FOUND CRACK ON UPPER FUSELAGE CROWN SKIN AT STA. 654+22, SR-1 SR-2
VERTICAL ANGLE CRACKED AT STA. 1085 LBL 26. CLIP MONOCOQUE
LEFT SIDE OF CHORD AT STA. 1809 TENSION FITTING FORWARD BOLT HOLE HAS CRACK
LEFT HORIZONTAL INBD UPPER FIXED L/E IS DELAMINATED.
ON APPROACH, SELECTED FLAPS TO 20. RECEIVED TE FLAP DISAGREE EICAS MESSAGE. DID GO AROUND, DECLARED EMERGENCY, AND LANDED WITHOUT INCIDENT. MAINTENANCE PERFORMED FIM PROCEDURE. NO DEFECTS NOTED.
1 EA ESCAPE INERTIAL REEL DEVICE FULL OUT(<P>TRANSFER TO DMI 213408 PER MEL 25-61-01-01 CAT C DUE DATE 4AUG2024. PN 379103D-29</P> / <P>LP 1239968 ITEM 5 / ONT / 27JUL24: INSTALLED 1 EA INERTIA REEL IAW B767 AMM 25-61-01. NO FUTHER DEFECTS NOTED. THIS CLEARS MDDR 213408, PLACARD REMOVED.</P>)
INERTIAL ESCAPE REEL DROPPED DURING DESCENT(<P>REVOVED AND REPLACED EMERGENCY DESCENT DEVICE IAW AMM 25-51-05. THIS CLEARS MDDR 205698. PLACARD REMOVED.</P>)
INERTIAL REEL DEPLOYED ON TAKE-OFF ROLL(<P>R/R DEPLOYER DESCENT DEVICE IAW AMM 25-61-05. NO FURTHER DEFECTS NOTED</P>)
NOSE AIR/GRND STATUS MESSAGE(<P>INSTALLED TARGET AND ADJUSTMENT BRACKET INSTALLED IAW BOEING AMM 32-61-03 AND OPS CHECK CARRIED OUT IAW AMM 32-61-03, OPS CHECK GOOD.</P>)
ONE ESCAPE REEL REMOVED FROM AIRPLANE ( FLIGHT CREW/SUPERNUMERARY ESCAPE DEVICES {ALL CARGO CONFIGURATION} INERTIAL ESCAPE REELS )(<P>REMOVED AND REPLACED ESCAPE REEL IAW AMM 25-61-04. NO FURTHER DEFECTS NOTED. THIS CLEARS MDDR 203776. PLACARDS REMOVED. MCC NOTIFIED.</P>)
ONE INERTIA DESCENT REEL FELL OUT OF HOLDER AND UNWOUND ON CLIMBOUT(<P>REPLACED THE SECOND AFT INERTIA DESCENT REEL DEVICE IAW AMM 25-61-05. THIS CLEARS MDDR 200637. MCC NOTIFIED.</P>)
ESCAPE REELS REQUIRE INSPECT/STOWING MULTIPLE UNLOCKED DURING TAKEOFF(<P>R/R INERTIAL ESCAPE REEL IAW AMM 25-61-05. OPS CHECK GOOD. DMI 199173 CLOSED.</P>)
LIGHTNING STRIKE DAMAGE ON EXTERNAL FUSELAGE SKIN BETWEEN STA 654+22 / STA 654+44 AND STRINGER S-25LH.(<P>AFFECTED AREA WAS OVERSIZED AND REPAIRED PER SRM 53-00-01-2R-8. NO FURTHER DEFECTS NOTED</P>)
CORROSION ON BUSHINGS FROM LH MAIN LANDING GEAR SUPPORT BEAM(<P>BUSHINGS WERE REPLACED PER SOPM 20-50-03 AND MXA EO TRE6757193 (CMM 57-54-13 REPAIR 2-1) MAJOR REPAIR. PN: 113T1108-17 AND 113T1108-23</P>)
CORROSION ON BUSHINGS FROM RH MAIN LANDING GEAR SUPPORT BEAM(<P>BUSHINGS WERE REPLACED PER SOPM 20-50-03 AND MXA EO TRE6757194 (CMM 57-54-13 REPAIR 2-1)</P> / <P>MAJOR REPAIR PN: 113T1108-17 AND 113T1108-23</P>)
STABILIZERS - HORIZONTAL STABILIZER - RH HINGE FITTING BUSHING AND PIVOT BEARING CORROSION / SCRATCH DAMAGES(<P>THE HINGE FITTINGS WERE REPLACED / REPAIRED AND THE PIVOT FITTING WAS REWORKED WITH A SPECIAL TOOL PER MXA EO TRE6755055 REV 1. NO FURTHER DEFECTS NOTED. NOTE: AS ADDITIONAL INFORMATION THE BUSHINGS WERE REPLACED.</P>)
LIGHTNING STRIKE DAMAGE ON EXTERNAL FUSELAGE SKIN BETWEEN STA 196.5 AND 8.5 INCH LOWER OF STRINGER S-21LH(<P>AFFECTED AREA WAS OVERSIZED AND REPAIRED PER SRM 53-00-01-2R-8. NO FURTHER DEFECTS NOTED</P>)
LIGHTNING STRIKE DAMAGE ON EXTERNAL FUSELAGE SKIN BETWEEN STA 390 AND STRINGERS S-27LH / S-28LH(<P>AFFECTED AREA WAS OVERSIZED AND REPAIRED PER SRM 53-00-01-2R-8. NO FURTHER DEFECTS NOTED</P>)
HORIZONTAL STABILIZER CENTER SECTION UPPER SKIN SURFACE WITH CORROSION DAMAGE BETWEEN RBL13.833 / RBL 32.67 AND STGR 3.(<P>DOUBLER REPAIR WAS INSTALLED PER MXA EO TRE6755054 (BOEING SR 3-5632149492). NO FURTHER DEFECTS NOTED.</P>)
VERTICAL STABILIZER, RH SURFACE, COMPOSITE PANEL DESBONDED BETWEEN AUXILIARY SPAR TO FRONT SPAR BETWEEN FSS 220.521 / FSS 321.046(<P>REPAIRED PER SRM 51-70-10-2R-4. NO FURTHER DEFECTS NOTED</P>)
LIGHTNING STRIKE DAMAGE ON EXTERNAL FUSELAGE SKIN BETWEEN STA 174.5 AND 5 INCH ABOVE OF STRINGER S-27LH(<P>AFFECTED AREA WAS OVERSIZED AND REPAIRED PER SRM 53-00-01-2R-8. NO FURTHER DEFECTS NOTED.</P>)
LIGHTNING STRIKE DAMAGE ON EXTERNAL FUSELAGE SKIN BETWEEN STA 654+44 / STA 654+66 AND STRINGER S-25LH.(<P>AFFECTED AREA WAS OVERSIZED AND REPAIRED PER SRM 53-00-01-2R-8. NO FURTHER DEFECTS NOTED</P>)
LIGHTNING STRIKE DAMAGE ON EXTERNAL FUSELAGE SKIN BETWEEN STA 654 AND STRINGER S-25LH.(<P>AFFECTED AREA WAS OVERSIZED AND REPAIRED PER SRM 53-00-01-2R-8. NO FURTHER DEFECTS NOTED</P>)
LIGHTNING STRIKE DAMAGE ON EXTERNAL FUSELAGE SKIN BETWEEN STA 412 AND STRINGERS S-27LH / S-28LH(<P>AFFECTED AREA WAS OVERSIZED AND REPAIRED PER SRM 53-00-01-2R-8. NO FURTHER DEFECTS NOTED</P>)
LIGHTNING STRIKE DAMAGE ON EXTERNAL FUSELAGE SKIN BETWEEN STA 325 AND STRINGERS S-28LH / S-29LH(<P>AFFECTED AREA WAS OVERSIZED AND REPAIRED PER SRM 53-00-01-2R-8. NO FURTHER DEFECTS NOTED</P>)
FWD CARGO COMPARTMENT, FLOOR LEVEL, CORROSION ON FRAME WEB UPPER CHORD AT STA 654+44 LBL20(<P>AFFECTED ITEM WAS REPAIRED IAW B767 SRM 53-00-07-2R-4. NO FURTHER DEFECTS NOTED</P>)
LH INBD FLAP, SUPPORT RIB AT IFS 129 APPROX INNER SKIN WITH DENT(<P>AFFECTED AREA WAS REPAIRED PER SRM 51-70-10-2R-4. NO FURTHER DEFECTS NOTED</P>)
LIGHTNING STRIKE DAMAGE ON EXTERNAL FUSELAGE SKIN BETWEEN STA 632 AND STRINGER S-25LH(<P>AFFECTED AREA WAS REPAIRED PER TRE6753601 (IAI CUSTOMER SERVICE #CS-26206-003). NO FURTHER DEFECTS NOTED.</P>)
LIGHTNING STRIKE DAMAGE ON EXTERNAL FUSELAGE SKIN BETWEEN STA 500 AND STRINGERS S-27LH / S-28LH(<P>AFFECTED AREA WAS OVERSIZED AND REPAIRED PER SRM 53-00-01-2R-8. NO FURTHER DEFECTS NOTED.</P>)
LIGHTNING STRIKE DAMAGE ON EXTERNAL FUSELAGE SKIN BETWEEN STA 368 AND STRINGERS S-28LH / S-29LH(<P>AFFECTED AREA WAS OVERSIZED AND REPAIRED PER SRM 53-00-01-2R-8. NO FURTHER DEFECTS NOTED.</P>)
VERTICAL STABILIZER REAR SPAR, UPPER PCA LINKAGE, RH HINGE WITH FREE PLAY(<P>UPPER PCA LINKAGE WAS REPLACED PER AMM 27-21-02-022-035 / -038. OPS CHECK GOOD</P>)
FUEL LEAK AT BODY SPLICE OF STGR L-6 AND RBL 97.42, WING CENTER SECTION(<P>&NBSP;</P> / <P><SPAN>FUEL LEAK AT BODY SPLICE OF STRINGER&NBSP;</SPAN><SPAN>L-6 AND RBL 97.42 WING CENTER SECTION&NBSP;</SPAN><SPAN>WAS REPAIRED AND TEST WAS SATISFACTORY</SPAN></P>)
FUEL LEAK AT BODY SPLICE OF STGR L-10 AND LBL 97.42, WING CENTER SECTION(<P><SPAN>FUEL LEAK AT BODY SPLICE OF STRINGER&NBSP;</SPAN><SPAN>L-10 AND LBL 97.42, WING CENTER SECTION&NBSP;</SPAN><SPAN>WAS REPAIRED AND TEST WAS SATISFACTORY</SPAN></P> / <P>&NBSP;</P>)
FUEL LEAK AT BODY SPLICE OF STGR L-6 AND LBL 97.42, WING CENTER SECTION(<P>FUEL LEAK AT BODY SPLICE OF STGR L-6 AND LBL 97.42, WING CENTER SECTION WAS REPAIRED AND TEST WAS SATISFACTORY.</P>)
RUDDER UPPER PCA WITH FREE PLAY OUT OF LIMITS(<P>RUDDER UPPER PCA WAS REPLACED PER AMM 27-21-02-422-038. OPS CHECK GOOD</P>)
STABILIZERS - HORIZONTAL STABILIZER - LH HINGE FITTING BUSHING AND PIVOT BEARING CORROSION / SCRATCH DAMAGES(<P>THE HINGE FITTINGS WERE REPLACED / REPAIRED AND THE PIVOT FITTING WAS REWORKED WITH A SPECIAL TOOL PER MXA EO TRE6755056. NO FURTHER DEFECTS NOTED. NOTE: AS ADDITIONAL INFORMATION THE BUSHINGS WERE REPLACED.</P>)
CORROSION ON INTERNAL FUSELAGE SKIN BETWEEN STA 1562 AND STRINGER S-9RH / S-10RH(<P>DOUBLER REPAIR WAS INSTALLED PER MXA EO TRE6753595 REV 1 ISSUED ON MAY 15, 2023 (FVCI PROJECT NO. 23088-6). NO FURTHER DEFECTS NOTED</P>)
CORROSION ON INTERNAL FUSELAGE BEARSTRAP BETWEEN STA 1540 AND STRINGER S-10RH / S-11RH(<P>DOUBLER REPAIR WAS INSTALLED PER MXA EO TRE6753594 ISSUED ON MAY 09, 2023 (FVCI PROJECT NO. 23088-5). NO FURTHER DEFECTS NOTED</P>)
CORROSION ON INTERNAL FUSELAGE SKIN BETWEEN STA 654+110 AND STRINGER S-9RH / S-10RH(<P>THE SURFACE PROTECTION WAS RESTORED ON THE REWORKED AREA PER MXA EO TRE6753589 (FVCI PROJECT NO. 23088-7). NO FURTHER DEFECTS NOTED</P>)
CORROSION ON INTERNAL FUSELAGE SKIN BETWEEN STA 1461 AND STRINGER S-14RH / S-15RH(<P>DOUBLER REPAIR WAS INSTALLED PER MXA EO TRE6753590 ISSUED ON MAY 04, 2023 (FVCI PROJECT NO. 23088-1). NO FURTHER DEFECTS NOTED</P>)
CORROSION ON INTERNAL FUSELAGE SKIN BETWEEN STA 1461 AND STRINGER S-12RH(<P>THE SURFACE PROTECTION WAS RESTORED ON THE REWORKED AREA PER MXA EO TRE6753591 (FVCI PROJECT NO. 23088-2). NO FURTHER DEFECTS NOTED</P>)
CORROSION ON INTERNAL FUSELAGE SKIN BETWEEN STA 1461 AND STRINGER S-8RH / S-10RH(<P>DOUBLER REPAIR WAS INSTALLED PER MXA EO TRE6753592 ISSUED ON MAY 05, 2023 (FVCI PROJECT NO. 23088-3). NO FURTHER DEFECTS NOTED</P>)
CORROSION ON INTERNAL FUSELAGE SKIN BETWEEN STA 1480 / DSTA 876.3 AND STRINGER S-9RH / S-10RH(<P>DOUBLER REPAIR WAS INSTALLED PER MXA EO TRE6753593 ISSUED ON MAY 05, 2023 (FVCI PROJECT NO. 23088-4). NO FURTHER DEFECTS NOTED</P>)
CORROSION ON PANEL UNDER ROLLER TRAYS BETWEENÃÂ STA 564+66 AND STA 564+88 FROMÃÂ FWD CARGO COMPARTMENT, FLOOR LEVEL.(<P>PANEL WAS REPLACED PER SRM 51-10-02-0G PAR.9. NO FURTHER DEFECTS NOTED</P>)
LIGHTNING STRIKE DAMAGE ON FASTENER OF FUSELAGE EXTERNAL SKIN BETWEEN STA 566 AND STRINGERS S-27LH AND S-28LH.(<P>AFFECTED AREA WAS OVERSIZED AND REPAIRED PER SRM 53-00-01-2R-8. NO FURTHER DEFECTS NOTED</P>)
ON TAXI OUT R ENG BLEED LIGHT AND EICAS MESSAGE ON FOLLOWED STEP 3 OF APPLICABLE DDG 36-11-02 LIGHT AND DID NOT CLEAR PER MCC GUIDANCE RH ENGINE TO 70 PERCENT AND MESSAGE DID NOT CLEAR(<P>REMOVED AND REPLACED THE RH ENGINE HIGH PRESSURE CONTROLLER IAW B767 AMM 36-11-08/401. PERFORMED ENGINE RUN. NO ENG BLEED LIGHT OR EICAS MESSAGE. LEAK CHECK GOOD</P>)
ESCAPE REEL HANDLE FELL OUT AFTER LANDING(<P>R/R DESCENT DEVICE "B" IAW AMM 25-61-05. NO FURTHER DEFECTS NOTED</P>)
DURING DEPARTURE IN CLIMB OUT, ACFT ENTERED AREA OF SEVERE TURBULENCE & W/S, ACFT INDICATED O/S OF 285, SPEED TAPE WITH NO ASSOCIATED OVERSPEED WARNINGS IAW 05-51-04, DATA FROM OUR ENGINEERING TEAM SHOWS AIRCRAFT DID NOT SHOW "G" LOADS OF SEVERE TURBULENCE. NO FURTHER INSPECTION REQUIRED. OPEN AND CLOSED PANELS 335CB, 335DB, 335AFB, 335GB, 335HB, 335JB, 335KB, NO DAMAGE NOTED.
EMERGENCY LIGHT GUARD INOP WITH GUARD CLOSED, EMER LIGHT REMAIN UNARMED. R/R EMERGENCY LIGHT GUARD IAW AMM 33-51-00. OPS CHECKED GOOD.
