in the NTSB record
Source: NTSB case FTW85IA221

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

47 reports on file, 1995-03-20 – 2004-03-08.

OVER TEMP · 2004-03-08 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (LT WING) · airframe 65,853 hrs · 32,043 cycles

MCO LEFT WING ILLUMINATION LIGHT INOP. FOUND LIGHT ASSY TERMINAL BOARD BROKEN AND WIRES DAMAGED WITH EVIDENCE OF ARCING. NDS NEW ASSY TO INCLUDE TERMINAL BLOCK NOT SHOWN IN IPC. NDS MFG P/N 30-1543-1. NASI DAL, PULLED AND COLLARED C/B N-35 WING ILLUM ON P11-6 C/B PANEL. MCO SOB. MCO DOCUMENTED AS MRR.

Source: SDR DL767040222
NO TEST · 2004-02-15 Matched by certificate designator
ATA 3350

Part: FUSE — BLOWN (EMERGENCY LIGHT) · airframe 65,716 hrs · 31,979 cycles

ON MAINTENANCE PREFLIGHT INSPECTION FOUND FIRST CLASS EMERGENCY LIGHTS INOP IN THE SEAT PANELS. TROUBLESHOOTING FOUND BLOWN FUSE IN POWER SUPPLY M9008. REPLACED FUSE, LIGHTS NOW OPERATIONAL CHECK OK.

Source: SDR DL767040158
SMOKE/FUMES/ODORS/SPARKS · 2004-01-31 Matched by certificate designator
ATA 2121

Part: FAN — FAILED (RIGHT) · airframe 65,613 hrs · 31,930 cycles

IN FLIGHT THE CREW REPORTED, GOT A RT RECIRC FAN INOP LIGHT ACCOMPANIED BY A STRONG PUNGENT ODOR. THE ODOR WENT AWAY WHEN BOTH RECIRC FANS WERE TURNED OFF. ALSO PULLED THE CIRCUIT BREAKER FOR THE RT RECIRC FAN. THE LT RECIRC FAN OPERATED NORMALLY ON THE GROUND AND THE RT RECIRC FAN WAS PUT ON MCO PER MEL 21-25-01A. RT RECIRC FAN WAS REPLACED IN BDL ON 020104 REF LOG E638468 ITEM 003.

Source: SDR DL767040123
OTHER · 2004-01-30 Matched by certificate designator
ATA 5753

Part: FITTING — CORRODED (TE FLAPS) · airframe 65,604 hrs · 31,928 cycles

WHILE ACCOMPLISHING BOLT REPLACEMENTS FOR THE INBOARD FLAP SUPPORT FITTINGS ON THE LT & RT WINGS PER AD 2002-22-07, SEVERAL FITTING HOLE BORES WERE FOUND WITH CORROSION. THE HOLE BORES WERE OVERSIZED TO REMOVE ALL CORROSION, HFEC INSPECTED, AND BUSHED. NEW BOLT HOLES WERE THEN REAMED AND THE NEW BOLTS INSTALLED. THE REPAIRS WERE PER ER/A'S 088285, 088313, 088286, 088287 & 088289-14.

Source: SDR DL767040128
Earlier reports · 1995–2003 · 43 reports

2003

NO TEST · 2003-08-13 Matched by certificate designator
ATA 3350

Part: FUSE — BLOWN (EMERGENCY LIGHT) · airframe 64,652 hrs · 31,445 cycles

EXTERNAL EMERGENCY LIGHTS AFT OF RT OVERWING EXIT INOP (2ND & 3RD) FOUND FUSE BLOWN IN EMERGENCY BATTERY CHARGER RECEPTACLE. REPLACED SAME. LIGHTS OPERATE NORMAL.

Source: SDR DL767030751
NO TEST · 2003-07-06 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 64,398 hrs · 31,310 cycles

FOUND F/C EMERGENCY PATH LIGHTS INOPERATIVE. REMOVED AND REPLACED M9008 BATTERY PACK. OPS CHECK NORMAL.

