N12061

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

32 reports on file, 1995-04-24 – 2001-10-10.

ELECT. POWER LOSS-50 PC · 2001-10-10 Unresolved
ATA 2460

Part: RCCB — FAILED (ELECTRICAL SYS)

LAX - FLT 32 - AIR DIVERSION AT 3 HOURS INTO FLIGHT, LT EMERGENCY AC BUS OFF LIGHT ILLUMINATED, RESTORED SYSTEM. FOLLOWED CHECKLIST, 5 MINUTES LATER PROBLEM REOCCURRED. NR 1 GALLEY POWER OFF LIGHT ILLUMINATED. COULD NOT RESTORE POWER BY RESETTING, REMAINED OFF FOR ENTIRE FLIGHT. REPLACED RCCB B1-136. RAN ENGINE GEN AND APU AND EXIT POWER ALL OPERATION AND INDICATION NORMAL. (M)

Source: SDR HALA0100248
OTHER · 2001-05-17 Matched by certificate designator
ATA 5320

Part: FLOOR SUPPORT — CRACKED (FUSELAGE) · airframe 91,033 hrs · 15,193 cycles

INSPECTION FOUND A 6 INCH CRACK IN CENTER CARGO FLOOR SUPPORT FLANGE AT STA 1601, X = 18R. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 53-30-1 AND GMM 10-900-01.

Source: SDR CALA0100470
OTHER · 2001-05-17 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (FUSLEAGE) · airframe 91,033 hrs · 15,193 cycles

INSPECTION FOUND SEAT TRACK CORRODED AT STA Y = 2000-2007, X = 90L. THE SEAT TRACK WAS REPAIRED IAW SRM 53-70-00, FIGURE 5 AND ECRA 5100-01844.

Source: SDR CALA0100469
OTHER · 2001-05-16 Matched by certificate designator
ATA 5310

Part: SHEAR TIE — CORRODED (FUSELAGE) · airframe 91,033 hrs · 15,193 cycles

INSPECTION FOUND SHEAR CLEAT IN CENTER CARGO BILGE CORRODED AT STA 1801 BETWEEN LONGERON 49L AND 49R. THE SHEAR CLEAT WAS REMOVED AND A NEW SHEAR CLEAT WAS INSTALLED IAW SRM 51-30-01 AND GMM 10-900-01.

Source: SDR CALA0100465
OTHER · 2001-05-16 Matched by certificate designator
ATA 5320

Part: FLOOR SUPPORT — CORRODED (FUSELAGE) · airframe 91,033 hrs · 15,193 cycles

INSPECTION FOUND J-SECTION FLOOR SUPPORT CORRODED AT STA Y = 824, X = 50 TO 74. THE FLOOR SUPPORT WAS REPLACED IAW SRM 53-14-01 AND GMM 10-900-01.

Source: SDR CALA0100462
OTHER · 2001-05-16 Matched by certificate designator
ATA 5310

Part: SHEAR TIE — CORRODED (FUSELAGE) · airframe 91,033 hrs · 15,193 cycles

INSPECTION FOUND SHEAR CLEAT CORRODED AT STA 1841 BETWEEN LONGERON 48R AND 47R. THE SHEAR CLEAT WAS REMOVED AND A NEW SHEAR CLEAT WAS INSTALLED IAW SRM 51-30-01 AND GMM 10-900-01.

Source: SDR CALA0100464
OTHER · 2001-05-16 Matched by certificate designator
ATA 5310

Part: SHEAR TIE — CORRODED (FUSELAGE) · airframe 91,033 hrs · 15,193 cycles

INSPECTION FOUND SHEAR CLEAT CORRODED AT STA 1902 BETWEEN LONGERONS 51R AND 50R AND BETWEEN LONGERONS 48L AND 47L. THE SHEAR CLEATS WERE REMOVED AND NEW SHEAR CLEATS WERE INSTALLED IAW SRM 51-30-01 AND GMM 10-900-01.

Source: SDR CALA0100463
OTHER · 2001-05-16 Matched by certificate designator
ATA 5730

Part: SKIN — CRACKED (RT WING) · airframe 91,033 hrs · 15,193 cycles

INSPECTION FOUND A CRACK IN RT WING LEADING EDGE SKIN AT SLAT NR 7 I/B TRACK, XORS 79.9. REPAIRED IAW SRM 57-10-00.

