N147AA
Registered owner: AMERICAN AIRLINES INC, TX (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
107 reports on file, 1995-06-06 – 2026-10-30.
Part: BATTERY — NO TEST (ZONE 200) · airframe 33,881 hrs · 13,387 cycles
AIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 12WL FAILED OPERATIONAL CHECK - MAINTENANCE REPLACED THE BATTERY FOR EMERGENCY POWER SUPPLY UNIT 12WL AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK
Part: FLASHLIGHT — NOT SEATED (ZONE 200) · airframe 33,813 hrs · 13,362 cycles
AIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT JUMP SEAT CLOSEST TO DOOR 1L FLASHLIGHT BELOW SEAT WILL NOT TURN OFF - MAINTENANCE RE-SEATED THE FLASHLIGHT PER AMM 25-65-00
Part: ENGINE — OVERTEMP (NR 1) · airframe 33,475 hrs · 13,231 cycles
AIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO DFW DUE TO THE FLIGHT CREW REPORTING THAT AT ROTATION THEY HEARD A LOUD POP ON ENGINE1 FOLLOWED BY ENGINE 1 EGT OVERTEMP - THE FLIGHT CREW FOLLOWED THE ECAM ACTIONS AND EGT REMAINED WITHIN LIMITS AT REDUCED THRUST - THE AIRCRAFT LANDED SAFELY WITHOUT FURTHER INCIDENT. (OPEN)
Part: ENGINE — OVERTEMP (NR 1) · airframe 3,345 hrs
AIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO DFW DUE TO THE FLIGHT CREW REPORTING DURING CLIMB ENGINE 1 EGT WENT INTO AMBER OR RED APPROX 633 FOR 1 OR 2 MINUTES THE FLIGHT CREW FOLLOWED QRH AND WAS ABLE TO REDUCE EGT - THE AIRCRAFT LANDED SAFELY AT DFW WITHOUT FURTHER INCIDENT ** SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)
Part: SOLENOID VALVE — FAULT MESSAGE (LT ENGINE) · airframe 33,324 hrs · 13,163 cycles
AIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO DFW DUE TO THE FLIGHT CREW REPORTING THAT THE LEFT ENGINE OVERHEATED ON DEPARTURE AFTER PASSSING THRU 11000 FT - THE AIRCRAFT LANDED SAFELY AT DFW AND TAXIED TO THE GATE UNDER ITS OWN POWER - MAINTENANCE FOUND FAULT EG2ILF. SOLENIOD 4020KS2 FAILED OPERATIONAL CHECK AND REPLACED ENGINE 1 SOLENOID 7B *4020KS2* PER AMM 75-32-51
Earlier reports · 1995–2025 · 102 reports
2025
Part: BOTTLE — LOW PRESSURE (ZONE 800) · airframe 30,463 hrs · 12,025 cycles
AIRCRAFT WAS NOT GROUNDED: L1 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER TASK CARD 26L00005005.
Part: BOTTLE — LOW PRESSURE (ZONE 800) · airframe 30,463 hrs · 12,025 cycles
AIRCRAFT WAS NOT GROUNDED: R2 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER TASK CARD 26L00005005.
2024
Part: SLIDE — DAMAGED (ZONE 800) · airframe 27,315 hrs · 10,712 cycles
AIRCRAFT WAS IN BASE MAINTENANCE: BROKEN STRAP CLIP BOTTOM OF FORWARD PASS DOOR SLIDE RIGHT-HAND. REPLACED R1 DOOR SLIDE PER TASK CARD 26L00025011.
Part: WIRE — BROKEN (ZONE 200) · airframe 27,227 hrs · 10,673 cycles
AIRCRAFT WAS NOT GROUNDED: SEAT 20 ABC WHITE EMERGENCY LIGHT INOP. REPAIRED WIRE.
Part: WIRE — DAMAGED (ZONE 200) · airframe 27,227 hrs · 10,673 cycles
AIRCRAFT WAS GROUNDED: SEAT 22 ABC WHITE EMERGENCY LIGHT INOPERATIVE. REPAIRED WIRE.
Part: CONNECTOR — DISCONNECTED (ZONE 200) · airframe 27,209 hrs · 10,665 cycles
AIRCRAFT WAS GROUNDED: L1 DOOR TOP EXIT EMERGENCY LIGHT INOP. TROUBLESHOT L1 EMERGENCY EXIT LIGHT 41WL. RESECURED CONNECTORS.
Part: BOTTLE — LOW PRESSURE (L1 DOOR ASSIST) · airframe 26,595 hrs · 10,372 cycles
AIRCRAFT WAS NOT GROUNDED: L1 DOOR BOTTLE REQ SVC. SERVICED L1 DOOR ASSIST BOTTLE PER AMM 52-10-00.