Source: SDR DL767030615
SMOKE/FUMES/ODORS/SPARKS · 2003-03-17 Matched by certificate designator
ATA 2150

Part: A/C PACK — MALFUNCTIONED (A/C BAY) · airframe 63,693 hrs · 30,922 cycles

AFTER TAKEOFF, STRONG ELECTRICAL SMELL IN COCKPIT AND FLT ATT REPORTED ELECTRICAL SMELL AND SMOKE IN CABIN. INSPECTED RT PACK BAY, NORMAL RAN PACK USING APU AIR, TURBINE INLET TEMP ROSE HIGH. NO OVENS IN USE DURING TAKEOFF. RAN GASPER AND RECIRC FANS, OPS NORMAL. FWD RT PACK TO MCO AND PLAC PER MEL 21-51-01A.

Source: SDR DL767030249
NO TEST · 2003-02-19 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 63,496 hrs · 30,817 cycles

EXTERIOR EMERGENCY LIGHT LT SIDE STA 1240 INOPERATIVE. RELAMPED,NO HELP. SUSPECT POWER SUPPLY. REPLACED FUSES IN POWER SUPPLY, LIGHT CHECK GOOD.

Source: SDR DL767030165

2001

NO TEST · 2001-12-15 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 60,336 hrs · 29,203 cycles

DURING SVC CHECK LEFT FIRST CLASS OVERHEAD EMERGENCY LIGHTS INOP. REPLACED BATTERY PACK, SYSTEM CHECKS GOOD.

Source: SDR DL767011942
NO TEST · 2001-09-15 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 59,628 hrs · 28,825 cycles

EMERGENCY LIGHT INOP 5L POS. REPLACED LIGHT.

Source: SDR DL767011538
NO TEST · 2001-09-15 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 59,628 hrs · 28,825 cycles

OVERHEAD EMERGENCY LIGHTS IN F/C INOP. REPLACED BATTERY PACK IN FIRST CLASS LEFT SIDEWALL, CHECK GOOD.

Source: SDR DL767011539
FLUID LOSS · 2001-08-27 Matched by certificate designator
ATA 2900

Part: COUPLING — BROKEN (ADP PRESS LINE) · airframe 59,497 hrs · 28,766 cycles

LNDG IN JAX "CTR HYD QTY" EICAS MSG ILLUMINATED. TURNING ONTO TAXIWAY, QTY WENT FROM 4.0 TO 0.0 AND LOST NOSEWHEEL STEERING. TOWED INTO GATE. LEFT AND RIGHT HYD SYSTEMS NORMAL. CA FD COUPLING BETWEEN ADP ASSY AND PRESS LINE BROKEN. REPLACED COUPLING PER MM.

Source: SDR DL767011418
NO TEST · 2001-08-22 Matched by certificate designator
ATA 2560

Part: FLASHLIGHT — INOPERATIVE (CABIN) · airframe 59,454 hrs · 28,744 cycles

AFT RT CABIN FLASHLIGHT INOP. REPLACED FLASHLIGHT ASSY AND BATTERY CHECK GOOD.

Source: SDR DL767011384
OTHER · 2001-08-10 Matched by certificate designator
ATA 5320

Part: FITTING — CRACKED (FUSELAGE) · airframe 59,375 hrs · 28,705 cycles

CRACK INDICATIONS FOUND IN THE STA 1809 BULKHEAD COMMON TO THE SPLICE FITTING, FWD OUTER CHORD AND LONGERON FITTING.

Source: SDR DL767011326
OTHER · 2001-08-10 Matched by certificate designator
ATA 5312

Part: BULKHEAD — CRACKED (FUSELAGE) · airframe 59,375 hrs · 28,705 cycles

CRACKS FOUND IN THE STA 1809 BULKHEAD AREA, COMMON TO THE SKIN AND THE FWD OUTER CHORD, LT SIDE OF AIRCRAFT.

