N133DN
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
24 reports on file, 1997-07-12 – 2007-10-05.
Part: ACM — FROZEN (LEFT) · airframe 52,629 hrs · 24,455 cycles
LEFT A/C PACK TRIPPED ON TAKEOFF ROLL. RETURNED FOR LANDING DUE TO SMOKE AND FUMES IN THE CABIN AFTER TAKEOFF. FOUND LEFT AIR CYCLE MACHINE SEIZED. REPLACED LT ACM PER M/M 21-51-03-004. LEFT PACK CKS OK, RAN BOTH ENGS. NO SMOKE OR ODOR NOTED.
Part: ENGINE — MAKING METAL (NR 1) · airframe 52,109 hrs · 24,279 cycles
LT ENGINE OIL PRESSURE WENT TO 16-18 PSI (AMBER NUMBERS). OIL QTY AT ZERO. LEFT ENGINE STOP WORKING. REMOVED AND INSPECTED LT ENG OIL FILTER. FOUND FULL OF DEBRIS MAIN ENG OIL CHIP DETECTOR SAME. COULD NOT REINSTALL MAIN E OIL FILTER DUE TO DEBRIS ON HOUSING. REPLACED NR 1 ENG PER TRANS 1T144.
Part: BOTTLE — MALFUNCTIONED (PAX OXYGEN) · airframe 51,867 hrs · 24,206 cycles
2 PAX 02 BOTTLES WOULD NOT FLOW. REPLACED BOTTLES W/ SVCBL BOTTLES FROM STOCK.
Earlier reports · 1997–2006 · 21 reports
2006
Part: SKIN — DENTED (BS 336, S37R) · airframe 48,451 hrs · 22,952 cycles
DENTS IN FUSELAGE SKIN REQUIRING CUTOUT AND REINFORCEMENT VIA TWO EXTERNAL REPAIR DOUBLERS. CORRECTIVE ACTION PER ERA 456425-14 REV A
Part: GASPER FAN — OVERHEATED (CABIN) · airframe 47,287 hrs · 22,464 cycles
TAXI OUT, 5 MINS AFTER NR 2 ENG WAS STARTED ODOR ALL OVER CABIN. RETURNED TO GATE. SMELL HAD DISSIPATED UPON RETURN TO GATE. FOUND GASPAR FAN INOP. RAN BOTH ENGS AND PACKS, NO SMELL NOTED. REPLACED GASPER FAN.
2005
Part: COFFEEMAKER — ARCED (FWD GALLEY) · airframe 46,751 hrs · 22,245 cycles
1RT GALLEY G1A COFFEEMAKER MAKES ELEC ARCING SOUND WHEN TURNED ON. REPLACED SAME.
2004
Part: HOUSING — FRACTURED (SPOILER ACTUATOR) · airframe 43,462 hrs · 20,816 cycles
CENTER HYD SYSTEM FAILURE ON TAKEOFF. QUANTITY ZERO RETURNED. FOUND NBR 6 SPOILER ACTUATOR HOUSING CRACKED. REPLACED NR 6 SPOILER PCA IAW MM 27-61-02.
Part: SKIN — CRACKED (FUSELAGE) · airframe 42,705 hrs · 20,431 cycles
FUSELAGE SKIN CRACKED AT STA 1197+100 AND BL 0 AT LOWER VHF ANTENNA. AREA REPAIR IAW ERA 091394-14.
Part: PIN — DAMAGED (RT MLG) · airframe 42,097 hrs · 20,080 cycles
WHILE WORKING A AIR GROUND DISAGREE PROBLEM. JACKED THE A/C PER THE SETUP AND FOUND THE RIGHT MAIN GEAR SWAYED FROM SIDE TO SIDE WHEN PUSHED INBOARD TO OUTBOARD. FOUND THE BOGIE PIN DAMAGED AND THE RIGHT TRUCK BUSHINGS WORN AND CRACKED. ALSO FOUND THE BOGIE BEAM BUSHINGS DAMAGED AND CRACKED.
Part: FLASHLIGHT — UNSERVICEABLE (CABIN) · airframe 41,613 hrs · 19,817 cycles
DURING MEDICAL EMERGENCY, EEMK, WALKAROUND 02 BOTTLE, FLASHLIGHT, AND BIOHAZARD KIT WERE USED. REPLACED EEMK O2 BOTTLE FLASHLIGHT BIOHAZARD KIT AND EMK. OK CONTINUED SERVICE.
2003
Part: ODOR — DETECTED (CABIN) · airframe 40,555 hrs · 19,304 cycles
IRREG/ LIGHT OUTSIDE MID LAV (AREA 215) ELECTRICAL BURNING/ BALLAST ODOR. INSPECTED BALLASTS IN AREA AND IFE SYSTEM, NO ELECTRICAL BURNING ODOR. LIGHTS AND IFE SYS OPS OK. NO ODOR IN AREA UPON ARRIVAL. CHECKED ACOVE CEILING PANELS IN AREA AND IN LAV. ALL OK.
Part: WIRE HARNESS — DAMAGED (LE FLAP SENSOR) · airframe 39,853 hrs · 18,968 cycles
LEADING EDGE FLAP LIGHT AND EICAS MSG WHEN FLAPS WERE PUT TO 20 DEGREES. REPAIRED S301 SENSOR WIRING.
