N1619A
Registered owner: ATLAS AIR INC, NY (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
297 reports on file, 2018-09-21 – 2026-10-24.
Part: PROXIMITY SWITCH — FAULTED (ZONE 700) · airframe 87,108 hrs · 17,436 cycles
RIGHT REVERSER LIGHT INDICATOR FLICKERED ALONG WITH NOSE GEAR LIGHT AND RIGHT GEAR LIGHT. LEFT GEAR REMAINED ON STEADY FOR 30 MINUTES. LP 2030222 ITEM 1: CLEANED D4149P AND PERFORMED OPS CHECK. OPS CHECK GOOD, MSG CLEARED IAW SWPM 20-10. LP 2030222 ITEM 2: REPLACED S-263 ON R/H GEAR PER SWPM 20-30, INSP MADE PER BOEING RECOMMENDATION. NO TROUBLE FOUND.</P>)
Part: PSEU — FAULTED (ZONE) · airframe 87,024 hrs · 17,405 cycles
ENTRY DOOR AND EMER DOOR DISCRETE LIGHTS ON OVERHEAD PANEL INOPERATIVE. REMOVED AND REPLACED PSEU IAW AMM 32-09-04-704-013. OPS CHKD GOOD.
Part: PROXIMITY SENSOR — FALSE ACTIVATION (ZONE 700) · airframe 87,021 hrs · 17,404 cycles
40 MINS INTO FLIGHT @ FL340, RT LANDING GEAR DISCREET LIGHTS, AMBER REV LIGHT, AND ENTRY DOORS/EMER DOORS DISCREET LIGHTS ILLUMINATED. LANDING GEAR DISCREET LIGHTS EXTINGUISHED 10 MINS AFTER. LDG GEAR MONITOR STATUS MSG. REPLACED S-242 AND S-564 PROXIMITY SENSORS AND HARDWARE. INSPECTED WIRE FOR MLG PROXIMITY SWITCHES AND GEAR HANDLE. NO TROUBLE FOUND IAW AMM 32-61-02.
Part: PSEU — INOPERATIVE (ZONE 200) · airframe 87,019 hrs · 17,403 cycles
APPROX 1 HR AFTER T/O DURING CRUISE @ FL360, LEFT LANDING GEAR DISCRETE LIGHT ILLUMINATED. INTERMITTENT - RT LANDING GEAR DISCRETE LIGHT ILLUMINATED. IN FLIGHT DURING CRUISE, INTERMITTENT RT AMBER REV; NO ASSOCIATED EICAS MESSAGE.(<P>ANC MX PERFORMED FIM 32-09 FT 804, CHECKED PROX SWITCHES FOR PROPER CLEARANCE AND CLEANLINESS. PERFORMED PSEU TARGET TEST FOR ALL RELATED GEAR PROX SWITCHES. ALL TESTS OK, SUSPECT INTERMITTENT PSEU FAULT.</P> / <P>LP 2029603 P2: REF FIM 78-36-805, CHECKED PROX SWITCHES FOR PROPER CLEARANCE AND CLEANLINESS. PERFORMED PSEU TARGET TEST FOR ALL RIGHT ENGINE T/R PROX SWITCHES. ALL TESTS OK, SUSPECT INTERMITTENT PSEU FAULT.</P> / <P>LP 2029604 M4: AFTER BLOCK IN, STATUS MSG Ãâ¬ÅLDG GEAR MONITORÃâ¬? APPEARED. R&R PSEU IAW AMM 32-09-04. PERFORMED PSEU GROUND TEST. TEST OK, SUSPECT INTERNAL LOGIC CARD #3 CAUSING T/R AND LANDING GEAR INDICATION ISSUES. NO FURTHER DEFECTS NOTED.</P>)
Part: BATTERY — INOPERATIVE (FLASHLIGHT) · airframe 87,021 hrs · 17,404 cycles
FLASHLIGHT NEXT TO LAV DEAD BATTERY, NOTICED POST FLIGHT. MX IN WORK WHILE IN AOGM FOR ATB, MULTIPLE ERRONEOUS LANDING GEAR, T/R AND DOOR INDICATIONS. AOGM ETR 07OCT26. REMOVED AND REPLACED FLASHLIGHT & BATTERY NEXT TO LAV. OPS CHECK GOOD IAW AMM 20-11-00, 25-64-00 & B767 F25-EEL. THIS CLOSES DMI
Part: LINE — DISCONNECTED (RT ENGINE) · airframe 86,377 hrs · 17,196 cycles
SHORTLY AFTER TAKEOFF (AROUND 2000 AGL) GOT R ENG EEC MODE EICAS MSG. NO INDICATION OF EPR ON RIGHT ENGINE. FOUND THE PT2 LINE DISCONNECTED AT THE RIGHT ENGINE EEC. RECONNECTED PT2 PER AMM 77-11-00/001. PERFORMED ENGINE RUN IAW AMM 71-00-00. ALL OPS CHECKED GOOD.
Part: SWITCH — FAULTED (ZONE 800) · airframe 86,386 hrs · 17,197 cycles
AFTER TAKEOFF AROUND 3000FT AGL, GOT E/E ACCESS DOOR EICAS MESSAGE. R & R E/E ACCESS DOOR SWITCH PER AMM 52-71-00. OPS CHECK GOOD. DMI 253051 CLOSED</P>)
Part: SKIN — DAMAGED (ZONE 100) · airframe 86,376 hrs · 17,195 cycles
DURING LIGHTNING STRIKE INSPECTION, FOUND 5EA BURN MARKS ON FUSELAGE SKIN AT STA.522-544. STRG 39L-39R. PERMANENT REPAIR HAS BEEN ACCOMPLISHED AS PER SRM 53-00-01-2R-1, REPAIR 1. REV. 131.
Part: SIGN — BROKEN (ZONE 200) · airframe 86,376 hrs · 17,195 cycles
DURING GVI OF MAIN DECK CARGO COMPARTMENT, FOUND SELF LUMINOUS EXIT SIGN, ATTACHED OVER THE ENTRY HATCH FOR THE MAIN CARGO, BROKEN. SELF ILLUMINATED EXIT SIGN REPLACED IAW AMM 33-51-02 REV.147 NO FURTHER DEFECTS NOTED.
Part: SKIN — DAMAGED (ZONE 100) · airframe 86,376 hrs · 17,195 cycles
DURING LIGHTNING STRIKE INSPECTION, FOUND 1EA BURN MARK ON FUSELAGE SKIN AT STA. 654+88-654+110. STRG 39L-39R. PERMANENT REPAIR HAS BEEN ACCOMPLISHED AS PER SRM 53-00-01-2R-1, REPAIR 1. REV. 131.
Part: SKIN — DENTED (ZONE 100) · airframe 86,376 hrs · 17,195 cycles
FOUND ONE DENT ON THE FUSELAGE SKIN RH SIDE BEHIND MLG WW ABOVE THE RAT HOUSING. GOUGE ON FUSELAGE SKIN STA 1153-1175 AT STR 29R IS OUT OF LIMITS IAW SRM 53-00-01-1A-1. ALLOWABLE DAMAGE 1 REV 131. PERFORMED SKIN REPAIR IAW SRM 53-00-01-2R-1 REPAIR 1 REV 131.<
Part: SWITCH — SHORTED (ZONE 400) · airframe 86,376 hrs · 17,195 cycles
DURING PREPARATION FOR ENG #2 COOLING BAROMETRIC SWITCH, OPS CHK FOUND DAMAGE TO A SCREW AT NACELLE ZONE VENT SOV. AFTER INVESTIGATING, WE FOUND THAT THIS SCREW WAS TOUCHING THE FEEDER CABLES. TWO CABLES GOT DAMAGED AND PRODUCED ARCING TO THE VALVE HOUSING SCREW. THIS DAMAGE OCCURRED DUE TO WRONG FEEDER CABLE CLAMP INSTALLATION. THE TWO CLAMPS WERE INSTALLED 180 DEGREES IN THE WRONG DIRECTION, WHICH LED TO NOT ENOUGH CLEARANCE TO THE VALVE BODY. LACK OF PROCEDURE KNOWLEDGE: DUE TO WRONGLY INSTALLED CLAMPS AT ENG #2 PERFORMED ENG 1 IDG POWER FEEDER PRIMARY INSULATION REPAIR AND REROUTE IAW SWPM 20-10-13, REV. 91. NO FURTHER DEFECTS NOTED.
Part: SKIN — DAMAGED (ZONE 100) · airframe 86,376 hrs · 17,195 cycles
DURING LIGHTNING STRIKE INSPECTION, FOUND 1EA BURN MARK ON FUSELAGE SKIN AT STA.654+44-654+66, BTWN. STRG 39L-39R. PERMANENT REPAIR HAS BEEN ACCOMPLISHED AS PER SRM 53-00-01-2R-1, REPAIR 1. REV. 131.
Part: SKIN — DAMAGED (ZONE 100) · airframe 86,376 hrs · 17,195 cycles
DURING LIGHTNING STRIKE INSPECTION, FOUND 5EA BURN MARKS ON FUSELAGE SKIN AT STA. 522-544, BTWN STRG 39L-39R. REPAIR PARTS HAVE BEEN INSTALLED AS PER SRM 53-00-01-2R-1, REPAIR 1. REV. 131.
Part: FEEDER CABLE — WRONG PART (ZONE 100) · airframe 86,376 hrs · 17,195 cycles
DURING PREPARATION FOR NR 2 ENG COOLING BAROMETRIC SWITCH OPC FOUND DAMAGED SCREW AT NACELLE ZONE VENT SHUTOFF VALVE. AFTER INVESTIGATION FOUND THAT THIS SCREW WAS TOUCHING THE FEEDER CABLES. TWO CABLE GOT DAMAGED AND PRODUCED ARCING TO THE VALVE HOUSING SCREW. THIS DAMAGE OCCURED DUE TO WRONG FEEDER CABLE CLAMP INSTALLATION. THE TWO FIRST CLAMPS WERE INSTALLED 180 DEGREE IN THE WRONG DIRECTION WHICH LEAD TO NOT ENOUGH CLEARANCE TO THE VALVE BODY.
Part: ELT — INOPERATIVE (ZONE 200) · airframe 86,130 hrs · 17,060 cycles
ELT LOCATED RT AFT OF OBSERVERS SEAT INOP. REQ REPLACEMENT(<P>R/R ELT FROM RH AFT OF OBSERVERS SEAT IAW B767 AMM 25-26-03. NO DEFECTS NOTED</P>)
Earlier reports · 2018–2025 · 281 reports
2025
Part: ELT — LOOSE (ZONE 200) · airframe 86,035 hrs · 17,019 cycles
ELT NEAR RH CB PANEL TAPE IS LOOSE & 1 LATCH WILL NOT CLOSE. INSTALLED TAMPER TAPE ON FWD ELT IAW AMM 25-61-05-200-801. NO DEFECTS NOTED.
Part: ENGINE — NO DISCREPANCY · airframe 85,746 hrs · 16,918 cycles
ON TAKE OFF ROLL, RECEIVED LT & RT ENG BLEED EICAS MSG & MASTER CAUTION LIGHT. RTO, PERFORMED BITE TEST IAW FIM 36-20 FT 804. FOUND 0 MSG ON THIS FLT LEG. EICAS MSG CLEARED. ALSO, PERFORMED WEU TEST IAW AMM 31-51-00, OPS CHK GOOD. FOUND MSG TO BE NORMAL.
Part: SHUTOFF VALVE — FAULTED (ZONE 200) · airframe 85,711 hrs · 16,909 cycles
C HYD SYS PRESS EICAS MESSAGE DISPLAYED IN FLIGHT, HMG INOP. HYD PRESS INDICATION OPERATES NORMAL PER AMM 29-31-00-001. PERFORMED ADP SYS TEST PER B767 AMM 29-11-00. NO DEFECTS NOTED. TRANSFER TO DMI 239843 PER MEL 24-25-01-01D CAT A. R & R SOV PER AMM 24-25-03, NO HELP. T/S TO RELAY K858 IAW WDM 24-25-11, OPS CHK GOOD IAW AMM 24-25-00. DMI 239843 CLOSED. PLACARD REMOVED.
Part: REGULATOR — LEAKING (OXYGEN TANK) · airframe 85,711 hrs · 16,909 cycles
PAX OXYGEN TANK (BOTTLE 2) REGULATOR LEAK(<P>REMOVED AND REPLACED PAX OXYGEN TANK REGULATOR IAW B767 AMM 35-11-03. LEAK & PRESSURE CHK OK</P>)
Part: FLASHLIGHT — NO DISCREPANCY (ZONE 200) · airframe 85,544 hrs · 16,852 cycles
L1 DOOR ENTRY WAY EMERGENCY FLASHLIGHT INOPERATIVE. OPS CHK ENTRY WAY FLASHLIGHT IAW AMM 25-05-03, OPS CHECK GOOD.
Part: LENS — SCRATCHED (SMOKE GOGGLES) · airframe 85,528 hrs · 16,849 cycles
OBSERVER SMOKE GOGGLES LENS SCRATCHED. REPLACED OBS SMOKE GOGGLE PER IPC 25-64-54-01B ITEM 30. NO FURTHER DEFECTS NOTED.
Part: STRUCTURE — NO DISCREPANCY · airframe 85,351 hrs · 16,815 cycles
AT APPROXIMATELY 310 KIAS, APPROXIMATELY 10 KNOTS OVERSPEED WITH OVSPD WARNING WHILE IN DESCENT 0 FLAPS ADVISE FLT LEVEL 200. WORK WITH MCC AND PER AMM 05-51-08. COMPLETED PHASE 1 INSPECTION, NO DAMAGE WAS FOUND. LOG ITEM CLOSED.
