N148Z

SHORT BROS SD3-60 SHERPA · 1998 · Valid Registration

Registered owner: USDA FOREST SERVICE, ID (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
USDA Forest ServiceOperator2016-10-13 – 2016-10-13Operator named in NTSB report

Accident & incident history

Inc · 2016-10-13 Operator named in NTSB report
SHORT BROS SD3 60 SHERPA None injury PUBUUSDA Forest Service
Source: NTSB case WPR17IA007

Maintenance disclosures

W · 2004-08-15 Unresolved
ATA 1430

INSPECTION AFTER TURBULENT AIR, DISCOVERED BOTH UPPER FWD WING BOLTS AND NUTS WERE ONLY INSTALLED HAND TIGHT. REVEALED THAT WING BOLT INSP HAD BEEN COMPLETED 116.8 HOURS BEFORE. WING BOLT RETORQUE CHECK HAD BEEN COMPLIED WITH 72.8 HOURS AFTER THAT. AIRCRAFT HAS WING STRAP INSTALLED. THE STC ICA AND SB ONLY MENTIONS PROCEDURES FOR TORQUEING THE LWR FWD BOLTS. PROCEDURE FOR TORQUEING REMAINDER BOLTS IS LEFT TO MFG SIRM. WING BOLT MAINT, SIRM STATES TO CHK TORQUE IAW FIGURES SHOWN. IT APPEARS THAT REQUIRED TORQUE COULD BE MET, EVEN THOUGH NUTS WERE NOT FULLY ENGAGED, OR CORRECTLY TORQUED TO BEGIN WITH, DUE TO DOWNWARD PRESSURE EXERTED ON WING. SIRM STATES (ENSURE WING IS PROPERLY SUPPORTED FOR MAINT).

Source: SDR 2004FA0000796 · FAA SDRS