Part: BOTTLE — LOW PRESSURE (R2 DOOR) · airframe 26,595 hrs · 10,372 cycles
AIRCRAFT WAS NOT GROUNDED: R2 DOOR BOTTLE REQ SVC. SVC DOOR BOTTLE IAW AMM 52-22-00.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 26,372 hrs · 10,282 cycles
AIRCRAFT WAS NOT GROUNDED: LOWER EMERGENCY LIGHT AT FORWARD RIGHTHAND OVERWING EXIT DOOR INOPERATIVE. REMOVED AND REPLACED EXIT MARKER AT FORWARD RIGHT HAND OVERWING EXIT DOOR
Part: DRIVE ASSY — DEFECTIVE (WX RADAR ANTENNA) · airframe 26,326 hrs · 10,263 cycles
AIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO DFW DUE TO THE FLIGHT CREW REPORTED A WEATHER RADAR ANTENNA RED MESSAGE ON THE RADAR DISPLAY. RADAR RETURNS DISAPPEARED AND A GRINDING NOISE WAS HEARD AND FELT IN THE VICINTY OF THE NOSE. THE AIRCRAFT LANDED SAFELY AT CLT AND TAXIED TO THE GATE UNDER ITS OWN POWER. MAINTENANCE REPLACED THE WEATHER RADAR ANTENNA DRIVE ASSEMBLY 7SQ PER AMM 34-41-11. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED.
Part: BATTERY — DISCHARGED (EMERGENCY LIGHTS) · airframe 26,259 hrs · 10,236 cycles
AIRCRAFT WAS NOT GROUNDED: AFT RIGHT EMERGENCY FLASHLIGHT BATTERY IS LOW. REMOVED AND REPLACED AFT RIGHT EMERGENCY FLASHLIGHT BATTERY IAW AMM 25-60-00. OPS CHECK GOOD.
Part: LIGHT — INOPERATIVE (ROW 16) · airframe 26,259 hrs · 10,236 cycles
AIRCRAFT WAS NOT GROUNDED: CEILING EMERGENCY LIGHT ABOVE ROW 16 INOP. FOUND CEILING EMERGENCY LIGHT ABOVE ROW 16 NOT FULLY SEATED RESECURED LIGHT IAW AMM 33-51-11. OPS CHECK GOOD.
Part: BATTERY — DISCHARGED (AFT FLASHLIGHT) · airframe 26,259 hrs · 10,236 cycles
AIRCRAFT WAS NOT GROUNDED: AFT RIGHT EMERGENCY FLASHLIGHT BATTERY IS LOW. REMOVED AND REPLACED AFT RIGHT EMERGENCY FLASHLIGHT BATTERY IAW AMM 25-60-00. OPS CHECK GOOD.
Part: ACTUATOR — TRIPPED (RT SLAT SYS) · airframe 25,217 hrs · 9,766 cycles
AIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED ON FINAL APPROACH INTO AUS DUE TO THE SLATS BEING JAMMED AND A FLIGHT CONTROL SLAT FAULT MESSAGE. THE AIRCRAFT LANDED SAFELY WITHOUT FURTHER INCIDENT AND TAXIED TO THE GATE UNDER ITS OWN POWER. MAINTENANCE FOUND LEFT WING SLAT TRACK 11 ACTUATOR 6041CM TRIPPED AND REPLACED IT. A SATISFACTORY OPS CHECK WAS ACCOMPISHED.
Part: SLAT SYSTEM — BINDING (MAINS) · airframe 25,217 hrs · 9,766 cycles
AIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED ON FINAL APPROACH INTO AUS DUE TO THE SLATS BEING JAMMED AND A FLIGHT CONTROL SLAT FAULT MESSAGE. THE AIRCRAFT LANDED SAFELY WITHOUT FURTHER INCIDENT AND TAXIED TO THE GATE UNDER ITS OWN POWER. (OPEN)
2023
Part: A/C PACK — CONTAMINATED (ZONE 100 - FUSE) · airframe 24,627 hrs · 9,522 cycles
AIRCRAFT WAS GROUNDED: ON DESCENT FL180-FL100 WET/DIRTY SOCK/ OILY ODOR IN /FLIGHT DECK, NOTHING NOTED IN PAX CABIN. MAINTENANCE FOUND SLIGHT CONTAMINATION OF LEFT HAND PACK AND ACCOMPLISHED A DECONTAMINATION OF THE AIR CONDITIONING PACKS PER TASK CARD 26L00021013. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED WITH NO ODORS NOTED.
Part: VENT LINE — CLOGGED (ZONE 100 - FUSE) · airframe 24,597 hrs · 9,510 cycles
AIRCRAFT WAS GROUNDED: DURING DESCENT THROUGH FL180 THE FLIGHT ATTENDANTS REPORTED A STRONG DIRTY SOCKS ODOR IN THE CABIN. **SUPPLEMENTAL REPORT FOR AALA202311279021: MAINTENANCE FOUND THE APU GEARBOX VENT TUBE / LINE CLOGGED AND CLEANED THE VENT TUBE / LINE PER AMM 49-26-55. A SATISFACTORY LEAK / OPEATIONAL CHECK WAS ACCOMPLISHED. ** (CLOSED)
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 24,597 hrs · 9,510 cycles
AIRCRAFT WAS GROUNDED: DURING DESCENT THROUGH FL180 THE FLIGHT ATTENDANTS REPORTED A STRONG DIRTY SOCKS ODOR IN THE CABIN. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)
2022
Part: LIGHT — DEFECTIVE (ZONE 200 - FUSE) · airframe 21,089 hrs · 8,077 cycles
AIRCRAFT WAS NOT GROUNDED: WIRING HARNESS BELOW SEAT 17C HAS FALLEN OFF. MAINTENANCE FOUND THE EMERGENCY LIGHT ASSEMBLY DAMAGED AND REPLACED IT PER AMM 33-51-19. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED .
Part: POWER SUPPLY — NONE (ZONE 200 - FUSE) · airframe 20,903 hrs · 7,996 cycles
AIRCRAFT WAS NOT GROUNDED: AFT LEFT EMERGENCY POWER SUPPLY UNIT 13WL FAULTING. REPLACED EMERGENCY POWER SUPPLY UNIT 13WL AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.
Part: FLOOR PANEL — DELAMINATED (ZONE 100 - FUSE) · airframe 19,852 hrs · 7,577 cycles
AIRCRAFT WAS GROUNDED: AFT CARGO COMPARTMENT FLOOR PANEL 151RF DELAMINATED. REPLACED FLOOR PANEL PER AMM 25-54-11.
Part: FLOOR PANEL — DELAMINATED (ZONE 100 - FUSE) · airframe 19,852 hrs · 7,577 cycles
AIRCRAFT WAS GROUNDED: AFT CARGO COMPARTMENT FLOOR PANEL 152RF DELAMINATED. REPLACED FLOOR PANEL PER AMM 25-55-11.
Part: FLOOR PANEL — DELAMINATED (ZONE 100 - FUSE) · airframe 19,852 hrs · 7,577 cycles
AIRCRAFT WAS GROUNDED: AFT CARGO COMPARTMENT FLOOR PANEL 151NF DELAMINATED. REPLACED FLOOR PANEL PER AMM 25-55-11.
Part: FLOOR PANEL — DELAMINATED (ZONE 100 - FUSE) · airframe 19,852 hrs · 7,577 cycles
AIRCRAFT WAS GROUNDED: FORWARD CARGO CARGO COMPARTMENT FLOOR PANEL 131GF DELAMINATED. REPLACED FLOOR PANEL PER AMM 25-54-12.
Part: MECHANISM — DEFECTIVE (ZONE 800 - DOORS) · airframe 19,679 hrs · 7,500 cycles
AIRCRAFT WAS GROUNDED: FLIGHT DECK LOWER LATCH WILL NOT RELEASE USING THE DOOR HANDLE. REPLACED DOOR LATCH MECHANISM AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 52-51-21.
Part: COVER — INOPERATIVE (ZONE 200 - FUSE) · airframe 19,606 hrs · 7,465 cycles
AIRCRAFT WAS NOT GROUNDED: SEAT 35C EMERGENCY EXIT LIGHT TRIM PIECE FELL OFF. RESECURED EMERGENCY LIGHT COVER AT SEAT 35C PER AMM STANDARD PRACTICE.
Part: ACCUMULATOR — LOW (ZONE 800 - DOORS) · airframe 19,142 hrs · 7,272 cycles
AIRCRAFT WAS NOT GROUNDED: L1 DOOR EMERGENCY CYLINDER / ACCUMULATOR LOW BELOW LIMITS. SERVICED L1 DOOR EMERGENCY CYLINDER / ACCUMULATOR PER AMM 52-10-00.
2021
Part: WIRE — BROKEN (ZONE 200 - FUSE) · airframe 18,681 hrs · 7,071 cycles
AIRCRAFT WAS NOT GROUNDED: BROKEN WIRES AT ROW NUMBER 36 BY SEAT 36A AT FLOOR AREA. REPAIRED WIRING PER AFMM 20-18-1. ESCAPE PATH LIGHT TEST GOOD FOR SERVICE.
Part: DAMPER — LOW PRESSURE (ZONE 800 - DOORS) · airframe 18,655 hrs · 7,061 cycles
AIRCRAFT WAS NOT GROUNDED: L1 DOOR DAMPER PRESSURE BELOW LIMITS FOR PS CHECK. SERVICED L1 DOOR DAMPER PRESSURE WITH NITROGEN PER AMM 52-10-00.
Part: POWER SUPPLY — INOPERATIVE (ZONE 200 - FUSE) · airframe 18,242 hrs · 6,876 cycles
AIRCRAFT WAS NOT GROUNDED: WHEN PERFORMING JOB CARD 26C00033004, FOUND EMERGENCY POWER-SUPPLY UNIT AT DOOR 3R INOPERATIVE. REMOVED AND REPLACED EMERGENCY POWER-SUPPLY UNIT AT DOOR 3R PER AMM 33-51-00.
Part: SLIDE — DEFORMED (PAX DOOR) · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: PASSENGER / CREW DOOR 842 SLIDE RAFT IS DEFORMED. REPLACED SLIDE PER TASK CARD 26L00025011.