Part: FMC — ODOR (ZONE 200) · airframe 85,269 hrs · 16,799 cycles
CAPT REPORTS ELECTRICAL ODOR IN COCKPIT AFTER BLOCK, DETERMINED CAPT FMS CDU BLANKED AND CIRCUIT BREAKER OPEN.(<P>COLLARED CIRCUIT BREAKER, PART ORDERED FOR NGO. REPLACED CA FMC CDU IAW AMM 34-61-02. CLEARED MDDR 233639. NO FURTHER DEFECTS NOTED.</P>)
Part: ELT — ABNORMAL (ZONE 200) · airframe 84,355 hrs · 16,630 cycles
ELT AT ENTRANCE HAS MASKING TAPE OVER THE WATER SOLUABLE TAPE(<P>R/R L1 DOOR L1 & BRACKET STRAP OPS CHK GOOD IAW AMM 25-63-03-400-802 & AIPC 25-63-52-97. DMI 224932 CLOSED</P>)
2024
Part: LAMP — BURNED OUT (ZONE 200) · airframe 83,666 hrs · 16,502 cycles
EMERGENCY LIGHTS "UNARMED" DISCRETE LIGHT HAS BURNED OUT LIGHT BULB(<P>RELAMPED EMERGENCY UNARMED LIGHT PER AMM 33-10-00. OPS CHECK NORMAL</P>)
Part: SCREEN — CLOGGED (COOLING DUCT) · airframe 83,364 hrs · 16,444 cycles
ATB - FWD EQUIP OVHT EICAS MSG. WENT TO STBY IAW QRH, DID NOT CLEAR. WENT TO OVRD IAW QRH, EICAS MSG CLEARED. DID NOT ENTER ETOPS(<P>FOUND EQPT COOL SUPPLY AIR INLET GRILL DIRTY AND PARTIALLY BLOCKED. CLEANED PER AMM 21-58-10. FOUND SUPPLY FAN SCREEN EQUIPMENT COOLING DIRTY AND PARTIALLY BLOCKED. CLEANED PER AMM 21-58-22. PERFORMED GVI OF EQUIPMENT COOLING SUPPLY AND EXHAUST FAN ASSOCIATED WIRING, CLAMPS AND CONNECTORS PER SWPM 20-10-06. NO DISCREPANCIES FOUND AND OK FOR SERVICE AT THIS TIME. VERIFIED BOTH EQUIP COOLING SUPPLY AND EXHAUST FANS CLEAN AND SKIP FREELY. OPS CHECKED EQUIPMENT COOLING SYSTEM IAW AMM 21-58-00, OPS CHECKED NORMAL, NO ASSOCIATED MESSAGES. OK FOR SERVICE AT THIS TIME.&NBSP;</P>)
Part: FIRE SEAL — BROKEN (T/R DOOR) · airframe 83,283 hrs · 16,423 cycles
ENG 2, RIGHT T/R DOOR, UPPER AFTER SECTION, FIRE SEAL BROKEN(<P>FIRE SEAL WAS REPAIRED IAW AMM 78-00-00-038-001-N00. NO FURTHER DEFECTS NOTED</P>)
Part: SKIN — DETACHED (RT NR 7) · airframe 83,283 hrs · 16,423 cycles
RH WING, SLAT #7, SURFACE INNER SIDE, UPPER AND LOWER AREA WITH SEVERAL POINTS OF DETACHED.(<P>RH WING, SLAT #7, WAS REPLACED IAW AMM 27-81-01-024-001 AND AMM 27- 81-01-424-143. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED</P>)
Part: SEAL — DAMAGED (THRUST REVERSER) · airframe 83,283 hrs · 16,423 cycles
ENG 2, RIGHT T/R DOOR, UPPER SECTION, FIRE SEAL, RESTORE SEALANT (THE ENTIRE PERIPHERY)(<P>FIRE SEAL WAS REPAIRED IAW AMM 78-00-00-038-001-N00. NO FURTHER DEFECTS NOTED</P>)
Part: ACCESS PANEL — WORN (ZONE 100) · airframe 83,283 hrs · 16,423 cycles
SYST LH HYD BAY, (ACCESS PANEL: 437BL) INNER RIGHTSIDE, LOWER REAR CORNER AREA, PLATE-STRICKER WITH WORN.(<P>LOWER REAR CORNER AREA, PLATE ASSY WAS REPLACED SRM 51-10-02-0G-0. NO FURTHER DEFECTS NOTED</P>)
Part: SKIN — WORN (ZONE 500) · airframe 83,283 hrs · 16,423 cycles
LH WING, AT WBL 97.5 , BTW STA 785.9 AND STA 830 WING LOWER SKIN WITH WEAR.(<P>LH WING, AT WBL 97.5 , BTW STA 785.9 AND STA 830 WING LOWER SKIN DAMAGE WAS REPAIRED IAW FVCI #24153-3 AN APPROVAL FORM FAA 8110-3 WAS ISSUED. NO FURTHER DEFECTS NOTED</P>)
Part: FUEL CELL — LEAKING (ZONE 600) · airframe 83,283 hrs · 16,423 cycles
RH WING, LOWER SKIN BETWEEN WBL 97.95 TO WS 226.3 AND STGR 10 WITH EVIDENCE OF FUEL LEAK(<P>FUEL LEAK WAS REPAIRED IAW AMM 28-11-00-308-013. LEAK CHECK GOOD</P>)
Part: PCA — LEAKING (ZONE 500) · airframe 83,283 hrs · 16,423 cycles
LEFT WING, OUTER AILERON, INNER PCA, WITH EVIDENCE OF HYD LEAKAGE(<P>LEFT WING, OUTER AILERON, INNER PCA, WAS REPLACED, ADJUSTED AND LEAK TEST WAS PERFORMED IAW AMM 27-11- 49-422-028 AND AMM 27-11-49-022-014. NO LEAKS WERE FOUND.</P>)
Part: SKIN — CRACKED (ZONE 100) · airframe 83,283 hrs · 16,423 cycles
AT FWD ENTRY DOOR CUTOUT AFT LOWER CORNER ONE HOLE WITH CRACK INDICATION ON BOTH STRUCTURES FUSELAGE SKIN AND BEAR STRAP APPROX TO THE 10 OôCLOCK.(<P>HOLE INDICATION ON BOTH STRUCTURES FUSELAGE SKIN AND BEAR STRAP APPROX TO THE 10 OôCLOCK. CRACK WAS REPAIRED IAW SRM 53-10-01-2R-1. NO FURTHER DEFECTS NOTED</P>)
Part: FIRE SEAL — DETACHED (ZONE 400) · airframe 83,283 hrs · 16,423 cycles
ENGINE ONE NACELLE STRUT FIRE SEAL DETACHED ON FWD CORNER LH AND RH SIDE(<P>ENGINE ONE NACELLE STRUT FWD CORNER LH AND RH SIDE; SEAL WAS REPAIRED IAW AMM 54-54-03-308-014. NO FURTHER DEFECTS NOTED</P>)
Part: BRACKET — CORRODED (ZONE 100) · airframe 83,283 hrs · 16,423 cycles
BULK CARGO COMPARTMENT, AFT BULKHEAD, AFT STA 1540, BTW S-38R, AND S-39R, BRACKET WITH EVIDENCE OF CORROSION.(<P>BRACKET WAS REPLACED IAW SRM 51-10-02-0G-0. NO FURTHER DEFECTS NOTED</P>)
Part: JUMPER — BROKEN (ZONE 600) · airframe 83,283 hrs · 16,423 cycles
RH WING, FUEL TANK, INSIDE ACCESS PANEL 632DB, BROKEN BONDING JUMPER (2E/A'S) BTW RIB 6/7.(<P>THE BROKEN BONDING JUMPER (2E/A'S) ON RH WING, FUEL TANK, INSIDE ACCESS PANEL 632DB, BTW RIB 6/7 WERE REPLACED IAW SWPM 20-20-10 REV</P>)
Part: SKIN — DETACHED (LT AILERON) · airframe 83,283 hrs · 16,423 cycles
LEFT WING, LEFT INBOARD AILERON, LEADING EDGE MIDDLE AREA DETACHED.(<P>LEFT WING, INBOARD AILERON, LEADING EDGE MIDDLE AREA WAS REPAIRED IAW SRM 57-60-01-2R-1 FIG 201 SHEET 9 PAG 1-10 AND SRM 51-70-17-0G-0 PAR 4G FIG 15</P>)
Part: FIRE BOTTLE — EXPIRED (NR 2 ENGINE) · airframe 83,283 hrs · 16,423 cycles
ENG 2 BOTTLE EXTINGUISHER #2 DATE OFF(<P>ENG 2 BOTTLE EXTINGUISHER #2 WAS REPLACED AND TEST WAS SATISFACTORY IAW AMM 26-21-03-424-095</P>)
Part: SEALANT — MISSING (ZONE 600) · airframe 83,283 hrs · 16,423 cycles
RH WING, INSIDE FUEL TANK REAR SPAR, MISSING FILLET SEALANT ON SHUT OFF VALVE (2 E/A'S) BTW RIB 1/6.(<P>RH WING, INSIDE FUEL TANK REAR SPAR, FILLET SEALANT ON SHUT OFF VALVE WAS APPLIED IAW AMM TASK 28-21-02-404-021. NO FURTHER DEFECT NOTED</P>)
Part: SKIN — CORRODED (RT NR 7 SLAT) · corrosion level 2 · airframe 83,283 hrs · 16,423 cycles
RH WING, SLAT #7, SURFACE INNER SIDE, AREA UPPER MIDDLE, WITH TWO POINTS OF CORROSION EVIDENCE.(<P>RH WING, SLAT #7, WAS REPLACED IAW AMM 27-81-01-024-001 AND AMM 27-81- 01-424-143. OPS CHECK GOOD</P>)
Part: DISPLAY — INOPERATIVE (ZONE 200) · airframe 83,283 hrs · 16,423 cycles
FLIGHT MANAGEMENT COMPUTER SYSTEM, ASSY-FLIGHT PANEL P9, MCDU RIGHT SIDE INOPERATIVE(<P>MCDU RIGHT WAS REPLACED IAW AMM 34-61-02-400-802. OPS CHECK GOOD</P>)
Part: FRAME — CORRODED (ZONE 100) · corrosion level 2 · airframe 83,283 hrs · 16,423 cycles
FWD CARGO COMPARTMENT, EVIDENCE OF CORROSION ON WEB FRAME AT BS 764 BTW S37L AND S38L.(<P>WEB FRAME AT BS 764 BTW S37L AND S38L. PAINT WAS REMOVED, REWORKED, INSPECTED AND ALLOWABLE LIMITS FOUND. ALLODINE, PRIMER AND PAINT WAS RESTORED IAW SRM 53-00-07-1A-1. NO FURTHER DEFECTS NOTED</P>)
Part: FUEL CELL — LEAKING (ZONE 600) · airframe 83,283 hrs · 16,423 cycles
RH WING, FUEL LEAK ON LOWER SKIN AND SPLICE BTW WBL 97.95. TO WS 226.3 AND BTW STGR L7 TO L15(<P>FUEL LEAK WAS REPAIRED AND LEAK TEST WAS SATISFACTORY IAW AMM 28-11-00-308-013</P>)
Part: FIRE SEAL — DAMAGED (THRUST REVERSER) · airframe 83,283 hrs · 16,423 cycles
ENG 2, LEFT T/R DOOR, UPPER SECTION, FIRE SEAL, RESTORE SEALANT (THE ENTIRE PERIPHERY)(<P>FIRE SEAL WAS REPAIRED IAW AMM 78-00-00-038-001-N00. NO FURTHER DEFECTS NOTED</P>)
Part: SKIN — CRACKED (ZONE 200) · airframe 83,283 hrs · 16,423 cycles
DOUBLER INSTALLED ON EMERGENCY LIGHT OF THE MCD SURROUND SKIN CIRCUMFERENTIAL SPLICE STA 654+22 AT AFT FASTENER ROW IN THE SECOND LOWER FASTENER HOLE WITH CRACK INDICATION.(<P>THE SECOND LOWER FASTENER HOLE WAS ENLARGE UP TO SECOND OVERSIZE AND WAS REPAIRED IAW FVCI #24153-1, FAA FORM 8110-3 WAS ISSUED. NO FURTHER DEFECTS NOTED</P>)
Part: BULKHEAD — CORRODED (ZONE 100) · airframe 83,283 hrs · 16,423 cycles
BULK CARGO COMPARTMENT, AFT BULKHEAD, BTW STA 1540 AND STA 1581, S-38L WITH EVIDENCE OF CORROSION.(<P>BULK CARGO COMPARTMENT, AFT BULKHEAD, BTW STA 1540 AND STA 1581, S-38L WAS REPAIRED IAW SRM 53-00-03-2R-2</P>)
Part: ACTUATOR — LEAKING (ZONE 500) · airframe 83,283 hrs · 16,423 cycles
LH WING, LATERAL CENTRAL CONTROL ACTUATORS UPPER AND LOWER (M274 AND M276) LCCA WITH HYDRAULIC LEAK.(<P>LH WING, LATERAL CENTRAL CONTROL ACTUATORS UPPER AND LOWER (M274 AND M276) LCCA LEAK CHECK WAS PERFORMED, NO LEAKS WERE FOUND</P>)
Part: ACCESS PANEL — PUNCTURED (ZONE 100) · airframe 83,283 hrs · 16,423 cycles
SYS LH HYD BAY, (ACCESS PANEL 437BL), SURFACE INERSIDE AREA LOWER RIGH TSIDE, ANGLE WITH PUNCTURE.(<P>SURFACE INERSIDE AREA LOWER RIGHTSIDE, ANGLE WAS REPAIRED IAW TRE 6754195 ISSUED DATE 13/SEP/24 & CMA-TLS-24-0190, RDR WAS ISSUED. NO FURTHER DEFECTS NOTED</P>)
Part: SKIN — CRACKED (ZONE 100) · airframe 83,283 hrs · 16,423 cycles
AT FWD SERVICE DOOR CUTOUT AFT LOWER CORNER TWO HOLES WITH CRACK INDICATION ON FUSELAGE SKIN APPROX 10 OôCLOCK.(<P>AT FWD SERVICE DOOR CUTOUT AFT LOWER CORNER ON FUSELAGE SKIN APPROX 10 OôCLOCK DAMAGES WERE REPAIRED IAW FVCI #24153-2 A FAA FORM 8110-3 (09/20) WAS ISSUED. NO FURTHER DEFECTS NOTED</P>)
Part: BULKHEAD — CORRODED (ZONE 100) · airframe 83,283 hrs · 16,423 cycles
BULK CARGO COMPARTMENT, AFT BULKHEAD, BTW STA 1540 AND STA 1581, S-38R WITH EVIDENCE OF CORROSION.(<P>BULK CARGO COMPARTMENT, AFT BULKHEAD, BTW STA 1540 AND STA 1581, S-38R WAS REPAIRED IAW SRM 53-00-03-2R-2. NO FURTHER DEFECTS NOTED</P>)
Part: SEAL — WORN (ZONE 500) · airframe 83,283 hrs · 16,423 cycles
LEFT WING, OUTBD WING TIP, ANTI-COLLISION LIGHT WITH WORN SEAL(<P>THE WORN SEAL ON LEFT WING, OUTBD WING TIP, ANTI-COLLISION LIGHT WAS REPLACED IAW AMM 33-44-01-002-017. NO FURTHER DEFECTS NOTED</P>)
Part: FILL PORT — CORRODED (ZONE 600) · airframe 83,283 hrs · 16,423 cycles
RH WING, UPPER SURFACE, BASE OF OVERWING FILL PORT ADAPTER WITH EVIDENCE OF CORROSION(<P>OVERWING FILL PORT ADAPTER. CORROSION LEVE 1 WAS REWORKED, INSPECTED AND ALLOWABLE LIMITS FOUND IAW SRM 57-20-01-1A-1</P>)
Part: PDU — LEAKING (ZONE 600) · airframe 83,283 hrs · 16,423 cycles
RIGHT WING, SLAT PDU INBOARD, WITH EVIDENCE OF HYD LEAK(<P>RIGHT WING, SLAT PDU INBOARD WERE REPLACED IAW AMM 27-81-10-424-023 AND AMM 27-81-10-024-001, LEAK CHECK WERE PERFORMED, NO LEAK WAS FOUND.</P>)
Part: RVDT — OUT OF RIG (LE FLAP SYS) · airframe 83,160 hrs · 16,374 cycles
CLIMBING OUT OF RFD, WE WENT FLAPS UP AND THEN GOT LE SLAT DISAGREE MSG. PERFORMED FSEU BITE CHECK IAW FIM 27-51 FT 809. FOUND FAULT CODE 27-S1040 FOR LVR 1 NOT IN DETENT, CHECKED RIGGING OF FLAP LEVER RVDT IAW AMM 27-51-26. FOUND RVDT 1 OUT OF LIMITS IN UP POSITION, ADJUSTED RVDT IAW AMM 27-51-26. OPS CHECK GOOD AT THIS TIME.