DESCENT DEVICE INOP(<P><SPAN>PER CREW, UPON OPENING STORAGE DEVICE. DESCENT REEL DROPPED DOWN. RESECURED DESCENT DEVICE IAW AMM 25-61-05. NO FURTHER DEFECTS NOTED.</SPAN></P>)
FWD CARGO CREW OXYGEN NEED SERVICE TO FULL .(<P>REMOVED, SERVICED & REINSTALLED FWD CARGO CREW O2 BOTTLE PER B767-300</P> / <P>AMM 12-15-08, 35-00-00, 35-11-00 & AC 43.13-1B PAR 9-46 THRU 9-51 PGS&NBSP; 9-448&NBSP; THRU 9-455.&NBSP;&NBSP;</P> / <P>NO LEAKS. P/N B42365-1. S/N R12-001419.</P>)
COCKPIT F/O SEAT LIFE VEST POUCH VELCRO LOOSE .(<P>SECURED VELCRO AT COCKPIT F/O SEAT LIFE VEST AS PER 767-300 AMM 20-30-01-992-001</P>)
COCKPIT LH STOWAGE LIFE RAFT P/N RO425A-107 S/N TAL6A072 DUE FOR SERVICE.(<P>REMOVED AND REPLACED COCKPIT LOWER LIFE RAFT AS PER&NBSP; B767-300&NBSP; AMM 25-62-00.</P>)
APU SQUIB P/N 30903856 S/N 01189 DUE FOR TIME CHANGE .(<P>REMOVED & REPLACED APU SQUIB PER B767-300 AMM 26-22-02.</P> / <P>SQUIB TEST PASSED . NEW&NBSP; DUE&NBSP; DATE&NBSP; &NBSP; &NBSP;31 OCT 29</P>)
COCKPIT 1ST OBS SEAT BELTS MISSING COTTER PINS(<P>REMOVED AND REPLACED 1ST OBS COTTER PINS IAW B767-300 AMM 20-10-23</P>)
ENG. #1 O/B CORE COWL HOLD OPEN ROD DAMAGED(<P>REMOVED AND REPLACED #1 O/B CORE COWL HOLD OPEN ROD IAW&NBSP; B767-300 AMM 71-11-11</P> / <P>OPS&NBSP; CHECK&NBSP; GOOD</P>)
ENG #1 I/B T/R WITH SEAL DAMAGED LOCATED AT INTERNAL AREA .(<P>PREPARED, CLEANED, AND REPAIRED FIRE RETARDANT SEAL INNER AREA OF ENG. # 1 I/B T/R PER B767-300 AMM 78-31-00-308-072-H00 .</P>)
LEFT INB AFT FLAP OB SIDE HAS SEAL MISSING .(<P><SPAN>REMOVED&NBSP; AND&NBSP; INSTALLED&NBSP; SEAL&NBSP; AT&NBSP; LEFT&NBSP; INB&NBSP; AFT&NBSP; FLAP&NBSP; O/B&NBSP; &NBSP;SIDE&NBSP; AS&NBSP; PER&NBSP; 767-300&NBSP; &NBSP;</SPAN></P> / <P><SPAN>AMM&NBSP; 20-10-23-964-001</SPAN></P>)
RH INB MID FLAP OB SIDE WITH AERODYNAMIC SEAL DAMAGED .(<P><SPAN>REMOVED&NBSP; AND&NBSP; INSTALLED&NBSP; AERODYNAMIC&NBSP; SEAL&NBSP; AT&NBSP; R/H&NBSP; INB&NBSP; MID&NBSP; FLAP&NBSP; O/B&NBSP; SIDE&NBSP; AS&NBSP; PER&NBSP; 767-300</SPAN></P> / <P><SPAN>AMM&NBSP; &NBSP;20-10-23-964-001</SPAN></P>)
EICAS: R GEN OFF AT ENG START, QRH 6.12 ACOMPLISHED + RESET OPS NORMAL(<P><SPAN>COMPLETED WITH OPS CHECK FOR RH GEN IN REF. AMM 71-00-00. ( ENT RUN ). OPS CHECK GOOD. NO FAULTS NOTED.&NBSP;</SPAN></P>)
LH WING I/B FLAP LOWER SURFACE HAS BULGING AREA AT FASTENER ROW JUST I/B OF O/B TRACK.(<P>REMOVED CORROSION LH WING I/B FLAP LOWER SURFACE. ORIG. MAT. WAS .125" REMAINING MAT. IS .034" IS FOUND TO BE OUT OF LIMITS IAW B767 SRM 57-53-01. REMOVED AND REPLACED LH WING I/B FLAP UPON CUSTOMER REQ. IAW B767 AMM 27-51-06, 27-51-07</P>)
FLIGHT DECK ENTRYWAY L/H SIDE AFT END OF SLIDE CONTAINER BOTTOM SIDE EMERGENCY EXIT LIGHT CRACKED AND DAMAGED. CAUTION: COULD BE HAZMAT HAZARD.(<P>REMOVED AND REPLACED FLIGHT DECK ENTRYWAY L/H SIDE AFT END OF SLIDE CONTAINER BOTTOM SIDE EMERGENCY EXIT LIGHT IAW B767 AMM 33-51-01.</P>)
AREA OF CORROSION ON R/H HORIZ STAB UPPER SURFACE AT FRONT SPAR JUST O/B OF BANANA FAIRING.(<P>BLENDED THE AREA ON THE R/H HORIZONTAL STABILIZER UPPER SURFACE AT FRONT SPAR JUST O/B OF THE BANANA FAIRING IAW B767 SRM 51-10-02. UPON THE EVALUATION THE AREA WAS DEEMED IN LIMITS IAW FAS EA 21078 REV:IR</P>)
F/O ESCAPE ROPE PANEL WILL NOT LATCH CLOSED.(<P>RE-SECURED FO ESCAPE ROPE PANEL IN REF AMM 25-61-05.</P>)
STATUS MESSAGES AFT EQ FAN 1 & AFT EQ FAN 2(<P>FLIGHT CREW FOUND FWD & AFT CARGO FIRE ARM SWITCHES DEPRESSED. CYCLED SWITCHES. NO MESSAGES PRESENT AT THIS TIME, DONE IAW B767 AMM 26-19-00.</P>)
UPON SHUTTING DOWN LEFT ENGINE L AC BUS MESSAGE DISPLAYED REMAINED ILLUMINATED UNTIL EXT POWER SELECTED.(<P>PERFORMED FIM TASK 24-32 FT803 BLOCKS 1 AND 2 FOLLOWED BY ENGINE RUN IAW AMM 71-00-00. OPS NORMAL AT THIS TIME. NO FURTHER DEFECTS NOTED. NUSSIANCE FAULT DUE TO IMPROPER ENGINE SHUTDOWN WITHOUT EXT POWER ON OR APU POWER ON.</P>)
SMALL CHIP ON OUTER FAN BLADE # 18 OF RIGHT ENGINE(<P>NICK FOUND TO BE WITHIN REPAIRABLE LIMITS, BLENDED PER AMM 72-31-02. NO FURTHER DEFECTS NOTED. OK FOR SVC. TRANSFERRED TO NON MEL 152213 FOR DYE PENETRANT WITHIN 50FH 0R 10 FC,</P> / <P><SPAN>LP 1368567: PERFORMED FPI I/A/W 72-31-02; NO DEFECTS NOTED AT THE TIME OF INSPECTION. THIS CLOSES NON-MEL# 152213.</SPAN></P>)
R STARTER CUTOUT EICAS MESSAGE ILLUMINATED MOMENTARILLY. WHILE AT CRUISE. REPEATED SEVERAL TIMES BUT ONLY FOR A SECOND AT A TIME.(<P>R/R RIGHT ENG STARTER VALVE PER AMM 80-11-02. PERF ENG RUN IAW AMM 71-00-00. OPS TEST NORMAL, NO DEFECTS NOTED, ITEM 2 IS RELATED TO STARTER VALVE MALFUNCTION AND ITEM IS CLEARED ON ITEM 1.</P>)
APU FAULT EICAS DURING TAXI IN.(<P>PERFORMED APU BITE TEST PER FIM 45-11 FT 958. NO FAULTS FOUND. NO MINI FLAGS APU OIL LEVEL GOOD. OPS TESTED APU NORMAL PER AMM 49-11-00&NBSP;</P>)
EQUIPMENT COOLING "VALVE "LIGHT ILLUMINATED.(<P>CYCLED EQUIPMENT COOLING SELECTOR SWITCH FROM "AUTO" TO "STBY" REF B767 AMM 21-58-00 VALVE CLEARD ONCE SWITCH WAS TAKEN BACK TO AUTO. NO FURTHER EFFECTS NOTED.</P>)
APU PNEUMATICS INOP. T/S IAW FIM 49-11 FAULT TREE. NO FAULTS FOUND. PERFORMED VISUAL INSPECTION ON APU BLEED AIR DUCT IAW AMM 36-11-02. NO DEFECTS FOUND. PERFORMED ENGINE RUN IAW AMM 72-00-00.
STATUS 'AFT EQ EXH FAN 2'(<P>PERFORMED FIM TASK 21-26 FAULT TREE 808. NO FAULTS FOUND. COULD NOT DUPLICATE. OPS CHECKS GOOD.</P>)
R ENG STARTER EICAS MSG DURING ENG START. 2ND. ATTEMPT OK.(<P>PERFORMED R/H ENG STARTER VALVE OPS CHECK IAW B767 AMM 71-00-00. NO DEFECTS NOTED AT THIS TIME. A/C OK FOR SERVICE.</P>)
AFTER SHUTDOWN TR UNIT STATUS MESSAGE DISPLAYED(<P><SPAN>PERFORMED T/S PER FIM 24-32 F/T 803, NO DEFECTS NOTED, SYSTEM OPS CHECK NORMAL.</SPAN></P>)
APU DEFERRED PER MCC (INOP)(<P>TRANSFER TO MDDR DMI #150314 IAW B767 DDG MEL 49-11-01A, CAT C, DUE 27JUL21 "M" PROC C/W.&NBSP;</P> / <P>C/W WITH ECM #2021P-233 REF. LOGPAGE 1369494 ITEM 8...REPLACED DE-OIL SOLENOID VALVE.. P/N 3876166-1..S/N 1102&NBSP; ON APU IAW AMM49-27-08 OPS CKS GOOD...</P> / <P>REFERENCE ITEM 9 THIS LOG PAGE..REPLACED APU OIL TEMP SWITCH IAW AMM 49-27-14 LEAK CKS GOOD. THIS CLEARS MDDR 150314.</P>)
EXCESSIVE OIL FOUND ON INBOARD SURFACE OF LEFT ENGINE EXHAUST COWL (6 O'CLOCK POSITION).(<P>OPENED AND INSPECTED LEFT ENGINE EXHAUST COWL FOR OIL LEAKS, NO LEAKS NOTED.</P>)
EICAS MSG "R STARTER CUTOUT" INTERMITTENTLY DISPLAYED IN CRUISE FOR ABOUT 3-5 SECONDS.(<P>RIGHT STARTER VALVE PREV REPLACED ON 03APR21. PERFORMED OPS CHECK IAW AMM 71-00-00. OPS CHECK OK. DUE TO HISTORY REPLACED N2 SPEED CARD (M1092) IAW AMM 73-21-54. REMOVED AND REPLACED START 1 RELAY K666 ON P6 PER SWPM 20-81-20 & WDM 80-11-21. RAN ENGINE # 2. OPS CHECK GOOD. RELAY PN: BACR13CG2A</P>)
DURING CLIMB WHEN SELECTING L ENG ANTI-ICE FROM ON TO OFF THE L ENG ANTI ICE EICAS MESSAGE DISPLAYED FOR APPROX 3-5 SECONDS, WENT AWAY(<P>PER AMM 30-21-00 SYSTEM OPERATES NORMAL. NO FURTHER DEFECTS NOTED AT THIS TIME.</P>)
WHEN SHUTTING DOWN LEFT ENGINE IN THE BLOCKS, THE L AC BUS FAILED.(<P>T/S PER FIM 24-32 FT 803, SYSTEM TEST OK, T/S PER FIM 24-20 FT 801. NO FURTHER DEFECTS NOTED AT THIS TIME, A/C IS OKAY FOR FURTHER SERVICE.</P>)
BAD POWER TRANSFER STARTING RT ENGINE. RETURN TO BLOCK TO POWER RESTART.(<P>PERFORMED RESET IAW AMM 24-22-00 RT GEN PER RH ENG RUN IAW 71-00-00 POWER TRANSFER SUCCESSFUL. NO FUTHER DEFECTS NOTED.</P>)
L WX RADAR FAILED TWICE IN FLIGHT, SWITCHED TO R WX RADAR AND THE SYSTEM WORKED NORMALLY.(<P>TRANSFERRED TO DMI # 148947, CAT D, DUE DATE 18OCT21 IAW DDG 34-43-01 T.I. LUC 2223Z.</P> / <P>CVG MX, 21JUN21, LP 1444308, ITEM M7: REMOVED AND REPLACED WX RADAR TRANSCEIVER IAW AMM 34-43-01. OPS CHECK GOOD AT THIS TIME. MEL 148947 CLOSED, MCC NOTIFIED. PLACARD REMOVED. DISP: DSP: JL TIME : 17:30Z.</P> / <P>&NBSP;</P>)
FWD CABIN INOP(<P>PERFORMED FIM 21-60 FT 804 ZONE TEMPERATURE BITE PROCEDURE FAULT LIGHT FOR FWD ZONE TRIM VALVE: ILLUMINATED & PERFORMED FIM 21-60 FT 811 HAD FWD TEMP MSG & FWD CAB INOP LIGHT. REMOVED AND REPLACED FWD TRIM AIR MODULATING VALVE IAW AMM 21-61-07, OPS CHK GOOD & LEAK CHK GOOD. BITE CHK PASSED, NO ACTIVE FAULTS, NO EICAS MSG & NO FWD CAB INOP LIGHT.</P>)
LEFT ENG ANTI ICE VALVE DID NOT CLOSE WHEN SWITCH OFF(<P>PERF OPS CHECK OF L ENG TAI VALVE, OPS CHECK GOOD. NO DEFECTS NOTED AT THIS TIME. REF: 30-21-03-404-022</P>)
L RADAR "WXR FAIL" DURING CLIMB. WHEN IT WAS OPERATIONAL, IT APPEARED TO BE TILTED LOWER THAN SELECTED TILT.(<P>REMOVED AND REPLACED L/H R/T TRANCEIVER IAW B767 AMM 34-43-01. OPS CHECK GOOD AT THIS TIME.</P>)
RT FIRE LOOP1, RT FIRE LOOP 2(<P>REMOVED AND REPLACED RT ENG FIRE LOOP 1 AMM 26-11-02. REMOVED AND REPLACED RT ENG FIRE LOOP 2 DET ELEMENT. OPS NORMAL IAW AMM 26-11-02.</P>)
FWD CABIN TEMP EICAS MESSAGE.(<P>PERFORMED BITE ON ZONE TEMP CONTROLLER. PER 21-60-99 MSG CLEARED, OPS CK NORMAL, NO FAULTS NOTED.</P>)
FWD CABIN TEMP EICAS MSG PRIOR TO BLOCK OUT(<P>DEFER PER MEL 21-61-01-02 CAT C DUE 13JUN21 REF MDDR 147976 CW AT 22:41Z.</P><P>LOG 1343041 ITEM #4&NBSP;TROUBLE SHOOT PER FIM 21-60 FAULT TREE 806. MESSAGE NOT DISPLAYED. OPS NORMAL. THIS CLEARS MDDR #147976. ID@0118Z</P>)
APU FAULT ON FIRST ATTEMPT START OK(<P>TRANSFERRED TO DMI # 147866 CAT C DUE DATE 11 JUN 21 IAW DDG 49-11-01A&NBSP;</P><P>CVG MX, 01JUN21 LP 1306574, ITEM M8: PERFORMED FIM 49-11 TREE 959 & FIM 49-11 963, FIM LEAD TO APU TRU. REMOVED & REPLACED APU TRU IAW 767 AMM 24-32-01, APU OPS CHECK GOOD(3X). MCC NOTIFIED, PLACARDS REMOVED. DMI 147866 CLEARED. TIME/INITIALS: GTC 0317Z.</P>)
R ENG STR CUTOUT EICAS ON SHORT FINAL WENT AWAY TWICE. AFTER LOADING EICAS CAME BACK AND STAYED. RAN QRH CHECK LIST ITEMS.(<P>REMOVED AND REPLACED START VALVE IAW AMM 80-11-02. OPS CHECKS NORM AT THIS TIME. LEAK CHECK GOOD AT THIS TIME.<BR /></P>)
STATUS MSG R ENG IGNITOR 2(<P>REMOVED AND REPLACED RT ENG IGNITOR 2 IAW AMM 74-21-02. OPS CHECK GOOD NO FURTHER DEFECTS NOTED. STATUS MSG CLEARED.<BR /></P>)
RT E/I VALVE DISAGREE LIGHT ILLUMINATED PRIOR TO ENG START. VALVE OPERATED NORMALLY(BUT SLOW) POST START. START CONDUCTED W/ MX & DISP. CONCURRENCE.(<P>C/W ENGINE INLET TAI VALVE OPS CHECK, CHECKS GOOD, PER AMM 30-21-03-404-022 SUBTASK 30-21-03-714-062</P>)
RT E/I VALVE DISAGREE LIGHT ILLUMINATED PRIOR TO ENG START. VALVE OPERATED NORMALLY BUT SLOW POST START. START CONDUCTED W/ MX AND DISPATCH CONCURRENCE.(<P>C/W ENGINE INLET TAI VALVE OPS CHECK, CHECKS GOOD PER AMM 30-21-03-404-022 SUBTASK 30-21-03-714-062.</P>)
ONE ESCAPE INERTIAL REEL FELL OUT OF HOLDER ON TAKE OFF. 6 EACH SERVICEABLE. COMPLIED WITH REEL REMOVAL FROM PLANE SPACER REINSTALLED BACK IN POSITION.</P><P>INSTALLED ESCAPE REEL IAW AMM 25-61-02. THIS CLEARS MDDR 146036. PLACARD REMOVED, MCC NOTIFIED</P>)
FWD CABIN TEMP EICAS MSG.(<P>TRANSFERRED TO MDDR # 145639 OAW MEL 21-61-01-02 DUE DATE: 30APR21 CAT "C". C/W MX PROCEDURE. SP 2315Z</P><P>21APR, ONT MX LP 695222, ITEM M3: PERF OPS CHECK OF ZONE TEMP CONTROL SYSTEM IAW AMM 21-61-00. OPS CHECK GOOD, NO PREVIOUS OR CURRENT FAULTS. THIS CLEARS DMI #145639. MCC NOTIFIED, PLACARD REMOVED. RS @ 1316Z</P>)
DURING TRANSIT CHECK FOUND DESCENT DEVICE DEPLOYED. P/N 379103D-29, SERIAL NO. 20985(<P>TRANSFER TO MDDR 145610 PER MEL 25-61-01-01, CAT C. DUE 30APT21. PLACARDS INSTALLED. DEVICE REMOVED PER MEL. DF 09:58Z</P><P>ONT MX, 21APR21, LP 695223, ITEM M6: INSTALLED NEW EMERGENCY DESCENT DEVICE #2 IAW AMM 25-61-02. NO DEFECTS NOTED. THIS CLEARS MDDR # 145610. PLACARD REMOVED. RS @ 1411Z</P>)
AFTER R ENG START, R GEN WAS INOP(<P>REMOVED AND REPLACED&NBSP;RIGHT ENG GCU PER AMM 24-22-01. OPS TEST GOOD, NO DEFECTS NOTED. ENG RUN PER AMM 71-00-00, OPS GOOD. PLACED .62 ELEC LOAD TO ISOLATE RT GEN APPROX. 5 MINS, NO FAULTS NOTED.</P>)
"OVERSPEED" MSTR WARNING EICAS FLASHED BRIEFLY DURING #2 ENG. START.(<P>A/C ON GROUND DURING "OVERSPEED" INDICATION. C/W FIM FT 34-90-49-00. ADC OPS TEST GOOD PER AMM 34-12-00-715-001. ACCOMPLISHED #2 ENG RUN PER 71-00-00-862-053-H03, FAULT NOT REPRODUCED. NO FAULTS NOTED.</P>)
R STARTER CUTOUT EICAS MESSAGE IN FLIGHT(<P>TRANSFERRED TO&NBSP;MDDR 144761 MEL&NBSP;80-00-02-01 CAT C. 4 APR 2021</P><P>3 APR 2021-LOG PAGE 1465749 M7: REMOVED AND REPLACED #2 ENG START VALVE, IAW AMM 80-11-02, OPS CHECK GOOD. THIS CLEARS DMI 144761, PLACARDS REMOVED.</P>)
MAIN CARGO DOOR FWD SEAL&NBSP; DEPRESSOR DAMAGED(<P>REMOVED & REPLACED DAMAGED SEAL DEPRESSOR BY MAIN CARGO FWD SIDE OF CUT OUT PER&NBSP; B767-300 SRM 51-40-02-0G-0.</P>)
COCKPIT CAPT SEAT LIFE VEST POUCH LOOSE VELCRO(<P>SECURED LIFE VEST POUCH AT COCKPIT CAPT SEAT IAW&NBSP; B767 AMM 20-30-01</P>)
COCKPIT F/O SEAT LAP BELT BUCKLE STORAGE POUCH ON WRONG SIDE OF SEAT COVER(<P>REMOVED & REPLACED SEAT COVER AT F/O SEAT IAW&NBSP; B767-3&NBSP; AMM&NBSP; 20-30-01</P>)
ENGINE #1 HAS PNEUMATIC LEAK @ LOCATION "K"; AS PER EO #1936A088. SEE 8017- TALLY 140 PRV; REPLACEMENT FOR CORRECTION ACTION.
COCKPIT FLASHLIGHT BATTERY DUE FOR SHOP VISIT 2 EACH P/N P4-01-0021. REMOVED AND REPLACED FLASHLIGHT BATTERY AS PER AMM 25-64-00/001. OPS CK OK.