Source: SDR DL767011325
OTHER · 2001-08-10 Matched by certificate designator
ATA 5412

Part: BULKHEAD — CRACKED (NR 1 PYLON) · airframe 59,375 hrs · 28,705 cycles

DURING ACCOMPLISHMENT OF PYLON SIP MODIFICATION,CRACK INDICATIONS WERE FOUND IN THE MID STRUT BULKHEAD IN AREA COMMON TO THE UPPER SPAR FITTING.

Source: SDR DL767011324
OTHER · 2001-04-30 Matched by certificate designator
ATA 2560

Part: BRACKET — DAMAGED (OVERHEAD BIN) · airframe 58,661 hrs · 28,383 cycles

ON L/O FOUND 1ST CLASS MEGAPHONE AND MEGAPHONE BRACKET DAMAGED. REPLACED 1ST CLASS MEGAPHONE AND MEGAPHONE BRACKET PER M/M. FOUND BRACKET TO HAVE FAULTY LATCH RESULTING IN AN UNSECURE MEGAPHONE WHICH FELL FROM THE OVERHEAD BIN AND WAS DAMAGED.

Source: SDR DL767010692
NO WARNING INDICATION · 2001-03-08 Matched by certificate designator
ATA 3260

Part: BULB — BURNED OUT (MLG INDICATOR) · airframe 58,207 hrs · 28,188 cycles

LT MAIN LANDING GEAR NOT INDICATING GREEN WHEN LANDING GEAR IS DOWN AND LOCKED. RELAMPED LT MAIN GEAR DOWNLOCK GREEN LITE RECONFIGED A/C TO NORM GEAR MODE ALL CKS OK

Source: SDR DL767010383

2000

OTHER · 2000-08-30 Matched by certificate designator
ATA 5330

Part: SKIN — DENTED (BS643, S28R) · airframe 56,435 hrs · 27,395 cycles

A DENT WAS FOUND IN THE FUSELAGE SKIN AT STRINGER 28R, BETWEEN BS 632 AND 654. TO REMOVE DENT THE SKIN WAS CUT OUT, TO A SIZE OF 3.5 BY 5.5 INCH. SKIN DAMAGE WAS REPAIRED PER ERA 378344-14.

Source: SDR DL767001674
NO TEST · 2000-05-07 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (CABIN) · airframe 55,365 hrs · 26,936 cycles

RT EMERGENCY CEILING LIGHT AT ROW 13 TO FWD ENTRY DOOR INOP. REPLACED BATTERY PACK, OPS NORMAL.

Source: SDR DL767000915
NO TEST · 2000-04-01 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (PAX DOOR) · airframe 55,007 hrs · 26,775 cycles

DURING LAYOVER, FOUND R1 DOOR EMERGENCY LIGHT INOP. REPLACED CHARGER, CHECKS GOOD PER MM.

Source: SDR DL767000612

1999

NO TEST · 1999-12-17 Matched by certificate designator
ATA 2565

Part: BATTERY — DISCHARGED (SLIDE)

DURING SQUIB TEST, LT ESCQPE SLIDE DID NOT ILL WHILE PRESSING TEST 1 AND RT ESCAPE SLIDE DID NOT ILL WHILE PRESSING TEST 2. REPLACED LT OVERWING SLIDE POWER SUPPLY AND BATTERY. OPS CHECK NORMAL.

Source: SDR DL767992832
NO TEST · 1999-12-12 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

DURING LAYOVER, FOUND NR 1 SQUIB TEST INOP. LEFT OVERWING ESCAPE SLIDE. REPLACED BATTERY AND BATTERY PACK, OPERATION NOW NORMAL.

Source: SDR DL767992718
OTHER · 1999-09-30 Matched by certificate designator
ATA 5730

Part: SKIN — CORRODED (CENTER WING)

CORROSION WAS FOUND ON THE WING CENTER SECTION UPPER SKIN AREA BETWEEN LBL 67 AND 90. THE WING SKIN WAS CORRODED ABOVE STRINGERS U-1 AND U-2 AND AT THE REAR SPAR. ADDITIONALLY, THERE WAS CORROSION DAMAGE TO THE REAR SPAR CAP, PRESSURE DECK WEB AND PRESSURE DECK ATTACH ANGLE. TO GAIN ACCESS TO ALL CORRODED AREAS, THE LBL 74.81 LONGTUDINAL FLOORBEAM LOWER CHORD WAS CUT FWD OF STRINGER U-2.