Part: HARNESS — MALFUNCTIONED (CABIN) · airframe 82,931 hrs · 16,284 cycles
THREE ESCAPE HARNESSES INOP. INSTALLED SAFETY HARNESS IAW AMM 25-61-05. MCC NOTIFIED, PLACARDS REMOVED. THIS CLOSES DMI #211594.</P>)
Part: ELEVATOR SYSTEM — NONE · airframe 82,914 hrs · 16,277 cycles
CAN'T GET FULL TRAVEL WITH FWD ELEVATOR(<P>PERFORMED OPS CHECK OF ELEVATOR POSITION INDICATION SYSTEM IAW AMM 27-38-00. VERIFIED ALL INDICATIONS WITHIN LIMITS. AC OKAY FOR SERVICE.</P>)
Part: SENSOR — FAULTED (AFT CARGO DOOR) · airframe 82,667 hrs · 16,178 cycles
"AFT CARGO DOOR" EICAS MESSAGE CLIMBING THROUGH FL210 (APPROX)(<P>RE-OPENED DMI 208833 PER MEL 52-27-01-01 CAT C DUE DATE 26MAY24. MCC NOTIFIED. PLACARDS INSTALLED. C/W MX PROCEDURES. RE-INSPECTED PRIOR TO EACH DEPARTURE.</P> / <P>LP 1813181 P1: REPLACED S208 AFT CARGO DOOR SENSOR IAW AMM 52-71-01. VERIFIED S208 INDUCTANCE WITH LCR METTER IS GOOD IAW AMM 32-09-13. PRESSURIZED A/C IAW AMM 05-51-24 TO 4 PSI. NO INDICATIONS NOTED AT THIS TIME. THIS CLEARS DMI 208833.</P>)
2023
Part: RADOME — UNKNOWN (UNKNOWN) · airframe 81,735 hrs · 15,822 cycles
NOSE RADOME HAS MULTIPLE SMALL PUNCTURE DAMAGES AND DELAMINATION DUE TO FOD.(<P>ACFT AOG FOR NEW RADOME. R/R RADOME IAW AMM 53-12-01. NO FURTHER DEFECTS NOTED</P>)
Part: TRANSDUCER — UNKNOWN (UNKNOWN) · airframe 81,088 hrs · 15,618 cycles
INFLIGHT ANTISKID EICAS MESSAGE AND OVERHEAD LIGHT ILLUMINATED(<P>PERFORMED FIM TASK 32-42 FT 803. FOUND WHEEL SPEED TRANSDUCER FAULTY. REMOVED AND REPLACED WHEEL SPEED TRANSDUCER IAW AMM 32-42-06. OPS CHK GOOD</P>)
Part: RELIEF VALVE — UNKNOWN (UNKNOWN) · airframe 81,069 hrs · 15,611 cycles
WAS ADVISED BY TOWER WE HAD A L WING FUEL LEAK. CONFIRMED WE WERE LOSING FUEL AND LANDED BACK IN ONT. ON DESCENT L PRESS RELIEF VALVE LEAKING.(<P>PRESS RELIEF VALVE UNABLE TO RESET. R/R PRESS RELIEF VALVE IAW AMM 28-13-04. TRANSFERRED FUEL AND PERFORMED ENGINE RUN IAW AMM 77-00-00. OPS CHECK AND LEAK CHECK GOOD. PART EFFECTIVITY IAW IPC 28-11-01-02</P>)
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 81,013 hrs · 15,593 cycles
A/T DISC EICAS MESSAGE WITH MASTER CAUTION ON T/O ROLL. REJECTED TAKEOFF AT LOW SPEED(<P>PERFORMED LOW SPEED REJECTED T/O INSPECTION IAW B767-300 AMM 05-51-14-212. NO DAMAGE NOTED AT THIS TIME</P>)
Part: VALVE — UNKNOWN (UNKNOWN) · airframe 80,340 hrs · 15,360 cycles
LH WING, SURGE TANK PRESSURE RELIEF VALVE, PRESSURE RELIEF VALUES OUT OF LIMITS(<P>LH WING SURGE TANK PRESSURE&NBSP;RELIEF VALVE WAS REPLACED IAW AMM 28-13-04-402-006</P>)
Part: BUSHING — UNKNOWN (UNKNOWN) · airframe 80,340 hrs · 15,360 cycles
RH MAIN LANDING GEAR. REAR SPARE HOUSING BORE BUSHINGS WITH CORROSION.(<P>REAR SPARE HOUSING BORE BUSHINGS WERE REPLACED ON RH MAIN LANDING GEAR IAW CMM 57-54-13, REPAIR 2-1</P>)
Part: SMOKE DETECTOR — UNKNOWN (UNKNOWN) · airframe 80,340 hrs · 15,360 cycles
FWD CARGO SMOKE DETECTOR SYSTEM, SMOKE DETECTOR M2030 AND M2028 WITH HOSE TORN.(<P>FWD CARGO SMOKE DETECTOR SYSTEM, SMOKE DETECTOR HOSE WAS REPLACED I.A.W AMM 26-16-01-400-801-001 REV 138. 22 DEC 2022</P>)
Part: HOSE — UNKNOWN (UNKNOWN) · airframe 80,340 hrs · 15,360 cycles
MAIN CARGO DECK AREA, BETWEEN BS 500 AND STRINGER 5 LH WITH FIRE DETECTOR HOSE BROKEN(<P>MAIN CARGO DECK AREA, BETWEEN BS 500 AND STRINGER 5 LH FIRE DETECTOR HOSE WAS REPLACED AND TEST WAS SATISFACTORY, I.A.W. AMM 26-16-01-400-801-001 REV 138 - 22 DEC 2022</P>)
Part: VALVE — UNKNOWN (UNKNOWN) · airframe 80,340 hrs · 15,360 cycles
ENGINE #1, BLEED AIR PRECOOLER (PRSOV) BROKEN.(<P>PRESSURE REGULATOR AND SHUTOFF VALVE (PRSOV) WAS REPLACED PER AMM 36-11-09-402-162-008 REQUIREMENTS</P>)
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 80,340 hrs · 15,360 cycles
ENGINE 2, MAIN GEARBOX WITH CHAFING BETWEEN 5 & 6 O' CLOCK(<P>ENGINE #2 MAIN GEARBOX HOUSING DAMAGES WERE REPAIRED, IAW PW CIR 72-61-10, INSPECTION CHECK 03 AND SPM 70-45-00 SPOP-533</P>)
Part: SMOKE DETECTOR — UNKNOWN (UNKNOWN) · airframe 80,340 hrs · 15,360 cycles
AFT CARGO SMOKE DETECTOR SYSTEM, SMOKE DETECTOR M9803 WITH HOSE TORN.(<P>AFT CARGO SMOKE DETECTOR SYSTEM, SMOKE DETECTOR HOSE WERE RAPLACED I.A.W AMM 26-16-01-400-801-001 REV 138. 22 DEC 2022&NBSP;</P>)
Part: BRAKE — UNKNOWN (UNKNOWN) · airframe 80,340 hrs · 15,360 cycles
MAIN LANDING GEAR, BRAKE #4 WITH LEAK(<P>MAIN LANDING GEAR, BRAKE #4 WAS REPLACED I.A.W AMM 32-41-08-404-017-002 REQUIREMENTS</P>)
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 80,340 hrs · 15,360 cycles
LH WING, SLAT #1 SURFACE INNER, UPPER WITH EVIDENCE OF CORROSION.(<P>SLAT #1 SURFACE INNER, UPPER WAS REPAIRED IAW SRM 57-43-02-2R-1 REPAIR 1 FIG 201 SHEET 2-3 PAGE 1-3 AND SRM 51-70-10-2R-4 REP 4. REV 121 DEC15/2022&NBSP;</P>)
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 80,340 hrs · 15,360 cycles
RIGHT LOWER WING SURFACE ZONE 194, FUEL LEAK ON WING STRINGER #6 FROM BBL 62.0 TO 97.42(<P><SPAN>FUEL LEAK WAS REPAIRED ON WING&NBSP;</SPAN><SPAN>STRINGER #6 FROM BBL 62.0 TO 97.42. AND&NBSP;</SPAN><SPAN>FUEL LEAK TEST WAS SATISFACTORY</SPAN></P>)
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 80,340 hrs · 15,360 cycles
LEFT LOWER WING SURFACE ZONE 193, FUEL LEAK ON WING STRINGER SPLICE #6 AND WING STG #10 AT BBL 97.42.(<P>FUEL LEAK WAS REPAIRED ON WING STRINGER SPLICE #6 AND WING STG #10 AT BBL 97.42 PER AMM 28-11-00-308-013 REQUIREMENTS</P>)
Part: VALVE — UNKNOWN (UNKNOWN) · airframe 80,340 hrs · 15,360 cycles
RH WING, SURGE TANK PRESSURE RELIEF VALVE, PRESSURE RELIEF VALUES OUT OF LIMITS(<P>RH WING, SURGE TANK PRESSURE RELIEF VALVE WAS REPLACED IAW AMM 28-11-03-404-011 REQUIREMENTS</P>)
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 80,340 hrs · 15,360 cycles
DERIVED FROM EO 6734A200, ELECTRICAL WIRES ARE NOT INSTALLED ON CONNECTORS D4717J/P AND D4711J/P IAW WIRE DIAGRAM 34-53-11 AND 34-53-21. "STC ST02126LA"(<P>THE ELECTRICAL WIRES W9133-9903R/9904B-22 AND WAAS-9004-22R/WASS-9005-22B WERE RELOCATED TO CONNECTOR D4717P/J, THE ELECTICAL WIRES W9145-9903R/9904B-22 AND WAAS-9204-22R/WAAS-9205-22B WERE RELOCATED TO CONNECTOR D4711P/J AND THE WIRES W9133-9903R/9904B-22 AND W9145-9903R/9904B-22 WERE RENAMED. I.A.W. EA 6734A0007 REV 0 DATE 15 MAR 2023</P>)
Part: PROCESSING UNIT — FAILED (TOTALIZER) · airframe 80,063 hrs · 15,259 cycles
RIGHT WING AND TOTALIZER READINGS WENT BLANK DURING CRUISE. TRANSFERRED TO MDDR 178181 IAW MEL 28-41-01-01 CAT C DUE DATE 15JAN23. MX ACTIONS C/W. REMOVED AND REPLACED (FQIS) PROCESSOR IAW B767 AMM 28-41-08. OPS CHECKED GOOD. NO DEFECTS NOTED. THIS CLOSES DMI 178181. PLACARDS REMOVED. MCC NOTIFIED&NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP; &NBSP;&NBSP;</P>)
2022
Part: BATTERY — INOPERATIVE · airframe 79,650 hrs · 15,102 cycles
EMERGENCY OVERHEAD LIGHTING RH SIDE INOP ( INTERIOR EMERGENCY LIGHTING SYSTEM (BATTERY POWERED)(<P>REMOVED AND REPLACED AFT EMERGENCY LIGHTING BATTERY IAW AMM 33-51-07 OPS CHECK GOOD.</P>)
Part: MASK — INOPERATIVE · airframe 78,899 hrs
CAPT O2 MASK NOT WORKING PROPERLY, HARD TO BREATH THROUGH. NEEDS TO BE REPLACED. R/R CAPT O2 MASK IAW AMM 767 BOEING 35-11-51. OPS CHECK GOOD
Part: LENS — LOOSE · airframe 78,645 hrs
EXIT LIGHT LENS ADJACENT TO L1 DOOR FELL OFF(<P><SPAN>REMOVED AND REINSTALLED LIGHT LENS EXIT IAW AMM 33-51-01</SPAN></P>)
Part: LENS — LOOSE · airframe 78,645 hrs · 14,767 cycles
REATTACH EXIT LIGHT LENS ADJACENT TO L1 DOOR(<P>REINSTALLED&NBSP; EMERGENCY DOOR EXIT COVER IAW AMM 33-51-01</P>)
Part: SIGN — UNSECURE · airframe 78,394 hrs
EXIT SIGN BY MAIN ENTRY DOOR FELL OFF.(<P>RESECURED EXIT SIGN BY MAIN ENTRY DOOR IAW AMM 33-51-01. COVER WAS FOUND IN GOOD CONDITION. OPS CK GOOD.</P>)
Part: MASK — INOPERATIVE · airframe 78,357 hrs
SUPERNUMERARY SEAT 1 OXYGEN MASK INOP. THIS BECOMES MDDR# 161903 PER MEL 35-11-03-02A, CAT C, DUE 09MAR22. LOG 1439548 ITEM# 7: REMOVED AND REPLACED SEAT 1 SUPERNUMERARY OXYGEN MASK ASSY IAW AMM 35-11-51. OPS CHECK NORMAL. CLEARED MDDR 161903, PLACARD REMOVED.
Part: NONE — NONE · airframe 78,080 hrs · 14,584 cycles
# 2 ENGINE PYLON FWD TOP PANEL SHOWS FASTENERS MISSING .(<P>LOCATED AND INSTALLED NEW FASTENERS&NBSP; AT&NBSP; #2&NBSP; ENG&NBSP; PYLON FWD TOP ACCESS PANEL PER&NBSP; B767-300</P> / <P>AMM 20-11-00-910-802 .</P>)
Part: CONNECTOR — NONE · airframe 78,080 hrs · 14,584 cycles
# 1 ENG. LWR EXCITER CANNON PLUG DAMAGED(<P>REPLACED # 1 ENG LWR EXCITER CONNECTOR D10978 PER W/D 74-31-11&NBSP; & SWPM 20-61-00</P> / <P>ENG IGN SYS AUDIBLE TEST OK&NBSP;</P> / <P>AMM 74-00-00/705.</P>)
Part: NONE — NONE · airframe 78,080 hrs · 14,584 cycles
# 2 ENGINE CORE COWLS I/B AND O/B FWD EDGE SHOWS SEVERAL AREAS OF ABLATIVE COATING DETERIORATED .(<P>PREPARED CLEANED AND&NBSP; REPAIRED&NBSP; AREAS&NBSP; OF&NBSP; #2&NBSP; ENG&NBSP; CORE COWLS&NBSP; I/B&NBSP; &&NBSP; O/B&NBSP; &NBSP;FWD&NBSP; EDGE&NBSP; PER&NBSP; B767-300</P> / <P>AMM&NBSP; &NBSP; 78-31-01-350-802-N00</P>)
Part: PLACARD — NONE · airframe 78,080 hrs · 14,584 cycles
ENGINE # 1 FAN COWL INB/OUT WITH PLACARDS DAMAGED AT INTERNAL AREA .(<P>REMOVED AND REPLACED DAMAGED PLACARD&NBSP; AT # 1 ENG.&NBSP; FAN COWL&NBSP; I/B&NBSP; & O/B&NBSP; INNER AREA&NBSP; PER&NBSP; B767-300 AMM 10-14-004-016&NBSP; &&NBSP; AMM 20-10-14-404-005..</P>)
Part: PLUG — NONE · airframe 78,080 hrs · 14,584 cycles
ENG. # 1 DURING REMOTION PLUG AP-3 FOR BORESCOPE WAS DAMAGED(<P><SPAN>REMOVED & REPLACED&NBSP; ENG 01&NBSP; AP-3&NBSP; BORESCOPE&NBSP; PLUG PER AMM 72-00-00</SPAN></P>)
Part: BLANKET — NONE · airframe 78,080 hrs · 14,584 cycles
# 2 ENGINE HYD. LINES ISOLATION BLANKET FOUND DAMAGED .(<P>REMOVED AND REPLACE # 2 ENGINE&NBSP; HYDRAULIC HOSES ISOLATION BLANKET IAW AMM 70-00-00/ 29-11-05.</P>)
Part: NONE — NONE · airframe 78,080 hrs · 14,584 cycles
# 2 ENGINE O/B STRUT DOOR OPEN HOLD ROD AND SUPPORT ASSY FOUND DAMAGED .(<P>FOUND SUPPORT AND&NBSP; HOLD ROD LOOSE RESECURED ALL PART AT #2 ENG O/B STRUT DOOR PER B767-300</P> / <P>AMM&NBSP; 20-11-00-910-802 .</P>)
Part: NONE — NONE · airframe 78,080 hrs · 14,584 cycles
# 2 ENGINE PYLON AFT FAIRING PANEL SHOWS SEVERAL FASTENERS MISSING .(<P>LOCATED AND INSTALLED NEW FASTENERS AT #2&NBSP; ENG PYLON AFT FAIRING PANEL PER&NBSP; B767-300&NBSP;&NBSP;</P> / <P>AMM&NBSP; &NBSP;20-11-00-910-802</P>)
Part: MODULE — NONE · airframe 78,080 hrs · 14,584 cycles
MESSAGE : FLAP/SLAT ELECT.(<P>T/S F/M 27-58-02; FSPM&NBSP; M840/850 BITE TEST INOP.</P> / <P>T/S W/D&NBSP; SSM&NBSP; 27-58-02.</P> / <P>REMOVED & REPLACED MODULE F/S&NBSP; POSITION&NBSP; RH&NBSP; &NBSP;M840&NBSP; &&NBSP; OPS&NBSP; CHECK&NBSP; OK AMM 27-58-01/904</P>)
Part: NONE — NONE · airframe 78,080 hrs · 14,584 cycles
RH PACK HI FLOW INHIBIT .(<P>T/S FIM 21-51- TASK 875 & W/D 21-51--21</P> / <P>RH FLOW CONTROL CARD M864 FAULT&NBSP;</P> / <P>&NBSP;</P> / <P>REMOVED CLEANED UP & INSTALLED FLOW CTL CARD M864 & OPS CHECK RH A/C PACK . SYS OK PER AMM 21-51-00/808</P>)
Part: NONE — NONE · airframe 78,080 hrs · 14,584 cycles
ENG # 1 OUTBOARD C/DUCT LOWER SUPPORT WITH BOLT & ANCHOR NUT MISSING BEHIND OF LOWER ACTUATOR OF REVERSE.(<P>LOCATED AND INSTALLED NEW&NBSP; FASTENER AT #1 ENG O/B C/DUCT LOWER SUPPORT PER B767-300</P> / <P>AMM 20-11-00-910-802</P>)
Part: NONE — NONE · airframe 78,080 hrs · 14,584 cycles
# 2 ENGINE FAN ROTOR BLANDES FOUND A BLADES BENT AT L/E AREA C.(<P>FOUND BENT WITHIN LIMITS PER&NBSP; B767-300 AMM 72-31-02-206-070-N00&NBSP; DIMENSION IS .125" X 105" INCHES</P> / <P>PERFORMED NDT SPOT FLOURESCENT AND EDDY CURRENT INSPECTION ON LE&NBSP;&NBSP;</P> / <P>NO CRACK INDICATION NOTED REF AMM 70-11-06.</P>)
Part: PLACARD — NONE · airframe 78,080 hrs · 14,584 cycles
COCKPIT WINDOWS CAPTAIN AND FO PLACARD WINDOWS NOT CLOSED DAMAGED .(<P>REMOVED AND REPLACED DAMAGED PLACARD AT COCKPIT WINDOWS CAPT. & FO&NBSP; SIDE PER&NBSP; B767-300</P> / <P>AMM 20-10-13-964-001</P>)
2021
Part: TERMINAL — DAMAGED (FIRE LOOP) · airframe 77,739 hrs
RIGHT ENGINE FIRE LOOP 1 INOP ( ENGINE FIRE DETECTION SYSTEMS, DETECTION LOOPS (ER RESTRICTED 120) )(<P>TRANSFERRED TO MDDR 156745 PER DDG MEL 26-11-01-01 CAT C DUE 23NOV21.</P> / <P>16NOV21 - LP 1429842 - ITEM #1 - PDX - REMOVED AND REPLACED TERMINAL A1 AT DETECTOR TS56B1 WIRE # W3506-452A-16 IAW SWPM 20-30-11. OPS CHECK GOOD AT THIS TIME. NO STATUS MSG PRESENT. THIS CLEARS DMI # 156745, PLACARD REMOVED.</P>)
Part: WARNING MESSAGE — FALSE ACTIVATION (RT ENG FIRE LOOP)
STATUS R ENG FIRE LOOP 1(<P>PERFORMED OPS CHECK PER AMM 26-11-01, OPS CHECK GOOD.