COCKPIT FIRST AID KIT DUE FOR SHOP VISIT. P/N&NBSP; 56-01-0005-306(<P>REMOVED AND REPLACED FIRST AID KIT IN COCKPIT&NBSP; AS PER&NBSP; B767-300&NBSP; AMM 25-60-00</P>)
LAV PORTABLE OXYGEN MASKS DUE FOR SHOP VISIT P/N 289-601-212(<P>REMOVED AND REPLACED LV PORTABLE OXYGEN MASK AS PER&NBSP; B767-300&NBSP; AMM&NBSP; 35-31-00</P>)
#1 ENG T/R LEFT HAND ELECTROMECHANICAL BRAKE DISENGAGE HANDLE WILL NOT LOCK IIN THE UP POSITION(<P>REMOVED & REPLACED #1 L/H T/R ELECTRO-MECHANICAL BRAKE PER 78-34-07-404-005-J00. OPS CHECKED GOOD.
FWD CARGO R/H SIDE COMPARTMENT SERVICE OXYGEN CYLINDER TO FULL(<P>SERVICED FWD CARGO R/H SIDE COMPARTMENT OXYGEN CYLINDER&NBSP; IAW&NBSP; B767-300&NBSP; AMM&NBSP; 12-15-08-603-001&NBSP; AMM&NBSP; 35-00-00-912-005,&NBSP; AMM&NBSP; 35-11-00-206-228,&NBSP; AMM&NBSP; 35-11-00-206-233&NBSP; AC&NBSP; 43.13-1B&NBSP; PAR&NBSP; 9-46 THRU 9-51 PGS&NBSP; 9-448&NBSP; THRU 9-455. NO LEAK NOTED. O2 BOTTLE&NBSP; PN&NBSP; 801307-00&NBSP; SN&NBSP; ST326329</P>)
#1 HPSOV ONLY OPERATES PARTIALLY(<P>REMOVED AND REPLACED #1 ENG HPSOV PER M/M 36-11-05-400-802-001. LEAK & FUNCT CHECK GOOD REQUIRES&NBSP; RUN-UP&NBSP; OPS&NBSP; CHECK.</P><P>PERFORMED POST INSTALLED CHECK IAW AMM 36-11-05 OP CHECK FOUND NORMAL NO LEAKS NOTED.</P>)
#2 ENG FUEL TRANSMIITTER (PRESS) CONNECTOR IS DAMAGED(<P>REPLACED #2 ENG FUEL PRESS TY CONNECTOR&NBSP; D10998 PER SWPM 20-63-00 & W/D 73-33-11</P><P>ENG #2 RUN UP; L&NBSP; PRESS IND.&NBSP; NORMAL PER AMM&NBSP; 73-33-00</P>)
COCKPIT AVSAX CONTAINMENT BAG VACUUM SEAL BROKEN PN&NBSP; AS-002-1(<P>REMOVED AND REPLACED AVSAX CONTAINMENT BAG AS PER&NBSP; B767-300&NBSP; AMM&NBSP; 25-60-00</P>)
NO VIB INDICATION FOR L AND R ENGINE(<P>REPLACED ENG VIB MONITOR UNIT IAW AMM 77-31-03, OPS CHECK GOOD.</P>)
1 INERTIAL ESCAPE REEL CAME UNATTACHED(<P>TRANSFERED TO DMI# 143989 PER MEL 25-61-01-01, MX ACTION C/W. CAT C, DUE DATE 28MAR21.</P><P>LP 1254740: INSTALLED DESCENT DEVICE IAW B767 AMM 25-61-05. THIS CLEARS DMI 143989. PLACARD REMOVED, MCC NOTIFIED.</P>)
LH ENG ANTI ICE LIGHT ON OVERHEAD PANEL STAYS ON WHEN SELECTED.(<P>ITEM TRANSFERRED TO MDDR # 143929 IAW DDG MEL 30-21-02-01A CAT C. DD 26MAR21 MCC NOTIFIED, PLACARD INSTALLED. LH ENG TAI VERIFIED OPERABLE. T&I: SD 1844.</P><P>17MAR21 - LP1254729 - ITEM# 2 - CVG -&NBSP;REMOVED AND REPLACED ANTI ICE PANEL IAW AMM 30-11-01. THIS CLEARS MDDR 143929.</P>)
&NBSP;RIGHT AC BUS OFF AFTER RIGHT ENGINE START FOLLOWED BY NUMEROUS EICAS MSG(<P>PERFORMED BPCU BITE PROCEDURE IAW FIM 24-20-43-801, OPS CHECK GOOD. PERFORMED ENGINE RUN IAW AMM 71-00-00</P>)
LE N2 VIB 3.5 IN DESCEND. EVENT RECORDED(<P>PERFORMED T/S IAW FIM 71-05 FAULT TREE 858, COULD NOT DUPLICATE, FOUND TO BE WITHIN LIMITS. OK FOR SERVICE.</P>)
AFTER LANDING INSPECTION FOUND OUTFLOW VALVE FULLY CLOSED. TRANSFER TO MDDR 143233 IAW DDG 21-31-01A, CAT C, DUE 12MAR21.LP 1145720: REMOVED AND REPLACED;MICRO SW PACK; PER AMM 22-32-04-402-069 DUE TO MICROSWITCH DAMAGE. FOUND PRESS SYS 1 & 2 OPT NORMAL. REF BITE TEST 21-31-00-705-001 NO FAULTS. ACCOMPLISHED MICRO SW ADJUSTMENT PROCEDURE REF AMM 22-32-04-402-065-G AND OPT REF AMM 22-32-04-402-069-H. NO FAULTS DETECTED. OPT NORMAL. OPT NORMAL REF AMM 21-31-00-705-001. NO FAULTS PRESENT. THIS CLEARS DMI # 143233.
RIGHT ENGINE ANTI ICE SWITCH VALVE LIGHT IS ILLUMINATED(<P>PERFORMED OPS TEST OF RT ENG ANTI ICE VALVE AND FOUND VALVE TO OPERATE NORMALLY IAW AMM 30-21-03.</P>)
LEFT ENGINE PEAK FAN VIB 5.0(<P>ITEM TRANSFERRED TO MDDR 142204 PER MEL 22-31-01-01, CAT C, DUE 19FEB21.</P><P>DATE 14 FEB 21 - LP 1253285 - ITEM 7 - RIV -&NBSP;REMOVED AND REPLACE ENGINE VIBE MONITOR IAW AMM 77-31-03-401. THIS CLEARS MDDR 142204.</P>)
L DUCT PRESSURE AFTER ENGINE START @10 PSI AND L END R SLOW TO DEPLOY AND RETRACT(<P>ITEM TRANSFERRED TO MDDR 142202 PER MEL 36-11-02-02, CAT C, DUE 19 FEB21.</P><P>11FEB21 - LG PG 1251312 ITEM 4 TPA - REMOVED AND REPLACED PRESSURE REGULATING VALVE CONTROLLER IAW AMM 36-11-19. OPS AND LEAK CHECK GOOD, THIS CLEARS MEL 142202.</P>)
1 EACH INERTIAL ESCAPE REEL MISSING(<P>TRANSFERRED TO MDDR 142038 PER MEL 25-61-01-01, CAT C, DUE DATE: 16FEB21. DISPATCHER:&NBSP;ZH @ 16:49Z</P><P>LP 1274014: INSTALLED #2 DESCENT DEVICE IAW AMM 25-61-05. NO DEFECTS NOTED. THIS CLEARS DMI 142038.</P>)
CABIN ALT AUTO 1(<P>ITEM PLACED ON MEL 21-31-01A. MDDR 141968. EXP 17FEB21. JJT- 0850Z</P><P>05FEB, RIV, LP 1274000, ITEM M4: PERF FIM 21-31 F/T 803. UP TO BLOCK 6. BIT AUTO 1 CONTROLLER AND FOUND NO FAULTS, SYS OK. THIS CLEARS DMI 141968. ALL PLACARDS REMOVED. TJ 18:35Z.</P>)
WEATHER RADAR TILT NEEDED OVER +2 IN CLIMB AND OVER +1 IN CRUISE TO NOT PICK UP GROUND RETURN. PERFORMED OPERATIONAL TEST OF WX RADAR SYS IAW AMM 34-43-00. OPS NORMAL AT THIS TIME NO DEFECTS NOTED AT THIS TIME.
APU FAULT ON START AFTER LANDING. PERFORMED APU OPERATIONS TEST, TEST NORMAL, IAW AMM 49-11-00.
AFT CABIN TEMP EICAS MESSAGE. TRANSFERRED TO MDDR 141430, IAW MEL 21-61-04-02, CAT C. REMOVED AND REPLACED CABIN TRIM AIR MODULATING VALVE, IAW AMM 21-61-07. OPERATIONS AND LEAK CHECKS NORMAL. THIS CLEARS MDDR 141430.
REV DISPLAYED ABOVE LEFT ENGINE N1 GAUGE NORMAL REVERSE WORKED ON LANDING. TRANSFERED TO MDDR 141401, IAW MEL 78-31-01 CAT C, DUE 04FEB21 PLACARD INSTALLED MX PROCEDURE C/W. REMOVED NR 1 TR OUTBOARD SWITCH, PER B767 AMM 78-36-01 AND REPLACED W/78-36-01. OPERATIONS CHECK GOOD. THIS CLEARS DMI 141481.
AFT ZONE TEMP EICAS MESSAGE. TRANSFERRED TO MDDR 141343, IAW MEL 21-61-01-02, CAT C. PERFORMED BITE TEST, IAW FIM 21-60-60 FAULT TREE 806 FOUND TRIM VALVE TO BE AT FAULT. ALSO OPC AFT TRIM VALVE MODULE, IAW AMM 21-61-07 CONFIRMED VALVE INOPERABLE. WHILE PERFORMING GVI FOUND AFT TRIM VLV, CONNECTOR NOT SECURED. SECURED CONNECTOR, OPERATIONS CHECK GOOD, IAW B767 21-64-01. THIS CLEARS DMI 141343.
EICAS MESSAGE "FWD EQPT OVHT" SHOW AND OVHT LIGHT IS ON, ON THE P5 PANEL. OVERHEAT LIGHT GOES OFF AFTER SELECTING THE EQUIP COOLING SELECTOR TO THE STANDBY POSITION. TRANSFERRED TO MDDR 141061, PER MEL 21-58-01-01 CAT "C" DUE 27 JAN 21. REMOVED AND REPLACED FWD EQP SUPPLY FAN, IAW AMM 21-58-06, OLD UNIT FOUND TO HAVE BROKEN FAN ROTOR BLADES. PERFORMED CLEANING OF SUPPLY FAN SCREEN, IAW AMM 21-58-30. OPERATIONS TEST GOOD. THIS CLEARS DMI 141061.
AFT CABIN TEMP CONTROL EICAS MESSAGE DISPLAYED. TRANSFERRED TO MDDR 141028, PER MEL 21-61-01-02 CAT "C". RAN FIM 21-60 FT 804. CLEANED RHEOSTAT, IAW AMM 12-25-00. OPERATIONS CHECKS, IAW AMM 21-61-00. CLEARED DMI 141028. PLACARD REMOVED.
DURING PERFORMING T/S FOR LT ENGINE BLEED SYSTEM FOUND BLEED AIR CONTROL PC ASSEMBLY CARD BROKEN (M859). ALSO FOUND LT ENGINE BLEED CONT C/B OPEN. REMOVED AND REPLACED L BLEED AIR CONTROL PC ASSEMBLY CARD, IAW B767 AMM 36-11-12. OPERATIONS CHECK GOOD, NO DEFECTS NOTED AT THIS TIME. REMOVED AND REPLACED (2 BLEED AIR ENG N2 RELAY(K00777), IAW WDM 36-11-51. OPERATIONS CHECK GOOD OK FOR SERVICE.
APU FAULT, FAILED TO START ON 2 ATTEMPTS. REMOVED AND REPLACED & APU STARTER, IAW AMM 49-41-01. OPERATIONS CHECK GOOD AT THIS TIME. REMOVED AND REPLACED ECU, IAW AMM 49-61-05. OPERATIONS CHECK GOOD AT THIS TIME. (SN: PN: 2117342-20). TIGHTENED APU VENT LINE AND APU PNEUMATIC SHUTOFF VALVE LINE, IAW AMM 20-11-00.
FWD EQ SUP FAN STATUS MSG(<P>PLACED ON MEL 21-58-04-02-01 CAT "C" DUE DATE 23JAN21. TRANSFERRED TO MDDR# 140831.</P><P>13JAN21 / 1259294 / ITEM 4 / ONT -&NBSP;PERF FIM 21-58 F/T 904 FWD EQP SUP FAN, SWAPPED ECS CONTROL CARD M861 WITH ECS CONTROL CARD M862. STATUS MSG DOES NOT REMAIN. SWAPPED ORG CARDS BACK. PLACED P/N 285T0078-15 ON ORDER.&NBSP; M861 CARD ECS FAN DMI REMAINS OPEN.</P><P>1/17/2021 - LP 1311970 ITEM 5 - BWI:&NBSP;REMOVED AND REPLACED RELAY K343 WDM 21-58-14.OPS TEST GOOD. THIS CLEARS MDDR 140831. PLACARD REMOVED.</P><P><BR /></P>)
APU FAULT WHEN STARTING AFTER LANDING. PERFORMED TEST ON GROUND, IAW AMM 49-41-01. OPERATIONS CHECK TEST OK.
AFT EQ EXHAUST FAN NR 1. REMOVED AND REPLACED NR 1 AFT EQUIPMENT EXHAUST FAN, IAW AMM 21-58-41. OPERATIONS CHECKED GOOD.
L1 DOOR SEAL SHOWING LIGHT. PRESSURIZED IAW AMM 21-31-00. L1 DOOR SEAL OPERATIONS CHECK NORMAL AT THIS TIME.
L RADAR SYSTEM SHOWS INCORRECT/BAD DATA. T/S PER FIM 34-43 FT 812. REMOVED AND REPLACED LT WEATHER TCVR, IAW AMM 34-43-01. OPERATIONS CHECK GOOD. NO DEFECTS NOTED.
LEFT GENERATOR FIELD LIGHT ILLUMINATED. RESET LT GENERATOR FIELD SWITCH, IAW AMM 24-11-01. ALL OPERATIONS NORMAL.
LEFT GEN TRIPPED, RAN QRH, RESET NORMAL. PERFORMED BPCU BITE, IAW B767 FIM 24-20 FT 801. NO FAULTS. THEN PERFORMED ENGINE RUN OF THE ENGINE NR 1. NO FAULTS. GEN OPERATES NORMAL.
DAMAGE FOUND ON AFT EDGE OF MCD DOOR SEAL DEPRESSOR. DAMAGE AT AFT EDGE OF MCD AT STATION 632 BETWEEN S-4L & S-13L, EXCEEDS SRM LIMITS. C/W PART 1 OF EO 6753A891 (TIME LIMITED REPAIR) APPLIED SPEED TAPE AT STA 632 MCD SEAL DEPRESSOR. PART 2 (DVI) INSPECTION EVERY 1 FLIGHT CYCLE. PART 3 (PERMANENT REPAIR) ON OR BEFORE 30 FLIGHT CYCLES. TRANSFERED TO NON-MEL MDDR NR 138029.
BTB LEFT ENGINE BLEED OFF EICAS ON CLIMBOUT, WOULD NOT RESET. PER FIM 36-20 F T 804 UP TO BLOCK 36. PERFORMED THUMB TEST, PER AMM 36-11-18. FOUND PRV LOCKOUT PIN LOOSE ALLOWING AIR TO ESCAPE. TIGHTENED LOCKOUT PIN, PER AMM 36-11-18-404-818-001. PERFORMED ENGINE RUN, PER AMM 71-00-00-00. OPERATIONS CHECKED GOOD. LEFT ENGINE SUPPLIED GOOD PRESSURE. PER FIM 36-20 FT 804 AND FIM 36-10 FT 832 BLOCK 21. REMOVED AND REPLACED PRESSURE REGULATING VALVE CONTROLLER, PER AMM 36-11-19. PERFORMED ENGINE RUN, PER AMM 71-00-00. NO HELP, REF LOG PG 1240981 ITEM 1 FOR CORRECTIVE ACTION.
AT FL360 LEFT RADAR SYSTEM AT 0 DEG TILT RETURNS SOLID RED BEYOND 80 NM. RIGHT RADAR SYSTEM RETURNS "NORMAL" GROUND CLUTTER AT SAME SETTING. SUSPECT LEFT RADAR TILT IS OUT OF CALIBRATION. PERFORMED WXR BITE, IAW FIM 34-43 FT 805, NO FAULTS NOTED. OPERATIONS CHECK GOOD. PERFORMED WXR OPERATIONS TEST, IAW AMM 34-43-00. OPERATIONS TEST GOOD.
LEFT ENGINE APPEARS TO BE STRUCK BY BIRD. DUE TO BIRD STRIKE ON NR 1 ENGINE CONDITIONAL INSPECTION REQUIRED. INSPECTED NR 1 ESN 702640 FOR BIRD STRIKE, IAW B767 AMM 72-00-00. FOUND NO DAMAGE BY BIRDSTRIKE WITHIN THE LPC OR HPC. C/W CONDITIONAL BIRD STRIKE INSPECTION, IAW 05-51-18. NO EVIDENCE OF DAMAGE NOTED. BIRD INGESTED INTO CORE OF NR 1 ENGINE ONLY.
FLIGHT DECK TEMP EICAS IN CRUISE. COMPLETED QRH PROCEDURE. PERFORMED BITE CHECK ON ZONE TEMP CONTROLLER, REF FIM 21-60 FT 805. NO FAULTS NOTED. MESSAGE CLEARED, OPERATIONAL CHECK NORMAL AT THIS TIME.
LEFT RADAR TILT APPEARS TO BE OUT OF CALIBRATION. EXCESSIVE GROUND CLUTTER IN CRUISE AT NORMAL TILT SETTINGS. RADAR TILT APPEARS TO BE LOWER THAN INDICATED. PERFORMED LT WX RADAR SYSTEM, REF FIM 34-43 FT 805. OPERATIONS CHECK NORMAL. COULD NOT DUPLICATE ON GROUND.
LT GEN OFF UPON LEFT ENGINE START. QRH COMPLETE. MAINTENANCE & DISPATCH NOTIFIED. PLACED ON MEL 136542, IAW AMM/DDG 24-00-01-01. CAT D, DUE 24OCT20. PERFORMED OPERATIONS CHECK OF LEFT ENGINE IDG, IAW AMM 24-11-00. OPERATIONS TEST GOOD. THIS CLEARS MDDR 136542. PLACARD REMOVED. MCC NOTIFIED.
RT ENGINE ANTI ICE VALVE LIGHT ON SHUT DOWN. C/W OPERATIONS CHECK OF RT ENGINE ANTI ICE SYSTEM, IAW AMM 30-21-00. OPERATIONS CHECK GOOD, NO FAULTS NOTED. OK FOR SERVICE.
"FWD EQ EXHAUST FAN" STATUS MESSAGE, INTERMITTENT "OVERHEAT" ANNUNCIATOR ON EQUIPMENT COOLING PANEL. CYCLED EQ COOLING TO STANDBY AND BACK TO AUTO. PERFORMED OPERATIONS TEST, IAW AMM 21-50-00. SYSTEM TEST OK, NO FAULTS FOUND.