Part: POWER SUPPLY — INOPERATIVE (EMERGENCY LIGHTS) · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: INOPERATIVE EMERGENCY POWER SUPPLY UNIT 12WL ON PASSENGER CABIN. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT 12WL ON MID RIGHT PASSENGER CABIN PER AMM 33-51-38-400-001.
Part: POWER SUPPLY — INOPERATIVE (EMERGENCY LIGHTS) · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: INOPERATIVE EMERGENCY POWER SUPPLY UNIT 11WL ON PASSENGER CABIN. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT 11WL ON MID LEFT PASSENGER CABIN PER AMM 33-51-38-400-001-A.
Part: POWER SUPPLY — INOPERATIVE (EMERGENCY LIGHTS) · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: INOPERATIVE EMERGENCY POWER SUPPLY UNIT 10WL ONE PASSENGER CABIN. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT 10WL ON FORWARD PASSENGER CABIN.
Part: HINGE FITTING — WORN (RT ELEVATOR) · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: RIGHT HAND ELEVATOR #2 HINGE FITTING OUTBOARD LUG WORN. REPLACED HINGE FITTING OUTBOARD LUG PER SRM 55-26-41-300-010.
Part: MOUNT BOLT — WORN (NR 1 ENGINE) · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: #1 ENGINE FORWARD MOUNT BOLTS DO NOT PASS TORQUE CHECK (5 EACH). REPLACED MOUNT BOLTS PER AMM 71-21-12-400-010-A.
Part: MOUNT BOLT — WORN (NR 2 ENGINE) · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: #2 ENGINE FORWARD MOUNT BOLTS DO NOT PASS TORQUE CHECK (5 EACH). REPLACED MOUNT BOLTS PER AMM 71-21-12-400-010-A.
Part: WINDOW — FOGGED (COCKPIT LEFT) · airframe 15,797 hrs · 6,081 cycles
AIRCRAFT IN BASE MAINTENANCE: LEFT HAND FLIGHT DECK FIXED WINDOW FOGGED. REPLACED WINDOW PER AMM 56-11-12-000-001-A.
Part: HINGE FITTING — EXCESS PLAY (LT ELEVATOR) · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY, ELEVATOR HINGE ARM 1 ON LEFT HAND HORIZONTAL STABILIZER. REPLACED HINGE ARM END FITTING PER AMM 55-16-42-400-001-A.
Part: CYLINDER — FAILED (PAX DOOR DAMPER) · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE PASSENGER CREW DOOR 841 DOOR DAMPER / EMERGENCY OPERATION CYLINDER FAILS TEST. REPLACED DOOR DAMPER / EMERGENCY OPERATION CYLINDER PER AMM 52-11-14-400-001-B.
Part: HINGE FITTING — EXCESS PLAY (RT ELEVATOR) · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY, ELEVATOR HINGE ARM 1 ON RIGHT HAND HORIZONTAL STABILIZER. REPLACED HINGE ARM END FITTING PER AMM 55-16-42-400-001-A.
Part: SUPPORT FITTING — MIGRATED (PAX DOOR HINGE) · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: MIGRATED PASSENGER CREW DOOR 841 UPPER HINGE BEARING ASSEMBLY. REPLACED UPPER SUPPORT ARM FITTING PER AMM 52-11-31-400-002-A.
Part: SUPPORT FITTING — MIGRATED (PAX DOOR HINGE) · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: MIGRATED PASSENGER CREW DOOR 841 LOWER HINGE BEARING ASSEMBLY. REPLACED LOWER SUPPORT ARM FITTING PER AMM 52-11-31-400-002-A.
Part: SUPPORT — CORRODED (FRM 68 S23L) · corrosion level 2 · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: CORROSION MEASURING L: 0.485 IN, W: 0.395 IN, D: 0.030 IN, ON AFT GALLEY AREA LOWER SILL LOCATED AT FR 68 AND S23L. REPAIRED PER SRM 53-41-14-300-001.
Part: FITTING — CORRODED (AFT GALLEY) · corrosion level 2 · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: CORROSION MEASURING L=3.370 IN, W=0.564 IN, D=0.000 IN, ON CORNER FITTING LOCATED AT AFT GALLEY AREA BETWEEN FR 66 AND FR 68 AT S23R. REPLACED CORNER FITTING PER SRM 51-42-11-801, SRM 51-72-11-911-001 AND DWG D53480505.
Part: SHEAR PLATE — CRACKED (FRMS 69-70 S23R) · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: CRACK FOUND ON SHEAR PLATE LOCATED BETWEEN FR69 TO FR70, 23R. LENGTH: 0.730 INCHES. REPLACED SHEAR PLATE IN AFT GALLEY AREA PER SRM 51-42-11-801, SRM 51-72-11-911-001, AND DRAWING D53474180.
Part: SHEAR PLATE — CRACKED (FRM 69-70 S23L) · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23L. REPLACED SHEAR PLATE PER SRM 51-72-11.