Source: SDR CALA0100466
OTHER · 2001-05-13 Matched by certificate designator
ATA 5320

Part: FLOOR SUPPORT — CORRODED (FUSELAGE) · airframe 91,033 hrs · 15,193 cycles

INSPECTION FOUND LAV J O/B FLOOR SUPPORT BEAM CORRODED IN AREAS OF TIE DOWN BOLTS AT STAY = 1887-2007 AT X = 58R. THE FLOOR SUPPORT BEAM WAS REMOVED AND A NEW FLOOR SUPPORT BEAM WAS INSTALLED IAW SRM 53-16-01.

Source: SDR CALA0100456
OTHER · 2001-05-08 Matched by certificate designator
ATA 5320

Part: BEAM — CORRODED (FUSELAGE) · airframe 91,033 hrs · 15,193 cycles

INSPECTION FOUND REAR PRESSURE BULKHEAD T-SECTION LATERAL BEAM CORRODED AT ATTACHMENT POINTS AT STA Y = 2007 AND X = 58R, 58L, 27R, AND 27L. A NEW BEAM WAS INSTALLED IAW ECRA 5100-01844 AND SRM 53-16-01.

Source: SDR CALA0100450
Earlier reports · 1995–2000 · 22 reports

2000

WARNING INDICATION · 2000-07-22 Unresolved
ATA 2450

Part: FUSE — FAILED (BUSS CONTROL)

FLT 006 - OGG - AFTER ENGINE START AC BUS TIE WAS NOT POWERED BY ANY GENERATOR. PERFORMED AC BUS TIE. ISOL LIGHTS ILLUMINATED. NO CHANGE. TROUBLESHOT AND FOUND BCU INPUT FUSE LIGHT ON. REPLACED FUSE. RAN ALL 3 ENGINES. AC BUS TIE ISOLATION OFF. BUSSES OK. (M)

Source: SDR HALA0000237
WARNING INDICATION · 2000-07-22 Unresolved
ATA 2913

Part: PUMP — FAILED (HYD SYSTEM)

FLT 006 - OGG - NR 2 ENGINE DRIVEN HYDRAULIC PUMP WOULD NOT DEPRESSURIZE WITH SWITCH IN OFF POSITION. REMOVED AND REPLACED NR 2 ENGINE DRIVEN HYD PUMP, LEFT PUMP. OPERATIONAL AND LEAK CHECK GOOD. ALL HYDRAULIC QUANTITIES ARE AT NORMAL FULL LEVEL. WORK DONE IAW 29-11-01 PAGE 201. (M)

Source: SDR HALA0000236
OTHER · 2000-04-04 Matched by certificate designator
ATA 5720

Part: HINGE — CRACKED (RT WING) · airframe 88,250 hrs · 14,553 cycles

INSPECTION FOUND A 0.2 INCH CRACK IN RT WING TRAILING EDGE HINGE AT STA XORS 714. THE HINGE WAS REPLACED IAW SRM 57-31-01.

Source: SDR CALA0000395

1999

NO TEST · 1999-06-10 Matched by certificate designator
ATA 3350

Part: FUSE — BLOWN (ROW 35-45)

THE EMERGENCY LIGHTS WERE FOUND INOPERATIVE FROM ROWS 35-45 A/B. MAINTENANCE FOUND A FUSE BLOWN FOR THAT SECTION. THE FUSE WAS REPLACED. OPERATION OF THE LIGHTS CHECKED GOOD.

Source: SDR CALA9900664
OTHER · 1999-03-27 Matched by certificate designator
ATA 5751

Part: SKIN — CORRODED (RIGHT AILERON)

INSPECTION FOUND RT WING O/B AILERON LOWER SKIN CORRODED. THE AILERON WAS REMOVED AND REPLACED IAW MM 27-10-02.

Source: SDR CALA9900333
OTHER · 1999-03-26 Matched by certificate designator
ATA 5414

Part: PANEL — CRACKED (NR 3 PYLON)

INSPECTION FOUND A 3 INCH CRACK ON NR 3 PYLON PANEL NR 487ER. THE PANEL WAS REPLACED IAW SRM 51-30-00.

Source: SDR CALA9900331
OTHER · 1999-03-26 Matched by certificate designator
ATA 5730

Part: PANEL — CRACKED (RIGHT WING)

INSPECTION FOUND A 3 INCH CRACK IN RT WING LEADING EDGE ACCESS PANEL NR 617CT. THE PANEL WAS REPLACED IAW SRM 51-31-01.

Source: SDR CALA9900330
NO TEST · 1999-03-25 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (ROW 1-4)

INSPECTION FOUND FLASHLIGHTS INOPERATIVE AT FLIGHT ATTENDANT SEATS 1L-4L AFT. THE FLASHLIGHT BATTERIES WERE REPLACED IAW MM 25-60-00.