RIGHT AFT FUEL PUMP PRESSURE EICAS AND LIGHT. TRANSFERRED TO MDDR NR 135738 MEL 28-22-01, CAT C D. I CW 2103Z 10OCT20, BWI MX. REMOVED AND REPLACED RIGHT AFT FUEL PUMP, AS PER B767-30-0 AMM 28-22-03/401 AND PERFORMED OPERATIONS CHECK, PER AMM 28-22-00/501 FOUND GOOD. THIS CLEARS DMI NR 135738. DISP DM 1246Z.
RT ENG OIL TEMP FLUCTUATING IN FLIGHT TO 0 DEG C, ALWAYS SHOWED LESS THAN LT ENGINE ON START. RT ENGINE OIL TEMP FLUCTUATING UP TO -17 DEG C. REMOVED AND REPLACED RIGHT ENGINE OIL TEMP SENSOR. OPS CHECKS GOOD, IAW AMM 79-34-01.
LT GEN OFF EICAS MESSAGE AFTER START, RAN QRH, EICAS CLEARED. STARTED ENGINES, IAW MM 71-00-00. LT GEN CHECK OK MM 24-11-00. IDG OIL OK, PER MM 12-13-03. OK TO CONTINUE.
APU FAULT ON FIRST ATTEMPT. REMOVED AND REPLACED APU CONTROL UNIT. OPERATIONS CHECKS NORMAL, IAW AMM 49-61-05.
APU FAULT ON FIRST ATTEMPT. TRANSFERRED TO MDDR 135610, PER DDG 49-11-01A. REMOVED AND REPLACED APU TRANSFORMER RECTIFIER UNIT, AS PER AMM 24-32-04 AND APU FAULT ANN SWITCH ASSEMBLY, AS PER AMM 33-16-02. OPERATIONAL CHECKS FOUND OK. THIS WILL CLEAR MDDR 135610.
RT AFT FUEL PUMP EICAS MESSAGE AND PRESS LT IN SWITCH ILLUMINATED AFTER PRESSURIZING AND TURNING FUEL PUMPS ON. TRANSFER TO MDDR 135436, IAW DDG 28-22-01, CAT "C", 13OCT20. DPI: EH 1720Z. PERFORMED CANNON PLUG CLEANING ON RT AFT FUEL BOOST PUMP, IAW AMM SWPM 20-60-01. RESET AND PERFORMED GFI FUNCTIONAL TEST, IAW AMM 28-22-00. OPERATIONS CHECKS NORMAL. NO EICAS MESSAGE NOTED. THIS CLEARS DMI 135436. MCC NOTIFIED. PLACARD REMOVED.
APU FAULT, NO FAULTS FOUND, COULD NOT DUPLICATE. APU STARTED ON GROUND. NO FAULTS FOUND. OPS CHECK, REF AMM 49-00-00.
APU FAILED TO START FIRST ATTEMPT AFTER LANDING. 785 EGT 29% RPM THEN SHUTDOWN AND "APU FAULT" MESSAGE. SUCCESSFUL SECOND START ATTEMPT. PERFORMED APU START PROCEDURE, OPS CHECK NORMAL, IAW AMM 49-11-00.
APU FAULT, CHRONIC APU STARTING ISSUES AFTER LANDING. PERFORMED APU BITE, IAW FIM 49-11 FT 958, NO FAULTS NOTED ON APU ECU AND NO FAULTS NOTED ON ECU SELF TEST. PERFORMED THREE SUCCESSFUL STARTS, IAW 49-11-00. OPERATIONS CHECKS NORMAL. DUE TO CHRONIC APU FIRST TIME STARTING ISSUE. TRANSFERED TO MDDR 135006, IAW MEL 49-11-01A, CAT C, DUE DATE 06OCT20. REMOVED AND REPLACED APU TRU, IAW AMM 24-32-04-404-003. OPERATIONS GOOD. THIS CLEARS MDDR 135006. PLACARD REMOVED.
APU FAULT WHEN STARTING UPON LANDING. PERFORMED APU BITE, IAW FIM 49-11 FT 958, NO MSGS NOTED OR FAULTS NOTED ON APU BOX. PERFORMED APU EXTERIOR INSPECTIONS, IAW AMM 49-21-00. NO LEAKS, CRACKS, TEARS, OR LOOSE CANNON PLUGS FOUND. PERFORMED 4 SUCCESSFUL STARTS, IAW AMM 49-61-05. WITH NO FAULTS FOUND.
WXR FAIL BOTH L/R SYS. REPLACED WXR RADAR ANTENNAE ASSY, PER AMM 34-43-05. OPS CHECK L/R WXR, SYSTEM CHECK GOOD.
APU GENERATOR NOT GOING OFF WHEN COMMANDED. REMOVED AND REPLACED APU GEN POWER BREAKER, IAW B767 AMM 24-22-03. OPS CHECK FAILED. FURTHER T/S REQUIRED. REMOVED AND REPLACED ELEC SYS CONTROL PANEL, IAW AMM 24-22-01. NO DEFECTS NOTED.
APU INOPERABLE, TRANSFERRED TO MEL 49-11-01A, MDDR #133991, CAT C. REMOVED AND REPLACED APU, IAW WORK CARD A-49-999-00-01. REVERSE FLOW MESSAGE ON ECU CLEARED. THIS CLEARS MDDR 133991, MCC NOTIFIED. PLACARD REMOVED.
APU SHUTDOWN TWICE PRIOR TO START, AFTER HYDRAULIC FUEL PUMPS TURNED ON. TURNED PACK OFF PRIOR TO THIRD HYD POWER UP, NORMAL START. PERFORMED APU BITE PER FIM 49-11 FT 958 "REVERSE FLOW" AS REASON FOR SHUTDOWNS. TIGHTENED INLET TEMP SENSOR FOR LCIT IAW FIM 49-11 FIG. 103, TABLE A AND AMM 49-61-03 OPERATIONAL TEST OF APU PASSED.
#4 SMOKE DETECTOR AMBER LIGHT ILLUM ON CARGO FIRE PANEL. CYCLED BREAKERS AND PERFORMED BYTE CHECK ON CARGO COMP SMOKE DETECTOR SYSTEM AS PER FIM TASK 26-19-00-815-803. OPS CHECK NORMAL AT THIS TIME.
APU INOP DUE (AUXILIARY POWER UNIT (APU),ER OPERATIONS NOT ALLOWED. REMOVED AND REPLACED APU GENETATOR SCAVENGE FILTER ELEMENT IAW TASK 49-27-03-004-001. REMOVED AND REPLACED APU SURGE VALVE FILTER IAW TASK 49-53-06-402-009. CHECKED OPS GOOD.
AFTER LOAD APPLIED TO HYD SYSTEM, APU AUTO FAULTED AND SHUT DOWN. PERFORMED APU BITE TEST IAW AMM 49-61-05. NO FAULTS NOTED, APU STARTED AND OPERATING NORMAL.
L FIELD GEN FLASHING DURING BITE CODE 44 BPCU FAULT FOUND. REMOVED AND REPLACED BPCU IAW 24-41-03. NO FURTHER DEFECTS NOTED AT THIS TIME
APU FAULT & SHUTDOWN PRIOR TO BLOCK OUT. C/W APU START AND RUN PROCEDURE, SYSTEM CHECKED GOOD AT THIS TIME IAW MM CH 49-11-00.
LEFT ENG BLEED AIR SWITCH OFF LIGHT REMAINS ILLUMINATED EVEN AFTER COMPLIANCE WITH DDG 30-21-P1-04-02 PROCEDURES. PERFORMED ENG RUN IAW AMM 71-00-00-862 .OPS CK GOOD. NO DEFECT NOTED. ALL PNEUMATIC CKS GOOD. A/C OK FOR SVC.
EICAS L ENG ANTI ICE AFTER ATTEMPTING TO TURN OFF. PERFORMED QRH IN FLIGHT. REMOVED AND REPLACED L/H ENGINE ANTI-ICE VALVE IAW AMM 30-21-03. OPS CK GOOD.
WHEN GPU POWER REMOVED, APU SHUT DOWN. RESTARTED NORMALLY. C/W APU OPS CHECK IAW AMM 49-00-00. OPS CHECK GOOD.
APU SHUTDOWN DURING PUSHBACK. PERFORMED A BITE ON THE APU ECU, NO CURRENT FAULTS, NORMAL STOP SIGNAL, APU STARTED SECOND ATTEMPT, NO FAULTS IAW AMM 49-61-00.
APU PNEUMATIC INOP (AUXILIARY POWER UNIT, PNEUMATIC FUNCTION). PERFORMED BITE CHECK OF SYSTEM PER AMM 49-61-05. NO FAULTS NOTED. APU START 1ST ATTEMPT. CB BREAKER S-23 C VALVE VERIFIED IN OFF POSITIONS PER 36-11-04. REMOVED AND REPLACED SURGE CONTROL VALVE IAW AMM 49-53-01. OPS CHECK NORMAL. NO AUTO SHUTDOWN. PERFORMED APU BITE IAW AMM 49-61-05. NO FAULTS NOTED. THIS CLEARS DMI 130515. PLACARDS REMOVED. MCC NOTIFIED.
INSTRUMENT COOLING SYSTEM, E1-E2 BALL NOT TESTING. REMOVED AND REPLACED THE E/E MONITOR INDICATOR IAW AMM 21-58-34. OPS TESTED OK.
WEATHER RADAR SYS LEFT AND RIGHT FAIL INDICATIONS. RESET WX RADAR C/B LT & RT. PERFORMED OPS CHECK IAW AMM 34-43-00. ALL CHECKS GOOD.
LT WING OB FLAP OB TRACK, LWR TRAILING EDGE ATTACH FITTING AT WBL 710 BROKEN. REMOVED AND REPLACED THE ATTACH FITTING ON THE LT WING OB FLAP TRACK TRAILING EDGE AT WBL 710 IAW SRM 51-40-02.
LEFT WING UPPER SURFACE OVERWING FILL PORT ADAPTER FLANGE HAS CORROSION. REMOVED CORROSION FROM LT WING UPPER FILL PORT ADAPTER FLANGE AND WAS FOUND OUT OF LIMITS IAW SRM 57-20--01-1A-1. REPAIRED OVERWING FILL PORT ADAPTER FLANGE IAW FAS EA 20017 REV IR.
AFTER TAKEOFF HAD SMOKE/FUMES IN COCKPIT(<P>PERFORMED SMOKE OR FUMES IN CABIN CONDITIONAL INSPECTION REF AMM 05-51-56. REMOVED OIL CONTAMINATION FROM THE AIR CONDITIONING AND PNEUMATIC SYSTEM REF AMM 21-00-21-102.</P><P>LP 1130723 - M6: REMOVED AND REPLACED LEFT ENGINE REF AMM 71-00-02. ENGINE RUN SATISFACTORY. NO LEAKS NOTED.</P>)
ON CLIMB OUT RECEIVED R FWD FUEL PUMP MESSAGE WITH PRESS LIGHT&NBSP;(<P>T/S IAW FIM 28-22 FAULT TREE 819 PUMP OPERATES NORMAL. ALSO T/S IAW FIM 28-41-FAULT TREE 854. NO FAULTS FOUND.</P>)
AFT EQ EXH FAN 2 EICAS MSG.(<P>TRANSFERRED TO MDDR 128074 PER MEL 21-58-05, CAT 'C', DUE DATE: 17MAY20. DISPATCHER: JT @18:24Z.</P><P>LP 1130713: REPLACED ECS FAN CONTROL MODULE M861 IAW AMM 21-58-24. CHKS GOOD. CLOSED MDDR 128074.</P>)
STRONG STINK ODOR FROM PACKS BELOW 10K FEET.(<P>TRANSFERRED TO MDDR 128086 IAW DDG 21-51-01-01, CAT 'C', DUE DATE 18MAY20, MAINT ACTIONS C/W. NOTE: MX VERIFIED SMELL STRONG FROM LEFT PACK, DEFERRAL IS FROM LEFT PACK ONLY. T&I JT0142Z.</P><P>LP&NBSP;1130707: PERFORMED INSPECTION OF L COOLING PACK IAW AMM 21-51-00, HEAT EXCHANGER & CONDENSERS, DUCTS ARE CLEAR OF FOD. NO SIGN OF FOUL SMELL. CLEANED OUT WATER FROM WATER SEPARATOR DRAIN IAW 21-51-21. SUPPLIED CONDITION AIR IAW AMM 21-00-00. NO FOUL SMELL. THIS CLEARS DMI 128086.<BR /></P>)
PACKS HAVE A VERY DIRTY SMELL ON TAKEOFF & APPROACH.(<P>ACCOMPLISHED OPS TEST OF COOLING SYSTEM THRU FULL TEMP RANGE IAW AMM 21-51-00. COULD NOT REPRODUCE SMELL ON GROUND.</P>)
BURNT OIL SMELL FROM AIR CONDITIONING SYSTEM WHEN THROTTLES ADVANCED FOR DEPARTURE AND ON DESCENT DURING 16K.(<P>PER CUSTOMER REQUEST, PERFORMED REMOVAL OF OIL CONTAMINATION PER B767 AMM 21-00-201 FROM THE AIR CONDITIONING AND PNEUMATIC SYSTEMS, VISUALLY INSPECTED RAM AIR INLETS AND L & R PACK BAYS AFTERWARDS IAW AMM 21-00-00. NO BURNT OIL SMELLS NOTED AND NO DISCREPANCIES FOUND. MCC NOTIFIED.</P>)
APU FAILED AND SHUTDOWN BEFORE ENG START(<P>PLACED ON MDDR 127985 PER MEL 49-11-01A, CAT 'C'.</P><P>08MAY20, BWI LP 1150050, ITEM M5: PERF APU BITE IAW FIM 49-11 FT 958. FOUND NO FAULTS. APU OPERATING NORMAL AND STARTING PARAMETERS SHOW NO SIGNS OF A BAD START. THIS CLEARS DMI 127985. DP @ 16:05Z.</P>)
L ENG BLEED OFF AFTER BOTH ENG STARTED. COMPLETE SHUTDOWN OF L ENG & RE-START BUT DID NOT CLEAR, RTB PARKING.(<P>REMOVED AND REPLACED L PRSOV VALVE I.A.W AMM 36-11-09. OPS CHECK GOOD.</P>)
R ENG NOSE COWL THERMAL ANTI ICE PRESSURE SWITCH IS DISCONNECTED AND HEAVILY CORRODED INSIDE CONNECTOR P/N 215N41-84.(<P>REMOVED AND REPLACED THERMAL ANTI ICE PRESSURE SWITCH IAW AMM 30-21-01/401 REV 129. OPS CHECK GOOD.</P>)
B LOOP ON CARGO DETECT INOP&NBSP;(<P>TRANSFERRED TO MDDR #126848 I.A.W MEL 26-16-02-01, CAT C.</P><P>LOG PAGE 1189953: PERFORMED BITE PROCEDURE ON MAIN DECK CARGO REF FIM 26-19 FT 803. NO MESSAGE NOTED. TEST PASS, MDDR #126848 CLOSED.</P>)
PRIOR TO ENGINE START, WITH SELECTION OF HYDRAULIC DEMAND PUMPS, APU AUTO SHUT DOWN DUE TO RIGHT EEC CB CHANNEL A.(<P>RESET CB, REF FIM 73-21 FT 885, NO FAULTS NOTED.</P><P>ITEM 2: APU STARTED FIRST ATTEMPT, NO APU WORK DONE, NO FAULTS NOTED. NO COLD SOAK REQUIRE. REF AMM 49-11-01.<BR DATA-MCE-BOGUS="1" /></P>)
APU FAULT ON START ATTEMPT. ATTEMPTED TWICE. 20 MAX RPM W/ NO EGT RISE.(<P>TRANSFERRED TO MDDR 126631 PER MEL 49-11-01A, CAT C, DUE DATE 13APR20. DI: JT @ 20:37Z.</P><P>BWI, 04APR, LP 1071367, ITEM M2: REMOVED AND REPLACED APU IGNITION EXCITER IAW AMM 49-41-03. REMOVED AND REPLACED APU ELEC IGNITOR LEAD (OFF P/N 3888076-2, NSN)&NBSP;IAW AMM 49-41-02, OPS CHECKED GOOD. THIS CLEARS MDDR 126631. PLACARD REMOVED, MX NOTIFIED.</P>)
ON WALK AROUND FOUND #1 PACK TEMP BULB BROKEN OFF DUCT #1 PACK INOP.(<P>TRANSFERRED TO MDDR #126206 I.A.W MEL 21-51-01-01, CAT 'C'.</P><P>LOG PAGE 1185224: INSTALLED NEW PRIM HX INLET TEMP BULB I.A.W AMM 21-52-08. OPS CHECK AND LEAK CHECK GOOD, MDDR #126206 CLOSED.</P>)
WX FAIL MESSAGE ON EHSI WITH LEFT WX RADAR SYSTEM SELECTED.(<P>PERFORMED WEATHER RADAR SYSTEM OPERATIONAL TEST, NO FOUL AT THIS TIME. L & R SYSTEM OPS CHECK GOOD AT THIS TIME.</P>)
ON DEPARTURE CLIMBING THRU 4000' +/- THE RIGHT FWD FUEL PUMP PRESS LIGHT ILLUMINATED, LIGHT EXTINGUISHED.(<P>PERFORMED FIM TASK 28-22 FAULT TREE 819, OPS CHECK GOOD AT THIS TIME.</P>)
RIGHT ENGINE STARTER SELECTOR LOOSE AND SLIDES OFF SHAFT.(<P>FOUND SELECTOR KNOB LOOSE. TIGHTENED LOCK SCREWS IAW AMM 20-11-00. SELECTOR SECURE, OPS GOOD.<BR /></P>)
"R FWD FUEL PUMP" EICAS MESSAGE SHORTLY AFTER LIFTOFF. FUEL IN TANK WAS APPROX 14.5.(<P>REMOVED AND REPLACED&NBSP;R FWD FUEL PUMP PRESSURE SWITCH IAW AMM 28-42-01. FUEL PUMP OPERATES NORMAL, NO FAULTS NOTED AT THIS TIME.</P>)
MAIN CARGO #2A SMOKE DETECTOR INOP.(<P>TRANSFERRED TO MDDR #124487 IAW MEL 26-16-02-02, CAT 'C', DUE 20FEB20.</P><P>LP 1188760, ITEM M2: REMOVED AND REPLACED #2A SMOKE DETECTOR IAW 26-19-01. OPS CHECK NORMAL, NO FAULTS NOTED. THIS CLEARS MDDR 124487.</P>)
RIGHT PACK INOP / (AIR CONDITIONING PACKS, -200/-300 (NOTIFY DISPATCH) (ER RESTICTIED R-60))(<P>TRANSFERRED TO MDDR #124209 PER DDG 21-51-01-01, CAT "C",&NBSP; DUE 12FEB20. MX PROCEDURE COMPLIED WITH.</P><P>LP 929492: REMOVED AND REPLACED RIGHT RAM AIR INLET DOOR ACTUATOR IAW AMM 21-53-03, OPS CHECK OK. THIS CLEARS MDDR 124209.</P>)
NO APU PNEUMATIC PRESSURE FROM APU, PERFORMED AIR STARTS, APU IS GOOD. PERFORMED APU BITE TEST IAW FIM 49-11 FT 958. FAULTED P2 SENSOR. REPLACED THE SENSOR IAW AMM 49-61-04. NO HELP. REPLACED ECU IAW AMM 49-61-05. OPS CHECKED GOOD. NO DEFECTS NOTED.
