A LEAK WAS FOUND ON THE #1 ENGINE HMU DURING POST MAINTENANCE GROUND RUNS. IT WAS DETERMINED TO HAVE A SUSPECTED CRACK OR LEAKING FROM THE SPLIT LINE OF THE HMU. THE AREA WAS TOO CONGESTED TO VISUALLY SEE A CRACK OR WHERE THE LEAK WAS COMING FROM. REMOVED AND REPLACE THE HMU CORRECTED THE DISCREPANCY.
FOUND A CRACK AT RING FRAME X9227, DURING MAINTENANCE.
FLEX SHAFT DAMAGED IN CENTER SECTION. UNIT IS ORGINIAL EQUIPMENT. HARDCARD ENCLOSED. REPLACED WITH SERVICABLE UNIT. 05/10/2004
STARTER GEN WILL NOT ROTATE ENGINE, BRUSHES ARE WORN. REPLACED WITH SERVICABLE UNIT. 04/22/2004
STARTER GEN WOULD NOT START ENGINE. REPLACED WITH SERVICABLE UNIT.
WARRANTY. FLAT ON STOP, LEAKED GLYCOL. REPLACED WITH SERVICABLE UNIT. 03/26/2004
TRANSPONDER IS INOPERATIVE. ATC DOES NOT PICK UP AIRCRAFT. REPLACED WITH SERVICABLE UNIT. 01/23/2004
WARRANTY. NR 1 ENGINE WON'T START. UNIT WAS INSTALLED AT A/CTT 16.6. HARDCARDS ENCLOSED. REPLACED WITH SERVICABLE UNIT. 02/17/2004
ENGINE WOULD NOT START. HARD CARD ENCLOSED. REPLACED WITH SERVICEABLE STARTER GEN.
SQUAKS 1200 INTERMITTENT. NO INPUT. THIS IS THE ORIGINAL UNIT INSTALLED ON 0179/137MH (NEW AIRCRAFT). PART HAS LASTED ONLY 555.9 HOURS. DID NOT RECEIVE AIRCRAFT UNTIL 3/18/03. REPLACED WITH SERVICEABLE UNIT.
MASTER SWITCH WOULD NOT SELF TEST OR WOULD TEST ON ITS OWN. HARD CARD ENCLOSED. REPLACED WITH SERVICEABLE UNIT.
"BLEED AIR" STAYS ON, ON CAD. REPLACED WITH SERVICEABLE UNIT.
NEW EC135 AIRCRAFT. SEAT IS CRUSHED. REPLACED WITH SERVICEABLE UNIT.
EJECTOR WORN BEYOND LIMITS. REPLACED WITH SERVICABLE UNIT. 05/06/2004
TRIPLE TACH BOTH N2 INDICATIONS FALL OFF LINE INTERMITTENTLY. REPLACED WITH SERVICEABLE UNIT.
TRIPLE TACH HAS INTERMITTENT ROTARY RPM. REPLACED WITH SERVICEABLE UNIT.
GEARBOX MOUNT HAS AN INTERNAL FAILURE. REPLACED WITH SERVICEABLE UNIT.
NR 2 AMP OVERLIMIT. INTERMITTENTLY SPIKES BEYOND SERVICEABLE LIMITS. REPLACED WITH SERVICEABLE UNIT.