Source: SDR CALA9900324
OTHER · 1999-03-25 Matched by certificate designator
ATA 5414

Part: SKIN — CRACKED (NR 3 PYLON)

INSPECTION FOUND A 1 CRACK IN NR 3 PYLON SKIN. A DOUBLER REPAIR WAS INSTALLED IAW ECRA 5450-01212. A DIP WAS ISSUED TO CHECK BLIND FASTENERS FOR SECURITY EVERY 1000 CYCLES UNTIL A PERMANENT REPAIR IS INSTALLED WITHIN 400 DAYS.

Source: SDR CALA9900325
OTHER · 1999-03-24 Matched by certificate designator
ATA 7110

Part: INLET — CRACKED (NR 3 ENGINE)

INSPECTION FOUND TWO INCH CRACKS IN THE NR 3 ENGINE FAN INLET. REPAIRED IAW SRM 54-11-00, PAGE 23.

Source: SDR CALA9900320
OTHER · 1999-03-24 Matched by certificate designator
ATA 5753

Part: SKIN — CRACKED (RT TE FLAP)

INSPECTION FOUND A 1 CRACK IN RT WING OUTBOARD FLAP SKIN. THE SKIN WAS REPLACED IAW DOUGLAS DRAWING ARC1653.

Source: SDR CALA9900321
OTHER · 1999-03-24 Matched by certificate designator
ATA 5245

Part: SKIN — CRACKED (NR 3 PACK DOOR)

INSPECTION FOUND A 1.5 CRACK IN SKIN OF PACK DOOR NR 3. THE AREA WAS REPAIRED IAW SRM 53-50-00, FIGURE 3.

Source: SDR CALA9900319
OTHER · 1999-03-20 Matched by certificate designator
ATA 5280

Part: SKIN — CRACKED (LT MLG DOOR)

INSPECTION FOUND A .75 INCH CRACK IN LT MLG DOOR SKIN. REPAIRED IAW SRM 53-00-01.

Source: SDR CALA9900302
OTHER · 1999-03-10 Matched by certificate designator
ATA 5730

Part: SKIN — CRACKED (WING)

INSPECTION FOUND A .25 INCH CRACK NEAR WING SKIN PANEL 515AB HOLE. A REPAIR WAS PERFORMED IAW SRM 57-00-01, FIGURE 4.

Source: SDR CALA9900242

1998

WARNING INDICATION · 1998-09-20 Matched by certificate designator
ATA 3230

Part: FUSE — REQD BLEEDING (RT MLG TRIM CYL)

THE LANDING GEAR HANDLE WOULD NOT MOVE TO UP POSITION AFTER TAKEOFF. THE APPROPRIATE CHECKLIST WAS COMPLETED WITH NO HELP. THE AIRCRAFT WAS RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE TRIM CYLINDER INTERLOCK FUSE IN THE RT WHEEL WELL AT FAULT. THE TRIM CYLINDER INTERLOCK FUSE WAS BLED IAW MM 32-31-06, PAGE 203 TO 204. THE GEAR HANDLE WAS CYCLED SEVERAL TIMES AND OPERATION CHECKED GOOD.

Source: SDR CALA9801806
OTHER · 1998-02-16 Matched by certificate designator
ATA 5320

Part: JAMB — CRACKED (AC DOORWAY)

INSPECTION FOUND TWO, 2 INCH CRACKS AT UPPER SIDE OF FORWARD VERTICAL DOOR JAMB OF LT FORWARD AIR CONDITIONING COMPARTMENT. ONE AREA WAS TRIMMED AND BLENDED OUT. THE OTHER AREA WAS REWORKED AND REINFORCED WITH A DOUBLER IAW SRM 53-30-00, FIGURE 4. NEW RIVETS WERE INSTALLED IAW SRM 51-31-01.

Source: SDR CALA9800267

1996

FALSE WARNING · 1996-10-25 Matched by certificate designator
ATA 3260

Part: CONNECTOR — PULLED WIRE (RT MLG)

THE RT MLG RED UNSAFE LIGHT ILLUMINATED DURING APPROACH FOR LANDING AT LGW. THE APPROACH WAS ABORTED AND ALTERNATE GEAR EXTENSION WAS USED. GEAR DOWN INDICATIONS WERE NORMAL AND THE AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE RT MLG PROXIMITY DOWNLOCK SENSOR WIRING PULLED FROM R5-261 CONNECTOR. THE CONNECTOR WAS REPLACED AND CONDUIT WAS REROUTED, GROUND OPERATIONAL CHECKS WERE GOOD.