AFT EQUIPMENT EXHAUST FAN 2 STATUS MSG.(<P>RESET AFT EQUIPMENT EXHAUST FAN 2 C.B. AND PERFORMED OPS TEST. OPS CHECK GOOD. MSG REMAINS EXTINGUISHED, REF B767 AMM 21-58-41-710-002-002. NO FURTHER DEFECTS NOTED.</P>)
NO PNEUMATIC WITH APU RUNNING. REMOVED AND REPLACED APU BLEED AIR SHUTOFF VALVE IAW AMM 36-11-10. OPS CHECK GOOD.
APU FAILED TO START. TROUBLE SHOT IAW FIM 49-11, REMOVED AND REPLACED ECU IAW AMM 49-61-03. OPS CHECK GOOD AT THIS TIME. (NOTE: OPENED A DMI 123422 IAW DDG 25-AP-01, OPTION C - FOR APU COLD SOAK START VERIFICATION)
NOTED EXTERIOR BLEED AIR NOISE COMING FROM LEFT MAIN GEAR DOOR AREA. FOUND CRACK AT FLANGE IN APU BLEED AIR DUCT. REMOVED AND REPLACED APU BLEED AIR DUCT ELBOW FWD OF APU SOV (CTR ISOL VLV), CHECKED FOR AIR LEAKS. NO AIR LEAK NOTED. REF AMM 20-11-00.
AFTER TAKEOFF - RT FWD FUEL PUMP EICAS MESSAGE & ASSOCIATED LOW PRESS LIGHT ILLUMINATED MOMENTARILY. PERFORMED OPS CHECK ON ALL FUEL PUMPS IAW AMM 28-22-00. OPS CHECK GOOD.
APU FAILED TO START ON 2 ATTEMPTS AFTER LANDING.(<P>PERFORMED ECU BITE CHECK I.A.W AMM 49-61-05. NO LIGHT OFF FAULT, PERFORMED APU OPERATIONAL TEST I.A.W AMM 49-11-00. NO DEFECTS NOTED.</P>)
APU INOP ( AUXILIARY POWER UNIT (APU), ER OPERATIONS NOT ALLOWED (NOTIFY DISPATCH) R60 )(<P>TRANSFERRED TO MDDR 122826, MEL 49-11-01A, CAT 'C', DUE 10JAN20.</P><P><SPAN>LP 1205918: REMOVED AND REPLACED APU FUEL VALVE CONTROL ASSY IAW AMM 49-31-01. OPS CHECK GOOD. NO LEAKS NOTED. THIS CLEARS MDDR 122826. PLACARD REMOVED.</SPAN><BR /></P>)
MAIN CARGO FIRE SMOKE DETECTOR A2 STATUS LIGHT ILLUMINATED AMBER.(<P>T/S PER FIM 29-16 FT 803, FAULTS CLEARED, SYS TESTS OK AT THIS TIME&NBSP;IAW&NBSP;<SPAN>AMM 26-16-00.</SPAN><BR /></P>)
INERTIAL REEL POSITION B UNSERVICABLE. REMOVED AND REPLACED DESCENT DEVICE INERTIAL REEL B IAW AMM 25-61-05, NO DEFECTS NOTED.
ONE DESCENT DEVICE DEPLOYED AND REMOVED.(<P>TRANSFERRED TO MDDR #120939 IAW MEL 25-61-01-01, CAT 'C', DUE DATE: 01-DEC-2019.&NBSP; PLACARD INSTALLED AND MX DDG PROCEDURE C/W.&NBSP;</P><P>LP&NBSP;1097349 - M4; INSTALLED NEW DESCENT DEVICE 1 EA IAW AMM 25-61-05. THIS CLEARS MDDR 120939. PLACARDS REMOVED AND MCC NOTIFIED.</P>)
APU INOP DUE TO NUMEROUS ECU FAULTS PER POWERPLANT ENGINEERING.(<P>TRANSFERRED TO&NBSP;MDDR 120639 PER MEL 49-11-01A, CAT 'C'.<BR /></P><P>LP 1223288 - M5: REMOVED AND REPLACED INLET GUIDE VANE ACTUATOR REF B767 AMM 49-52-02, OPS CHECK GOOD. THIS CLEARS DMI 120639. PLACARD REMOVED AND MCC NOTIFIED.</P>)
EMERGENCY DECENT DEVICE EXTENDED ON LANDING.&NBSP;(<P>TRANSFERRED TO MDDR 120649 PER MEL 25-61-01-01, CAT 'C', C/W DDP. REMOVED AFFECTED ESCAPE DEVICE.</P><P>LP 1223283 - M4: INSTALLED&NBSP;EMERGENCY DESCENT DEVICE IAW B767 AMM 25-61-05, NO FURTHER DEFECTS NOTED. THIS CLEARS DMI #120649. MCC NOTIFIED AND PLACARD REMOVED.</P>)
AFTER LANDING; APU START EICAS MSG, APU FAULT.(<P>PERFORMED VISUAL CHECK OF THE APU OIL NOT VISIBLE IN SIGHT GLASS. SERVICED APU IAW AMM 12-13-04 AND PERFORMED APU OPERATIONAL CHECK; OPS CHECK GOOD AT THIS TIME. VERIFIED OIL CAP IS INSTALLED. NO LEAKS NOTED.</P><P>NOTE: LP 1111482 - M5: APU COLD SOAK START VERIFICATION MDDR 120552 OPENED DUE TO ITEM ABOVE.</P><P>LP 1111484 - ITEM 2: APU COLD SOAK START ATTEMPTED FL 360, SAT -58 C, 0853Z, START SUCCESSFUL ON FIRST ATTEMPT. THIS CLEARS MDDR 120552. PLACARD REMOVED AND MCC NOTIFIED.&NBSP;</P>)
LH WEATHER RADAR SYSTEM INOP(<P>PERFORMED WX BITE TEST, SYSTEM FAILED. ITEM TRANSFERRED TO MDDR 120536 AS PER ATLAS DDG 34-43-01, CAT 'D'.</P><P>LP 1111492 - M5: REMOVED AND REPLACED LT WX TRANSCEIVER&NBSP;IAW B767-300 AMM 34-43-01. OPS CHECKED NORMAL IAW 34-43-00. THIS CLEARS&NBSP; MDDR 120536, PLACARD REMOVED.</P>)
ESCAPE REEL DISLODGED ON LANDING.(<P>TRANSFERRED TO DMI #120498 IAW MEL 25-61-01-01, CAT 'C', DUE 22-NOV-19.&NBSP;</P><P>LP 1111478 - M5: INSTALLED DESCENT DEVICE POSITION "B" IAW AMM 25-61-03. THIS ACTION CLEARS DMI #120498.&NBSP;PLACARD REMOVED.</P>)
DESCENT REEL C FELL OUT OF ITS CONTAINER.(<P>REMOVED AND REPLACED #3 DESCENT DEVICE REEL IAW B767 AMM 25-60-05.</P>)
RADAR WAS FLASHING.(<P>COMPLETED FUNCTION TEST IAW AMM 34-43-00, OPS CHECK GOOD AND NO FAULTS FOUND.&NBSP;</P>)
LEFT ENGINE BLEED OFF LIGHT INOP.&NBSP;(<P>TRANSFERRED TO MDDR #119157 IAW MEL 36-21-02, CAT 'C'.&NBSP;</P><P>LP 1098127 - M3: REMOVED AND REPLACED L ENG BLEED KORRY LIGHT SWITCH IAW AMM 33-16-02. THIS CLEARS MDDR #119157. MCC NOTIFIED.&NBSP;</P>)
AFT CARGO STATION 1150, FIRE EXTINGUISHER NOZZLE BLOCKED. REMOVED OBSTRUCTION FROM NOZZLE AS PER AMM 26-23-00, ALL OTHER NOZZLES OK.
AFTER ENGINE START, RT ENGINE IGNITION SWITCH REMAINED IN GND POSITION. NO VALVE LIGHT ILLUMINATED, NO EICAS MESSAGE ILLUMINATED. REMOVED AND REPLACED ENGINE IGNITION AND STARTING PANEL IAW AMM 80-11-51. OPS CHECK SUCCESSFUL, NO DEFECTS NOTED.
FOUND STBY POWER BATTERY TEST LIGHT NOT ILLUMINATED.(<P>REMOVED AND REPLACED STBY POWER BATTERY PANEL IAW AMM 24-33-04, OPS TEST OK.&NBSP;</P>)
APU INOPERATIVE. PERFORMED APU BITE PER FIM 49-11 FT 958, FOUND NO FAULTS. APU STARTED AND OPERATED NORMAL IAW AMM 49-11-00-802-002. REMOVED AND REPLACED APU CONTROL UNIT (ECU) IAW AMM 49-61-05. OPS AND BITE CHECK GOOD AT THIS TIME.
FORWARD EQUIPMENT VALVE EICAS MESSAGE DISPLAYED. T/S SYSTEM, FOUND SHUT-OFF 3 WAY VALVE INOPERATIVE. REMOVED AND REPLACED SHUT-OFF 3 WAY VALVE IAW AMM 21-58-01. OPS AND LEAK CHECKS GOOD.
APU WOULD NOT START AFTER LANDING. 2 ATTEMPTS, APU FAULT BOTH TIMES.(<P>PERFORMED BITE TEST OF APU ECU. LAST RUN, LOW OIL PRESS MESSAGE. CHECKED APU OIL LEVEL, FOUND TO BE LOW. SERVICED OIL IAW AMM 12-13-04 TO FULL. ECU BITE TEST IAW AMM 49-61-05. RAN APU, EXTERNAL LEAK CHECK OK, AND SUBSEQUENT BITE TEST OK.</P>)
APU FAILED DURING START AND APU FAULT EICAS MESSAGE OCCURRED.&NBSP;(<P>PERFORMED BITE TEST ON APU CONTROLLER, NO FAULTS NOTED. STARTED APU ON FIRST ATTEMPT, NO EICAS MESSAGE PER AMM 49-11-00.</P>)
REF MEL 25-AP-01 APU COLD SOAK START UNSUCCESSFUL - 2 ATTEMPTS, FL 410, SAT -59ðC, (APU STARTED - RUN MOMENTARILY THEN "APU FAULT" EICAS & SHUTDOWN).&NBSP;(<P>LP 1223468 - M6:&NBSP;WIND MILLED #1 ENG, PUT APU IN MES MODE AND CHECKED SURGE VALVE POSITION. IT WAS NEAR CLOSED BUT NOT FULLY CLOSED. PERFORMED BITE CHECK AND GOT A LOW OIL PRESSURE BITE. DMI 118222 REMAINS OPEN. REF FIM 49-11 FAULT TREE 966.</P><P>LP 1223470 - ITEM 1:&NBSP;APU RELIABILITY COLD START ACCOMPLISHED ON FLIGHT LEG CVG-ONT SAT 49 C FL 360 ,START SUCCESSFUL ON 2ND ATTEMPT.&NBSP;NOTED BY MX. THIS CLEARS DMI 118222. PLACARDS REMOVED. PERFORM APU BITE PROCEDURE IAW FIM 49-11 FT 958. NO FAULTS NOTED. MCC NOTIFIED.&NBSP;</P>)
R FWD FUEL PUMP EICAS MESSAGE AFTER ROTATION. MESSAGE EXTINGUISHED AT APPROX 3,500 FEET. T/S RIGHT FWD FUEL PUMP EICAS MESSAGE IAW FIM 28-22 FT 819. REMOVED AND REPLACED RIGHT FWD FUEL PUMP PRESSURE SWITCH IAW AMM 28-42-01. OPS CHECK NORMAL, NO EICAS MESSAGE AT THIS TIME.
FUEL CONFIG EICAS MSG AS A RESULT OF WRITE UP #1. AFTER ROTATION, APPROX 1, 800 LBS IMBALANCE. FUEL BALANCED WHEN PUMP TURNED BACK ON. DUE TO HISTORY, REMOVED AND REPLACED R FWD BOOST PUMP IAW AMM 28-22-03. OPS CHECK NORMAL AT THIS TIME, NO LEAKS NOTED.
R FWD FUEL EICAS DURING DURING CLIMB. FUEL MIGRATION FROM R TO L FUEL TANK OF 3000 LBS. T/S EICAS R FWD FUEL PUMP MESSAGE PER FIM TASK 28-22 FT 819, SHEET 3, BOX #4. DEFERRED R FWD BOOST PUMP PER MEL 28-22-01. THIS OPENS MDDR 117781. MCC BOB NOTIFIED, ALL PLACARDS INSTALLED. LP 1076167 - M3: T/S IAW FIM 28-22 FT 819. REMOVED RT FWD FUEL PUMP PRESSURE SWITCH TO BLEED PRESSURE SENSE LINE PER FIM IAW AMM 28-42-01. REINSTALLED RT FWD FUEL PUMP PRESSURE SWITCH AND OPS CHECK GOOD. NO DEFECTS NOTED, MDDR 117781 CLOSED. PLACARDS REMOVED AND MCC NOTIFIED.`
ON THE FIRE PNL HANDLE, FOUR SW LIGHTS: L ENG OVHT, ENG BTL 1 DISCH, ENG BOTTLE B DISCH, AND R ENG OVHT ASSY ARE NOT WORKING PROPERLY, STUCK AND STICKING. REMOVED AND REPLACED FIRE/OVERHEAT TEST PANEL IAW AMM 26-11-01, OPS CHECK NORMAL.
EXTERIOR LOWER FUSELAGE EMERGENCY LIGHT INOP DURING TEST. FOUND PIN 1 PUSHED BACK AT CONNECTOR D6330P. RE-SECURED PER SWPM 20-60-06. OPS CHECK GOOD PER AMM 33-51-00.
#2 ENGINE IDG SERVICING FITTING LEAKING. REMOVED AND REPLACED #2 ENGINE IDG SERVICING FITTING IAW AMM 24-11-00. LEAK CHECK GOOD.
AFTER DEPARTURE, RECEIVED R FWD FUEL PUMP & FUEL IMBALANCE EICAS MSG. LEFT WING HAD 3,000 LBS LESS THEN RIGHT TANK, WE WERE GOING TO RUN QRH PROCEDURES THEN FUEL BALANCED OUT AND EICAS MESSAGES WENT AWAY. MONITORED FUEL IN BOTH MAIN TANKS FOR 4 HRS, NO UNWANTED FUEL TRANSFER NOTED. COMPLIED WITH FQI BITE PER FIM 28-41 FT 882, NO FAULTS NOTED. ACCOMPLISHED FUEL CONFIG MSG FIM 28-41 FT 884, NO FAULTS NOTED. ALL BOOST PUMPS OPS CHECK NORMAL PER AMM 28-22-00.
RIGHT WXR RADAR FAIL. OPS TEST GOOD IAW AMM 34-43-00. NO FAULTS FOUND AT THIS TIME.
R FWD FUEL PUMP AND FUEL CONFIG LIGHT EICAS CAME ON DURING CLIMB OUT. LEFT FUEL QUANTITY INDICATION ROSE APPROXIMATELY 3000 LBS FOR 2-3 MIN, THEN RETURNED TO NORMAL PERFORMED FQIS BITE PROCEDURE, NO PRESENT LEG FAULTS. FUEL QTY INDICATING SYSTEM OPS CK NORMAL. OK FOR SERVICE IAW B767 FIM 28-41-00.
FO SIDE TERRAIN INOP. FO SIDE WX RADAR ALSO REQUIRES WX RADAR TO BE PUSHED MULTIPLE TIMES.&NBSP;&NBSP;(<P>TRANSFERRED TO MDDR 114890 PER MEL 34-22-05B.</P><P>LP 1053563 - ITEM 1:&NBSP;VERIFIED SYMBOL GENERATOR ISOLATION IAW AMM 34-22-05B VERIFY EACH FLIGHT DAY. DMI 114890 REMAINS OPEN FOR FO'S TERRAIN: WEATHER SWITCHES.</P><P>LP 1086165 - ITEM 1:&NBSP;PERFORMED SYS GEN SOFTWARE UPDATE IAW AMM 34-22-00. OPS CHECK GOOD. WX RADAR TERRAIN ON F.O.'S SIDE OPS CHECK GOOD. THIS CLEARS DMI 114890. PLACARD REMOVED AND MCC NOTIFIED.&NBSP;</P>)
APU SLOW TO START AND FAILED TO START. (<P>REMOVED AND REPLACED APU ECU WITH NEW. OPS CHECK GOOD. REF AMM 49-61-05<BR /></P>)
ON DEPARTURE AMBER EICAS RT FWD FUEL PUMP&NBSP;(<P>PERFORMED OPS CHECK OF RT FWD FUEL PUMP&NBSP; IAW AMM 28-22-00 OPS CHECK GOOD NO DEFECT NOTED</P>)
NO AURAL WARNING BELL AND MASTER CAUTION LIGHT WHEN DOING WHEEL WELL ENG APU CARGO FIRE OVHT TESTS(<P><SPAN>REPLACED / CA MASTER CATION WARNING SWITCH IAW SWPM 20-84-18 PERFORMED FIRE OVHT TEST IAW AMM 26-17-00 PS TEST GOOD</SPAN><BR /></P>)
WX FAILED HSI MESSAGE, USING RT WX SYSTEM. REMOVED AND REPLACED WX CTRL PANEL IAW AMM 34-43-02, OPS CHECK GOOD.
RIGHT WEATHER RADAR INOP LEFT RADAR OPERATES NORMAL(<P>TROUBLESHOT PER FIM 34-43 FT 805. SUSPECT FAULTY RH TRANSCEIVER. NO PARTS AVAILABLE. DEFERRED IAW MEL 34-43-01, CAT 'D', DUE 05OCT19, DMI #112842. MCC AND DISPATCH NOTIFIED. REMOVED AND REPLACED RIGHT WEATHER RADAR TRANSCEIVER IAW B767 AMM 34-43-01. OPS CHECK OK AT THIS TIME. MCC NOTIFIED.
STDBY ENGINE INDICATOR BACKGROUND LIGHT INOP. REMOVED AND REPLACED STANDBY ENGINE INDICATOR IAW B767 AMM 77-41-01. OPS CHECKED GOOD.
APU TOOK 3 ATTEMPTS TO START. PERFORMED AUX POWER CONTROL UNIT BITE TEST. TEST PASS, NO FAULTS SHOWN. OPS NORMAL AS PER AMM 49-11-00.