Part: NONE — NONE · airframe 77,728 hrs
APU COLD SOAK START: FL370, OAT-54. 1ST ATTEMPT NO EGT, 26% UNSUCCESSFUL. 2ND ATTEMPT NO EGT, 27% UNSUCCESSFUL, 3RD ATTEMPT NO EGT, 27% UNSUCCESSFUL.(<P>INFO NOTED, REF THIS LOG BLOCK 2. THIS CLOSES MDDR 156399.</P> / <P>ITEM 2: APU INOP DUE TO SEVERAL COLD SOAK START ATTEMPTS. TRANSFER TO DMI 156461 IAW MEL 49-11-01A, CAT C.</P> / <P>12NOV21 - 1429835 - ITEM # 6 - PDX - REMOVED AND REPLACED APU IGNITION UNIT IAW B767 AMM 49-41-03 OPS CHECK GOOD, NO FAULTS NOTED.</P> / <P>12NOV21 - 1429836 - ITEM# 9 - PDX - DUE TO SUCCESSFUL GROUND START OF APU IAW B767 AMM 49-41-02. THIS CLEARS DMI 156461. PLACARDS REMOVED</P>)
Part: NONE — NONE
APU REALIBILTY COLD START: FLT LEG CVG-SCK, 51C, FL 360. 3 ATTEMPTS, UNSUCCESFUL. APU FAULT @ 30RPM.(<P>NOTED BY MX. MCC NOTIFIED. MDDR # 156399 REMAINS OPEN.</P> / <P>REF LP 1466236: APU COLD SOAK START, FL370, OAT-54. 1ST ATTEMPT NO EGT 26% UNSUCCESSFUL. 2ND ATTEMPT NO EGT 27% UNSUCCESSFUL, 3RD ATTEMPT NO EGT 27% UNSUCCESSFUL. INFO NOTED. THIS CLOSES MDDR 156399.</P>)
Part: CIRCUIT CARD — FAULTED (FIRE DETECTION)
R ENG FIRE LP 1(<P>TRANSFERRED TO MDDR 156392 IAW MEL 26-11-01-01, C/W MAINTENANCE PROCEDURE</P> / <P>REMOVED AND REPLACED FIRE LOOP 1 CARD REF AMM 26-10-01. PERF OPS OF R ENG FIRE LOOPS. FOUND UPPER FIRE LOOP AFT BRACKET NOT SECURED ,SECURED IAW 20-11-00. OPS CHECK NORMAL.THIS CLEARS DMI 156392 T & I 0339Z TS</P> / <P>&NBSP;</P>)
Part: STATUS MESSAGE — FALSE ACTIVATION (RT ENG FIRE LOOP)
R ENG FIRE LOOP 1 STATUS MESSAGE DISPLAYED AFTER LANDING(<P><SPAN>PERFORMED [POWER SHUTDOWN AND ENGINE FIRE DECTECTION TEST OPS CHECK GOOD AT THIS TIME. IAW AMM 26-11-00.755-011</SPAN></P>)
Part: NONE — NONE
APU RELIABILITY COLD COLD START UNSUCCESSFUL. ATTEMPTED 3 STARTS. ALL THREE ATTEMPTS LED TO APU FAULT EICAS(<P>TRANSFERRED TO MDDR #156348 IAW MEL 49-11-01A</P> / <P>LOG PAGE 1466231: PERFORMED APU CONTROL UNIT BITE CHECK IAW B767 AMM 49-61-05, NO FAULTS FOUND AT THIS TIME. THIS CLEARS DMI 156348.</P>)
Part: FIRE LOOP — FALSE ACTIVATION (RT ENGINE) · 14,438 cycles
R ENG FIRE LP 1 STATUS MESSAGE. TESTED R/ENG FIRE LOOP 1 IAW B767 FIM26-11 FAULT TREE 806 SYSTEM TEST OK NO FUTHER ACTION REQUIRED.
Part: TRANSFORMER — NONE
APU INOP / ( AUXILIARY POWER UNIT (APU), ER OPERATIONS NOT ALLOWED (NOTIFY DISPATCH) R60 )(<P>&NBSP;</P> / <P>REMOVED AND REPLACE APU TRANSFORMER RECTIFIER IAW 24-32-04, OPS CK GOOD.TRANSFERRED TO MDDR 156214 IAW MEL 49-11-01A CAT C DUE DATE: 14NOV21</P>)
Part: NONE — NONE
APU COLD RELIABILITY START CVG-ONT , SAT-52 DEGREES C , FL360, 3 START ATTEMPTS WERE MADE, ALL UNSUCCESSFUL. NO EGT WAS INDICATED (REMAINED AT 0) MAX RPM 25.(<P><SPAN>PERFORMED APU BITE IAW FIM 49-11 F/T 9J8. NO FAULTS NOTED, PERFORMED MULTIPULE STARTS OF APU IAW AMM 49-11-00. ALL OPS CHECK GOOD. NO DEFECTS NOTED</SPAN></P>)
Part: NONE — NONE
RECIEVED APU BAT DISCH EICAS MESSAGE AFTER 3RD ATTEMPT OF APU RELIABILITY COLD START MESSAGE DISAPPEARED AFTER 10 SECONDS(<P>REF LOG 1422645 ITEM 2 - PERFORMED APU BITE IAW FIM 49-11 F/T 9J8. NO FAULTS NOTED, PERFORMED MULTIPULE STARTS OF APU IAW AMM 49-11-00. ALL OPS CHECK GOOD. NO DEFECTS NOTED.</P>)
Part: NONE — NONE
RIGHT GENERATOR DISC DRIVE LIGHT ILLUMINATED(<P>TRANSFERRED TO MDDR #155130 IAW DDG 24-00-00-02, CAT B.</P> / <P>LOG PAGE 1422602: PERF RT ENG IDG BITE TEST & RESET PER AMM 24-11-00. NO FAULTS NOTED. PERF R ENG IDLE RUN FULL LOAD ON RIGHT IDG. POWER STABLE NO MSG OR DISCONNECT PER AMM 72-00-00. THIS CLEARS MDDR 155130.</P>)
Part: FIRE WARNING — FALSE ACTIVATION (RT ENGINE)
STATUS MSG R ENGINE LP 1(<P><SPAN>PERF ENG/APU FIRE TEST PER AMM 26-11-01. SYSTEM OPERATING NORMAL.</SPAN></P>)
Part: FIRE WARNING — FALSE ACTIVATION (APU BAY)
STATUS MSG APU FIRE LP 1(<P>PERF ENG/APU FIRE TEST PER AMM 26-11-01. VERFIED STATUS MSG EXTINGUISHED. SYSTEM OPERATIING NORMAL.
Part: CONTROL CARD — WARNING LIGHT · airframe 77,333 hrs · 14,326 cycles
LT ENGINE HPSOV EICAS MSG.(<P>REMOVED AND RE-INSTALLED LEFT ENGINE BLEED AIR CONTROL CARD IAW AMM 36-11-12. MSG CLEARED. OPS CHECK GOOD.</P>)
Part: SKIN — DELAMINATED (LT WING TE) · airframe 77,138 hrs · 14,272 cycles
DELAMINATION ON LH WING FIXED TRAILING EDGE UPPER SKIN PANEL (113T1653) BETWEEN WSTA 554.5 / WSTA 605.5(<P ><SPAN>DELAMINATED AREA WAS REPAIRED BY SRM</SPAN></P> / <P>&NBSP;</P>)
Part: TEE FITTING — CRACKED (NLG WW) · airframe 77,138 hrs · 14,272 cycles
CRACK ON NOSE WHEEL WELL BULKHEAD VERTICAL CHORD (TEE) AT STA 287, RBL 25(<P ><SPAN>REPAIR ANGLES WERE INSTALLED PER </SPAN>SRM 51-70-12-0G-0 / ATLAS EO 6753A027.</P>)
Part: PCA — LEAKING (RT ELEVATOR) · airframe 77,138 hrs · 14,272 cycles
PISTON OF RH ELEVATOR OUTBD PCA WITH HYDRAULIC LEAK(<P ><SPAN>IT WAS REPLACED THE RH ELEVATOR OUTBD PCA PER AMM </SPAN>27-31-05-024-027</P>)
Part: FUEL CELL — LEAKING (RT WING) · airframe 77,138 hrs · 14,272 cycles
FUEL LEAK ON RH WING LOWER SKIN AT STRINGER L-10 AND BETWEEN WSTA 197.4 / WBL 121(<P ><SPAN>FUEL LEAK WAS REPAIRED PER AMM&NBSP;</SPAN></P> / <P>&NBSP;</P>)
Part: PCA — LEAKING (LT ELEVATOR) · airframe 77,138 hrs · 14,272 cycles
LH ELEVATOR CENTER PCA WITH HYDRAULIC LEAK(<P ><SPAN>IT WAS REPLACED THE LH ELEVATOR CENTER PCA PER AMM&NBSP;</SPAN><SPAN>27-31-00-825.</SPAN></P> / <P>&NBSP;</P>)
Part: RADAR — MALFUNCTIONED (WX SYSTEM)
WX RADAR WAS NOT PAINTING WEATHER AT FL 370 AND 390(<P>PERFORMED OPERATIONAL TEST OF WEATHER RADAR SYSTEM IAW B767 AMM 34-43-00&NBSP; OPS CHECK GOOD&NBSP; ALSO PERFORMED SYSTEM TEST OF WEATHER RADAR SYSTEM IAW B767 AMM 34-43-00.&NBSP; SYSTEM TEST OKAY 2ND&NBSP; NO FAULTS OR DEFECTS NOTED</P>)
Part: OIL COOLER — LEAKING (APU)
SUSPECTED LEAK FROM APU OIL(<P>REMOVED AND REPLACED APU OIL COOLER IAW AMM 49-27-09. OPS CHECK GOOD.</P>)
Part: WARNING LIGHT — FALSE ACTIVATION · airframe 77,015 hrs · 14,238 cycles
DURING START RE (#2) AS GEN CAME ON LINE MOMENTARILY OVERSPEED EICAS ILLUM.(<P>PERF R ENG RUN PER AMM 72-00-00. AFTER GEN CAME ON DID NOT SEE ANY FAULTS IN VIEW. OPS CHECK GOOD.</P>)
Part: CIRCUIT CARD — MALFUNCTIONED (FIRE DETECTION)
RIGHT ENG FIRE LOOP 2 EICAS MSG.(<P>TRANSFERRED TO MDDR 149899 IAW MEL 26-11-01-01, CAT C.</P> / <P>REMOVED AND REPLACED #2 ENG FIRE LOOP #2 DETECTION CARD IAW ATLAS 767 AMM 26-10-01. OPS CHECK GOOD. THIS CLEARS MDDR #149899.</P>)
Part: CIRCUIT CARD — MALFUNCTIONED (NR 1 FIRE LOOP)
R ENG FIRE LP 1 EICAS MSG, PERFORMED GVI OF #2 ENGI. FIRE LOOP 1 NTF. T/S PER FIM B767 26-11 FAULT TREE 804. PERFORMED RESISTANCE CK WITHIN LIMITS PER TABLE B. REMOVED AND REPLACED ENGINE FIRE CONTROL CARD M683. IAW AMM 26-10-01 MSG CLEARED. P/N OFF - 898732-002, S/N OFF- 1283 - CARD</P> / <P>ITEM# 5 - DURING RIGHT ENGINE FIRE LOOP TROBLESHOOTING FOUND BROKEN PIN ON M684 CARD P/N 898732-02. PIN # 24. REMOVED AND REPLACED FIRE DETECT CARD M684 IAW AMM 26-10-01. OP'S CHECK GOOD.&NBSP;</P>)
Part: ECU — FAULTED (APU)
APU WILL NOT START(<P>T/S PER FIM 49-11 FAULT TREE&NBSP; 958 . FOUND ECU TO BE AT FAULT , REMOVED AND REPLACED APU ECU IAW AMM 49-61-05.OPS CKS GOOD , APU STARTED NORMAL.</P>)
Part: FIRE LOOP — FALSE INDICATION (LT ENGINE) · 14,219 cycles
LEFT ENG OVHT LOOP 1 EICAS MSG ( ENGINE OVERHEAT DETECTION SYSTEMS, DETECTION LOOPS (ER RESTRICTED 120) )(<P>TRANSFERRED TO MDDR 149523 PER MEL 26-11-02-07, CAT C, EXP 11JUL21. PLACARD INSTALLED.</P> / <P>LP 1122236: REMOVED AND REPLACED UPPER FWD LOOP DETECTOR IAW 767 AMM 26-11-02, OPS CHECK GOOD. THIS CLEARS MDDR 149523.</P>)
Part: ENGINE — NOT REPORTED (NR 1) · airframe 76,950 hrs · 14,219 cycles
#1 ENG REQ REPLACEMENT. R & R NR 1 ENGINE IAW J/C A71-999-02-01</P>)
Part: GUARD — BROKEN (LIGHT SWITCH) · airframe 76,915 hrs
EMERGENCY LIGHT SWITCH BROKE(<P>REMOVED AND REPLACED EMERGENCY LIGHT SWITCH COVER/GUARD PER AMM 33-51-08, OPS CHECK OK.</P>)
Part: FATS — MALFUNCTIONED (RIGHT) · airframe 76,860 hrs · 14,194 cycles
THE RIGHT FATS DOES NOT COMMAND THE FAV CLOSED. REMOVED AND REPLACED RH FATS PER AMM 36-101-17. NO LEAKS AND BITE TEST PASSED.
Part: OXYGEN MASK — DETERIORATED (COCKPIT) · airframe 76,860 hrs · 14,194 cycles
COCKPIT PORTABLE OXYGEN FULL FACE MASK HAS DETERIORATED RUBBER ON HOSE(<P>REMOVED AND REPLACED O2 FULL FACE MASK IAW AMM 35-31-01.</P>)
Part: DUCT — DETERIORATED (THRUST REVERSER) · airframe 76,860 hrs · 14,194 cycles
#1 ENGINE I/B T/R C-DUCT INNER FACE FOUND SEVERAL AREAS OF ABLATIVE COATING MISSING/DETERIORATED.(<P>PREPARED CLEANED AND REPAIRED DAMAGED FIRE RETARDANT ABLATIVE COATING AT #1 ENG I/B T/R C-DUCT INNER FACE PER B767-300 AMM 78-31-01-350-802-00.
Part: FASTENER — MISSING (FAIRING) · airframe 76,860 hrs · 41,494 cycles
NR 1 ENGINE-STRUT AFT FAIRING SHOWS SEVERAL FASTENERS MISSING. LOCATED AND INSTALLED NEW FASTENERS AT NR 1 ENG STRUT AFT FAIRING PER AMM 20-11-00-910-802.
Part: HEAT SHIELD — MISSING (NR 1 ENGINE) · airframe 76,860 hrs · 14,194 cycles
# 1 ENGINE LOWER IGNITION LEAD HEAT SHIELDS MISSING.(<P>INSTALLED HEAT SHIELDS ON #1 ENG LWR INGNITION LEAK PER AMM 74-21-01.</P>)
Part: PLATE — WORN (FAN COWL) · airframe 76,860 hrs · 14,194 cycles
2 ENG, FWD SUPPORT OF FAN COWL LH/RH IN NOSE COWL, HAS ELONGATED HOLE.(<P>REMOVED AND REPLACED DAMAGED PLATE AT #2 ENG FWD SUPPORT FAN COWL L/H AND R/H PER B767-300 AMM 20-11-00-910-802-.</P>)
Part: OXYGEN BOTTLE — LOW PRESSURE (CREW) · airframe 76,860 hrs · 14,194 cycles
FWD CARGO SUPERNUMERARY OXYGEN NEED SERVICE TO FULL. SERVICE FWD CARGO SUPERNEMERARY OXYGEN BOTTLE AS PER B767-300 AMM 12-15-08, AMM 35-00-00, AMM 35-11-00, AC 43-13-1B PER 9-46 THROUGH 9-51 PER 9-448 THROUGH 9-55. P/N 801307-00 S/N C17020688. NO LEAKS NOTED.
Part: SKIN — DENTED (NR 2 INLET) · airframe 76,860 hrs · 14,194 cycles
# 2 ENG. INLET COWL HAS A DENT AT LOWER NOSE LIP AREA(<P>FOUND DENT WITH IN LIMITS 1.5 MINOR AXY BY .050 DEPTH EQUAL 30 PWER B767-300 SRM 54-13-01-1A-1. PERFORMED NKT, HFEC INSPECTION OF THE DENT AREA. NO CHECK INDICATION NOTED REF NDTM PART 6 51-00-01.</P>)
Part: OXYGEN BOTTLE — LOW PRESSURE (CREW) · airframe 76,860 hrs · 14,194 cycles
FWD E & E CREW OXYGEN NEED SERVICE TO FULL. SERVICED CREW OXYGEN BOTTLE AS PER MM 12-15-08-608-801-001 AMM 35-00-00 AMM 35-11-00 AC 43-13-1B IAW 9-46 THOUGH 9-51 IAW 9-448 THOUGH 9-455 PN 1307-08. S/N 1507545 NO LEAKS.
