N151AE
Registered owner: PHI HEALTH LLC, AZ (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| PHI HEALTH,LLC (VE7A) | Certificate holder | — | Matched by certificate designator |
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
DURING CLIMB OUT FROM HOSPITAL, STRONG FUMES AND LIGHT SMOKE ENTERED CREW CABIN. TURNED AIR CONDITIONER OFF, OPENED WINDOWS AND VENTS, DIVERTED, APPROXIMATELY 1 TO 2 MILES AWAY AND PERFORMED PRECAUTIONARY LANDING. MX REPLACED THE AIR CONDITIONER COMPRESSOR DRIVE BELT.
ENGINE FIRE WARNING LIGHT ILLUMINATED DURING START UP. CLEANED CORROSION FROM LT REAR FIRE DETECTOR WIRE TERMINALS IAW MM 26-10-10, ASB072760 AND EMM TASK 26-11-00-050-001. PERFORMED OPERATIONAL CHECK WITH PILOT. CHECKS GOOD.
UPON SERVICING OF THE MAIN GEAR STRUTS, THE PLUGS THAT THE SHRADER VALVES SCREW INTO WERE FOUND CRACKED FROM THE THREADED AREA OUTWARD. THE LT SIDE WAS FOUND VISUALLY, THE RT SIDE WAS FOUND WITH DYE PENETRANT. SUSPECT THE SHRADER VALVES MAY HAVE BEEN OVERTORQUED.