Part: TAB — DELAMINATED (RT WING TE FLAP) · airframe 17,765 hrs · 6,682 cycles
AIRCRAFT IN BASE MAINTENANCE: RIGHT WING TRAILING EDGE OUTBOARD FLAP TAB LOWER SURFACE DELAMINATED AT RIB TAB 4 AND 113 INCHES FROM INBOARD EDGE. REPAIRED FLAP TAB PER EA 330070.
Part: ACCESS DOOR — MISSING (LAV SERVICE) · airframe 17,566 hrs · 6,605 cycles
AIRCRAFT WAS NOT GROUNDED: ON ARRIVAL INTO PHL THE LAVATORY SERVICE DOOR 171AL WAS FOUND TO BE MISSING. **SUPPLEMENTAL REPORT FOR AALA202107212143: INSTALLED SERVICE DOOR AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 52-42-13: ** (CLOSED)
Part: ACCESS DOOR — MISSING (LAV SERVICE) · airframe 17,566 hrs · 6,605 cycles
AIRCRAFT WAS NOT GROUNDED: ON ARRIVAL INTO PHL THE LAVATORY SERVICE DOOR 171AL WAS FOUND TO BE MISSING. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)
Part: BOTTLE — LOW PRESSURE (L1 DOOR DAMPER) · airframe 17,118 hrs · 6,444 cycles
AIRCRAFT WAS NOT GROUNDED: L1 DOOR DAMPER NITROGEN CHARGE LOW. SERVICED L1 DOOR DAMPER NITROGEN CHARGE PER AMM 52-10-00.
Part: ACCUMULATOR — LOW PRESSURE (ASSIST) · airframe 16,594 hrs · 6,273 cycles
AIRCRAFT WAS NOT GROUNDED: FORWARD LEFT (831) DOOR ASSIST ACCUMULATOR NEEDS SERVICED NITROGEN. SERVICED FORWARD LEFT (831) DOOR ASSIST ACCUMULATOR PER AMM 52-22-00.
Part: ACCUMULATOR — LOW PRESSURE (DOOR ASSIST) · airframe 16,594 hrs · 6,273 cycles
AIRCRAFT WAS NOT GROUNDED: RIGHT FORWARD (843) DOOR ASSIST ACCUMULATOR NEEDS SERVICED NITROGEN. SERVICED RIGHT FORWARD (843) DOOR ASSIST ACCUMULATOR PER AMM 52-22-00.
2020
Part: WINDSHIELD — DELAMINATED (R1) · airframe 15,892 hrs · 5,998 cycles
AIRCRAFT WAS NOT GROUNDED. FIRST OFFICERS R1 WINDSHIELD BOTTOM RIGHT APPEARS TO BE DELAMINATING BUT DOES NOT OBSTRUCT VISION. REPLACED WINDSHIELD PER AMM 56-11-11.
Part: LIFE RAFT — OPEN (ROW 13) · airframe 15,720 hrs · 5,929 cycles
AIRCRAFT WAS NOT GROUNDED. 25 MAN LIFE RAFT ON OVERHEAD BIN AT ROW 13. INFLATION POCKET AND ROPE ARE OPENED. REPLACED LIFE RAFT, PER AMM 25-66-00.
Part: CABLE — DAMAGED (L4 GIRT BAR) · airframe 15,565 hrs · 5,879 cycles
AIRCRAFT WAS GROUNDED. L4 DOOR GIRT BAR ARMING TELEFLEX CABLE DAMAGED. TELEFLEX CABLE REPLACED
Part: WARNING MESSAGE — FALSE ACTIVATION (HYD SYSTEM) · airframe 15,513 hrs · 5,855 cycles
AIRCRAFT WAS GROUNDED. HYD B SYS LO PR ECAM 3 MINUTES AFTER DEPARTURE. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO MIA WHERE IT LANDED SAFELY WITHOUT FURTHER INCIDENT. ACCOMPLISHED SYSTEM OPERATIONAL CHECK OF HYDRAULIC B SYSTEM. HYDRAULIC QUANTITY AND PRESSURE WERE NORMAL WITH FLIGHT CONTROL RESPONSE AND PRESSURE SYSTEM CHECKS, PER AMM 29-12-51. NO ECAM MESSAGES NOTED, AIRCRAFT OK FOR SERVICE.
Part: BOTTLE — LOW PRESSURE (L1 DOOR) · airframe 14,976 hrs · 5,648 cycles
AIRCRAFT IN BASE MAINTENANCE - LI DOOR DAMPER, PRESSURE AT 400 PSI. SERVICED L1 DOOR ASSIST BOTTLE PER AMM 52-10-00.
Part: ACCUMULATOR — LOW PRESSURE (L1 DOOR) · airframe 14,672 hrs · 5,530 cycles
AIRCRAFT WAS NOT GROUNDED: L1 ENTRANCE DOOR EMERGENCY CYLINDER ACCUMULATOR LOW. MAINTENANCE SERVICED DOOR ACCUMULATOR TO PROPER PRESSURE PER MM 52-10-00.