Source: SDR CALA9601511
FLUID LOSS; WARNING INDICATION · 1996-09-18 Matched by certificate designator
ATA 2910

Part: HYD LINE — LEAKING (NR 1 ENGINE)

THE AIRCRAFT LOST THE NR 1 HYDRAULIC SYSTEM WHILE IN FLIGHT. THE AIRCRAFT WAS RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE NR 1 ENGINE LT HYDRAULIC PUMP SUPPLY LINE LEAKING. THE HYDRAULIC SUPPLY LINE WAS REMOVED AND REPLACED. THE HYDRAULIC SYSTEM WAS SERVICED, THE ENGINE WAS RUN AND NO LEAKS WERE DETECTED.

Source: SDR CALA9601319

1995

FLUID LOSS; WARNING INDICATION · 1995-06-18 Matched by certificate designator
ATA 2910

Part: HYD LINE — LEAKING (NR 1 HYD SYS)

EWR - FLT 0010 - THE NR 1 HYDRAULIC SYSTEM QUANTITY WAS LOST WHILE ENROUTE FROM IAH TO ORY. THE AIRCRAFT WAS DIVERTED TO EWR WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE HYDRAULIC PRESSURE LINE FROM THE LEFT ENGINE DRIVEN PUMP TO THE PRESSURE MODULE LEAKING. THE HYDRAULIC PRESSURE LINE WAS REMOVED AND REPLACED. IN ADDITION, BOTH THE LT AND RT ENGINE DRIVEN HYDRAULIC PUMPS WERE REMOVED AND REPLACED AS A PRECAUTIONARY MEASURE. THE HYDRAULIC SYSTEM WAS SERVICED. THE ENGINES WERE RUN AND LEAK AND OPERATIONAL CHECKS WERE GOOD. (X)

Source: SDR CAL950500
WARNING INDICATION · 1995-05-19 Matched by certificate designator
ATA 2497

Part: HARNESS — BURNED (FWD CARGO COMPT)

FLT 57 - LGW - SEVERAL C/B'S POPPED AND BOTH THE NR 1 AND NR 2 GEN'S HAD NO VOLTS AND NO FREQUENCY WHILE EN ROUTE FROM ORY TO EWR. THE CREW WAS UNABLE TO RESTORE EITHER GEN AND THE A/C WAS DIVERTED TO LGW WHERE IT LANDED W/O INCIDENT. ALL TRIPPED C/B'S WERE ASSOCIATED WITH AC BUS NR 1 AND NR 2 AND WOULD NOT RESET. MX FOUND ALL PIN OUT WIRES SHORTED TO GROUND. THE SHORT WAS TRACED TO A BURNT OUT WIRE BUNDLE IN THE FWD CARGO CEILING AREA. THE WIRING WAS REPAIRED IAW STANDARD PRACTICES CHAP 20 OF MM. OPS CHECK OF THE NR 1 AND NR 2 GEN'S AND ALL ASSOCIATED SYSTEMS WAS GOOD. S/D - MX ALSO FOUND A STICKY LIQUID SUBSTANCE ON C/B'S OF LWR MID PNL. THE C/B'S WERE FREED, AND ANY BROKEN IN PROCESS WERE REPLACED.(M)

Source: SDR CAL950406
FALSE WARNING · 1995-04-24 Matched by certificate designator
ATA 2612

Part: FIRE LOOP — DAMAGED (FWD PYLON)

EWR - FLT 56 - AFTER TAKEOFF. NR 3 ENGINE 'A' FIRE LIGHT AND BELL CAME ON. DUMPED FUEL AND RETURNED TO EWR. FOUND FWD PYLON DETECTION ASSY DAMAGED. REF MM 26-15-01 ITEM 117, REPLACED PART AUL7122-1 OPS. CHECK SYSTEM, ALL NORMAL. (Z)

Source: SDR CAL950343
FALSE WARNING · 1995-04-24 Matched by certificate designator
ATA 2612

Part: LOOP — DAMAGED (FWD HALF)

FLT NR 56 - EWR - ON TAKEOFF WARNING BELL CAME ON AIRCRAFT RETURNED TO EWR 'NO EMERGENCY DECLARED'. MAINTENANCE FOUND DAMAGE TO FIRE LOOP FWD HALF. REPAIRED AND REPLACED DAMAGED AREA AND PARTS. OPS CHECKED, SYSTEMS ALL NORMAL. AIRCRAFT DEPARTED NO FURTHER OCCURANCE. (W)

Source: SDR CAL950319