Source: SDR DL767992178
OTHER · 1999-09-28 Matched by certificate designator
ATA 5755

Part: SKIN — DELAMINATED (NR 4 SPOILER)

LT WING NR 4 SPOILER, 12 IN X 17 IN UPPER SKIN TO CORE DELAMINATION LOCATED IN CENTER OF PANEL. AUTHORIZED WET LAYUP, 180 DEG F CURE REPAIR.

Source: SDR DL767992311
OTHER · 1999-09-17 Matched by certificate designator
ATA 5400

Part: BRACE — CORRODED (NR 1 & 2 PYLON)

MIGRATED/ROTATED BUSHINGS WERE FOUND IN THE FORWARD LUGS OF THE NR 1 AND NR 2 PYLON DIAGONAL BRACES DURING PYLON INSTALLATION. MINOR CORROSION DAMAGE AND FRETTING DAMAGE WAS FOUND IN THE BORES UPON BUSHING REMOVAL.

Source: SDR DL767992171
OTHER · 1999-09-15 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 1465)

CORROSION DAMAGE WAS NOTED ON THE 146T3231-1 SKIN AT STA 1465 STRINGERS S-27L, S-28L AND 33L. CORROSION DAMAGE WAS ALSO FOUND ON THE 146T8220-1 BULK CARGO LOWER BEAR STRAP AT STA 1461 BETWEEN S-25L AND 26L.

Source: SDR DL767992179
OTHER · 1999-08-15 Matched by certificate designator
ATA 5320

Part: SPLICE — CORRODED (BS 434)

STRINGER 33L SPLICE WAS FOUND CORRODED AT STA 434, SPLICE WAS REPLACED PER DWG 140T0110 AND SRM 53-00-03-2-202.

Source: SDR DL767992033
OTHER · 1999-08-15 Matched by certificate designator
ATA 5320

Part: BLKHD CHORD — CORRODED (BS 1065)

THE PN 146T2003-2 CHORD WAS FOUND CORRODED ON THE AFT SIDE OF THE STA 1065 BULKHEAD AT A PRIMARY ATTACH FITTING AT STRINGER 23R. THE CHORD WAS REPLACED PER DWG 146T2000; NO DAMAGE TO ATTACHING STRUCTURE WAS FOUND.

Source: SDR DL767992029
OTHER · 1999-08-15 Matched by certificate designator
ATA 5320

Part: SPLICE — CORRODED (BS 434)

STRINGER 38L SPLICE WAS FOUND CORRODED AT STA. 434 AND WAS REPLACED PER DWG 140T0110 AND SRM 53-00-03-2-202.

Source: SDR DL767992035
OTHER · 1999-08-15 Matched by certificate designator
ATA 5320

Part: SPLICE — CORRODED (BS 434)

STRINGER 32R SPLICE WAS FOUND CORRODED AT STA 434, SPLICE WAS REPLACED PER DWG 140T0110 AND SRM 53-00-3-2-202.

Source: SDR DL767992032
OTHER · 1999-08-15 Matched by certificate designator
ATA 5320

Part: SPLICE — CORRODED (BS 434)

STRINGER 39L SPLICE WAS FOUND CORRODED AT STA 434 AND WAS REPLACED PER DWG 140T0110 AND SRM 53-00-03-2-202.

Source: SDR DL767992036
OTHER · 1999-08-15 Matched by certificate designator
ATA 5320

Part: SPLICE — CORRODED (BS 434)

STRINGER 37L SPLICE WAS FOUND CORRODED AT STA 434 AND WAS REPLACED PER DWG 140T0110 AND SRM 53-00-03-2-202.