2019
Part: BOTTLE — LOW PRESSURE (L1 DOOR ASSIST) · airframe 13,274 hrs · 4,999 cycles
AIRCRAFT WAS NOT GROUNDED: L1 DOOR LEVER WAS DISARMED AT GATE BUT L1 PANEL AND COCKPIT INDICATOR SHOWED DOOR ARMED. MAINTENANCE ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK PER TASK 52-10-00 AND SERVICED DOOR ASSIST BOTTLE TO PROPER PRESSURE.
Part: LIGHT — BROKEN (CABIN) · airframe 13,057 hrs · 4,922 cycles
AIRCRAFT WAS NOT GROUNDED: EMERGENCY EXIT PATH LIGHT BROKEN AT LAVATORY LEFT ISLE. MAINTENANCE REPLACED EMERGENCY PATH LIGHT PER AMM 33-51-04.
Part: CYLINDER — LOW PRESSURE (L1 DOOR) · airframe 12,369 hrs · 4,652 cycles
AIRCRAFT WAS NOT GROUNDED: L1 DOOR EMERGENCY CYLINDER PRESSURE LOW. MAINTENANCE SERVICED CYLINDER TO PROPER PRESSURE PER AMM 52-10-00.
Part: BATTERY — INOPERATIVE (FLASHLIGHT) · airframe 11,208 hrs · 4,233 cycles
FLIGHT ATTENTDENT FLASHLIGHTS AT THE L3 AND R4 WOULD NOT TEST. REMOVED AND REPLACED THE BATTERIES. CHECKED GOOD.
2018
Part: LIFE RAFT — UNWANTED DEPLOY (SEAT 12DEF) · airframe 9,986 hrs · 3,805 cycles
FOUND LIFE RAFT AT SEAT 13DEF OVERHEAD BIN DEPLOYED. REMOVED AND REPLACED LIFE RAFT AT SEAT 13DEF OVERHEAD BIN AS PER AMM 25-66-00.
Part: COVER — ABNORMAL (EVAC SLIDE) · airframe 9,637 hrs · 3,675 cycles
THE AIRCRAFT WAS NOT GROUNDED. DOOR SLIDE BOTTLE PRESSURE WINDOW. R-4 DOOR PLASTIC COVER TO PRESSURE INDICATOR MISSING. REPLACED R4 SLIDE COVER PER AMM 25-62-44.
Part: CYLINDER — LEAKING (DOOR) · airframe 9,424 hrs · 3,593 cycles
DOOR DAMPENER CYLINDER WOULD NOT HOLD PRESSURE. REPLACED THE DOOR CYLINDER.
Part: CYLINDER — LEAKING (L1 DOOR) · airframe 9,407 hrs · 3,588 cycles
FOUND THE L1 DOOR DAMPER AND EMERGENCY CYLINDER LEAKING. REPLACED THE CYLINDER IAW AMM 52-11-14.
Part: POWER SUPPLY — FAULTY (EMERGENCY LIGHT) · airframe 9,397 hrs · 3,585 cycles
DURING AN OPERATIONAL TEST OF THE EMERGENCY LIGHTS, FOUND THE POWER SUPPLY 14WL FAULTY. REPLACED THE POWER SUPPLY IAW AMM 33-51-38.
Part: SEAL — DETACHED (R4 DOOR) · airframe 9,397 hrs · 3,585 cycles
R4 DOOR PRESSURE SEAL WAS MISSING. ATTACHED THE PRESSURE SEAL IAW AMM 527322. OK FOR SERVICE.
Part: BOTTLE — LOW PRESSURE (L1 DOOR ASSIST) · airframe 9,104 hrs · 3,475 cycles
L1 DOOR ASSIST BOTTLE PRESSURE WAS LOW. MAINTENANCE SERVICED THE BOTTLE AND PERFORMED A SATISFACTORY OPERATIONAL CHECK.
Part: ACCUMULATOR — LOW PRESSURE (ZONE 800) · airframe 8,903 hrs · 3,399 cycles
AIRCRAFT WAS NOT GROUNDED. 12L EMERGENCY CYLINDER ACCUMULATOR PRESSURE LOW. SERVICED EMERGENCY CYLINDER ACCUMULATOR PER AMM 52-10-00-614-001-A.
Part: WIRE — DAMAGED (EMERGENCY LIGHT) · airframe 8,719 hrs · 3,335 cycles
EMERGENCY LIGHTS AT SEATS 33C AND 34C, FOUND THE LAMPS INOPERATIVE. FOUND WIRES IN THE CONNECTOR AT SIDEWALL DAMAGED. PINNED THE CONNECTOR IAW ESPM 20-53-55, OPS GOOD.
Part: DAMPER — LOW PRESSURE (L1 DOOR) · airframe 8,285 hrs · 3,180 cycles
L1 DOOR DAMPER PRESSURE LOW. SERVICED THE L1 DOOR DAMPER TO LIMITS IAW MM 52-10-00.
Part: CYLINDER — LOW PRESSURE (L1 DOOR) · airframe 8,087 hrs · 3,107 cycles
L1 DOOR CYLINDER PRESSURE LOW, 500 PSI AND 50 DEGREES FARENHEIT. SERVICED THE DOOR CYLINDER IAW MM 52-10-00.