Part: VALVE — FAULTED (RT ENGINE) · airframe 76,860 hrs · 14,194 cycles
THE RIGHT PRV DOES NOT CLOSE AT HIGH PRESSURE (PW 4000)(<P>REMOVED AND REPLACED RIGHT ENGINE PRESSURE REGULATING VALVE )PRV) IAW AMM 36-114-18, PENDING OPS CHECK. PERFORMED ENGINE RUN-UP, OPS CHECK NORMAL IAW AMM 36-11-18.</P><P><BR /></P>)
Part: OXYGEN BOTTLE — LOW PRESSURE (CREW) · airframe 76,860 hrs · 41,494 cycles
FWO CARGO SUPERNUMERARY OXYGEN NEED SERVICE TO FULL.(<P>SERVICE FWD CARGO SUPERNEMERARY OXYGEN BOTTLE AS PER B767-300 AMM 12-15-08, AMM 35-00-00, AMM 35-11-*00 AC 43-13-1B PER 9-46 THROUGH 9-51 PER 9-448 THROUGH 9-55&NBSP; P/N 801307-00 S/N C17020688 NO LEAKS NOTED.<BR /></P>)
Part: SIGNAL COND UNIT — FAILED (EFIS) · airframe 76,860 hrs · 14,194 cycles
L/HAND SIG GENERATOR OUT. ALT MODE(<P>REMOVED AND REPLACED LH EFIS S/G M148 PER AMM 34-22-01 REV 132.</P>)
Part: SCREW — LOOSE (SUPPLY DUCT) · airframe 76,860 hrs · 14,194 cycles
#2 ENG TURBINE COOLING, SUPPLY DUCT WITH SCREW LOOSE LOCATE AT 3 O'CLOCK POSITION.(<P>TIGHTENED LOOSE SCREW ON #2 ENG TURBINE COOLING SYPPLY DUCT PER AMM 70-50-00.</P>)
Part: SEAL — DETERIORATED (THRUST REVERSER) · airframe 76,860 hrs · 14,194 cycles
# 1 ENGINE O/B T/R C DUCT INNER FACE AIR VENT DUCT (METALIC SEAL) IS DETERIORATED(<P>REMOVED AND REPLACED SEAL @ #1 THRUST REVERSER OUTBOARD 'C' DUCT IAW 767 AMM 20-11-00 AND 78-31-01.<BR /></P>)
Part: OXYGEN MASK — DETERIORATED (COCKPIT) · airframe 76,860 hrs · 14,194 cycles
COCKPIT SUPERNUMERARY PORTABLE OXYGEN FULL FACE MASK HAS DETERIORATED RUBBER ON HOSE. REMOVED AND REPLACED O2 MASK @ SUPERNUMERARY PORTABLE BOTTLE IAW B767 AMM 35-31-01.
Part: SUPPORT — BROKEN (OXYGEN BOTTLE) · airframe 76,860 hrs · 14,194 cycles
FWD SUPPORT OF MAIN O2 CREW BOTTLE BROKEN.(<P>REMOVED AND REPLACED CREW OXYGEN BOTTLE HALF ASSY FRONT AS PER AMM 12-15-08.<BR /></P>)
Part: SWITCH — STUCK (LT RADAR) · airframe 76,570 hrs
L RADAR SWITCH JAMMED ON.(<P>RELEASED JAMMED L RADAR SW IAW 34-43-00. OPS CHECK GOOD.<BR /></P>)
Part: WARNING LIGHT — FALSE INDICATION (CARGO HEAT) · airframe 76,558 hrs · 14,102 cycles
EICAS MESSAGE AFT CARGO OVERHEAT. COMPLIED WITH QRH AND TURN SWITCH OFF LIGHT EXTINGUISHES 25 SEC LATER. OPS CHECK GOOD IAW AMM 21-40-00.
Part: UNKNOWN — UNKNOWN (APU) · airframe 76,522 hrs · 14,093 cycles
NO APU DUCT PRESSURE AFTER INITIAL APU START. APU SHUT DOWN AND RE-STARTED. APU BLEED VALVE SWITCH CYCLED, NO FAULTS NOTED. APU BLEED AIR OPS NORMAL AS PER AMM 49-00-00.
Part: WARNING MESSAGE — FALSE ACTIVATION (EXHAUST FAN) · airframe 76,507 hrs · 14,086 cycles
"AFT EQ EXH FAN 2" STATUS MSG AFTER BLOCK OUT(<P>PERFORMED T/S PER FIM 21-26 F/T 808, NO DEFECTS NOTED, MESSAGE CLEARED.</P>)
Part: FILTER — INDICATION (GENERATOR) · airframe 76,492 hrs · 14,080 cycles
APU FAILED TO START 3X. ECU: GEN FILTER.(<P>DEFERRED TO DMI 145827, MEL 49-11-01A, CAT C, DUE 04MAY21. MX ACTION NOR REQD. MX CNTL ANASTASIO. DISPATCH LC 1951, PLACARD APPLIED.</P><P>LP 1361523, ITEM M25: PERF APU BITE TEST IAW B767 AMM 49-61-05, "GENFAIL" FAULT LATCHED. T/S PER B767 FIM 49-11 FAULT TREE 969. CONFIRMED GEN OIL FILTER DP SWITCH(YBMS1) INSP. P/N OF DPSW: 3876048-3 NIS AT CVG. DMI 145827 REMAINS OPEN.</P><P>28 APR 21 - 1361536 - ITEM# 6 - SCK - R&R APU GENERATOR FILTER DIFFERENTIAL PRESSURE SWITCH IAW 49-27-15 OPERATIONAL CK NORMAL. THIS CLEARS DMI 145827 PER MCC GLEN.</P><P><BR DATA-MCE-BOGUS="1" /></P>)
Part: FILTER — FAILED (APU GENERATOR) · airframe 76,480 hrs · 14,075 cycles
CREW REPORTED APU WOULD NOT START AFTER 3 ATTEMPTS(<P>TRANSFERRED TO MDDR 145677, CAT C, DUE 1 MAY 2021 PER MEL 49-11-01A. PLACARDS APPLIED. DISPATCH RS 1641.</P><P>22 APR 21 - LP 1355446 ITEM 5 - SCK -&NBSP;REMOVED AND REPLACED APU GEN SCAVEGE FILTERS IAW AMM 49-27-03 OPS GOOD. THIS CLEARS MDDR 145677.</P>)
Part: APU — SHUTDOWN · airframe 76,484 hrs · 14,076 cycles
APU AUTO SHUTDOWN AFTER ENGINE SHUTDOWN UPON ARRIVAL(<P>OPS TESTED APU. OPS TEST GOOD. NO DEFECTS NOTED AT THIS TIME PER AMM 49-11-00.<BR /></P>)
Part: HOSE — LEAKING (HYD PUMP) · airframe 76,410 hrs · 14,051 cycles
FOUND EDP HYD LEAK ON OUTLET HOSE NEAR PYLON(<P>REMOVED & REPLACED EDP HYD PRESSURE UNIT IAW AMM 71-00-02. LEAK CHECK GOOD AT THIS TIME IAW AMM 29-11-00 & 71-00-00. NO LEAKS NOTED AT THIS TIME.<BR /></P>)
Part: ENGINE — CONTAMINATED (NR 1) · airframe 76,350 hrs · 14,031 cycles
DURING W/A FOUND ENG OIL IN THE INLET OF ENG #1(<P>NO OIL SERVICE REQUIRED. PERFORMED SYSTEM CLEANING. #1 ENG RUN UP BY FLIGHT CREW ASSISTANT FOR 5 MIN PER AMM 79-00-00. NO EVIDENCE OF LEAK DETECTED AFTER SHUTDOWN. ALL PARAMETERS NORMAL. AC OK FOR SERVICE. OIL QTY NORMAL.</P>)
Part: RELAY — MALFUNCTIONED (EXAHUST VALVE) · airframe 76,237 hrs · 13,988 cycles
BTB ON PUSHBACK AFTER ENG START FWD EQUP VLV EICAS MSG. RAN QRH LIGHT DID NOT EXT.(<P>TRANSFERRED TO DMI 143825 IAW MEL 21-58-07 PROCEDURE 2. PLACARDS INSTALLED. MCC NOTIFIED.&NBSP;</P><P>LP 1329081: PERFORMED FIM 21-58-58 FT 939. REMOVED AND REPLACED OVERBOARD EXHAUST VALVE INDICATION RELAY IAW SWPM 20-81-22. OPS CHECK GOOD. MCC NOTIFIED. THIS CLEARS DMI 143825. PLAC REMOVED.</P>)
Part: UNKNOWN — LEAKING (LT ENGINE) · airframe 76,261 hrs · 14,000 cycles
ON PREFLIGHT WALK AROUND DISCOVERED FLUID AT BOTTOM OF L ENG COWL FWD OF FAN.(<P>CLEANED FLUID FROM NBR 1 INLET. PERFORMED INSPECTION OF INTERNAL POWERPLANT IAW 71-05-03. NO LEAKS FOUND. NO FURTHER DEFECTS NOTED AT THIS TIME.</P>)
Part: CABLE — DAMAGED (NR 1 ENG IGNITER) · airframe 76,243 hrs · 13,992 cycles
LEFT ENGINE #2 IGNITION INOP ( IGNITION SYSTEMS, EXCEPT ER OPERATIONS (NOTIFY DISPATCH) (R60) )(<P>PARTS NOT TO BE RECEIVED IN TIME. ITEM TRANSFERED TO DMI# 143687 PER MEL 24-00-01B. CAT E. DUE DATE 21MAR21. P/N REQ: 10-609660-7. MCC NOTIFIED. NO MTX ACTION REQUIRED. PLACARDS INSTALLED.</P><P>LOGPAGE 1361677: REMOVED AND REPLACED #1 ENG LOWER EXCITER TO IGNITOR CABLE IAW B767 AMM 74-21-01. AUDIBLE TEST IAW B767 AMM 74-00-00 CK GD 1 & 2 POSITION.O&NBSP;</P>)
Part: BLADE — NICKED (LT ENG FAN) · airframe 76,226 hrs · 13,981 cycles
FOUND LH ENGINE NBR 8 FAN BLADE LEADING EDGE NICKED.(<P>BLENDED LH ENG NBR 8 FAN BLADE IAW AMM 72-31-02. NO FURTHER DEFECTS NOTED. BLADE W/ IN LIMITS AND NON-MEL ADDED FOR TRACKING PURPOSES ONLY. NON-MEL # 143392.</P>)
Part: STARTER — FAILED (APU) · airframe 76,207 hrs · 13,976 cycles
APU FAILED TO START. REMOVED AND REPLACED FAULTY STARTER PER 767 AMM 49-41-01. OPS CHECK GOOD 1ST START.
Part: BLADE — NICKED (LT ENG COMPRSSOR) · airframe 76,207 hrs · 13,976 cycles
LEFT ENG BLADE 31 HAS SMALL NICK ABOUT .080". DAMAGE FOUND TO BE WITHIN REPAIRABLE LIMITS FOR 'AREA; A" OF BLADE, BLENDED TO SMOOTH EDGE PER AMM 72-31-02, NO FURTHER DEFECTS NOTED.
Part: BLADE — NICKED (LT ENG COMPRSSOR) · airframe 76,207 hrs · 13,976 cycles
LEFT ENG BLADE 32 HAS SMALL NICK ABOUT .125" LENGTH AND .031" DEPTH. DAMAGE DEPTH AND LENGTH FOUND TO BE WITHIN REPAIRABLE LIMITS FOR "AREA. A" OF BLADE BLENDED TO SMOOTH EDGE PER AMM 72-31-02, NO FURTHER DEFECTS NOTED
Part: RELAY — MALFUNCTIONED (OVERBRD EXHAUST) · airframe 76,160 hrs · 13,964 cycles
AFTER ENGINE START RECEIVED "FWD EQUIP VAL" EICAS(<P>PERFORMED TEST ON GND IAW AMM 21-58-02-001. OPS CHECK OK. AS PER MCC, DEFERRED IAW MEL 21-58-01-01 PLAC. INSTALLED MDDR# 143049.</P><P>27FEB21 - LP 1302982 - ITEM# M3 - TPA -&NBSP;REMOVED AND REPLACED OVER BOARD EXHAUST RELAY K340 IAW SWDM 21-58-11 OPS CHK GOOD. THIS CLEARS MDDR 143049.</P>)
Part: RELAY — FAILED (GROUND BUSS) · airframe 76,142 hrs · 13,954 cycles
GROUND HANDLING BUS INOP (GROUND HANDLING BUS RELAYS -200, -300) TRANSFERRED TO DMI 142726 MEL 24-22-01-01-01, CAT C, DUE 02MAR21. "M" FUNCTION COMPLIED WITH. 21FEB21 - LP 1250891 - ITEM NR 1 - CVG; REMOVED AND REPLACED GROUND HANDLING RELAY IAW AMM 24-51-01. THIS CLEARS MDDR 142726.
Part: VALVE — FAULTED (LT ENGINE) · airframe 76,140 hrs · 13,953 cycles
LH ENG EEC INOP / ( EEC NORM MODE (PW4000/RB211) (NOTIFY DISPATCH) )(<P>PERF PIMU MX RECALL IAW FIM 71-01 FT. 804 - FAULTED "TCC TR-CK" T/S PER FIM 71-01 TASK 829 PERF TCC ACTUATION CHK IAW FIM 71-08 FT. 807 THROUGH BLOCK 22. SUSPECT TCC CONTROL CABLE / ACTUATOR TO BE AT FAULT PLACED CABLE P/N- 160S140-02 & ACTUATOR 5830201-111 ON ORDER WITH MCC. TRANSFERED TO MDDR 142660 IAW MEL 73-21-01-02 CAT C DUE 01MAR21. PLACARD INSTALLED. MCC NOTIFIED. A/C DOWNGRADED TO CAT II.</P><P>23FEB21 - LP 1250900 - ITEM# 15 - CVG - REMOVED AND REPLACED TCC AIR VALVE PER AMM 75-24-05. THIS CLEARS MDDR 142660.
Part: CIRCUIT CARD — MALFUNCTIONED (EQUIP COOLING) · airframe 76,072 hrs · 13,935 cycles
FWD EQUIP VALVE EICAS MSG AFTER BLOCK OUT(<P>REMOVED AND REPLACED&NBSP;EQUIP COOLING INBD CARD M867. OPS CHECK NORMAL IAW AMM 21-58-24.<BR /></P>)
Part: CONTROL VALVE — MALFUNCTIONED (APU SURGE) · airframe 76,028 hrs · 13,922 cycles
APU PNEUMATIC FUNCTION INOP ( AUXILIARY POWER UNIT, PNEUMATIC FUNCTION )(<P>FWD TO MDDR# 142033. APU AIR INOP MEL 49-11-01-01.</P><P>07FEB21 - LP 1333515 - ITEM# 2 - BWI - REMOVED AND REPLACED APU SURGE CONTROL VALVE IAW 767 AMM 49-53-01; OPS CHECK GOOD, AT THIS TIME, THIS CLEARS DMI 142033, REMOVED PLACARDS.<BR /></P>)
Part: ECU — FAILED (APU) · airframe 75,983 hrs · 13,908 cycles
APU INOPERATIVE. TRANSFERRED TO MDDR 141770 IAW MEL 49-11-01A & CAT C, LP 133495: R & R ECU IAW AMM 40-11-00 OPS CHK GOOD. THIS CLEARS MDDR 141770.
Part: TRANSCEIVER — FAILED (WX RADAR SYS) · airframe 75,921 hrs · 13,887 cycles
RIGHT SYSTEM WXR FAIL MESSAGE DISPLAY ON ND. LEFT SIDE OK. TRANSFERRED TO MDDR 141331 REF MEL 34-43-01. DUE DATE 23MAR21, CAT D. PLACARD INSTALLED. REMOVED AND REPLACED RIGHT WXR RADAR TRANSCEIVER, IAW AMM 34-43-01. PERFORMED RIGHT WX RADAR SYSTEM TEST, IAW 34-43-00, OPERATIONS CHECK OK. THIS CLEARS MDDR 141331.
Part: STRAP — LOOSE (HEAT EXCHANGER) · airframe 75,881 hrs · 13,874 cycles
LT PACK INOPERABLE. TRANSFERED TO MDDR 140817, PER 21-51-01-01 CAT C DUE DATE 12JAN21. MX ACTION C/W. REMOVE AND REPLACED RESTRAINT STRAP AT HEAT EXCHANGER DUCT AND LOOSE SUPPORT, IAW AMM 21-51-02-404-019. THIS CLEARS MDDR 140817. PLACARD REMOVED.