Source: SDR DL767992037
OTHER · 1999-08-15 Matched by certificate designator
ATA 5320

Part: SPLICE — CORRODED (BS 434)

STRINGER 35L SPLICE WAS FOUND CORRODED AT STA 434 AND WAS REPLACED PER DWG 140T0110 AND SRM 53-00-03-2-202.

Source: SDR DL767992034
SMOKE/FUMES/ODORS/SPARKS · 1999-06-29 Matched by certificate designator
ATA 3454

Part: VOR — MALFUNCTIONED (RIGHT)

AT THE GATE CREW SMELLED ELECTRICAL ODOR AND SOME SMOKE. A/C WAS DEPLANED. MTC INVESTIGATED FOUND NO OBVIOUS PROBLEM BUT DID FIND VOR/MARKER C/B A-1 POPPED. SWAPPED LT VOR TO RT VOR POSTION AND THEN DEACTIVATED RT VOR PER MEL. A/C FLEW TO ATL. MTC REPLACED NR 2 VOR CONTROL PNL AND XCVR.

Source: SDR DL767991464

1998

FLUID LOSS; WARNING INDICATION · 1998-05-18 Matched by certificate designator
ATA 7200

Part: ENGINE — FAILED (NR 2)

IN DESCENT, NR 2 ENG SHOWED NO OIL QTY AND 10 PSI PRESS. SHUT DOWN ENGINE PER POM. MAINTENANCE IN PROGRESS. FOUND METAL ON CHIP DETECTOR, REPLACED ENGINE.

Source: SDR DL767981067
OTHER · 1998-02-10 Matched by certificate designator
ATA 5330

Part: SKIN — DENTED (BS 1351)

THE FUSELAGE SKIN WAS BADLY DENTED AT FS 1351 NEAR STRINGER 31R (JUST AFT OF THE C2 DOOR CUTOUT). THE UNDERLYING FRAME WAS ALSO DENTED. THE DAMAGED FRAME WAS REPAIRED PER THE B767 SRM 71-70-11. THE DENTED SKIN WAS CUTOUT AND REPAIRED WITH AN ALUMINUM DOUBLER AND TRIPLER PER ER/A 363959-14, REV A.

Source: SDR DL767980380

1997

OTHER · 1997-07-02 Matched by certificate designator
ATA 5330

Part: SKIN — CORROSION (BS 1307-1380)

THE SECTION 46 FUSELAGE SKIN BETWEEN STR 35L AND 36L HAS 3 DISTINCT AREAS OF SEVERE CORROSION THROUGH THE SKIN RESULTING IN .5 DIA HOLES. DAMAGE LOCATIONS ARE 1338, 1363, 1380 AN EXISTING REPAIR ST FS 1389 BETWEEN SUBJECT STR WILL BE REMOVED AND THE DAMAGE INCORPORATED INTO THE NEW REPAIR. ADDITIONAL DAMAGE WAS FOUND TO ANOTHER REPAIR LOCATED NEARBY. ALL DAMAGE LOCATED ARE NOW REPAIRED BY ON REPAIR. THIS REPAIR IS APPROVED PER FAA/DER FORM 8110-3, DER DESIGNATION SO-867, DTD 7-1-97.

Source: SDR DL767971331
OTHER · 1997-07-02 Matched by certificate designator
ATA 5730

Part: SKIN — CORROSION (BS 950-955)

DURING ACCOMPLISHMENT OF EO 1-60000-3, CORROSION WAS FOUND ON THE UPPER SURFACE OF THE CENTER SECTION UPPER WING SKIN AT APPROXIMATELY FS 950 TO 955 AND RBL 65 TO 80. THE DEEPEST CORROSION WAS FOUND DIRECTLY UNDER THE DRAIN SCREEN LOCATED AT APPROX RBL 70. THE AREA WAS CUT OUT AND BLENDED. CORROSION WAS ALSO FOUND ON THE EXPOSED SURFACE OF THE UNDERLYING REAR SPAR CAP. THE RBL 74.81 FLOORBEAM LOWER CHORD WAS CUT TO FACILITATE INSTALLATION OF THE REPAIR DOUBLERS. THIS REPAIR WAS APPROVED BY FAA DER FORM 8110-3, DER DESIGNATION SO-889, DTD 7-1-97.