Part: BOTTLE — LOW PRESSURE (L1 DOOR) · airframe 7,454 hrs · 2,880 cycles
L1 DOOR ASSIST BOTTLE PRESSURE WAS AT 1100 PSI, 50 F. SERVICED THE L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00. OK FOR SERVICE.
Part: BOTTLE — LOW PRESSURE (L1 DOOR) · airframe 7,383 hrs · 2,850 cycles
L1 DOOR EMERGENCY DAMPER PRESURE LOW AT APPROXIMATELY 50 DEGREES F. SERVICED IAW AMM 52-10-00.
Part: CYLINDER — LOW PRESSURE (L1 DOOR) · airframe 7,175 hrs · 2,778 cycles
L1 ENTRY DOOR CYLINDER PRESSURE LOW. MAINTENANCE SERVICED THE CYLINDER IAW AMM 52-10-00.
2017
Part: ACCUMULATOR — LOW PRESSURE (L1 DOOR) · airframe 6,960 hrs · 2,700 cycles
AIRCRAFT NOT GROUNDED. L1 DOOR EMERGENCY CYLINDER/ACCUMULATOR PRESSURE IS LOW. SERVICED L1 DOOR EMERGENCY CYLINDER/ACCUMULATOR PER AMM 52-10-00.
Part: BOTTLE — LOW PRESSURE (L1 DOOR ASSIST) · airframe 6,749 hrs · 2,612 cycles
L1 DOOR ACCUMULATOR PRESSURE WAS LOW. SERVICED DOOR TO PROPER PRESSURE IAW AMM 52-10-00.
Part: BATTERY — FAULTED (EMERGENCY LIGHTS) · airframe 6,748 hrs · 2,610 cycles
EXT R FAULT CODE FOUND DURING EMERGENCY LIGHT TEST. REPLACED THE POWER SUPPLY BATTERY IAW AMM 33-51-00.
Part: CYLINDER — LOW PRESSURE (L1 DOOR) · airframe 6,205 hrs · 2,407 cycles
L1 DOOR CYLINDER HAD LOW PRESSURE. SERVICED THE L1 DOOR CYLINDER IAW AMM 52-10-00.
Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 6,148 hrs · 2,382 cycles
AIRCRAFT WAS NOT GROUNDED. FAILED SELF TEST OF EMERGENCY POWER UNIT SYSTEM TEST 11WL. REPLACED 11WL BATTERY PACK PER AMM 33-51-38.
Part: BOTTLE — LOW PRESSURE (L1 DOOR ASSIST) · airframe 5,525 hrs · 2,147 cycles
L1 DOOR EMERGENCY CYLINDER, ACCUMULATOR PRESSURE LOW. SERVICED L1 DOOR ASSIST CYLINDER TO CORRECT PRESSURE IAW AMM 52-10-00.
Part: DAMPER — LOW PRESSURE (L1 DOOR) · airframe 5,367 hrs · 2,084 cycles
L1 DOOR PRESSURE BELOW MINIMUM PSI. SERVICED L1 DOOR IAW AMM 52-10-00.
Part: BOTTLE — LOW PRESSURE (L1 DOOR) · airframe 5,368 hrs · 2,084 cycles
L1 DOOR PRESSURE BELOW MINIMUM. SERVICED L1 DOOR TO PROPER LIMIT IAW AMM 52-10-00.
Part: BOTTLE — LOW PRESSURE (L1 DOOR) · airframe 5,298 hrs · 2,056 cycles
L1 DOOR DAMPER PRESSURE LOW. SERVICED ACCUMULATOR TO PROPER LEVEL IAW MM 52-10-00.
Part: CYLINDER — LOW PRESSURE (L1 DOOR) · airframe 5,224 hrs · 2,028 cycles
L1 DOOR EMERGENCY CYLINDER HAD PRESSURE LOW. CHARGED THE CYLINDER IAW AMM 52-10-00.
Part: BATTERY — NO TEST (EMERGENCY LIGHTS) · airframe 5,224 hrs · 2,028 cycles
EMERGENCY POWER SUPPLY UNIT 11WL SHOWS BATTERY FAULT. REPLACED BATTERY AT 11WL IAW AMM 33-51-38.
Part: TERMINAL — BURNED (APU STARTER) · airframe 5,058 hrs · 1,960 cycles
APU STARTER FEEDER TERMINAL BURNED. REPLACED THE TERMINAL ON WIRE AT 8KA IAW AWM 49-42-01 AND ESPM 20-48-11-0101. AIRCRAFT WAS GROUNDED.
Part: BOTTLE — LOW PRESSURE (L1 DOOR ASSIST) · airframe 4,985 hrs · 1,928 cycles
L1 DOOR EMERGENCY ASSIST BOTTLE PRESSURE BELOW LIMITS. SERVICED THE BOTTLE IAW AMM 52-10-00.
Part: FLOOR PANEL — DELAMINATED (CARGO BAY) · airframe 4,698 hrs · 1,808 cycles
DURING INSPECTION OF THE AFT CARGO BAY, FOUND FLOOR PANEL 151GF DELAMINATED. REPLACED FLOOR PANEL 151GF PER MM 53-42-14. AIRCRAFT WAS GROUNDED.