Part: PRIORITY VALVE — FAILED (RT BLEE) · airframe 75,877 hrs · 13,872 cycles
RIGHT ENGINE BLEED OFF, ZERO DUCT PRESSURE RIGHT SIDE. REMOVED AND REPLACED RT ENGINE PRV, PER MM 36-11-18, NO HELP. REQUIRE TROUBLESHOOTING (OFF PART: P/N 802170-9, S/N 900810). REMOVED AND REPLACED PRV CONTROLLER, RIGHT ENGINE (OFF PART: PN 792755-16, SN 200108016), AS PER AMM 36-11-19, NO HELP. REQ TROUBLESHOOTING. SECURED MUSCLE LINES TO RT ENGINE HPSOV AND PERFORMED AIR SUPPLY CHECK AND SYSTEM OPERATIONAL TEST, IAW AMM 36-11-00-715-149. OPERATIONS CHECK NORMAL.
Part: FUEL CONTROL — UNKNOWN (LT ENGINE) · airframe 75,881 hrs · 13,874 cycles
STARTING LEFT ENGINE T/O SPEEDS DROP OUT WHEN LEFT FUEL CONTROL GOES FROM OFF TO RUN. ON CDU "SPEEDS DROP OUT". PERFORMED ENGINE RUN, IAW AMM 71-00-00. NO DEFECTS.
Part: WARNING MESSAGE — FALSE ACTIVATION (NR 2 FIRE LOOP) · airframe 75,877 hrs · 13,872 cycles
NR 2 ENGINE LOOP 2 MESSAGE. TRANSFERRED TO MDDR 140747, IAW MEL 26-11-01-01. REMOVED AND REPLACED LOWER AFT FIRE DETECTOR ASSEMBLY NR 2, IAW AMM 26-11-02. OPERATIONS CHECK GOOD AT THIS TIME, THIS CLEARS DMI 140747. MCC NOTIFIED, PLACARD REMOVED.
Part: INLET — DAMAGED (NR 1 ENGINE) · airframe 75,879 hrs · 13,873 cycles
NR 1 INLET COWL HAS A SMALL DAMAGE AT 5:00 POS TAIL. ACCOMPLISHED PERMANENT HOT BOND COMPOSITE REPAIR OF NR 1 INLET COWL AT 5 O'CLOCK POSITION, PER AVENIR AVIATION FAA CAS 8AVR479B WO W15287 FEAM RO 5002395 FAA FORM 8130-3 ATTACHED.
Part: ENGINE — ODOR (NR 2) · airframe 75,877 hrs · 13,872 cycles
ON CLIMBOUT & DESCENT WE OBSERVED A VERY STRONG FUME ODOR (DIRTY SOCK SMELL). CARRIED OUT CHAPTER 5 CONDITIONAL INSPECTION FOR FUMES IN THE CABIN, PER AMM 05-51-56. FUMES SMELL DETERMINED TO BE COMING FROM RT ENGINE. REMOVED AND REPLACED NR 2 ENGINE ASSEMBLY, PER ATLAS AIR TASK CARD A-71-909-02-01.
Part: BLADE — DAMAGED (NR 2 ENGINE) · airframe 75,873 hrs · 13,870 cycles
ITEM NR 7 BORESCOPE INSPECTION NR 2 ENGINE SN: P724690, FOUND HPT NR 2, TWO EA BLADES WITH LEADING EDGE DENT AND CRACKS DAMAGE. REQUIRE ENGINE REPLACEMENT WITHIN 5 CYCLES. TRANSFERRED TO NON-MEL NR 140527.
Part: WARNING MESSAGE — FALSE ACTIVATION (FIRE LOOP) · airframe 75,853 hrs · 13,861 cycles
RT ENGINE FIRE LOOP STATUS MESSAGE. PERFORMED TEST OF ENGINE FIRE DETECTION SYSTEM, IAW B767 AMM 26-11-00. CLEARED FAULT. OPERATIONS CHECK GOOD.
2020
Part: WARNING MESSAGE — MALFUNCTIONED (RT ENG ANTI ICE) · airframe 75,667 hrs · 13,805 cycles
RIGHT ENGINE ANTI-ICE VALVE INITIALLY STAYED ILLUMINATED WHEN SELECTED ON. AFTER A FEW MINUTES IT WENT OUT AND OPERATED NORMALLY. THIS OCCURRED AFTER ENGINE START. PERFORMED OPERATIONS CHECK OF RIGHT ENGINE ANTI ICE VALVE, IAW 30-21-00. NO DEFECTS NOTED AT THIS TIME.
Part: WARNING LIGHT — FALSE ACTIVATION (EQUIP COOLING) · airframe 75,597 hrs · 13,783 cycles
INFO ONLY: EQUIPMENT COOLING VALVE LIGHT ILLUMINATED AFTER ENGINE START. SET TO STANDBY, PER CHECKLIST. VALVE LIGHT EXTINGUISHED. NORMAL OPERATIONS CONTINUED. T/S PER FIM 21-58 FT 939. SYSTEM OPERATION NORMAL, NO FAULTS NOTED AT THIS TIME.
Part: EEC — FAULTED (NR 1 ENGINE) · airframe 75,518 hrs · 13,758 cycles
EEC CATEGORY 2 FAULTS, EEC CHANNEL A AND B T5 CROSS CHECK FAIL ON ENGINE NR 1. T/S FIM 71-01-TASK 858, TIGHTENED ALUMEL; CHROMEL CONNECTION ENGINE 1; EBT SYS, PER AMM 77-21-03/501. OPERATIONS TEST OK.
Part: SEAL DEPRESSOR — DAMAGED (MCD) · airframe 75,518 hrs · 13,758 cycles
A/C ARRIVED WITH UNDOCUMENTED SPEED TAPE COVERING DAMAGE (A HOLE) IN AFT MCD SEAL DEPPRESSOR STATION 632 BETWEEN S-4L AND S-13L. REMOVED AND REPLACED DAMAGED SEAL DEPRESSOR AT MAIN CARGO DECK AFT MAIN CARGO DOOR CUT OUT STA 632, PER B767-300 SRM 51-40-02-0G-0.
Part: SEAL — DETERIORATED (ENG DRAIN MAST) · airframe 75,518 hrs · 13,758 cycles
NR 2 ENGINE DRAIN MAST PROTECTOR SEAL IS DETERIORATED. REPAIRED DETERIORATED FIRE INSULATION AT NR 2 ENGINE DRAIN MAST, IAW B767-3 AMM 78-31-01.
Part: SEAL — WORN (RT WING K FLAP) · airframe 75,518 hrs · 13,758 cycles
RT WING KRUEGER FLAP OUTBOARD SIDE SEAL IS WORN OUT. PREPARED, CLEANED AND REPAIRED WORN SEAL AT RT WING KRUEGER FLAP AT OUTBOARD SIDE, PER B767-300 AMM 52-09-00-358-056.
Part: SEAL — DAMAGED (ELT) · airframe 75,518 hrs · 13,758 cycles
COCKPIT ELT AUTO RELEASE SEAL DAMAGE P/N 1151324-1 S/N 087C-1179. REMOVED AND REPLACED COCKPIT ELT, PER MM 25-63-03-000-802.
Part: SEAL — DETERIORATED (AIR COOLER DUCT) · airframe 75,518 hrs · 13,758 cycles
NR 2 ENGINE OUTBOARD T/R COWL AIR COOLER DUCT SEALANT REPAIR IS DETERIORATED. REPAIRED DETERIORATED PROTECTOR SEAL (FIRE INSULATION), IAW B767-3 AMM 78-31-01 AT NR 2 ENGINE OUTBOARD T/R COWL AIR COOLER DUCT.
Part: OXYGEN BOTTLE — LOW PRESSURE (CABIN PORTABLE) · airframe 75,518 hrs · 13,758 cycles
COCKPIT PORTABLE OXYGEN BOTTLE PRESS LOW P/N 9800-2D1A-BF23A S/N 8136P. REMOVED AND REPLACED REFERENCED COCKPIT O2 BOTTLE, REF M/M 35-31-01-400-801-001.
Part: SEAL DEPRESSOR — DAMAGED (PAX DOOR) · airframe 75,518 hrs · 13,758 cycles
A/C ARRIVED WITH UNDOCUMENTED SPEED TAPE COVERING DAMAGE (A HOLE) ON FWD MCD SEAL DEPRESSOR STATION 492 BETWEEN 5-4L AND 5-13L. REMOVED AND REPLACED DAMAGED SEAL DEPRESSOR AT FWD MCD DOOR CUT OUT AT STA 492 B767-300 SRM 51-40-02-0G-0.
Part: SEAL — WORN (RT WING K FLAP) · airframe 75,518 hrs · 13,758 cycles
RT WING KRUEGER FLAP INBOARD SIDE SHOWS SEALS WORN OUT. PREPARED, CLEANED AND REPAIRED WORN SEAL AT RT WING KRUEGER FLAP INBOARD SIDE, PER B767-300 AMM 52-09-00-358-056.
Part: WARNING MESSAGE — FALSE ACTIVATION (EQUIP VALVE) · airframe 75,489 hrs · 13,747 cycles
FWD EQUIPMENT VALVE EICAS AFTER ENGINE START. TRANSFER TO MDDR 138266, IAW MEL 21-58-01, CAT C EXP 12/02/2020. PERFORM FIM 21-58 ST 43 940 AND FOUND NO FAULTS AT THIS TIME. OPERATIONS CHECKS GOOD. THIS CLEARS MDDR 138266.
Part: EXCITER — INOPERATIVE (LT ENGINE) · airframe 75,187 hrs · 13,654 cycles
LEFT ENGINE DID NOT START WITH NR 2 IGNITOR SELECTED. SWITCHED TO BOTH IGNITORS AND START WAS SUCCESSFUL. TRANSFERRED TO DMI 135990, IAW MEL 74-00-01B, CAT "C" DUE DATE 23OCT20, PLACARD INSTALLED. DISPATCH JD 06:40Z. CVG MX, 15OCT. REMOVED & REPLACED NR 2 IGNITION EXCITER, IAW AMM 74-11-01. PERFORMED ENGINE IGNITION SYSTEM AUDIBLE TEST, TASK 74-00-00, TEST PASS. PLACARDS REMOVED, DMI 135990 CLEARED ZH 1655Z.
Part: CONTROLLER — FAULTED (CABIN PRESSURE) · airframe 75,166 hrs · 13,644 cycles
CABIN ALT AUTO 1, . REMOVED AND REPLACED CAB ALT AUTO 1 CONTROLLER, IAW AMM 21-31-02. OPERATIONS CHECK GOOD AT THIS TIME.
Part: UNKNOWN — LEAKING · airframe 75,149 hrs · 13,638 cycles
DURING WALK AROUND NOTICED OIL POOLING AT THE BOTTOM OF THE LEFT ENGINE COWL. PERFORMED ENGINE VENTS & DRAIN INSPECTION, IAW AMM 71-71-00. LEAK FOUND TO BE WITHIN LIMITS, NO FURTHER DEFECTS NOTED AT THIS TIME.
Part: COVER — LOOSE (EMERGENCY LIGHTS) · airframe 75,137 hrs · 13,634 cycles
L1 EMERGENCY LIGHT COVER LOOSE. REINSTALLED LENS COVER, IAW AMM 33-51-01. OPERATIONS CHECK GOOD.
Part: WARNING HORN — INOPERATIVE (APU FIRE) · airframe 75,096 hrs · 13,614 cycles
APU FIRE HORN ON NOSE GEAR INOPERABLE. TRANSFER TO MDDR 135138, CAT C, PER DDG 26-15-01B, DUE 08OCT20. REMOVED AND REPLACED APU FIRE WARNING HORN ON P-40 PANEL. OPERATIONS CHECKS GOOD, IAW AMM 26-15-00. THIS CLEARS MDDR 135138. PLACARDS REMOVED. MCC NOTIFIED. TI SL 0823Z.
Part: STARTER — FAILED (APU) · airframe 75,036 hrs · 13,595 cycles
APU FAILED TO START. TRANSFERRED TO MDDR 134827, PER MEL 49-11-01A, CAT C, DUE 2 0CT 20. REMOVED AND REPLACED APU STARTER MOTOR. OPS CHECKS GOOD, IAW AMM 49-41-01. MCC NOTIFIED, PLACARD REMOVED (CLEARS DMI NR 134827) DI:DL 08:53Z.
Part: LINE — LEAKING (HYD SYSTEM) · airframe 74,899 hrs · 13,555 cycles
ON WALKAROUND FOUND HYD FLUID DRIPPING FROM LEFT ENGINE STRUT DRAIN.(<P><SPAN>FOUND HYD SUPPLY LINE ON STRUT ACCESS LOOSE, SECURE BNOT ON SUPPLY LINE, LEAK CHECK OK AS PER AMM 77-71-00 AT&NBSP; # 1 ENG.</SPAN><BR /></P>)
Part: FITTING — LEAKING (HYD SYSTEM) · airframe 74,899 hrs · 13,555 cycles
POSSIBLE HYDRAULIC LEAK FROM NO. 1 ENGINE STRUT DRAIN TUBE. ITEM M20: RESTRICTOR VALVE IN DOG HOUSE OF #1 ENGINE REQUIRES REPLACEMENT. REMOVED AND REPLACED "T" FITTING ON HYDRAULIC LINE IN AFT DOGHOUSE ON #1 ENGINE IAW AMM 20-11-00. PERFORMED LEAK CHECK IAW AMM 29-11-00, NO LEAKS FOUND AT THIS TIME. ITEM M20: REMOVED AND REPLACED RESTRICTOR VALVE IN #1 ENGINE DOGHOUSE IAW AMM 20-11-00. PERFORMED LEAK CHECK OF RESTRICTOR VALVE IAW AMM 29-11-00. NO LEAKS NOTED AT THIS TIME. P/N OFF: 9R3918, NSN.
Part: PLACARD — BROKEN (L1 DOOR) · airframe 74,776 hrs · 13,517 cycles
PLASTIC EMERGENCY EXIT SIGN ABOVE THE L1 DOOR HANDLE IS BROKEN. RESECURED PLASTIC EMERGENCY EXIT SIGN REF AMM 25-63-00. OPS CKS GOOD.
Part: SEAL — BROKEN (FLASHLIGHT) · airframe 74,614 hrs · 13,456 cycles
EMERGENCY FLASHLIGHT ON FLT DECK BY L1 DOOR HAS SEAL BROKEN. REMOVED AND REPLACED BROKEN SEAL IAW AMM 25-64-00.
Part: TRANSDUCER — MALFUNCTIONED (THRUST REVERSERS) · airframe 86,617 hrs · 20,636 cycles
DURING TAKEOFF RIGHT ENGINE DID NOT SPOOL UP. RIGHT THRUST LEVER WAS SUBSTANTIALLY FRAIL TO BE UNRESPONSIVE TO INPUTS. REMOVED AND REPLACED; RH ENG. T/R POSITION FEED BACK TRANSDUCER IAW AMM 78-36-03. RIG CONFIRMED. REQUIRES HIGH POWER RUN TO COMPLETE OPERATIONAL CHECK. ITEM 3:PERFORMED MAX POWER ASSURANCE TEST IAW 71-00-00. OPS CHECK OF T/R GOOD AT THIS TIME. ENGINE DOES NOT LAG. DATA-TEMP="1"
Part: WARNING MESSAGE — FALSE ACTIVATION (APU PNEUMATIC) · airframe 74,590 hrs · 13,445 cycles
APU PNEUMATIC SYSTEM INOPERATIVE, PERFORMED A BITE ON THE APU ECU. OPERATED APU SEVERAL TIMES, BOTH ELECTRICAL AND PNEUMATIC BLEED SYSTEM WORKING GOOD IAW FIM 49-11. FAULT TREE 958.
Part: COMBUST CHAMBER — CRACKED (NR 1 ENGINE) · airframe 74,590 hrs · 13,445 cycles
DURING A BOROSCOPE INSPECTION, FOUND THE NR 1 ENGINE WITH A CONTINUOUS AXIAL CRACK ON THE COMBUSTION CHAMBER OUTER LINER, AT THE 3 O`CLOCK POSITION. THE COMBUSTER 13 WAS PERMITTED TO CONTINUE ON A REDUCED TIME INSPECTION INTERVALS OF 125 CYCLES IAW AMM 72-00-00, AND W/C A-72-410-00-01.
Part: PLUG — UNDERSIZE (NR 2 ENGINE) · airframe 74,569 hrs · 13,437 cycles
DURING BOROSCOPE INSPECTION, DISCOVERED AP-9 BOROSCOPE PLUG AT THE 3.0 CLOCK POS ON DIFFUSER CASE, SHAFT DIAMETER IS METER IS LESS THAN 0.100 IN NR 2 ENGINE. REMOVED AND REPLACED AP-9 BOROSCOPE PLUG IAW 767 AMM 72-00-00-206-364.