Part: INDICATOR — INOPERATIVE (TE FLAPS) · airframe 39,765 hrs · 18,928 cycles
AT FL350 FLAP INDICATOR NEEDLES JUMPED TO .5 DEG AND FLUCTUATED TO 0 AND BACK L/E ASSY LIGHT AND MESSAGE. BIT PSEU/FSEU FAULTS NBR 11 I/B SLAT SENSOR..301.. CKD GAPS AND SENSORS W/ELDEC CKS GOOD. RESET PSEU AND OP FLAPS SEV TIMES. NO FAULTS. REPLACED FSEU MM OK FOR SERVICE.
2002
Part: GASKET — LEAKING (NR 1 ENGINE) · airframe 35,852 hrs · 16,958 cycles
LEFT ENGINE FAILED IN FLT ON DESCENT INTO MCO. POM PROCEDURES FOLLOWED, ONLY ABNORMAL INDICATION WAS HIGH FUEL FLOW, COMPARED TO THE RIGHT ENGINE. ON ARRIVAL FOUND LEFT ENGINE IDG FUEL/OIL COOLER GASKET CUT AND LEAKING. REPLACED SAME. FULL POWER RUN UP PER PFHB PERFORMED. LEAK CHECK OK.
2001
Part: FUEL LINE — LEAKING (NR 2 ENGINE) · airframe 35,703 hrs · 16,892 cycles
FOUND FUEL LEAK ON RT ENGINE WHEN OPENED FOR MTC, POSSIBLE FIRE CONDITION EXISTED. FOUND FUEL LINES LEAKING. REPLACED FLEX FUEL LINES FROM FUEL FILTER TO DIFF PRESSURE SWITCH AND TO HEAT EXCHANGER, LEAK CHECK FOUND OK.
Part: LIGHT — INOPERATIVE (AFT DOOR) · airframe 34,495 hrs · 16,318 cycles
LT AFT DOOR EXT EMERGENCY LIGHT INOP RELAMPED. CKS OK.
2000
Part: CIRCUIT BOARD — FALSE INDICATION (FIRE DETECTION) · airframe 31,362 hrs · 14,825 cycles
APPROX 90 KNOTS ON T/O FIRE BELL SOUNDED . T/O REJECTED AT 100 KNOTS NO LIGHT ASSOC WITH BELL. REPLACED CIRCUIT CARDS M1000 AND M618.
1999
Part: FAN — INOPERATIVE (COCKPIT)
AT CRZ FLT FL390, CREW NOTED AN ELECT ODOR. CREW PERFORMED SMOKE IDENTIFICATION/REMOVAL CHECKLIST. ODOR WAS ELIMINATED, C/B H-21 ON P6-4 PANEL WAS POPPED. FWD EXHAUST EQUIPT FAN. NO OTHER SMELLS NOTED FOR REMAINDER OF FLT. REPLACED FAN.
Part: BOTTLE — LOW PRESSURE (RT EMER EXIT)
RIGHT OVERWING SLIDE BOTTLE PRESSURE LOW ALMOST EMPTY.
1998
Part: SKIN — CRACKED (BS 436)
THE FUSELAGE SKIN AT FS 436, STRG 33R TO 34R, WAS DENTED BY GROUND EQUIPMENT. THE AFT EDGE OF THE UNDERLYING SKIN SPLICE STRAP WAS CRACKED AT A FASTENER LOCATION. THE DENTED SKIN AND CRACKED AREA OF THE STRAP WERE TRIMMED OUT AND AN EXTERNAL ALUMINUM REPAIR DOUBLER WAS INSTALLED TO REPAIR THE DAMAGE. THE REPAIR WAS ACCOMPLISHED PER ER/A 364759-14, REV A.
Part: TRANSMITTER — INOPERATIVE (OIL QTY)
CENTER SYSTEM RESVR LIGHT ON OVERHEAD PANEL ILLUMINATED. STATUS PAGE SHOWED CENTER SYSTEM QUANTITY AT ZERO. VERIFIED THAT SYSTEM QUANTITY WAS OK. REPLACED OIL QUANTITY TRANSMITTER, SYSTEM OPS CHECKS NORMAL.
1997
Part: CLAMP — LOOSE (NR 1 ENGINE)
AIRCRAFT 133 EXPERIENCED AN IN FLIGHT SHUTDOWN DUE TO A LEFT ENGINE FIRE WARNING ON CLIMBOUT FROM PDX. PILOTS FOLLOWED POM PROCEDURES. MAINTENANCE FOUND A LOOSE HIGH PRESSURE VALVE INBOAD CLAMP AFTER BACK PRESSURIZING USING APU. RESECURED CLAMP AND RELEAK CHECKED VALVE, ALL NORMAL. RAN NR 1 ENGINE AT TAKEOFF POWER AND NO WARNING NOTED.
Part: COFFEEMAKER — FAILED (GALLEY)
ELECTRICAL BURNING SMELL COMING FROM MID GALLEY AREA WHEN COFFEE MAKER IS USED. REPLACED COFFEEMAKER.
Part: BULB — FAILED (CABIN)
R-3 DOOR EMER EXIT LIGHT INOP. RELAMPED RT OVERWING MOST AFT EMER LIGHT.