LEFT PACK AIR CYCLE MACHINE WITH AIR LEAK AND HARDWARE MISSING. (<P>REMOVED AND REPLACED LEFT PACK AIR CYCLE MACHINE IAW AMM 21-51-03. OPS CHECK GOOD. NO LEAKS NOTED AT THIS TIME. </P><P><BR DATA-MCE-BOGUS="1" /></P><P>PACKING P/N: S9028T906</P><P>SEAL P/N: 460-400</P>)
MAIN BATTERY CHARGER STATUS MESSAGE.(<P>T/S PER FIM 24-31 FT 804. NO FURTHER FAULTS NOTED AT THIS TIME.</P>)
RIGHT RADAR UNABLE TO CONTROL PITCH ON THE GROUND. (<P>PERFORMED OPS CHECK OF RT WX RADAR SYSTEM IAW AMM 34-43-00. OPS CHECK NORMAL AT THIS TIME.</P>)
AFTER T/O AMBER ADVISORY MESSAGE, R FWD FUEL PUMP MESSAGE (CLEARED PASSING 7000). LP 1033533-3: AFTER T/O & AFTER RT FWD FUEL PUMP LOW PRESS, FUEL CONFIG WARNING, LEFT FUEL TANK INDICATED A 3000+ LB IMBALANCE. LP 1033534 - 3: 3000 LB IMBALANCE WITH L TANK SHOWING 9000 LB + RT TANK SHOWING 12.4, MADE LEFT TURN AND IMBALANCED DISAPPEARED AND FUEL CONFIG MSG CLEARED.&NBSP;(<P>REMOVED AND REPLACED RH FWD BOOST PUMP PER AMM 28-22-03. OPS CHECK GOOD AND LEAK CHECK GOOD.</P>)
NR 2 MAIN DECK SMOKE DETECTOR "A" FAILED ( AMBER LIGHT)&NBSP;(<P>TRANSFERRED TO MDDR 111153 CAT "C" AS PER MEL 26-16-02-01.&NBSP;</P><P>REF LOG PAGE 1065595 ITEM M4; REMOVED AND&NBSP;REPLACED THE NR 2 MAIN DECK DETECTOR IAW AMM 26-19-01. PERFORMED OPS CHECK GOOD AMBER LIGHT EXTINGUISHED, THIS CLEARS MDDR 111153&NBSP;</P>)
R ENG ANTI-ICE VALVE LIGHT ON AFTER ENG SHUTDOWN WITH SWITCH OFF(<P>C/W OPS TEST IAW AMM 30-21-03. OPS TESTS GOOD</P>)
R ENG FIRE LP 2 STATUS MSG.(<P>T/S PER AMM 26-11-00, NO FAULTS&NBSP; NOTED. NO MESSAGES AT THIS TIME C/W DVI, NO FAULTS DETECTED.&NBSP; DUE TO HISTORY, TRANSFERRED TO MDRR # 110870.&NBSP; PLACARD INSTALLED.&NBSP;</P><P>LP 1065574 - 5:&NBSP;INSPECTED FIRE LOOP, ENG NR 2 HARNESS AND CLAMPS FOR SHOT WIRES PER SWPM 20-10-06. NO DEFECTS NOTED. NR 2 ENG FIRE TEST GOOD PER FIM 26-11-00 TASK 804. MDDR 110870 STILL VALID.</P><P>LP 1065582 - M5:&NBSP;PERFORMED SWAP OF RT ENG FIRE LOOP CARDS M683 AND M684 PER WDM 26-11-21 SHEET 2. NO STS MSGS WERE ON THE EICAS. OPS CHECK OF THE FIRE LOOP SYSTEM TESTED OK. REF USED 26-21-00-705-001 MDDR OPEN FOR FURTHER TROUBLESHOOTING.</P><P>LP 1065583 - M2:&NBSP;PILOTS NOTED NO MSG'S DURING FLT. NO MSG'S CURRENTLY NOTED, DMI REMAINS OPEN.</P><P>LP 1065588 - M3:&NBSP;CREW REPORTS NO FURTHER MESSAGE FOR R ENG LP 2. THIS CLEARS DMI # 110870. DISPATCH AND MCC NOTIFIED.&NBSP;</P>)
"R ENG FIRE LP 2" STATUS MESSAGE SHORTLY AFTER TAKEOFF. (<P><SPAN>PERFORMED VISUAL INSPECTION OF R ENG LP 2. NO DAMAGE NOTED IAW FIM 26-11 FAULT TREE 804 BLOCK 3.</SPAN><BR /></P>)
STATUS R ENG FIRE LOOP 2 PERFORMED FIM 26-11 FT 804 PER BLOCK 103. C/W VISUAL INSPECTION OF ENG LOOP 2 AND BLEED DUCTS, NO LOOSE CONNECTIONS AND NO DAMAGE NOTED. OPS CHECK, NO FURTHER DEFECTS NOTED.
FWD R/H COWLING FAN STRUT SEIZED ENG #2.(<P>REMOVED AND REPLACED FWD RH FAN COWLING STRUT PER AMM 71-11-11 CHECK NORMAL.</P>)
LOWER FWD CARGO SMOKE DETECTION SYS INOPERATIVE. PERFORMED FIM 26-16 FAULT TREE 814. FOUND BLOWER 2 INOP. T/S PER FIM 26-16 FT 814 EICAS MSG CARGO DET AIR. REMOVED AND REPLACED AFT CARGO AIR DETECT PRESSURE SWITCH IAW AMM 26-16-03, OPS CHECK GOOD FOR SWITCH BUT SUSPECT FWD NR 1 BLOWER IS INOPERATIVE. TS PER SRM 26-16-01, VERIFIED FWD 1 BLOWER MOTOR IS SETTING POWER AND MOTOR DOES NOT RUN. REMOVED AND REPLACED AFT SMOKE DETECTOR BLOWER 1 IAW AMM 26-16-02. NO HELP. REMOVED AND REPLACED AFT SMOKE DETECTOR PLENUM PRESSURE SWITCH S4-55 IAW AMM 26-16-03. NO HELP. R & R BLOWER 1 FOR CARGO DET AIR IAW AMM 26-16-02.
RH ENG FIRE LOOP 1 STATUS MSG. REMOVED AND REPLACED LOWER AFT FIRE EDT ELEMENT ON # 2 ENG IAW AMM 26-11-02. OPS CHECK GOOD. R ENG FIRE LP 1 STS MSG, T/S PER AMM 26-11-00. NO FAULTS FOUND AT THIS TIME. C/W DVI, NO FAULT FOUND AT THIS TIME. PER NOTED HISTORY, SWAPPED AFOLTS CARDS M681. STATUS MESSAGE SWAPPED TO NR 1 ENG BUT NR 2 EMGINE MESSAGE STILL DISPLAYED. RETURNED CARDS TO ORIGINAL POSITIONS. R & R R ENG UPPER AFT FIRE DETECTOR LOOP IAW AMM 26-11-02. FIRE WARN TESTS OK, NO MSG.
L FRONT WINDOW PANE SHATTERED IN FLIGHT.(<P>REMOVED AND REPLACED L1 WINDOW IAW AMM 56-11-01 STEPS 1 THRU 18 B. SEE LOG PAGE 1024159 ITEMS M7 AND M8&NBSP; FOR FINAL STEPS. </P><P>LP 1024159 - M7:&NBSP;PERFORMED SECOND TORQUE OF THE L1 WINDOW IAW AMM 56-11-01.&NBSP;SEE LOGPAGE 1024159 ITEM M8 FOR FINAL TORQUE. </P><P>LP 1024159 - M9:&NBSP;PERFORMED STEPS 23-39.&NBSP; INSTALLATION OF L1 WINDOW IS COMPLETE.&NBSP; OPS CHECK OF WINDOW HEAT ARE GOOD. REF 767 AMM 56-11-01.</P>)
01 INERTIAL ESCAPE REELS INOP ( 6 OPERATIONAL).(<P>PLACED ON MDDR 110082 PER MEL 25-61-01-01.&NBSP;</P><P>LP 1024155 - M5:&NBSP;INSTALLED DESCENT DEVICE IAW AMM 25-61-05. NO FURTHER DEFECTS NOTED AT THIS TIME. THIS CLEARS DMI 110082 PLACARDS REMOVED.</P>)
R ENG FIRE LP 1 STATUS MSG.(<P>PERFORMED OPS CK OF RIGHT ENG FIRE LP 1 PER FIM TASK 26-11 FT 804. UNABLE TO DUPLICATE, NO FAULTS FOUND.<BR /></P>)
RIGHT FWD FUEL PRESS ADVISORY DURING INITIAL CLIMB.(<P><SPAN>PERFORMED OPS CHECK OF RT FWD FUEL PUMP IAW AMM 28-22-00. OPS CHECK GOOD AT THIS TIME.</SPAN></P>)
NR 2 ENGINE VIBE INDICATION INOP(<P>TRANSFER TO MDDR # 108505 IAW DDG 77-31-01-01 CAT C DUE DATE 21 MAR-19</P><P>LP 1015904-4: REPLACED N2 ACCELEROMETER CONNECTOR 3 PINS. OPS CHECK GOOD&NBSP;IAW SWDM 20-36-03.&NBSP;THIS ACTION CLOSES MDDR 108505, MCC NOTIFIED AND STICKERS REMOVED.<BR /></P>)
APU FAULT AFTER LANDING AND ATTEMPTING TO START APU .(<P>TRANSFERRED TO MDDR # 108134 AS PER MEL 49-11-01A CAT C. REMOVED AND REPLACED STARTER MOTOR IAW AMM 49-41-01 OPS CKS NORMAL.</P>)
F/O EMERGENCY ESCAPE ROPECOVER DOOR WILL NOT REMAIN CLOSED.(<P>RE-STOWED EMERGENCY ESCAPE ROPE IAW 25-60-00 DOOR NOW REMAINS CLOSED.<BR /></P>)
WHILE PERFORMING BOOST OVERRIDE ON A JETTISON PUMP TASK CARD, CHECK FAILED AT STEP C.3, LEFT JETTISON NOZZLE OPENED DURING CHECK. RESEATED THE LEFT JETTISON NOZZLE ACTUATOR IAW AMM 28-31-05, PEFORMED A GOOD OPS CHECK IAW AMM 28-31-00.)
NR 2 ENGINE LP COMPRESSOR ROTOR BLADE NR 1 HAS A NICK AT L/E CONTOUR. INSPECTED AND FOUND TO BE .0003" IN DEPTH, MAX ALLOWABLE .060". NR 1 FAN BLADE FOUND TO BE IN LIMITS AND SERVICEABLE IAW AMM 72-31-02-226-019.
NR 2 ENGINE LP COMPRESSOR ROTOR BLADE NR 20 HAS A NICK AT L/E CONTOUR. BLENDED THE NICK AND RAISED MATERIAL ON THE NR 2 FAN BLADE 20, MATERIAL LOSS AFTER REPAIR .028,MAX ALLOW .060, VERFIED CONDITION OF BLADE VIA NDT, BLADE FOUND TO BE SERVICEABLE, NO FURTHER ACTION REQUIRED IAW AMM 72-31-02.
RIGHT FWD BOOST PUMP PRESSURE SWITCH S72 AND CONNECTOR D01532 ARE SEIZED TOGETHER. REMOVED AND REPLACED THE BOOST PUMP PRESSURE SWITCH S72 AND CONNECTOR D01532 IAW WDM 28-42-1, AND AMM 28-42-01. PERFORMED SATISFACTORY OPS CHECK.
EXTERNAL POWER INOPERATIVE. REMOVED AND REPLACED THE INTERLOCK FUSES AND PERFORMED AN OPS CHECK IAW AMM 24-41-00. THIS CLEARS MDDR #107609 PLACARD REMOVED,<BR /></P>)
STBY ENG INST. INOP(<P>PERFORMED BITE TEST.OPS TEST NORMAL IAW B767 AMM 77-41-00. PERFORMED ENGINE RUNS IAW B767 AMM 71-41-00-00, OPS CHECKS NORMAL IAW B767 AMM 71-41-00. DESCRIPTION AND OPERATION WHEN IN "ON" POSITION POWER IS SUPPLIED THRU ENGINES RUNNING OR EEC MAINT SWITCH "TEST".</P>)
STATUS MESSAGE, "FWD EQ EXH FAN". REMOVED AND REPLACED FWD EQ EXH FAN IAW AMM 21-58-06. FAN OPS CHECK NORMAL.
TWO ESCAPE REELS DEPLOY.(<P>INSTALLED 2EA DESCENT DEVICES IAW AMM 25-61-01 THIS ACTION CLEARS MDDR 106844 PLACARD REMOVED. INSTALLED SN 11554, 26272 PN 379103D-29<BR /></P>)
ONE EACH INERTIAL ESCAPE REEL INOP. TRANSFERRED TO MDDR 106759.&NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP;&NBSP;(<DIV>REPLACED REEL DECENT DEVICE. THIS ACTION CLOSES MDDR 106759.</DIV>)
RIGHT IDG INOP.&NBSP;(<P>TRANSFER TO MDDR # 106390 IAW DDG 24-00-01-01- CAT B DUE DATE&NBSP; 28-JAN-19</P><P>LP 1040367-M3 REMOVED AND REPLACED RT IDG IAW AMM 24-11-01 PERFORMED OPS CHECK IAW AMM 24-11-00 OPS CHECK GOOD THIS CLEARED MDDR 106390.</P>)
RIGHT A/C BUS FAILED INFLT DESCENDING BELOW 240&NBSP;(<P>PERFORMED OPS CHECK IAW AMM 24-22-00 OPS CHECK NORMAL AT THIS TIME NO FURTHER DEFECTS NOTED&NBSP;</P>)
ESCAPE REEL FELL FROM HOUSING.(<P>TRANSFER TO DMI 106237 PER MEL 25-610-01-01. <BR /></P><P>INSTALLED NEW ESCAPE REEL IN POSITION B IAW AMM 25-61-00 THIS CLOSES DMI 106237<BR /></P><P>REMOVED PART WAS REMOVED AT THE TIME OF OCCURRENCE. THERE IS NO OFF UNIT RECORDED.<BR /></P>)
FWD EQ EXH FAN STATUS MESSAGE AFTER LANDING&NBSP;(<P>TRANSFERRED TO MDDR # 105939 AS PER MEL 21-58-04-02-01 CAT C&NBSP;</P><P>LP 1032286-M3: R/R FORWARD EQUIP EXHAUST FAN ASSEMBLY. OPS CHECK GOOD. STATUS MESSAGE EXTINGUISHED IAW AMM 21-58-06. THIS CLEARS DMI #105939.</P>)
EMERGENCY ESCAPE DEVICE FELL FROM CEILING COMPARTMENT&NBSP;(<P>TRANSFERRED TO MDDR # 105800 AS PER MEL 25-61-01-01 CAT C.</P><P>LP 1047509-M3: INSTALLED&NBSP;NEW EMERGENCY&NBSP;DECENT DEVICE IAW AMM 25-61-05.&NBSP;THIS ACTION CLOSES DMI 105800, MCC NOTIFIED & PLACARDS REMOVED.</P>)
INERTIA REEL DEPLOYED DURING TAKEOFF ROLL.(<P>REMOVED AND REPLACED INERTIA REEL AT POSITION B IAW AMM 25-61-01.</P>).
01 EA INERTIAL ESCAPE REEL DEPLOYED IN THE COCKPIT - 06 REELS STILL AVAILABLE FOR USAGE(<P>TRANSFER TO DMI 105285 PER MEL 25-61-01-01 CAT C MBCB 10JAN19 MPCW PLACARD INSTALLED. </P><P>REMOVE AND REPLACED DESCENT DEVICE IAW AMM 25-61-00 THIS CLEARS MDDR 105285 PLACARD REMOVED.<BR DATA-MCE-BOGUS="1" /></P>).
APU FAILED TO START&NBSP;(<P>REMOVED AND REPLACED APU EXCITER IAW 49-41-03 OPS CKD OK REMOVED AND REPLACED IGNITOR IAW AMM 49-41-02 OPS GOOD</P>)
MAIN DECK SMOKE DET LOOP A INOP. PERFORMED TEST OF DETECTION SYSTEM IAW AMM 26-14-00, NO FURTHER DEFECTS NOTED.
APU WILL NOT START. PERFORMED APU BITE PROCEDURE IAW AMM 49-11-00 F/T 815, NO FAULTS AT THIS TIME. APU OPS CHECK NORMAL IAW AMM 49-11-00.
FWD EQUIP EXHAUST FAN STATUS MESSAGE. REMOVED AND REPLACED CURRENT SENSOR RELAY IAW SWPM 20-81-00. OPS CHECK GOOD IAW FIM 21-58 FT 905, NO DEFECTS NOTED AT THIS TIME.
ON BATTERY PWR STBY PWR DID NOT WORK. PERFORMED STANDBY OPERATIONAL TEST IAW AMM 24-33-00 TEST OK AT THIS TIME.
APU WILL NOT START NO LIGHT OFF&NBSP;(<P>TRANSFERRED TO MDDR # 103645 AS PER MEL 49-11-01A CAT C&NBSP;</P><P>LOG PAGE 1016942 SERVICED APU OIL WITH 01 QT I.A.W AMM 12-13-04 , APU OPERATES NORMALLY AT THIS TIME AS PER AMM 49-11-00.