Part: STATUS MESSAGE — FALSE ACTIVATION (WEATHER RADAR) · airframe 74,482 hrs · 13,408 cycles
STATUS MESSAGE WEATHER RADAR SYS. PERFORMED FIM 34-43 FT 805 UP TO AND INCLUDING SHEET 1, BLOCK 2. COULD NOT DUPLICATE DISCREPANCY. OPS CHECKED GOOD.
Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 74,408 hrs · 13,383 cycles
STATUS MESSAGE WXR SYS WENT ON RIGHT RADAR. PERFORMED FIM TASK 34-43 FAULT TREE 805 FIG 103. OPS GOOD.
Part: KNOB — LOOSE (WEATHER RADAR) · airframe 74,305 hrs · 13,345 cycles
WX RADAR TILT KNOB OFF 2 DEGREES FROM ACTUAL POS. 0 DEGREES ON KNOB INDICATES -2 DEGREES(<P>FOUND TILT KNOB LOOSE. SECURED AND PERFORMED WX RADAR OPERATIONAL SYSTEM TEST IAW AMM 34-43-00. OPS AND INDICATION NORMAL.</P>)
Part: CONTROL PANEL — FAULTY (WEATHER RADAR) · airframe 74,293 hrs · 13,340 cycles
WX RADAR TILT KNOB 2 DEGREES OFF FROM ACTUAL POSITION, KNOB SHOWS 7 ACTUAL IS 5 ETC.(<P>REMOVED AND REPLACED PANEL EFIS CONTROL IAW AMM 34-43-02, OPS TEST OK IAW AMM 34-22-02.</P>)
Part: CONTROL VALVE — MALFUNCTIONED (APU) · airframe 74,267 hrs · 13,332 cycles
APU AUTO SHUTDOWN / APU FAULT.(<P>APU DEFERRED IAW MEL 49-11-01A THIS IS A CAT "C" ITEM. APU ECU SHOWS "HIGH OIL TEMP" FAULT MDDR# 128079. TIME 22:49Z INT: JT DUE DATE 17MAY20.</P><P>LP 1140515: REMOVED AND REPLACED OIL TEMP CONTROL VALVE ASSY IAW AMM 49-27-10, APU OPS CHECK GOOD. THIS CLEARS MDDR 128079.</P>)
Part: ECU — FAULTED (APU) · airframe 74,267 hrs · 13,332 cycles
APU AUTO SHUTDOWN / APU FAULT.(<P>APU DEFERRED IAW MEL 49-11-01A THIS IS A CAT "C" ITEM. APU ECU SHOWS "HIGH OIL TEMP" FAULT MDDR# 128079. TIME 22:49Z INT: JT DUE DATE 17MAY20.</P>)
Part: TERMINAL — BROKEN (FIRE DETECTOR) · airframe 74,235 hrs · 13,320 cycles
RIGHT ENGINE FIRE LOOP 1 INOPERATIVE. REMOVED AND REPLACED THE CARD ASSY FIRE DETECTOR ENGINE 2 LOOP IAW AMM 26-11-01. FAULT COULD NOT BE DUPLICATED. FOUND LOWER AFT FIRE DETECTOR WITH A BROKEN TERMINAL, REPLACED THE TERMINAL AT TS 682 IAW WDM 26-11-21 AND SWPM 20-30-00, SYSTEM OPS CHECKED NORMAL.
Part: FIRE WARNING — FALSE ACTIVATION (COCKPIT) · airframe 74,207 hrs · 13,307 cycles
APU FIRE LP 1 STATUS MSG AFTER SHUTDOWN(<P>PERFORMED FIRE OVERHEAT TEST IAW AMM 26-11-01. OPS CHECK NORMAL.</P>)
Part: CONTROL VALVE — FAULTY (AC BAY) · airframe 74,195 hrs · 13,303 cycles
RH PACK TEMP EICAS MSG(<P><SPAN>T/S IAW B767 FIM 21-51 FT 844, FOUND TEMP CONTROL VALVE FAULT LIGHT ON PTC BUS. RIGHT TEMP CONTROL VALVE NOT IN STOCK. PLACED ON REQ WITH MCC. SEE LP #1189889 ITEM M8 FOR REPLACEMENT.</SPAN></P><P>LP 1189889 - M8: ITEM TRANSFERRED TO DMI #127293 IAW DDG 21-51-01-01, CAT 'C'. </P><P>LP 1190042: REMOVED AND REPLACED RH PACK ACM CONTROL VALVE IAW AMM 21-51-12. OPS CHECKS NORMAL. PERFORMED FIM TASK 21-51-00. NO FAULT LIGHTS NOTED, NO MESSAGES NOTED. OPS CHECKS NORMAL. THIS CLEARS MDDR 127293.</P>)
Part: STATUS MESSAGE — FALSE ACTIVATION (COCKPIT) · airframe 74,176 hrs · 13,297 cycles
CABIN ALT AUTO 1 STATUS MSG.(<P>COMPLIED WITH BITE TEST OF #1 AUTO CABIN PRESS CONTROLLER, TEST PASS, NO FAULTS LATCHED. OK FOR CONTINUED SERVICE I/A/W MM CH 21-31-00.</P>)
Part: ROTARY SWITCH — DEFECTIVE (COCKPIT) · airframe 74,080 hrs · 13,263 cycles
(THIRD GRIPE) APU SWITCH EXTENDS BEYOND START, THEN RETURNS TO START VICE ON POSITION. NEEDS ADJUSTMENT. APU OPERATES 4.0.(<P>TRANSFERRED TO MDDR 126667 IAW DDG 49-11-01A, CAT C, DUE DATE 14APR2020.</P><P>LOG PAGE 1150016 ITEM 2: REMOVED AND REPLACED APU ROTARY SWITCH PER SWPM 20-84-00. OPS CHECKED NORMAL. THIS CLEARS MDDR 126667. PLACARD REMOVED.</P>)
Part: SWITCH — LOOSE (APU) · airframe 74,076 hrs · 13,261 cycles
APU SWITCH LOOSE, APU OPERATES NORMALLY, SWITCH JUST NEEDS ADJUSTMENT.(<P>ADJUSTED APU SWITCH IAW AMM 49-61-00. OPS TEST OK.</P>)
Part: SWITCH — MALFUNCTIONED (COCKPIT) · airframe 74,086 hrs · 13,266 cycles
APU SWITCH STICKS IN START POSITION(<P>CHECKED APU SWITCH FOUND TO BE IN NORMAL OPERATION IAW AMM 49-61-00. NO FURTHER DEFECTS NOTED AT THIS TIME.</P>)
Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 74,044 hrs · 13,247 cycles
"FWD EQPT VAL" EICAS MSG AFTER ENGINE START. COMPLIED WITH QRH.(<P>PERFORMED T/S PER FIM 21-58 FT 939. NO FAULTS NOTED. SYSTEM OPS CHECK NORMAL.</P>)
Part: CONTROLLER — MALFUNCTIONED (BLEED AIR SYS) · airframe 74,031 hrs · 13,241 cycles
"LEFT HPSOV" STATUS MESSAGE(<P>TRANSFERRED TO MDDR 126380 PER MEL 36-11-02-01, CAT 'C'.</P><P>REF LOG PAGE 1226389 ITEM M4: REMOVED AND REPLACED #1 ENGINE VALVE HIGH PRESSURE SHUTOFF IAW AMM 36-11-02. OPS TEST AND LEAK CHECK OK. P/N OFF 802170-12, S/N OFF 940611.</P><P>REF LOG PAGE 1226389 ITEM M5; REMOVED AND REPLACED CONTROLLER ASSY HIGH PRESSURE #1 ENGINE IAW AMM 36-11-08. OPS TEST AND LEAK CHECK OK, THIS CLEARS DMI 126380.</P>)
Part: CONNECTOR — LOOSE (LT ENGINE) · airframe 74,031 hrs · 13,241 cycles
OIL QTY IND READING ZERO AND NO L OIL PRESSURE LIGHT ILLUMINATED.(<P>FOUND A CANON PLUG ON THE LEFT ENGINE LOOSE. TIGHTENED THE CONNECTOR IAW SWPM 20-63-00, OPS TEST GOOD. OIL QTY AND PRESSURE INDICATION WERE NORMAL. CANON PLUG TIGHTENED WAS D4208P. IAW AMM 79-32-00 AND 79-33-00.</P>)
Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 74,022 hrs · 13,236 cycles
LH ENG HPSOV EICAS MSG AFTER LANDING MESSAGE CLEARED PRIOR TO BLOCK IN.(<P>PERFORMED BITE CHECK OF THE AIR SUPPLY MODULE IAW B767 FIM 36-20 FT 804. NO FAULTS NOTED AT THIS TIME.</P>)
Part: TRU — MALFUNCTIONED (APU) · airframe 74,009 hrs · 13,230 cycles
APU TRU INOP.(<P>TRANSFERRED TO MEL NO. 24-32-01B, MDDR 125961, CAT 'D'.</P><P>LP 1167868: REMOVED & REPLACED APU START TRANSFOMER RECTIFIER UNIT IAW AMM 24-32-04. OPS CHECK GOOD. THIS CLEARS MDDR 125961.<BR /></P>)
Part: STATUS MESSAGE — FALSE ACTIVATION (CABIN PRESSURE) · airframe 73,989 hrs · 13,219 cycles
UPON SHUTDOWN THE FOLLOWING STATUS MESSAGE DISPLAYED: CABIN ALT AUTO 2.(<P>PERFORM BIT ON CABIN PRESSURIZATION CONTROLLER AND NO FAULT FOUND, AND ERASED MESSAGE IAW 21-31-TASK 802.</P>)
Part: EXHAUST FAN — FAILED (FWD EQUIP BAY) · airframe 73,951 hrs · 13,203 cycles
FWD EQUIPMENT EXHAUST FAN EICAS MESSAGE DISPLAYED AFTER FAULTY GPU POWER CART FAILURE.(<P>DEFERRED FORWARD EQUIPMENT COOLING EXHAUST FAN PER MEL 21-58-04-02-01, CAT "C", DUE ON 25FEB2020 AS PER MDDR 124720.</P><P>LP 1191221 - ITEM M1: REMOVED AND REPLACED FWD EQUIPMENT EXHAUST FAN IAW AMM 21-58-06. OPS CHECK NORMAL. NO DEFECTS NOTED. NO EICAS MESSAGE PRESENT. THIS CLEARS DMI 124720.</P>)
Part: UNKNOWN — ODOR (CABIN) · airframe 73,966 hrs · 13,209 cycles
"WET SOCK" POLYMERIZED OIL SMELL WHEN TAKEOFF THRUST IS SELECTED ON DEPARTURE&NBSP;(<P>INSPECTED PACK BAYS AND ENGINES FOR OIL LEAKS - FOUND NONE. REFERENCE AMM 21-51-02-206-020. RAN PACKS - OBSERVED NO POLYMERIZED OIL SMELL.</P>)
Part: VALVE — INOPERATIVE (TRIM AIR) · airframe 73,924 hrs · 13,196 cycles
AFT COMPARTMENT TRIM AIR VALVE INOP / (ZONE TRIM AIR MODULATING VALVES (ALL CARGO CONFIGURATION))(<P>TRANSFER TO MDDR #124467, REF MEL 21-61-04-02, CAT 'C', DUE 19FEB20. MX ACTION COMPLIED WITH.</P><P>LP 1183163, ITEM M11: REMOVED AND REPLACED AFT ZONE TEMP TRIM AIR MODULATING VALVE IAW AMM 21-61-07. OPS CHECK GOOD. THIS CLEARS MDDR 124467. PLACARD REMOVED.</P>)
Part: EXCITER — FAILED (NR 1, NR2 ENGINE) · airframe 73,830 hrs · 13,159 cycles
NR 2 ENG RISE, NO LIGHT OFF ON FIRST HALF. IGNITION SET TO BOTH AND ENGINE STARTED NORMALLY ON SECOND ATTEMPT. PERFORMED AMM 74-00-00-705-012 AUDIBLE TEST. FAILED ON THE NR 1 POSITION. REMOVED AND REPLACED THE NR 1 IGNITION, NR 2 ENGINE EXCITER BOX IAW AMM 74-11-01. PERFORMED AUDIBLE TEST IAW AMM 74-00-00. OPS CHECKED GOOD.
Part: ISOLATION VALVE — FAILED (DUCT) · airframe 73,828 hrs · 13,157 cycles
NO RIGHT DUCT PRESSURE INDICATION AFTER SELECTION. REMOVED AND REPLACED THE RIGHT ISOLATION VALVE ASSY IAW AMM TASK 36-11-04-004-001, & TASK 36-11-04-404-013, OPS & LEAK CHECKED GOOD. A/C RELEASED FOR SERVICE.
Part: CONNECTOR — DIRTY (ISOLATION VALVE) · airframe 73,774 hrs · 13,140 cycles
AFTER LANDING R ISLN VALVE CAUTION MSG CAME ON. CLEANED CONNECTOR FWD RT ISLN VALVE AND OPS CHK NORMAL, MSG CLEARED, REF AMM 36-11-04-214.
Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 73,745 hrs · 13,133 cycles
EICAS R BLEED ISLN VALVE. C/W SUPPLY SYS BITE TEST PER AMM 36-23-00. PERFORMED BITE TEST ON AIR SUPPLY CENTER SYS PER AMM 36-23-00. NO CURRENT FAULTS NOTED. A/C OK FOR SERVICE.
2019
Part: RECTIFIER — FAILED (APU STARTER) · airframe 73,559 hrs · 13,061 cycles
APU FAILED TO START AFTER 2 ATTEMPTS. PERFORMED FIM TASK 49-61-00 AND FOUND APU ECU AT FAULT. REMOVED AND REPLACED ECU IAW AMM 49-61-00. OPS CHECKED NORMAL. PERFORMED FIM TASK 49-61-00. FOUND APU STARTER T/R AT FAULT, REMOVED AND REPLACED IAW AMM 49-61-02. OPS CHECKED NORMAL.
Part: APU — FAULTED · airframe 73,554 hrs · 13,059 cycles
"APU FAULT" EICAS MSG ON 1ST ATTEMPT, SECOND ATTEMPT SUCCESSFUL.(<P>PERFORMED APU BITE PROCEDURE AND FOUND NO FAULTS ON THE ECU IAW B767 FIM 49-11 FT 987. OPS CHECK GOOD ON THE APU, NO FURTHER DEFECTS NOTED AT THIS TIME.</P>)
Part: BLADE — NICKED (NR 1 ENG FAN) · airframe 73,554 hrs · 13,059 cycles
#2 ENGINE #14 C1 FAN BLADE HAS A NICK IN THE TIP AREA.(<P>BLENDED NICK IN TIP AREA ON #2 ENG #14 C 1 FAN BLADE IAW AMM 72-31-02-308-003. REMOVED APPROXIMATELY .030", WITHIN LIMITS.</P><P><BR DATA-MCE-BOGUS="1" /></P><P>(NOTE: LP 1075824 - M6: DMI 121960 OPENED FOR&NBSP;INSPECTION WITHIN 7 FLIGHT CYCLES)</P>)
Part: STATUS MESSAGE — FALSE ACTIVATION (EXHAUST FAN) · airframe 73,353 hrs · 12,981 cycles
AFT EQ EXH FAN 2 STATUS MSG.&NBSP;(<P>TRANSFERRED TO MDDR #119722 IAW MEL 21-58-05, CAT 'C'. PLACARDS INSTALLED, NO OTHER DEFECTS NOTED.&NBSP;</P><P>LP 1100764 - M10: PERFORMED FIM 21-26 FT 808. ERASED MSG PER FIM 31-41-00, OPS CHECK NORMAL. PERFORMED INSPECTION OF BOTH FANS, OPS CHECK NORMAL, NO DEFECTS NOTED. MDDR #119722 CLOSED. PLACARDS REMOVED AND MCC NOTIFIED.</P>)
Part: GASKET — FAILED (FLOW SENSOR) · airframe 73,353 hrs · 12,981 cycles
APU INOPERATIVE, NO DUCT PRESSURE. PERFORMED IGU PUSH PULL TEST OF APU IAW FIM 49-11 FAULT TREE 975 AND FOUND LESS THAN 2 PDS FORCE REQUIRED. ALSO, REMOVED AND REPLACED FLOW SENSE VALVE GASKET IAW AMM 49-53-08 AND SURGE CONTROL VALVE AFT RUBBER DUCT IAW AMM 49-53-00.
