N132AA

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
howard L. PattonOperatoron 2013-03-21Operator named in NTSB report
Hawaiian AirlinesOperatoron 2000-12-24Operator named in NTSB report

Accident & incident history

Accident · 2013-03-21 Operator named in NTSB report
AVIAT A-1B No injuries Part 91howard L. Patton

Operated by howard L. Patton (per NTSB report)

Source: NTSB case CEN13CA203
Accident · 2000-12-24 Operator named in NTSB report
McDonnell Douglas DC-10-10 No injuries Part 121Hawaiian Airlines

Operated by HAWAIIAN AIRLINES INC (per NTSB report)

Source: NTSB case DCA01WA009

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

18 reports on file, 1995-12-24 – 2001-09-02.

FLUID LOSS; WARNING INDICATION · 2001-09-02 Unresolved
ATA 2910

Part: HYDRAULIC LINE — CRACKED (HYD CASE DRAIN)

ATB - DURING CLIMB-OUT AFTER DEPARTING LAX, HYD SYSTEM NR 3 ELEV OFF LIGHT ILLUMINATED WITH RAPID LOSS OF NR 3 HYDRAULIC FLUID FLUID. DUMPED FUEL AND RETURNED TO LAX FOR LANDING. ACCOMPLISHED APPROPRIATE ABNORMAL CHECK LIST AND ALTERNATE GEAR EXTENSION. FOUND NR 3 HYD CASE DRAIN LINE ON RIGHT SIDE CRACKED. WAITING FOR NEW LINE. (M)

Source: SDR HALA0100223
Earlier reports · 1995–2000 · 17 reports

2000

WARNING INDICATION · 2000-10-05 Unresolved
ATA 3260

Part: SENSOR — MALFUNCTIONED (MLG)

HNL - FLT 23 - ALL 3 GEAR UNSAFE LIGHTS CAME ON, APPROX 3-4 SECONDS IN CRUISE FLIGHT. CHECKED HYD SYSTEM 3, PRESSURE READ 3200 PSI, HYD QTY READ 9 QTS. LEFT PUMP ON AND RT PUMP OFF. CHECKED GEAR VISUAL INDICATORS, OK. (M)

Source: SDR HALA0000330
FLUID LOSS; WARNING INDICATION · 2000-10-01 Unresolved
ATA 2913

Part: PUMP — FAILED (HYD SYSTEM)

HNL - FLT 212 - NR 2 HYD QTY DROPPED TO 1 GALLON AND NR 2 SYSTEM PRESSURE WENT OT ZERO. FOLLOWED CHECKLIST AND LANDED NORMALLY. REPLACED NR 2 LEFT ENGINE DRIVEN HYD PUMP. SERVICED NR 2 HYD RES PUMP, LEAK CHECK OK. (M)

Source: SDR HALA0000321
OTHER · 2000-09-16 Unresolved
ATA 2612

Part: SOCKET — WORN (NR 1 ENGINE)

FLT 932 - HNL - NR 1 ENGINE B LOOP INOPERATIVE. REMOVED AND REPLACED WORN SOCKETS AT R5-8014 PINS V/P. GROUND TEST OF NR 1 ENGINE B LOOP OK. (M)

Source: SDR HALA0000292
WARNING INDICATION · 2000-09-02 Unresolved
ATA 2610

Part: LOOP — MALFUNCTIONED (NR 2 ENGINE)

LAX - FLT 03 - MANIFOLD FAIL ENGINE NR 2 LIGHT AND MASTER WARNING LIGHTS FLICKERED DURING TAKEOFF ROLL UNTIL AND DURING CRUISE FLIGHT, TEMP AND PRESS GAUGES INDICATE NORMAL READINGS. REPLACED NR 2 MANIFOLD UPPER LOOP P/N 5932361. REQS OPS CHECK. RESET C/B''S, OPS CHECK NORMAL. ACCOMPLISHED TAKEOFF POWER RUN 2 MIN. MCT 2 MIN AND CL POWER 5 MIN WITH NR 2 ACM ON. NO FAULTS NOTED. (M)

