N112BZ

EMBRAER EMPRESA BRASILEIRA DE ERJ 190-100 IGW · 2007 · Fixed-wing multi-engine · 2 engines · 112 seats · Valid Registration

Registered owner: BANK OF UTAH TRUSTEE, UT (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

5 reports on file, 2021-09-20 – 2024-11-13.

NO TEST · 2024-11-13 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — FAILED (ZONE 200) · airframe 38,486 hrs · 19,117 cycles

AFT INTERIOR EMERGENCY LIGHT STAYS ON AFTER POWER DOWN. EMERGENCY LIGHT POWER UNIT FAILED. REPLACED #5 EMERGENCY LIGHT POWER UNIT.

Source: SDR BAGA202411130282
OTHER · 2023-11-17 Matched by certificate designator
ATA 5300

Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 37,741 hrs · 18,631 cycles

DENT AND CRACK IN LH FUSELAGE AFT OF MAIN CABIN DOOR CAUSED BY AIRSTAIR CONTACT. ACCOMPLISHED A PERMANENT DOUBLER REPAIR OF DENT AND CRACK LOCATED ON FWD LH FUSELAGE BETWEEN FR20 AND FR23 AND BETWEEN STGR 10 AND STGR 12 AS PROVIDED IN ETD2023-190-028742 REV A

Source: SDR BAGA2023112080003
OTHER · 2023-11-11 Matched by certificate designator
ATA 5330

Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 37,741 hrs · 18,631 cycles

DENT AND CRACK IN LH FUSELAGE AFT OF MAIN CABIN DOOR CAUSED BY AIRSTAIR CONTACT DURING GROUND HANDLING. BREEZE ENGINEERING RELEASED THE REPAIR INSTRUCTIONS ON 11/15/23. ACCOMPLISHED A PERMANENT DOUBLER REPAIR OF DENT AND CRACK LOCATED ON FWD LH FUSELAGE BETWEEN FR20 AND FR23 AND BETWEEN STGR 10 AND STGR 12 AS PROVIDED IN ETD 2023 - 190-028742 REV A ON 11/16/2023. DUE TO THE WEEKEND THIS SDR IS BEING REPORTED ON 11/20/23. THE DIFFICULTY DATE IS THE DATE OF THE DAMAGE OCCURRED. THE REPAIR WAS NOT RECORDED IN A BREEZE EC UNTIL 11/16/23. THIS SUBMISSION ALSO CORRECTS THE CONTROL# OF THE ORIGINAL SUBMISSION OF THIS SDR.

Source: SDR BAGA2023112000003
OTHER · 2022-12-23 Matched by certificate designator
ATA 5310

Part: BEAM — CORRODED (L1 DOOR FRAME) · airframe 37,038 hrs · 18,122 cycles

L1 DOOR CUTOUT STRUCTURE LOWER BEAM CORRODED UNDER AFT SLIDE FITTING. - REMOVED AND REPLACED LOWER BEAM AT L1 DOOR FLOOR LEVEL IAW BREEZE TC CATA-53EA-00576.

Source: SDR BAGA202212270003
WARNING INDICATION · 2021-09-20 Matched by certificate designator
ATA 5270

Part: NONE — NONE · airframe 35,969 hrs · 17,312 cycles

DOOR PAX AFT OPEN" EICAS WARNING IN FLIGHT ( DOOR POSITION INDICATION ON MFD AND ASSOCIATED EICAS MESSAGES PASSENGER (L1, L2) AND SERVICE (R1, R2) DOORS ) REMOVED AND REPLACED AFT PAX DOOR CLOSED SENSOR AND OPS CHECKED GOOD PER AMM 52-12-00

Source: SDR BAGA005