Part: LIFE RAFT — OUT OF POSITION (CABIN) · airframe 4,201 hrs · 1,598 cycles
AIRCRAFT WAS NOT GROUNDED. DURING CABIN PASSENGER CHECK, LIFE RAFT WAS FOUND DISTURBED. REMOVED AND REPLACED LIFE RAFT AT ROW 13 IAW AMM 25-66-41-920-001-A. OPERATIONAL CHECK GOOD.
Part: CYLINDER — LOW PRESSURE (L1 DOOR) · airframe 4,152 hrs · 1,575 cycles
AIRCRAFT WAS NOT GROUNDED. L1 EMERGENCY DOOR DAMPER CYLINDER PRESSURE IS LOW. SERVICED CYLINDER IAW AMM 52-10-00. OPERATIONAL CHECK GOOD.
Part: CYLINDER — LOW PRESSURE (L1 DOOR) · airframe 3,998 hrs · 1,522 cycles
AIRCRAFT NOT GROUNDED. L1 EMERGENCY DOOR DAMPER CYLINDER PRESSURE IS LOW. SERVICED CYLINDER IAW AMM 52-10-00. LEAK AND OPERATIONAL CHECK GOOD.
2016
Part: BOTTLE — LOW PRESSURE (L1 DOOR) · airframe 3,863 hrs · 1,481 cycles
L1 EMERGENCY DOOR DAMPER CYLINDER PRESSURE IS 1480 AT 52 DEGREES. SERVICED CYLINDER IAW AMM 52-10-00. OPERATIONAL CHECK GOOD.
Part: CYLINDER — LOW PRESSURE (L1 DOOR) · airframe 2,707 hrs · 995 cycles
L1 DOOR EMERGENCY ASSIST CYLINDER PRESSURE READS BELOW AMM LIMITS. SERVICED THE CYLINDER IAW AMM 52-10-00. LEAK CHECKED GOOD.
Part: UNKNOWN — MALFUNCTIONED (ENGINE) · airframe 2,236 hrs · 823 cycles
DURING TAKE OFF ROLL, THE NR 2 ENGINE ACCELERATION LAGGED BEHIND NR 1 AND AN ECAM THRUST LEVER DISAGREE MESSAGE GENERATED. TAKE OFF WAS ABORTED AT APPROXIMATELY 40 KNOTS. ECAM MESSAGE EXTINGUISHED AND FMGC WOULD NOT ALLOW RESELECTION OF RUNWAY OR CHANGE OF POWER SETTINGS. MAINTENANCE ACCOMPLISHED AFS TESTS IAW TSM 22-31-00 WITH NO FAULTS FOUND. ACCOMPLISHED LAND TEST IAW AMM 22-97-00 WITH NO FAULTS FOUND. SYSTEM CHECKED NORMAL.
2015
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 357 hrs · 140 cycles
DURING APPROACH, AT APPROX 2300 FEET, ACFT WENT TO TOGA-GIA MODE AT MANNED SPEED SELECTION. ABORTED APPROACH. DURING GO AROUND MADE SEVERAL ATTEMPTS DISCONNECT TOGA FROM AUTO THRUST SYS, EACH TIME POWER WENT BACK TO TOGA. AUTOPILOT 1 DISCONNECTED SEVERAL TIMES DURING EVENT. ACCOMPLISHED OPERATIONAL TEST OF THE AUTO THRUST SYS ISOLATION, WITH AIBS, IAW AMM 22-30-00 & LAND CAT III CAPABILITY TEST IAW AMM 22-97-00 WITH NO FAULTS FOUND. SYS CHECKED NORMAL.
1995
Part: EEL — DEFECTIVE (CABIN)
SFO - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHT EXIT LIGHT AT 3R DOOR FOUND INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT EXIT LIGHT AT 3R DOOR. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)
Part: EEL CONNECTOR — BROKEN (CABIN)
SFO - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS AT RT SIDE OF SERVICE CENTER INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT CONNECTOR AT RT SIDE OF SERVICE CENTER. SYSTEM GROUND CHECKED NORMAL OPERATION. (W)
Part: EEL WIRE — FAILED (CABIN)
LAX - FLT 161 - AT THE GATE DURING PS CHECK, UNABLE TO TURN OFF EMERGENCY FLOOR LIGHTS IN FIRST CLASS CABIN AND FORWARD SERVICE CENTER. WATER WAS LEAKING FROM SERVICE CENTER TRASH BIN, CREATING WIRING SHORT. REPLACED FORWARD SERVICE CENTER TRASH BIN AND DRIED CARPETS AND WIRING. SYSTEM GROUND CHECKED NORMAL OPERATION. (W)
Part: EEL CONNECTOR — DEFECTIVE (CABIN)
SFO - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS AT RT AISLE BETWEEN MID GALLEY AND PASSENGER SEAT ROW 19G INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT CONNECTOR BY PASSENGER SEAT 19G. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)