Source: SDR HALA0000282
OTHER · 2000-06-09 Matched by certificate designator
ATA 5320

Part: FLOOR SUPPORT — CORRODED (FUSELAGE)

TUL - FOUND FLOOR SUPPORT AT FLOOR LINE STRINGER 27R HAS CORROSION STATION 1902-1921. REPAIRED WEB AT STRINGER 27R, STATION 1902-1921 PER ESO 7349, DATED 6/7/2000. (M)

Source: SDR AALA20001099

1998

NO TEST · 1998-12-24 Matched by certificate designator
ATA 3350

Part: CONNECTOR — LOOSE (ROW 7 HJ)

DFW - DURING OVERNIGHT, MAINTENANCE EMERGENCY EXIT FLOOR PATH LIGHTS AT SEAT 7HJ INOPERATIVE. RESEATED EMERGENCY EXIT FLOOR PATH LIGHT CONNECTOR PIN AT SEAT 7HJ. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA982232

1997

OTHER · 1997-12-01 Matched by certificate designator
ATA 2565

Part: SLIDE — DEFECTIVE (PAX DOOR)

IAD - AT GATE, L2 SLIDE FELL OUT BUT DID NOT SUCCESSFULLY DEPLOY. REPLACED L2 SLIDE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA972294
SMOKE/FUMES/ODORS/SPARKS · 1997-07-19 Matched by certificate designator
ATA 2550

Part: CARGO POD — CONTAMINATED (CARGO COMPT)

TPA - FLT 207 - AFTER TAKEOFF MIA DURING CLIMB-OUT, FUMES WERE NOTED BY F/A IN LOWER LOBE GALLEY. AIRCRAFT DUMPED FUEL AND DIVERTED TO TPA, LANDING WITHOUT INCIDENT. SOURCE OF FUMES WAS DETERMINED TO BE RESIDUAL ODOR FROM EMPTY CARGO POD IN AFT CARGO COMPARTMENT. REMOVED EMPTY CARGO POD AND AIRCRAFT MAINTENANCE FERRY TPA/MIA. PRECAUTIONARY CHECKED ALL OVENS OPERATION IN LOWER LOBE GALLEY WITH NO DEFECTS NOTED. REPLACED 3 PBE UNITS FROM MAIN CABIN USED DURING THE EVENT. SYSTEMS GROUND CHECKED NORMAL OPERATION WITH NO FUMES NOTED. (M)

Source: SDR AALA971287
OTHER · 1997-06-17 Matched by certificate designator
ATA 5320

Part: ROLLER TRAY — CORRODED (BS 1701-1786)

TUL - OMNI ROLLER TRAY IS CORRODED 4TH FROM DOOR. MANUFACTURED AND INSTALLED NEW TRAY PER 51-01-00-05. (M)

Source: SDR AALA971083
OTHER · 1997-06-17 Matched by certificate designator
ATA 5313

Part: LONGERON — CORRODED (BS 1099-1156)

TUL - LONGERON 48 LEFT CORRODED FROM STATION 1099 TO 1156. MANUFACTURED AND SPLICED IN NEW SECTION OF LONGERON 48L FROM STATION 1089 TO 1156 PER SRM 53-10-00 FIG 5. (M)

Source: SDR AALA971082
OTHER · 1997-06-16 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 1119)

TUL - SKIN CORRODED UNDER TEAR STRIP AT STATION 1119 BETWEEN LONG 47L AND 48L. INSTALLED DOUBLER AT STRINGER 48L FS 1119 PER SRM 53-20-00 FIG 6. (M)

Source: SDR AALA971081
OTHER · 1997-06-16 Matched by certificate designator
ATA 5313

Part: LONGERON — CORRODED (BS 1099-1119)

TUL - FOUND LONGERON 48L HAS CORROSION ON OUTBOARD BOTTOM LEG AFT OF STATION 1099 AND ALSO CORRODED BETWEEN STATION 1099 AND STATION 1119. SPLICED IN NEW SECTION OF LONGERON 48L FROM STATION 1089 TO FS STATION 1159 PER SRM 53-10-00 FIG 5. (M)