FOR WXR ON TERRAIN MUST BE SELECTED ON AND OFF SEVERAL TIMES BEFORE E(<P>LOADED NEW EFIS SYMBOL GENERATOR IAW AMM 34-22-00 OPS CKS GOOD&NBSP;</P>)
WX RADAR OR TERRAIN MUST BE SELECTED ON AND OFF SEVERAL TIMES BEFORE ENGAGING&NBSP;(<P>ACCOMPLISHED OPERATION CHECK OF WXR AND TERR IAW AMM 34-43-00 AND AMM 34-46-01 OPS CHECK NORMAL&NBSP;</P>)
DESCENT DEVICE DEPLOYED ON LANDING(<P><SPAN>REMOVED / AND REPLACED DESCENT DEVICE IAW SPECIAL FREIGHTER MAINT MANUAL 25-61-03</SPAN></P>)
RH WING T/E SUPPORT BRACKET I/B OF #9 SPOILER HAS EXFOLIATING CORROSION(<P>UPON EVALUATION FOUND SUPPORT BRACKET OUT OF LIMITS DUE TO 100% MATERIAL LOSS, REPAIRED BRACKET IAW B767 SRM 51-70-12 DETAIL III</P>)
LH AC PACK GROUND AIR SUPLLY&NBSP;DUCT COUPLING LEAKING AIR(<P>REMOVED AND REPLACED PERI SEALS AT LH FD CROSSOVER DUCT AND PERFORMED GOOD LEAK TEST IAW AMM 36-11-01</P>)
RH ECS BAY AFT LWR CROSSOVER DUCT O/B OF VALVE IS LEAKING(<P>REMOVED AND REPLACED RH ECS BAY AFT LOWER CROSSOVER DUCT SEALS IAW AMM 36-11-01, NO LEAK DETECTED.</P>)
CORROSION AROUND DOUBLER AT 7 O' CLOCK POSITION IN FAN CASE ENGINE #1(<P>ACCOMPLISHED REPAIR IN ENG #1 FAN CASE AT 7 O'CLOCK POSITION IAW GE CF6-80C2 ENGINE MANUAL 72-22-01.</P><P><BR DATA-MCE-BOGUS="1" /></P>)
CORROSION AROUND DOUBLER AT 5 O'CLOCK POSITION IN FAN CASE ENG #1(<P>ACCOMPLISHED REPAIR ON ENG #1 FAN CASE AT 5 O'CLOCK POSITION IAW GE CF6-80C2 ENGINE MANUAL 72-22-01</P>)
EVIDENCE OF BIRD INGESTION ON ENG #1 INLET COWL AT 1230 POSITION (FACING ENG) AND OUTLET GUIDE VANE AT 1130 POSITION(<P>COMPLETED GVI #1 ENGINE NOSE COWL AND ENGINE INTAKE AND FOUND EVIDENCE OF BIRD STRIKE AT 1230 POSITION ON INLET COWL IAW B767 AMM 05-51-18. COMPLETED VISUAL CONDITION INSPECTION AND COMPLETED VISUAL INSPECTION ENGINE INTAKE AND EXHAUST AREAS FOUND NO DEFECTS IAW B767 AMM 72-00-00-206. NO EVIDENCE OF INGESTION TO THE CORE OF THE ENGINE NOTED.</P>)
CORROSION AROUND DOUBLER AT 6 O' CLOCK PSOTION&NBSP;IN FAN CASE #1 ENGINE(<P>ACCOMPLISHED REPEAIR&NBSP;ON ENGINE #1 FAN CASE AT 6 O' CLOCK POSITION IAW GE CF6-80C2 ENGINE MANUAL 72-22-01.</P>)
FWD CARGO COMPARTMENT CEILING HAS CLOGGED SMOKE DETECTION AT BS 502 LBL 5(<P>CLEANED AND UNBLOCKED SMOKE DETECTI TUBE IAW BOEING SOPM 20-30-03</P>)
#1 ENG COOLING DUCT HEAT SHIELD SECTION IS TORN, APPROX 3 O CLOCK POSITION JUST AFT OF THE UPPER IGNITER PLUG.(<P>REMOVED AND REPLACED HEAT SHIELD INSULATION BLANKET ON #1 ENGINE DUCT AT 3 O' CLOCK POSITION IAW GE CF680C2 ESM 72-00-0</P>)
REMOVE SURGE CONTROL VALVE AND INSTALL TROUBLESHOOTING SURGE CONTROL VALVE FOR TROUBLESHOOTING PURPOSES.(<P>REMOVED AND REPLACED APU SURGE CONTROL VALVE IAW B767 AMM 49-53-01. PERFORMED SATISFACTORY OPS AND LEAK CHECK, NO DEFECTS NOTED.</P>)
EQUIPMENT COOLING FAN SATURATED WITH OIL AND NICKS ON FAN BLADES(<P>REMOVED AND REPLACED EQUIPMENT COOLING FAN IAW AMM 2-58-06</P>)
LH WING TO BODY AREA, BLEED AIR DUCT SENSE LINE RUBBING AGAINST AROUND STUD INSIDE ACCESS PANEL #193KL(<P>REMOVED AND REPLACED BLEED AIR SENSE LINE IAW AMM 20-10-09. PERFORMED LEAK CHECK, NO LEAKS NOTED IAW B767 AMM 36-11-00.</P>)
LH AFT WTB FAIRING STRUCTURE TO FUSELAGE STRAP BS 1175 CORRODED(<P>REMOVED CORROSION AT LH AFT WTB FAIRING STRUCTURE TO FUSELAGE STRAP BS 1175 FOUND WITHIN LIMITS IAW B767 SRM 53-00-71</P>)
LH AFT WTB STRUCTURE FUSELAGE STRAP BS 1109 CORRODED.(<P>REMOVED CORROSION AT LH AFT WTB STRUCTURE FUSELAGE STRAP BS 1109 FOUND WITHIN LIMITS IAW B767 SRM 53-00-71</P>)
RT AFT WTB STRUCTURE FUSELAGE STRAP BS 1109 CORRODED 111-40(<P>REMOVED CORROSION AT RT AFT WTB STRUCTURE FUSELAGE STRAP BS 1109 FOUND WITHIN LIMITS IAW B767 SRM 53-0-71 AND SRM 51-10-02, TREATED, PRIMED, AND TOP COATED AREA IAW B767 SRM 51-20-01</P>)
CORROSION AROUND 3EA FASTENERS HOLES ON #1 ENG FAN CASE EXTERNAL SURFACE, LOCATED APPROX BETWEEN 7 AND 8 O CLOCK POSITION AND JUST BELOW THE ECU(<P>REMOVED CORROSION, EVALUATED AREA AND FOUND WITHIN LIMITS IAW GE CF6-80C2 ENGINE MANUAL 72-22-01. TREATED AND PRIMED.</P>)
LT ENG START DUCT PRESS FLUCTUATED 10-20 PSI MAX N2 OF 14, DISCONTINUED. START CROSSBLEED START ACCOMPLISHED NORMALLY. PERFORMED APU OPS TEST IAW AMM-49-11-00, NO FAULTS NOTED. OPS CHECK GOOD. UNABLE TO DUPLICATED CONDITION.
APU INOP. TRANSFER TO MDDR 101463 IAW MEL 49-11-01A CAT C DUE DATE 30-OCT-18.
LOW APU BLEED PRESSURE DURING LEFT ENGINE START DISCONTINED START AND PERFORM A X BLEED START. UNABLE TO DUPLICATE CONDITION PERFORMED APU OPS TEST IAW AMM 49-11-00 OPS CHECK OK.
FO RADAR DISPLAY TURNS OFF THE RADAR. PERFORMED WX RADAR OPERATIONAL TEST IAW AMM 34-43-00 & SYSTEM TEST IAW AMM 34-43-00. OPS CHECKED GOOD. NO DEFECTS NOTED AT THIS TIME.
FO'S WXR AND TERR SELECT SWITCHES INTERMITTENLY DONT FUNCTION WHEN NEEDED. ALIGNED IRU'S AND CYCLED THROUGH CAPT AND FO'S WX AND TERR SWITCHED SEVERAL TIMES IN BOTH TEST AND WX POSITION. OPS CHECKED OK IAW AMM 34-43-00.
F/O MFD DOES NOT DEPICT WEATHER WHEN SELECTED NOR TERRAIN WHEN SELECTED. PERFORMED OPERATION TEST ON F/O WEATHER RADAR IAW AMM 34-43-00. OPS CHECK NORMAL, NO DEFECTS AT THIS TIME.
APU INOP. PERFORMED APU RUN THREE TIMES AND PUT LOAD ON IAW AMM 49-11-01, DUCT PRESSURE 30 PSI PERFORMED BITE IAW FIM 49-11 F/T 958. NO DEFECTS NOTED AT THIS TIME.
CTR L FUEL PUMP MSG DISPLAYED AFTER ENG START, LEFT C PUMP DISPLAYED PRESSURE LIGHT. PERFORMED VOLTAGE CHECK AT LT CENTER FUEL PUMP AT PINS 2,4,6, 115VOLTS AC PERFORMED VOLTAGE CHECK AT LT FUEL OVRD PUMP CONT RELAY AT PINS A2,B,C2 115 VOLTS AC NOTED, THEN ALSO CHECKED VOLTAGE AT PINS X1 AND X2 28 VOLTS NOTED. THEN CHECKED VOLTAGE COMING OUT AT PINS A1,B1,C1 115 VOLTS AC NOTED. FOUND CONNECTOR ON LT CENTER FUEL PUMP CONTAMINATED. CLEANED CONNECTOR IAW SWPM 20-60-01 PERFORMED OPS CHECK OF LT CENTER FUEL PUMP IAW AMM 28-31-0, OPS CHECK GOOD. VOLTAGE CHECK IAW WDM 28-22-12 SHEET 1.
APU INOP. REPLACED ECU PER AMM 49-61-05 OPS CHECKS GOOD. TESTED APU, CYCLED APU BLEED VALVE 4 TIMES, OPS CHECKED GOOD.
STATUS MSG AFT EQ EXH FAN 2. COMPLIED WITH SYSTEM TEST IAW AMM 21-58-41 CHECKS GOOD, ERASED STATUS MSG PER AMM 31-41-00.
APU BLEED PRESS LOW. TROUBLE SHOOT PER FIM 49-11 FT 979, FOUND EXCESSIVE AMOUNT OF BLEED AIR LEAKING FROM SURGE VALVE. REPOSITIONED AND SECURED CLAMPS, OPS CHECK GOOD.
FUEL LEAK BY PRESSURE SWITCH LEFT FWD FUEL PUMP. REMOVED AND REPLACED LEFT PRESSURE SWITCH ON FWD FUEL PUMP IAW AMM 28-43-01.
APU OIL QTY TRANSMITTER LEAKING. REMOVED AND REPLACED OIL QTY TRANSMITTER O RING, NO LEAKS NOTED IAW AMM 49-94-04.
APU INOP. CLEANED SENSOR IAW AMM 49-53-08. PERFORMED SUPPLY PRESSURE INDICATING SYSTEM. OPERATIONAL CHECK GOOD AT THIS TIME.
STATUS MSG AFT EQ EXH FAN 2. MSG CLEARED AND AFT EQ EXH FANS TEST OK PER AMM 21-26-01.
APU AUTO SHUT DOWN. REMOVED AND REPLACED FLOW SENSING MODULE IAW AMM 49-33-03. OPS CHECK GOOD.
APU NO DUCT PRESSURE. PERFORMED BITE CHECK IAW FIM 49-11 FT 975. FAULTY PT SENSOR, REMOVED AND REPLACED FLOW SENSING MODULE IAW AMM 49-53-00. OPS CHECK GOOD, NO FAULTS NOTED.
ON DEPARTURE WX TERR WOULD NOT DISPLAY EITHER SIDE BOTH CAPT AND F/O RECYCLED AISLE STAND AND FWD PANEL SWITCHES APPROX 6 TIMES EACH ,THEN WX TERR AND TERR WAS DISPLAYED. PERFORMED WXR BITE PROCEDURES IAW FIM 34-43-FT 805. OPS CHECK NORMAL WXR SWITCH ON THE LEFT AND RIGHT EFIS CONTROL PANEL ON ON PAINTING IS DOUBLE PUSH TO SELECT.
DURING FLIGHT ENCOUNTERED ST ELMOS STATIC SPARKS ON FO WINDOW. WINDOW INSP AND OPS CK GOOD PER AMM 56-11-02.
LEFT BLEED OFF EICAS MESSAGE ON DESCENT. C/W TASK 36-10 FAULT TREE 836 BLEED AIR VALVE OFF LIGHT ILLUMINATED WITH SWITCH ON DUCT PRESSURE NORMAL. OPS CHECK GOOD.
AFTER APU START NO DUCT PRESS. CONFIRMED APU ISO VALVE OPEN AND PNEU ISO VALVE OPEN, PERFORMED BITE TEST ON APU ECU, FOUND P/T SENSOR FAULT ON LAST RUN, CLEARED. RESTART APU PNEUMATICS, OPS TEST NORMAL AS PER AMM 49-11-01.
EICAS MSG RT FWD FUEL PUMP WITH LEFT FUEL QTY INDICATING 2500 LOW ERRORS SELF CORRECTED AFTER 2 MINUTES. PERFORMED OPS CHECK OF FUEL BOOST PUMP IAW AMM 28-22-03. OPS CK NORMAL. PERFORMED BITE AND OPS CHECK OF FUEL QTY INDICATING SYSTEM NO FAULTS.
ON DEPARTURE FO WX RADAR INDICATED FAIL USING L SYSTEM, AFTER CYCLING WX SELECTOR, WX RADAR WORKED WITH NO FURTHER ISSUES. PERFORMED WXR BITE TEST IAW AMM 34-43-00.
LEFT FWD FUEL PUMP AUTO FUNCTION INOP. PERFORMED OPS CHECK FUNCTION IAW AMM 28-25-00.
STATUS MESSAGE CABIN ALT AUTO 2 AND CABIN ALT AUTO 1 AFTER LANDING. PERFORMED FIM TASK 21-31 FAULT TREE 803, NO DEFECTS. OPS CK GOOD.
APU AUTO SHUTDOWN AFTER BLOCKOUT. REMOVED AND REPLACED FLOW SENSING MODULE IAW AMM 49-53-08. PERFORMED OPS CHECK OF APU AND RAN NR 1 ENGINE IAW AMM 71-00-00. NO DEFECTS NOTED. ENGINE RUN PERFORMED.
RT FWD FUEL PUMP EICAS MESSAGE DISPLAYED FOR APPROX 60 SECONDS DURING INITIAL CLIMB. OPS CK FUEL SYSTEM IAW AMM 28-21-00. OPS GOOD.
APU AUTO SHUTDOWN AFTER BLOCK OUT. REMOVED AND REPLACED FLOW SENSING MODULE IAW AMM 49-53-08. PERFORMED OPS CHECK OF APU AND RAN NR 1 ENGINE IAW AMM 71-00-00. NO DEFECTS NOTED. ENGINE RUN PERFORMED.
RT FWD FUEL PUMP EICAS FOR SEVERAL MINUTES AFTER TAKE OFF. PERFORMED OPS CHECK ON RIGHT FWD FUEL BOOST PUMP IAW FIM 28-22 FT 820, NO FAULT FOUND AT THIS TIME.
RT FWD FUEL PUMP EICAS MSG FOR SEVERAL MINUTES AFTER TAKE OFF. PERFORMED OPS CHECK ON RIGHT FWD FUEL BOOST PUMP PER FIM 28-22, FAULT TREE 820. NO FAULTS FOUND AT THIS TIME.
ON ARRIVAL, APU BLEED AIR VALVE WOULD NOT OPEN- NO DUCT PRESSURE. RECYCLED APU SWITCHES, DUCT PRESSURE NORMAL, NO DEFECTS NOTED AT THIS TIME IAW AMM 49-11-00.
APU INOP. (DUE PNEUMATIC PRESS LOW). PERFORMED FIM 49-11 FT 979, FOUND DEBRIS IN LINE AND FILTER CLOGGED. R&R SURGE FILTER IAW AMM 49-53-06 OPS CHECK NORMAL.
APU INOP. R&R APU ECU, PERFORMED APU BITE, NO DEFECTS NOTED AT THIS TIME AS PER AMM 49-61-05.
WEATHER RADAR ON BOTH THE CAPTAIN`S, AND FIRST OFFICER`S SIDES MUST BE CYCLED ON AND OFF SEVERAL TIMES BEFORE IT TURNS ON. REMOVED AND REPLACED THE WEATHER RADAR CONTROL PANEL IAW AMM 34-43-02, OPS CHECKED GOOD.
RIGHT A/C PACK TEMP MESSAGE AT FL 390, LIGHT EXTINGUISHES WITH SWITCH IN THE STBY N POSITION. OPS CHECKED THE RT PACK TEMP IAW AMM 21-60-00, NO DEFECTS NOTED. OPS CHECKED GOOD.
APU WILL NOT START. PERFORMED TWO APU STARTS IAW AMM 49-11-00, BOTH STARTS SUCCESSFUL ,
WEATHER RADAR DOES NOT DISPLAY ON CAPTAINS MFD. PERFORMED OPERATIONAL CHECK ON WEATHER RADAR SYSTEM IAW AMM 34-43-00. OPS CHECK GOOD AT THIS TIME.
MAIN CARGO FIRE LOOP A DECTECTOR NR 4 INOPERATIVE. REPLACED THE FIRE DETECTOR IAW AMM 26-19-01. CHECKED GOOD.
MAIN DECK FIRE DETECTOR LOOP A STATION 2 IS AMBER. PERFORMED AN OPS CHECK OF THE MAIN CARGO FIRE DETECT IAW AMM 26-11-01, NO ISSUES NOTED. OPS CHECKED GOOD,
DURING A TRANSIT CHECK, FOUND THE ENG/APU, CARGO TEST FIRE SWITCH STICKING, MASTER WARNING, CAUTION LIGHTS NOT WORKING. REMOVED & REPLACED THE FIRE - OVERHEAT TEST PANEL & THE FIRST OFFICER`S MASTER CAUTION WARNING SWITCH ASSY IAW SWPM 20-84-15, AMM 31-51-00, & AMM 26-11-01. OPS CHECKED GOOD.
WEATHER RADAR DISPLAY HAS TENDENCY TO SPOKE AT ABOUT 3O DEGREES RIGHT IN BOTH LT & RT SYSTEMS. OPS CHECKED THE WEATHER RADAR DISPLAY IAW AMM 34-43-00 , UNABLE TO DUPLICATE SPOKE ISSUE , FUNCTIONAL TESTED OK.
LEFT RADAR DOES NOT PAINT WEATHER. PERFORMED AN OPS CHECK IAW AMM 34-43-00.
FIRST OFFICER`S WEATHER RADAR WOULD NOT DISPLAY ON HSI. PERFORMED AN OPS TEST OF THE WEATHER RADAR SYSTEM , OPS CHECKED GOOD IAW AMM 34-43-00.
AFT EQUIPMENT EXHAUST FAN NR 2 MESSAGE. RACKED THE NR 2 AFT EQUIPMENT EXHAUST FAN CONTROL CARD IAW FIM 21-26-808, OPS CHECKED GOOD. MESSAGE CLEARED.
FWD EQUIPMENT EXHAUST FAN NR 2 STATUS MESSAGE. R & R THE EXHAUST FAN CIRCUIT CARD IAW AMM 20-10-01, OPS CHECKED GOOD.
LEFT FWD FUEL PUMP EICAS MESSAGE. REMOVED AND REPLACED THE LT FWD PRESSURE SWITCH IAW AMM 28-42-01, LEAK AND OPS CHECKED GOOD.
EICAS RT AFT FUEL PUMP MESSAGE. REMOVED AND REPLACED RIGHT AFT BOOST PUMP ASSY IAW AMM 28-22-03. OPS CHECKED NORMAL IAW AMM 28-22-00.
AFT EQUIPTMENT COOLING FAN INOPERATIVE IN AUTO. REMOVED AND REPLACED AFT EQUIPMENT COOLING FAN IAW AMM 21-26-01. OPS CHECKED GOOD.
THREE HOURS INTO FLIGHT, WITH 30K LBS OF FUEL IN THE RIGHT TANK, RT TANK AFT RIGHT FUEL PUMP CIRCUIT BREAKER TRIPPED. IAW FIM 28-22 F/T 820, NO SIGNS OF FUEL LEAKAGE OR ANY ELECTRICAL DAMAGED NOTED. IAW FIM 28-22 F/T 820, BLOCK 5, SHEET 3. PERFORMED A BOOST PUMP OPS CHECK. OPS CHECKED GOOD.
LEFT ENGINE FATS FAILED ASM CHECK. REMOVED AND REPLACED FAN AIR TEMP SENSOR. OPS CHECK AND LEAK CHECK NORMAL IAW 36-23-00, 36-11-17.
NR 1 WINDOW F/O SIDE HAS MOISTURE AND ARCING. REMOVED AND REPLACED THE NR 1 WINDOW IAW AMM 56-11-01.
WINDOW HEAT SW FACE CRACK LEFT SIDE AND FWD. REMOVED AND REPLACED LEFT SIDE WINDOW KORRY SWITCHES IAW AMM 30-40-00.
APU BLEED, SURGE AIR DUCT TORN. REMOVED AND REPLACED APU BLEED SURGE AIR DUCT IAW AMM 20-11-00.
DESCENT DEVICE EXTENDED. REMOVED AND REPLACED DESCENT DEVICE IAW AMM 25-61-03.
DESCENT DEVICE EXTENDED. REMOVED AND REPLACED DESCENT DEVICE IAW AMM 25-61-03.
NR 2 WINDOW LT SIDE HAS SIGNS OF MOISTURE ON BUS BAR. REMOVED AND REPLACED NR 2 WINDOW LT SIDE IAW AMM 56-11-02.
AT ROTATION & DURING INITIAL CLIMB THROUGH 10.000 FT, RT FWD FUEL PUMP EICAS MESSAGE, MESSAGE EXTINGUISHED AS QRH WAS STARTED, DID NOT PRESSURE INDICATION ON PUMP, AFTER ROTATION & DURING CLIMB, FUEL CONFIGURATION MESSAGE , LEFT TANK INDICATED 3000 LBS LESS THAN RIGHT , MESSAGE EXTINGUISHED AT SAME TIME RT FWD FUEL PUMP MESSAGE DID. PERFORMED FIM TASK 28-41 FT 854, FQIS BITE TESTED GOOD. NO FAULTS NOTED, PERFORMED OPERATIONAL TEST OF FWD RIGHT BOOST PUMP IAWAMM 28-22-00, NO FAULTS NOTED, NO CIRCUIT BREAKER TRIPPED.
