N124LS

HONDA AIRCRAFT CO LLC HA-420 · 2023 · Fixed-wing multi-engine · 2 engines · 8 seats · Valid Registration

Registered owner: CHRISTIAN FELLOWSHIP CHURCH INC, AZ (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

5 reports on file, 2007-11-29 – 2013-05-15.

FLUID LOSS · 2013-05-15 Matched by certificate designator
ATA 2810

Part: FLAPPER VALVE — DETACHED (RT WING FUEL) · airframe 2,703 hrs · 1,531 cycles

TOWER INFORMED CREW THAT THEY WERE LOSING FUEL AFTER TAKEOFF. CREW CONFIRMED FUEL COMING OUT OF THE RT WING VENT. FUEL STOPPED FLOWING FROM VENT AFTER FIVE MINUTES. ACFT PERFORMED UNSCHEDULED LANDING SAFELY. MX EVALUATION REVEALED A DETACHED FLAPPER VALVE, R & R. LEAK CHECKED OK. NO OTHER DEFECTS FOUND.

Source: SDR CWQA20130517
WARNING INDICATION · 2007-12-10 Unresolved
ATA 2130

Part: ACTUATOR — SHORTED (RAM AIR) · airframe 628 hrs · 387 cycles

WHILE IN FLIGHT THE AIRCRAFT EXPERIENCED AND NR1 PAC OVLD INDICATION WITH SUBSEQUENT NR1 PAC AUTO SHUTDOWN AS A RESULT THE FLIGHT CREW MADE AN IN-FLIGHT DIVERSION AND UNSCHEDULED LANDING. PERFORMED DOWNLOAD OF THE CENTRAL MAINTENANCE COMPUTER WHICH REVEALED 1 OCCURRENCE OF NR1 PAC OVERTEMP AND 63 OCCURRENCES OF NR2 PAC OVERTEMP. TROUBLESHOOTING REVEALED THAT THE LT AND RT PAC OVERTEMP SWITCHES FAILED BENCH CHECK. BOTH SWITCHES WERE REPLACED WITH NEW SWITCHES. DURING THE PERFORMANCE OF THE PAC SYSTEM OPERATIONAL TEST IT WAS DISCOVERED THAT THE RT RAM AIR ACTUATOR HAD AN ELECTRICAL SHORT CAUSING THE CIRCUIT BREAKER TO (POP). REPLACED THE RT RAM AIR ACTUATOR AND PERFORMED PAC SYSTEM OPERATIONAL TESTS. DURING THE ABOVE CENTRAL MAINTENANCE COMPUTER DOWNLOAD, 17 OCCURRENCES OF A NR1 PRECOOLER TEMP CONTROL SYSTEM FAIL MESSAGE WAS NOTED. ACCESSED FAN AIR TEMPERATURE THERMOSTATS FOR TROUBLESHOOTING AND UPON REMOVAL IT WAS NOTED THAT THE AMBIENT AIR TEMPERATURE PORTS ON EACH THERMOSTAT HAD SHIPPING PLUGS IN THEM. REMOVED THE SHIPPING PLUGS AND SWAPPED THERMOSTATS FOR TROUBLESHOOTING. PERFORMED CENTRAL MAINTENANCE COMPUTER DOWNLOAD AFTER THERMOSTAT INSTALLATION WITH NO FAIL MESSAGES NOTED.

Source: SDR FAA2007121001
WARNING INDICATION · 2007-12-10 Matched by certificate designator
ATA 2130

Part: ACTUATOR — FAILED (RAM AIR) · airframe 628 hrs · 387 cycles

DURING FLIGHT, AIRCRAFT EXPERIENCED AND NR 1 PACK OVLD INDICATION WITH SUBSEQUENT NR 1 PACK AUTO SHUTDOWN AS A RESULT MADE AN IN-FLIGHT DIVERSION AND UNSCHEDULED LANDING. PERFORMED DOWNLOAD OF THE CENTRAL MAINTENANCE COMPUTER WHICH REVEALED 1 OCCURRENCE OF NR 1 PACK OVERTEMP AND 63 OCCURRENCES OF NR 2 PACK OVERTEMP. TROUBLESHOOTING REVEALED THE LT AND RT PACK OVERTEMP SWITCHES FAILED BENCH CHECK. BOTH SWITCHES WERE REPLACED. DURING PERFORMANCE OF PACK SYSTEM OPS TEST, IT WAS DISCOVERED THAT THE RT RAM AIR ACTUATOR HAD AN ELECTRICAL SHORT CAUSING THE CIRCUIT BREAKER TO TRIP. REPLACED THE RT RAM AIR ACTUATOR AND PERFORMED PAC SYSTEM OPS TESTS. DURING THE ABOVE CENTRAL MAINTENANCE COMPUTER DOWNLOAD, 17 OCCURRENCES OF A NR 1 PRECOOLER TEMP CONTROL SYSTEM FAIL MESSAGE WAS NOTED. ACCESSED FAN AIR TEMPERATURE THERMOSTATS FOR TROUBLESHOOTING AND UPON REMOVAL IT WAS NOTED THAT THE AMBIENT AIR TEMPERATURE PORTS ON EACH THERMOSTAT HAD SHIPPING PLUGS IN THEM. REMOVED THE SHIPPING CONNECTORS AND SWAPPED THERMOSTATS FOR TROUBLESHOOTING. PERFORMED CENTRAL MAINTENANCE COMPUTER DOWNLOAD AFTER THERMOSTAT INSTALLATION WITH NO FAIL MESSAGES NOTED.

