N1474D
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
6 reports on file, 1995-07-09 – 2001-04-08.
Part: LIGHT — INOPERATIVE (COCKPIT)
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT DOME LIGHT AT FLIGHT DECK INOPERATIVE. REPLACED EMERGENCY EXIT DOME LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
Part: WIRE — DAMAGED (CABIN)
ORD - DURING OVERNIGHT MAINTENANCE, OVERHEAD EMERGENCY EXIT LIGHT AT ROW 11 INOPERATIVE. REPAIRED EMERGENCY EXIT LIGHT WIRE AT CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
Part: DOOR — OUT OF ADJ (ACM)
DFW - FLT 1442 - EN ROUTE DFW-STL - SHORTLY AFTER TAKEOFF RECEIVED CABIN PRESSURE MESSAGE DISPLAYED ON MFDU. UNABLE TO CONTROL CABIN PRESSURE IN THE MANUAL MODE. RETURNED DFW AND LANDED WITHOUT INCIDENT. RE-SEATED RIGHT SIDE ACM ACCESS DOOR. ACCOMPLISHED PRESSURIZATION CHECK. SYSTEM CHECKED NORMAL. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
Part: SWITCH — DEFECTIVE (APU)
DFW - FLT 1067 - EN ROUTE DFW-AMA, ON TAKEOFF APU FAULT LIGHT ILLUMINATED. RETURNED DFW AND LANDED WITHOUT INCIDENT. REPLACED AIRCRAFT APU INTAKE DOOR SWITCH. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
Part: CONNECTOR — DAMAGED (CABIN)
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHT IN AFT SECTION OF AIRCRAFT FLASHING. REPAIRED CONNECTOR IN AFT SECTION. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)
Part: B-NUT — LOOSE (NR 1 HYD SYST)
BNA - FLT 0580 - EN ROUTE DFW/BNA DURING CRUISE, HYDRAULIC SYTEM NR 1 LOW QUANTITY INDICATION ON MFDU. ACCOMPLISHED ABNORMAL PROCEDURES AND AIRCRAFT PROCEEDED TO BNA, LANDING WITHOUT INCIDENT. RESECURED LOOSE B-NUT AT LT THRUST REVERSER CONTROL VALVE STOW LINE. SERVICED HYDRAULIC SYSTEM AND ACCOMPLISHED LEAK AND SYSTEM GROUND CHECK WITH NO DEFECTS FOUND. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)