RT FWD FUEL PUMP EICAS MESSAGE, OPS CHECKED AW AMM 28-42-0314-039. CHECKS GOOD</P>)
ENGINE VIBRATION INDICATING SYSTEM HAS FLUCTUATIONS FOR THE RT ENGINE. REMOVED AND REPLACED THE ENGINE VIBRATION MONITOR IAW AMM 77-31-03.
RIGHT AFT FUEL PUMP EICAS MESSAGE, QRH PROCEDURE COMPLIED WITH. COMPLIED WITH FIM 28-22, FAULT TREE 819 NO DEFECTS NOTED. OK FOR SERVICE.
RIGHT BUSS TIE CIRCUIT BREAKER DAMAGED. REMOVED & REPLACED THE CIRCUIT BREAKER. REMOVED & REPLACED THE L3 TERMINAL AT C904BTB IAW SWPM 20-30-11 & WDM 24-21-51. OPS CHECKED OK IAW AMM 24-22-03.
AFTER ENGINE SHUTDOWN, THE NR 2 ENGINE WAS STILL AT MOTORING SPEED. NOTICED START VALVE WAS STILL IN GROUND. NEVER GOT ANY INDICATION BY EICAS OR VALVE LIGHT ON BY START SWITCH. REMOVED AND REPLACED THE NR 2 ENGINE START SWITCH IAW AMM 80-11-51. PERFORMED A NR 2 ENGINE START PROCEDURES IAW AMM 80-11-00. NO FAULTS NOTED.
DURING THE FIRST OFFICER`S PRE-FLIGHT, THE R2 WINDOW HEAT WAS NOT WORKING, R2 WINDOW HEAT INOPERATIVE. IAW FIM 30-41-TR 801, OPS CHECKED IAW AMM 30-41-00.
EMERGENCY EXIT SIGN AT L1 DOOR FELL DOWN OFF LINER.(<DIV>FOUND EXIT SIGN ATTACH BRACKET DISCONNECTED. RE-ATTACHED MOUNT BRACKET ON INSTALLED LIGHT ASSY AS PER AMM 33-51-01. OPS CHK OK</DIV>)
IN CRUISE RIGHT AFT FUEL PUMP EICAS MESSAGE DISPLAYED. RAN QRM AND SELECTED PUMP OFF. ALSO FOUND ITS CIRCUIT BRAKER POPPED&NBSP;(<P>RESETC/B AND RESET FUEL FLEC PANEL IAW B767 FIM 28-22-43 -828. NO DEFECTS NOTED. OPS CHECK GOOD&NBSP;</P>)
L1 DOOR EMERGENCY EXIT LIGHT ASSEMBLY DETACHED&NBSP;FROM SIDE WALL&NBSP;(<P>RE-SECURED&NBSP; LIGHT ASSY AT C1 DOOR EMERGENCY EXIT OK FOR SERVICE&NBSP;</P>)
WX RADAR FAILED IN FLIGHT&NBSP;(<P>TRANSFERRRED TO MDDR 86734 PER MEL 34-43-01-02</P><P>LOGPAGE 924927 ITEM #6: REMOVED AND REPLACED DRIVE UNIT IAW 767 AMM 34-43-05 OPS CHECKS GOOD&NBSP; THIS CLEARS MDDR86734</P>)
RIGHT ENGINE VALVE LIGHT FAILED TO ILLUMINATE WHEN RIGHT FUEL CONTROL SWITCH WAS SELECTED TO RUN. REPLACED THE RELAY K1252. OPS CHECKED GOOD.
APU INOPERATIVE. REMOVED AND REPLACED APU ECU IAW AMM 49-11-01A. OPS CHECKED GOOD.
RIGHT ENGINE FUEL VALVE LIGHT FAILED TO ILLUMINATE WHEN RIGHT FUEL CONTROL SWITCH WAS SELECTED TO RUN. RIGHT ENGINE FUEL VALVE INDICATION INOPERATIVE. REPLACED THE LAMP & INDICATING SWITCH. PERFORMED AN INDICATOR LIGHT TEST, OPS CHECKED GOOD IAW AMM 33-13-00.
FIRE DETECTION CONTROL PANEL BACKGROUND LIGHTING INOPERATIVE. REMOVED AND REPLACED FIRE OVERHEAT TEST PANEL IAW AMM 26-11-01. OPS CHECKED NORMAL.
ON DEPARTURE, RT FUEL BOOST PUMP LOW PRESSURE LIGHT ILLUMINATED. EICAS MESSAGE CAME ON. EXTINGUISH AFTER APPROX 2 MINUTES. PERFORMED EICAS BITE IAW FIM 31-41-00/101, SYSTEM OK.
WIRE W1050-99-22 BURN FROM K547, PIN 8 TO DC396J PIN 8 FOUND DURING APU INLET DOOR MOD. REPAIRED WIRE W1050-99-22 IAW SWPM 20-10-13.
FUSELAGE EMERGENCY LIGHT IS INOP. REMOVED AND REPLACED FUSELAGE EMERGENCY LIGHT IAW AMM 33-51-00.
RT PACK HAS A WATER LEAK AT THE ACM OUTLET COUPLING. REMOVED AND REPLACED SEALS AT THE ACM OUTLET COUPLING IAW AMM 21-51-03. OPS CHECK NO LEAK FOUND.
PRVC LT ENGINE INOP. REMOVED AND REPLACED LT ENGINE PRVC VALVE PER AMM 36-11-18.
DURING PREFLIGHT, FOUND A FLIGHT DECK CAUTION MESSAGE ON EICAS. REMOVED & REPLACED THE DUCT AIR TEMP SENSOR IAW AMM 21-61-02, OPS NORMAL.
CAPTAIN`S WEATHER RADAR SWITCH INTERMITTENT, TAKES MORE THAN ONE ATTEMPT TO TURN WEATHER RADAR ON. CLEANED THE WEATHER RADAR SWITCH IAW AMM 34-43-05, OPS CHECKED NORMAL.
MAINT MESSAGE AFT DETECTOR FAN. FOUND THE NR 1 AFT DETECTOR FAN INOPERATIVE. REMOVED & REPLACED THE SMOKE DETECTOR BLOWER IAW AMM 26-16-02. OPS CHECKED GOOD.
AFT CABIN TEMP MESSAGE. REMOVED AND REPLACED AFT TRIM AIR MODULATING VALVE IAW AMM 21-61-07 LEAK AND OPS CHECKED GOOD.
RIGHT ENGINE BLEED AIR OFF LIGHT INOPERATIVE. REMOVED AND REPLACED RIGHT ENGINE PRSOV IAW AMM 36-11-09, OPS AND LEAK CHECKED OK.
MAINTENANCE MESSAGE AFT DETECTOR FAN. REMOVED AND REPLACED THE NR 1 SYSTEM AFT CARGO SMOKE DETECTOR BLOWER IAW AMM 26-16-02, OPS CHECKED GOOD.
DURING DESCENT AT ABOUT 13000 FT, AN EICAS FOR THE RT PACK TEMP, FOLLOWED QRH, AND MESSAGE WENT AWAY. CONTROLLER SELECTED TO N. REMOVED AND REPLACED THE RIGHT TEMP PACK CONTROL VALVE IAW AMM 21-51-12. OP CHECKED GOOD.
FLT DECK TEMP CONTROLLER INOPERATIVE. BITE CHECKED AUTO CONTROLLER, FAILED FLT DECK TEMP SENSOR TS175, REMOVED AND REPLACED THE SENSOR IAW AMM 21-61-02, OPS CHECKED GOOD .
AFTER ENGINE START BUT BEFORE TAKEOFF, A RIGHT PACK TEMP EICAS ILLUMINATED. REMOVED AND REPLACED THE ACM IAW 21-51-03, OP CHECKED NORMAL.
RIGHT ENGINE VALVE LIGHT DID NOT ILLUMINATED UPON ENGINE START.
RT ENGINE SPAR VALVE LIGHT STUCK ON. FOUND THE RT ENGINE FUEL VALVE BREAKER OUT, RESET, AND VALVE OPERATION NORMAL IAW AMM 28-22-11.
RIGHT PACK TEMPERATURE EICAS MESSAGE WITH ASSOCIATED INOP LIGHT. PERFORMED PACK TEMP QRH PROCEDURE SELECTED STANDBY NORMAL. DEFERING RT PACK IAW DDG 21-51-01-01 MDDR 81837 PLACARD INSTALLED. REPLACED MIX MANIFOLD SENSOR OPS CKS GOOD IAW AMM 21-61-02. CLEARED MDDR.
HI FLOW INHIBIT STATUS MESSAGE. COMPLIED WITH FIM 21-51 FT 813, NO FAULTS ON PREVIOUS FLIGHT IAW FLIGHT CREW,
LEFT ENGINE SPEED CARD FAULTED. REMOVED AND REPLACED THE SPEED CARD IAW AMM 73-21-54. OPS CHECKED GOOD.
WEATHER RADAR TILT SEEMS OFF, HAD TO TILT OVER 5 DEGREES DOWN JUST TO GET GROUND. PERFORMED AN OPS CHECK, NO DEFECTS NOTED AT THIS TIME IAW AMM 34-43-00.
AT 11,000 FT ,A3.0 PSI MAIN CARGO DOOR LIGHT & C/W QRH 1.17 AT 1,500 ON LANDING 0.4 PSI.
DENT FOUND ON NR 2 ENGINE. INLET COWL INNER SKIN AT THE 5 O'CLOCK POSITION. ACCOMPLISHED PART ONE, IAW EO 1971A149. REMOVED AND REPLACED THE NR 2 ENGINE INLET COWL IAW AMM 71-11-01.
R2 WINDOW HEAT SIDE SWITCH LIGHT INOPERATIVE IN THE ON POSITION.
AFT EQUIPMENT EXHAUST FAN NR 2 STATUS MESSAGE. TROUBLESHOT IAW FIM 21-26, FAULT TREE 808. MESSAGE CLEARED, OPS CHECKED OK.
AFTER TAKE OFF, PASSING 4000 FT, MAIN CARGO DOOR WARNING LIGHT ILLUMINATED. VERIFIED THE CARGO DOOR WAS CLOSED AND LOCKED IAW AMM.
APU WILL NOT START AFTER FLIGHT. REMOVED AND REPLACED THE APU STARTER IAW AMM 49-00-00.
FUSELAGE SKIN DAMAGED BOTTOM SIDE BS 137 AND RBL 10.5. ACCOMPLISHED A REPAIR IAW EO 6753A513, REV O, PART 1. NO CRACK INDICATIONS NOTED AT THIS TIME IAW NDT M PART 6-51-00-01.
AFTER TAKE OFF, RECEIVED SIMUTIANOUS LT ENG OVERHEAT AND ENGINE FIRE, BOTH ON EICAS WITH MASTER WARNING AND AURAL WARNING. PERFORMED INSPECTION OF THE NR 1 ENGINE IAW MM 72-00-00. FOUND PLUG ON TCC VALVE LOOSE AND LEAKING OUT ONTO FIRE LOOP. SECURED THE LEAK AND CHECKED TCC VALVE, NO LEAKS NOTED IAW AMM 71-00-00. REPLACED THE LT OVERHEAT DETECTION WIRES IAW WD 26-11-12, & SWPM 20-10-11. PERFORMED LT ENGINE FIRE DETECTION OVERHEAT SYS TEST, TESTED OK IAW AMM 26-11-00.
MAIN CARGO DOOR MESSAGE CLIMBING THROUGH 14000'FT, ATB.
AFTER 30 MINUTES OF FLIGHT, THE RT FWD FUEL PRESSURE MESSAGE ILLUMINATED AND THE PRESSURE LIGHT IN BOTTON. TEST FLIGHT. PERFORMED TROUBLESHOOTING IAW FIM 28-22, FT819 FOUND K107 , AND THE RT FWD RELAY OPEN AND PERFORMED A RESET. PERFORMED FIM FIG 119 FT 831 SHEET 3 P-AGE 174 AND THE FAULT WAS NO PRESSENT.
COCKPIT TRIM VALVE INDICATION, BOTH DIGITAL IN ECS MAINTENANCES PAGE & MANUAL ON OVERHEAD PANEL. WHEN EVER IT CASSES THE 70 TOOLEDDS THE FULL CLOSE POS . IN START TO FLUCTUTE FROM CLOSE TO 0.70 WORKS OK. TEST FLIGHT(<DIV>COCKPIT TRIM AIR &NBSP;VALVE REPLACED &NBSP;IAW AMM 21-61-07 CHECKED &NBSP;FOR OPERATION FOUND OK</DIV>)
ENGINE FUEL SHUTOFF VALVE ACTUATOR AT LT WING TANK, BONDING HIGH RESISTANCE. THE BONDING WAS REMOVED CLEANED REINSTALLED CHECKED AND FOUND OK IAW MM 20-41-00
APU DRAIN MAST TUBE CORRODED. THE DRAIN MAST TUBE WAS REPLACED IAW MM 49-16-00.
APU ISOLATOR VIBRATION BOLTS CORRODED. VIBRATION BOLTS REPLACED IAW MM 49-11-01.
APU LT AIR SURGE BLEED DUCT CLAMPS ARE CORRODED. APU SURGE BLEED DUCT CLAMP REPLACED IAW MM 49-53-01.
NR 2 ENGINE, FAN COWL INNER SIDE IS DELAMINATED. REPLACED IAW MM 71-11-04.
NR 2 ENGINE, LT FAN COWL AFT OPEN ROD SUPPORT CHAFED. THE SUPPORT WAS REPLACED IAW MM 71-11-11-201.
NR 1 ENGINE, INLET COWL AFT BULKHEAD WEARSTRIP BROKEN AT 6 O'CLOCK , AND 9 O'CLOCK POSITIONS. THE WEARSTRIP WAS REPLACED IAW MM 71-11-04.
NR 2 ENGINE, FAN COWL LATCHES CORRODED. THE LATCHES WERE CLEANED IAW MM 20-30-03.
NR 2 ENGINE, RT FAN COWL HAS A TORN SEAL. THE FAN COWL ASSY WAS REPLACED IAW MM 71-11-04.
NR 2 ENGINE RT FAN COWL HAD A TORN SEAL. THE SEAL REPLACED IAW MM 71-11-04.
NR 2 ENGINE INLET COWL AFT BULKHEAD RUBSTRIP HAS RIVETS MISSING AT 6 O'CLOCK POSITION. REPLACED THE RIVETS IAW MM 71-11-04.
NR 1 ENGINE PRSOV FAILED TEST. THE PRSOV WAS REPLACED IAW MM 36-11-09.
NR 2 ENGINE EICAS MESSAGE FOR THE NR 2 FIRE LOOP. THE FIRE LOOP WAS REPLACED IAW MM 26-11-01.
LEFT PACK FLEXIBLE TIE RESTRAINT IS DAMAGED. LT PACK RESTRAINT TIE REPLACED IAW MM 21-51-00.
NR 1 ENGINE, LT CORE COWL HOLD OPEN BRACKET WORN. BRACKET FASTENERS REPLACED IAW MM 26-23-02.
NR 2 ENGINE, RT CORE COWL SCRATCHED IN THE MIDDLE. SCRATCH SMOOTHED IAW SRM 51-10-02, NDT CHECKED IAW D634T301, PART 6 51-00-19, NO CRACKS FOUND. THICKNESS MEASURED IAW D 634T301, PART 4 51-00-10, & FOUND WITH IN LIMITS IAW SRM 54-42-01.
FUSELAGE KEEL BEAM LBL 9.50 AND RBL 9.50, FROM BS 676 TO 1307 AT ANCHOR NUTS ARE CORRODED.
NR 2 ENGINE, LT CORE COWL SUPPORT BOLT HAVE PLAY. THE BRACKET BUSHING & BOLTS REPLACED IAW AMM 71-11-11.
LEFT AND RIGHT PACKS, FOUR PACKINGS ARE TORN THE PACKINGS WERE REPLACED IAW MM 21-51-08.
NR 1 ENGINE FAN COWLS HAVE DENTS IN SOME PLACES. THE DENTS WERE FILLED WITH COMPOUND IAW MM 54-21-01 & REPAINTED IAW MM 51-21-10.
NR 2 ENGINE FAN COWLS HAVE DENTS IN SOME PLACES. DENTS FILLED WITH COMPOUND IAW MM 54-21-01 & REPAINTED IAW MM 51-21-10.
NR 2 ENGINE CORE COWLS SCRATCHED IN SOME PLACES. SCRATCHES SMOOTHED IAW MM 51-10-02, NDT CHECKED IAW D634T301, PART 651-00-10, FOUND WITHIN LIMITS PER SRM 54-42-01.</P>)
OVERRIDE, JETTISON PUMPS AT RT WING TANK HAS RESISTANCE AT BONDINGS. THE BONDING WAS CLEANED AND REINSTALLED. CHECKED FOR OPERATION AND FOUND OK IAW MM 20-41-00.
AIR CONDITIONING PANEL DISPLAY NOT READING. TEMP COMPARTMENT INDICATOR WAS REPLACED IAW MM 21-65-01-401-014.
LEFT IDG DISCONNECT SWITCH GUARD BROKEN. THE SWITCH GUARD WAS REPLACED IAW SWPM 20-84-00.
NR 2 ENGINE HPT COOLING TUBE AT 3 O'CLOCK POSITION ATTACHING BRACKET IS CRACKED. REPLACED THE BRACKET.
NR 2 ENGINE, CORE COWL AFTER LOWER TRIANGULAR BRACKET HAD FASTENERS LOOSE OR MISSING. BRACKET FASTENERS REPLACED IAW SRM 51-40-02.
AFT CARGO NR 6R PDU IS INOPERATIVE. THE PDU REPLACED IAW MM 25-53-01 CHECKED FOR OPERATION AND FOUND OK.
FWD CARGO, LEFT SIDE EQUIPMENT COOLING TUBE DENTED. THE COOLING TUBE WAS REPLACED IAW MM 21-58-00.
FWD CARGO AT MIX BAY, FOUR COUPLING TUBES DAMAGED. THE COUPLING TUBES WERE REPLACED IAW MM 21-21-52.
FWD AND AFT ENGINE FUEL CROSSFEED HINGE BONDING RESISTANCE. FUEL CROSSFEED BONDING CLEANED, REINSTALLED CHECKED FOR OPERATION & FOUND OK PER MM 20-41-00</P>)
FWD CARGO BAY EQUIPMENT COOLING SYSTEM, 5 GASKETS ARE MISSING. NEW GASKETS INSTALLED IAW MM 21-58-00.
NR 2 AND 1 ENGINES FAN COWLS SLING BOLTS MISSING. FAN COWLS MISSING SLING BOLTS REPLACED IAW MM 20-11-00.
RT AND LT BOOST PUMP SLEEVES ARE CORRODED. SLEEVES REPLACED IAW MM 28-22-05.
OVERRIDE, JETTISON PUMP AT LT WING HIGH BONDING RESISTANCE. BONDING CLEANED &TREATED, CHECKED AND FOUND OK IAW MM 20-41-00.