Source: SDR GW4R200700001
WARNING INDICATION · 2007-11-29 Unresolved
ATA 2130

Part: ACTUATOR — SHORTED (RT RAM AIR) · airframe 628 hrs · 387 cycles

WHILE IN FLIGHT THE AC EXPERIENCED AND NR1 PAC OVLD INDICATION WITH SUBSEQUENT NR1 PAC AUTO SHUTDOWN AS A RESULT THE FLIGHT CREW MADE AN IN-FLIGHT DIVERSION AND UNSCHEDULED LANDING. DOWNLOAD OF THE COMPUTER REVEALED 1 OCCUR OF NR1 PAC OVERTEMP AND 63 OF NR2 PAC OVERTEMP. LT AND RT PAC OVERTEMP SWITCHES FAILED BENCH CHECK. BOTH SWITCHES WERE REPLACED. DURING THE PAC SYSTEM OPS TEST, THE RT RAM AIR ACTUATOR HAD AN ELECTRICAL SHORT CAUSING THE CIRCUIT BREAKER TO POP. REPLACED THE RT RAM AIR ACTUATOR AND PERFORMED PAC SYSTEM OPERATIONAL TESTS. DURING THE COMPUTER DOWNLOAD, 17 OCCURRENCES OF A NR1 PRECOOLER TEMP CONTROL SYSTEM FAIL MESSAGE WAS NOTED. ACCESSED FAN AIR TEMPERATURE THERMOSTATS FOR TROUBLESHOOTING AND UPON REMOVAL IT WAS NOTED THAT THE AMBIENT AIR TEMPERATURE PORTS ON EACH THERMOSTAT HAD SHIPPING PLUGS IN THEM. REMOVED THE SHIPPING PLUGS AND SWAPPED THERMOSTATS FOR TROUBLESHOOTING. PERFORMED CENTRAL MAINTENANCE COMPUTER DOWNLOAD AFTER THERMOSTAT INSTALLATION WITH NO FAIL MESSAGES NOTED.

Source: SDR GW4R237272
WARNING INDICATION · 2007-11-29 Unresolved
ATA 2150

Part: SWITCH — FAILED (A/C PACK) · airframe 628 hrs · 387 cycles

IN FLIGHT AC EXPERIENCED AND NR1 PAC OVLD IND WITH NR1 PAC AUTO SHUTDOWN. FLT CREW MADE AN IN-FLIGHT DIVERSION AND UNSCHEDULED LANDING. DOWNLOAD OF THE COMPUTER REVEALED 1 OCCUR OF NR1 PAC OVERTEMP AND 63 NR2 PAC OVERTEMP. LT AND RT PAC OVERTEMP SWITCHES FAILED BENCHCHECK. BOTH SWITCHES WERE REPLACED. DURING THE PAC SYSTEM OPS TEST DISCOVERED THE RT RAM AIR ACTUATOR HAD AN ELEC SHORT CAUSING THE CB TO POP. REPLACED THE RT RAM AIR ACTUATOR AND PAC SYSTEM OPS TESTS. DURING THE COMPUTER DOWNLOAD, 17 OCCURRENCES OF A NR1 PRECOOLER TEMP CONTROL SYSTEM FAIL MESSAGE WAS NOTED. ACCESSED FAN AIR TEMPERATURE THERMOSTATS FOR TROUBLESHOOTING AND UPON REMOVAL IT WAS NOTED THAT THE AMBIENT AIR TEMPERATURE PORTS ON EACH THERMOSTAT HAD SHIPPING PLUGS IN THEM. REMOVED THE SHIPPING PLUGS AND SWAPPED THERMOSTATS FOR TROUBLESHOOTING. PERFORMED CENTRAL MAINTENANCE COMPUTER DOWNLOAD AFTER THERMOSTAT INSTALLATION WITH NO FAIL MESSAGES NOTED.

Source: SDR GW4R237272NR1