Source: SDR DL767971325
OTHER · 1997-06-25 Matched by certificate designator
ATA 5730

Part: SKIN — CORROSION (WING CTR SECTION)

CORROSION WAS DISCOVERED ON THE WING CENTER SECTION UPPER SKIN, TOP SURFACE, BETWEEN STR U-15 TO THE AFT SPAR AND RBL 75 TO 95. THE CORROSION CONCENTRATED AROUND THE STRINGER TO SKIN FASTENER HOLES ABOVE THE AFT SPAR AND STR 3 TO 8, 11, 12 AND 15. THE FASTENER HOLES WERE SPOTFACED WITH A MAX DEPTH OF 0.072 AND COUNTERSINK WASHERS WERE INSTALLED.

Source: SDR DL767971326
WARNING INDICATION; ELECT. POWER LOSS-50 PC · 1997-04-28 Matched by certificate designator
ATA 2421

Part: IDG — FAILED (NR 1 ENGINE)

ON TAKEOFF, LOST 'L' GEN FOLLOWED BY AC L BUS OFF. STARTED APU DID NOT GET L BUS BACK. FOLLOWED BY 'L' GEN DRIVE LIGHT. APU WAS RUNNING OK. NO ISOLATION LIGHT. REPLACED NR 1 IDG AND GARLOCK SEAL. OPS CHECK GOOD. BPCU FAULTED LT GCU, REPLACED GCU. CHECKS GOOD. REPLACED BPCU DUE TO COFFEE STAINS ON UNIT. SYSTEM ALL CHECKS NORMAL.

Source: SDR DL767970788

1995

NO TEST · 1995-10-27 Matched by certificate designator
ATA 3350

Part: EEL POWER SUPPLY — FAILED (CABIN)

ON LAYOVER, FOUND 3 EXIT SIGNS EMERG LIGHTS INOP, MID-CABIN, RT SIDE. REPLACED POWER SUPPLY. OPERATION NORMAL.

Source: SDR DL767954120
NO TEST · 1995-09-22 Matched by certificate designator
ATA 3350

Part: EEL TRACK — INOP (CABIN)

DURING LAYOVER, EMERGENCY TRACK LIGHT DAMAGED NEAR AFT LEFT LAV. FOUND WIRE BROKEN UNDER TRACK. REPAIRED WIRES, OPS CHECK NORMAL.

Source: SDR DL767953796
NO TEST · 1995-09-11 Matched by certificate designator
ATA 3350

Part: EEL BULB — FAILED (CABIN)

LEFT AFT ENTRY DOOR EMER SLIDE LIGHT INOP. REPLACED LAMP AND CLEANED LIGHT ASSY, CHECK'S NORM.

Source: SDR DL767953672
NO TEST · 1995-09-10 Matched by certificate designator
ATA 3350

Part: EEL BULB — FAILED (CABIN)

EMERGENCY EXIT LIGHT FWD OF C2 DOOR INOP. RELAMPED AND OPS NORMAL.

Source: SDR DL767953660
NO TEST · 1995-09-10 Matched by certificate designator
ATA 3350

Part: EEL BULB — FAILED (CABIN)

F/C FWD CROSS AISLE AREA PATH LIGHT AND MID GALLEY RT AISLE AREA LIGHT OUT. RELAMPED AND OPS NORMAL.

Source: SDR DL767953661
OTHER · 1995-03-20 Matched by certificate designator
ATA 5753

Part: FLAP — HOLE IN SKIN (LT WING AFT)

FOUND DURING LETTER CHECK, HOLE IN BOTTOM OF NR 2 AFT FLAP I/B. REPAIRED PER SRM 51-70-10 AND 57-53-01.

Source: SDR DL767951203