Source: SDR AALA971080
OTHER · 1997-06-07 Matched by certificate designator
ATA 5753

Part: BEARING — CORRODED (LT TE FLAP)

TUL - OUTBOARD FLAP, OUTBOARD HINGE BEARING BORE HAS CORROSION IN BORE INNER DIAMETER. BORED HINGE BEARING BORE TO 2.344 TO REMOVE CORROSION. EXCEEDS CMN 7327, 57-44-09 PAGE 407 LIMITS, MFG AND INSTALLED NEW BUSHING PER MM 57-44-08. (M)

Source: SDR AALA971047
OTHER · 1997-06-07 Matched by certificate designator
ATA 5753

Part: BEARING — CORRODED (LT TE FLAP)

TUL - OUTBOARD FLAP, INBOARD HINGE BEARING BORE HAS CORROSION IN BORE INNER DIAMETER. BORED HINGE BEARING BORE TO 2.344 TO REMOVE CORROSION (EXCEEDS CMM 7327, 57-44-09 PAGE 407 LIMITS) MFG AND INSTALLED NEW BUSING PER MM 57-44-08. (M)

Source: SDR AALA971046
FLUID LOSS; WARNING INDICATION · 1997-04-19 Matched by certificate designator
ATA 3232

Part: CYLINDER — LEAKING (LT MLG DOOR)

SFO - FLT 65 - EN ROUTE/JFK/SFW, DURING CRUISE, SYSTEM NR 3 HYDRAULIC QTY BEGAN TO DECREASE. ACCOMP ABNORMAL PROCEDURES FOR SYSTEM NR 3 HYD QTY LOSS AND A/C PROCEEDED TO SFO. ACCOMPLISHED ALTERNATE GEAR EXTENSION AND AICRAFT LANDED SFO WITHOUT INCIDENT. REPLACED LEFT MAIN LANDING GEAR DOOR CYLINDER. SERVICED SYSTEM NR 3 HYDRAULICS AND RESTOWED ALTERNATE GEAR EXTENSION HANDLE. SYSTEM LEAK AND GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA970759

1996

OTHER · 1996-10-30 Matched by certificate designator
ATA 5620

Part: WINDOW — CRACKED (CABIN)

MIA - FLT 588 - EN ROUTE SDQ/JFK DURING CRUISE, CABIN WINDOW OUTER PANE AT PAX SEAT 12A CRACKED ALONG EDGE OF FRAME. AIRCRAFT DIVERTED TO MIA AND LANDED WITHOUT INCIDENT. REPLACED OUTER WINDOW PANE AND SEAL AT PAX SEAT 12A. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA961585

1995

FLT CONT AFFECTED · 1995-12-24 Matched by certificate designator
ATA 7830

Part: TR DRIVE — DEFECTIVE (NR 2 ENG)

HNL - FLT NR 14 - DURING CLIMB-OUT, FLT CREW NOTED IMPAIRED CLIMB PERFORMANCE AND SOME AILERON AND RUDDER TRIM REQUIRED TO MAINTAIN WINGS LEVEL. A/C RETURNED TO HNL AND LANDED W/O INCIDENT. AFTER ARRIVAL, NR 2 ENG RT TRANSLATOR COWL NOTED PARTIALLY DEPLOYED. COWL MANUALLY STOWED AND NR 2 REVERSER PLACARDED INOP. SUBSEQUENTLY AT LAX/26, REPLACED NR 2 ENG RT REVERSER HALF AND REPLACED CORE HOUSING AND DRIVE CABLE ON LT REVERSER HALF. ACCOMPLISHED THRUST REVERSER RIGGING BUT CONTINUED PLACARD. SUBSEQUENTLY AT JFK/28, REPLACED NR 2 ENG LT REVERSER HALF, NR 2 ENG THRUST REVERSER DRIVE AND SHUTOFF VLV. ACCOMP LEAK AND GROUND CHECK WITH NO DEFECTS FOUND. SYS GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA960285