Part: APU — UNKNOWN · airframe 73,323 hrs · 12,969 cycles
APU FAILED TO START ON TAXI IN.&NBSP;(<P>PERFORMED TWO SUCCESSFUL APU STARTS IN A ROW WITH NO DEFECTS NOTED PER AMM 49-00-00, OPS NORMAL.&NBSP;</P>)
Part: LATCH — BROKEN (ACCESS PANEL) · airframe 73,315 hrs · 12,966 cycles
#2 ENGINE OIL ACCESS PANEL UPPER LATCH BROKEN.&NBSP;(<P>TRANSFERRED TO NON-MEL MDDR 119475 IAW GMM 3.24.2, DUE 31-OCT-2019.&NBSP;</P><P>LP 1113028 - M8: REMOVED AND REPLACED #2 ENGINE OIL ACCESS PANEL, UPPER LATCH IAW AMM 71-11-08. OPS CHECK GOOD AT THIS TIME. THIS CLEARS NON MEL 119475. MCC NOTIFIED.&NBSP;</P>)
Part: LIGHT — UNKNOWN (START VALVE) · airframe 73,202 hrs · 12,931 cycles
LEFT ENG VALVE LIGHT DID NOT CYCLE ON AND OFF DURING ENGINE START. C/W OPERATIONAL TEST OF LEFT ENGINE START VALVE LIGHT SEVERAL TIMES IAW AMM 80-11-00, COMES ON AND OFF AS REQUIRED.
Part: NOZZLE — OBSTRUCTED (EXTINGUISHER) · airframe 73,200 hrs · 12,930 cycles
FIRE NOZZLE BLOCKED IN AFT CARGO AT STATION 1150.(<P>REMOVED OBSTRUCTION FROM NOZZLE AS PER AMM 26-23-00, ALL OTHER NOZZLES OK (CLEAR).<BR /></P>)
Part: SENSOR — MALFUNCTIONED (APU OIL TEMP) · airframe 73,149 hrs · 12,911 cycles
APU AUTO SHUTDOWN WITH APU FAULT EICAS MSG. PERFORMED APU BITE CHECK IAW FIM 49-11 FAULT TREE 958. ON LAST THREE STARTS/AUTO SHUTDOWNS, FOUND HIGH OIL TEMP FAULT. STARTED APU TWICE WITH NO FAULTS OR ISSUES, PERFORMED FIM 49-11 FAULT TREE 958. NO CURRENT MINI FLAGS PRESENT. PREVIOUS MINI FLAGS WAS FAULT 10. MEASURED RESISTANCE AT ECU PINS E4 AND E5 ON CONNECTOR D408B. FOUND 112 OKAY WHICH IS IN ALLOWABLE RANGE. REMOVED AND REPLACED APU LOW OIL TEMP SWITCH IAW AMM 49-27-14. REMOVED AND REPLACED APU OIL LUBE FILTER ELEMENT IAW AMM 49-27-03. PERFORMED APU EXTERNAL INSPECTION IAW AMM 49-21-00, INSPECTED APU MAGNETIC CHIP DETECTORS IAW AMM 49-27-04. NOTHING ABNORMAL FOUND. REMOVED AND REPLACED APU OIL TEMP SENSOR IAW AMM 49-94-01. LEAK CHECKED OK, RUN OK.
Part: SHUTOFF VALVE — LEAKING (HYDRAULIC SYS) · airframe 73,006 hrs · 12,860 cycles
HYD FLUID NOTED ON WING FAIRING ABOVE LEFT MAIN GEAR. REMOVED AND REPLACED HYD VALVE ASSY - SHUTOFF CONTROL IAW AMM 24-25-01. OPS CHECK GOOD, NO LEAKS AT THIS TIME.
Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 72,977 hrs · 12,846 cycles
APU FAULT MESSAGE ON LOWER EICAS. PERFORMED APU CONTROL UNIT BITE TEST IAW AMM 49-61-05 - FAULT NO LONGER PRESENT. PERFORMED APU START IAW AMM 49-11-00 NO FAULTS NOTED. NOTE: PER MCC REQUEST - AN APU COLD SOAK START VERIFICATION DEFERRAL WAS OPENED (MDDR 117524) DDG 25-AP-01; (ETOPS PROGRAM)
Part: THERMOCOUPLE — FAILED (LT BLEED VALVE) · airframe 72,886 hrs · 12,814 cycles
DURING ENGINE CHECK, FOUND PIMU MSG EEC CH-A T 29 RNG FAIL. REMOVED AND REPLACED LEFT 2.9 BLEED VALVE THERMOCOUPLE PROBE IAW AMM 75-32-06, OPS CHECK GOOD.
Part: OUTFLOW VALVE — INOPERATIVE (CABIN PRESSURE) · airframe 72,886 hrs · 12,814 cycles
DURING WINDOW PRESSURE LEAK CHECK, FOUND CABIN OUTFLOW VALVE DC-MAN INOP.(<P>REMOVED AND REPLACED CABIN PRESSURE OUTFLOW VALVE. OPS CHECK NORMAL PER B767 AMM 21-31-03.</P>)
Part: SHUTOFF VALVE — INOPERATIVE (LT FUEL SYSTEM) · airframe 72,886 hrs · 12,814 cycles
LEFT FUEL SHUTOFF VALVE INOPERATIVE. REMOVED AND REPLACED FUEL SHUTOFF VALVE ASSY IAW AMM 28-21-02. OPS CHECK AND LEAK CHECK NORMAL, NO LEAKS NOTED AT THIS TIME.
Part: HINGE — DAMAGED (RAM AIR DOOR) · airframe 72,886 hrs · 12,814 cycles
LEFT RAM AIR MODULATION DOOR HINGE PIN (INLET), AFT HINGE DAMAGED.(<P>REMOVED AND REPLACED TWO HINGES AND HARDWARE AS NECESSARY. OPS CHECK OK PER B767 AMM 21-53-01.</P><P><BR DATA-MCE-BOGUS="1" /></P><P>FWD HINGE OFF PART (SN: NSN, PN: 213T3109Y16)</P>)
Part: STARTER — LEAKING (NR 1) · airframe 72,886 hrs · 12,814 cycles
#1 STARTER OIL QTY DRAIN IS LESS THAN 17 OZ. REMOVED AND REPLACED #1 STARTER IAW B767 AMM 80-11-01, OPS CHECK GOOD.&NBSP;</P>)
Part: CHARGER — INOPERATIVE (APU BATTERY) · airframe 72,876 hrs · 12,810 cycles
APU BATT CHARGER STATUS MESSAGE. REMOVED AND REPLACED APU BATTERY CHARGER IAW AMM 24-31-05. RAN APU BATT CHARGER TEST, NO FAULTS NOTED. NO MSG PRESENT.
Part: CHARGER — INOPERATIVE (APU BATTERY) · airframe 72,860 hrs · 12,806 cycles
DURING DAILY CHECK DISCOVERED APU CHARGER INOPERATIVE. DURING DAILY CHECK DISCOVERED APU BATTERY LOW VOLTAGE. AFTER ONE HOUR OF APU OPERATION, DISCOVERED APU BATTERY CHARGER STATUS MESSAGE. UNABLE TO CLEAR MESSAGE. REMOVED AND REPLACED APU BATTERY CHARGER IAW AMM 24-31-05, OPS CHECK GOOD. REMOVED AND REPLACED APU BATTERY IAW AMM 24-31-04. OPS CHECK GOOD. REMOVED AND REPLACED APU BATTERY CHARGER SYSTEM. OPS CHECK GOOD AT THIS TIME IAW AMM 24-31-05.
Part: GAUGE — FAULTED (CABIN PRESSURE) · airframe 72,858 hrs · 12,805 cycles
CABIN ALT DISPLAY INDICATES ERRATIC AT FL 40 ALT. VARIED FROM 7.000 TO 10.000 WITH RATE FULLY PEGGED IN BOTH A CLIMB AND DESCENT. DIFF PRESSURE WAS CONSTANT. FOUND CABIN PRESSURE GAUGE FAULTY, REMOVED AND REPLACED PRESSURE GAUGE IAW REF AMM 21-33-01, OPS CHECKS OF SYS PER AMM 21-33-01-401 NO FAULTS NOTED.
Part: WARNING MESSAGE — FALSE ACTIVATION (FUEL PUMPS) · airframe 72,832 hrs · 12,796 cycles
ON TAXI OUT, L CTR FUEL PUMP AND R CTR FUEL PUMP EICAS MSG WITH 2.2 IN CENTER TANK. ASSOCIATED FUEL CONFIG WITH PUMPS OFF. BOTH PUMPS OPS CHECKED GOOD DURING FUNCTIONAL CHECK. OPS CHECK IAW AMM 28-22-00.
Part: UNKNOWN — MALFUNCTIONED (WEATHER RADAR) · airframe 72,817 hrs · 12,791 cycles
LEGITIMATE RADAR RETURNS INTERMITTENTLY DISPLAYED WITH GCS ON, OPS OK WITH GCS OFF. (<P>PERFORMED OPERATIONAL TEST OF WEATHER RADAR SYSTEM REF AMM 34-43-02-715-001-001. OPS CHECKED NORMAL AT THIS TIME.&NBSP;</P>)
Part: CONTROL PANEL — MALFUNCTIONED (FIRE WARNING) · airframe 72,728 hrs · 12,764 cycles
MAIN CARGO FIRE LOOP B WONT EXTINGUISH. (<P>TRANSFER TO MDDR # 114806 IAW DDG 26-16-02-01. PLACARD INSTALLED.</P><P>LP 1089248 - ITEM 1: REMOVED AND REPLACED CARGO FIRE CONTROL PANEL IAW AMM 26-22-03. OPS CHECKED GOOD IAW AMM 26-11-01. THIS CLEARS DMI 114806. NOTIFIED MCC AND PLACARD REMOVED.<BR /></P>)
Part: OXYGEN MASK — INOPERATIVE (COCKPIT) · airframe 72,687 hrs · 12,749 cycles
RT SUPERNUMERY SEAT O-2 MASK INOP.(<P>TRANSFERRED TO MDDR #114438</P><P><SPAN>REMOVED AND REPLACED RIGHT SUPERNUMERY OXYGEN MASK BOX IAW AMM 35-11-51</SPAN><BR DATA-MCE-BOGUS="1" /></P>)
Part: WIRE — DISCONNECTED (FIRE LOOP) · airframe 72,574 hrs · 12,710 cycles
RT ENG FIRE LOOP 1 STATUS MESSAGE. T/S IAW FIM 26-11 FT 804, FOUND WIRE AT FIRE LOOP TERMINAL DISCONNECTED. INSTALLED NEW TERMINAL IAW SWPM 20-30-11. PERFORMED FIRE LOOP TEST IAW AMM 26-11-00, SYSTEM TEST NORMAL.
Part: STATUS MESSAGE — FALSE ACTIVATION (EXHAUST FAN) · airframe 72,564 hrs · 12,707 cycles
STATUS MSG AFT EQ EXH FAN 2. PERFORMED SYSTEM TEST OF THE EQUIPMENT COOLING SYSTEM NO FAULTS FOUND AFT EQUIPMENT EXHAUST FAN 2 APPEARS TO OPERATE NORMAL IAW AMM 21-58-00</P>)
Part: WARNING MESSAGE — FALSE ACTIVATION (FIRE LOOP 1) · airframe 72,527 hrs · 12,694 cycles
RIGHT ENG FIRE LOOP 1 STATUS MESSAGE AFTER BLOCK IN. PERFORMED ENGINE FIRE OVHT TEST IAW B767 AMM 26-13-00. MESSAGE CLEARED, NO FURTHER FAULTS NOTED AT THIS TIME.
Part: WARNING LIGHT — FALSE ACTIVATION (RT ENG FIRE LOOP) · airframe 72,529 hrs · 12,695 cycles
RIGHT ENG FIRE LP 1 STATUS MESSAGE ON TAXI IN AND AFTER ENGINE SHUTDOWN. ERFORMED OPERATION CHECK IAW AMM 26-11-00 AND ALSO CREW COMMENTS NO FAULTS DURING FLIGHT.
Part: LEAD — FAILED (APU IGNITION) · airframe 72,522 hrs · 12,692 cycles
DURING DAILY CHECK, FOUND APU INOPERATIVE, NO LIGHT OFF. PERFORMED FIM 49-11 FT 964. REMOVED AND REPLACED IGNITION LEAD IAW AMM 49-41-04.
Part: VALVE — WARNING MESSAGE (TRIM AIR) · airframe 72,518 hrs · 12,690 cycles
FLT DECK TEMP EICAS MESSAGE.. REMOVED AND REPLACED FLT DECK TRIM AIR VALVE IAW AMM 21-61-00. OPS CHECK GOOD.
Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 72,498 hrs · 12,684 cycles
RT ENG FIRE LOOP MESSAGE. (<P>RESET SYSTEM. OPS CHECKS GOOD PER B767 AMM 26-21-00.</P>)
Part: UNKNOWN — MALFUNCTIONED (APU) · airframe 72,451 hrs · 12,669 cycles
APU FAILED TO START AFTER LANDING THREE STARTS WERE ATTEMPTED.(<P>TRANSFER TO DMI# 111430 MEL 49-11-01A CAT C DUE 20MAY19 PLACARDS INSTALLED. </P><P><SPAN>LP 1073230: PERFORMED ECU BITE, NO FAULTS NOTED. PHYSICALLY CHECKED APU OIL QUANTITY. PERFORMED THREE SUCCESSFUL STARTS, NO DEFECTS NOTED IAW FIM 49-11 FT 959.</SPAN></P>)
Part: EXCITER — MALFUNCTIONED (APU) · airframe 72,440 hrs · 12,665 cycles
APU FAULT MESSAGE AFTER LANDING(<P>REMOVED AND REPLACED&NBSP;APU EXCITER IAW AMM 49-41-03. OPS CHECK GOOD. NO OTHER DEFECTS NOTED AT THIS TIME.&NBSP;</P>)
Part: WINDOW — FAILED (L1) · airframe 72,448 hrs · 12,667 cycles
FL 390, L1 WINDOW OUTER PANEL SHATTERED, QRH COMPLIED WITH AND GOOD PRESSURIZATION .(<P>REMOVED L1 WINDOW, INSPECTED WINDOW FRAME. NO DEFECTS NOTED. INSTALLED WINDOW PER AMM 56-11-01.</P>)
Part: UNKNOWN — UNKNOWN (GROUND POWER) · airframe 72,401 hrs · 12,652 cycles
UPON ARRIVAL, GROUND POWER COULD NOT BE USED.(<P>TESTED BPCU FOR FAULTS, NONE FOUND. RESET POWER AND SYSTEM OPERATES NORMAL IAW AMM 24-22-00-745-071.<BR /></P>)
Part: ANTI-ICE SYSTEM — MALFUNCTIONED (ENGINE) · airframe 72,346 hrs · 12,633 cycles
ENG. ANTI-ICE LIMITATION EXCEDED A/I ON AT 18C.(<P>PERFORMED OPERATIONAL TEST ON ENGINE PROBE HEAT SYSTEM PER AMM 30-34-00, OPS CHECK GOOD. COULD NOT DUPLICATE FAULT, MCC NOTIFIED. ALSO PERFORMED FIM 30-21 FT 805, SYSTEM OK.</P>)
Part: WARNING MESSAGE — FALSE ACTIVATION (ISOLATION VALVE) · airframe 72,357 hrs · 12,637 cycles
R BLD ISLN VAL ADVISORY MESSAGE ON TAXI IN.(<P>PERFORMED BITE TEST OF AIR SUPPLY CONTROL SYSTEM IAW AMM 36-23-00 AND FOUND NO FAULTS. OPS CHECKED R BLEED ISOL VALVE AND MSG CLEARED. NO FURTHER DEFECTS NOTED AT THIS TIME IAW AMM 33-11-00.<BR /></P>)
Part: BATTERY — INOPERATIVE (APU) · airframe 72,338 hrs · 12,631 cycles
APU BATTERY REQUIRES REPLACEMENT. APU INOP.(<P>REMOVED & REPLACED APU BATTERY IAW B767 AMM 24-31-04.</P><P>APU FAILED TO START, APU PLACED ON DEFERRAL IAW DDG 49-11-01A&NBSP; - MDDR 109619 CAT C.</P><P>LP 1018464: PERFORMED OPS TEST I.A.W B767 AMM 49-11-00.&NBSP;</P><P>LP 1018466: APU COLD SOAK START ACCOMPLISHED SUCCESSFULLY.&NBSP;</P><P><BR /></P>)
Part: HEATER — INOPERATIVE (R1 WINDOW) · airframe 72,355 hrs · 12,636 cycles
R1 WINDOW HEAT INOP.(<P>INSPECTED & OPS CHK R1 WINDOW HEAT PER AMM 56-11-00-216. NO ARCHING NOTED AT THIS TIME. GOOD FOR SERVICE. MCC NOTIFIED.<BR /></P>)
Part: CONTROL UNIT — MALFUNCTIONED (EXTERNAL POWER) · airframe 72,338 hrs · 12,631 cycles
EXTERNAL POWER SYSTEM INOP(<P>TRANSFERRED TO MDDR 109540.&NBSP;</P><P>LP 1018457 - M6:&NBSP;R&R EXT POWER RECEPTACLE IAW AMM 24-41-02-002-009 & 24-41-02-422-014, REF LOG PAGE 1018458 M7 FOR EXT PWR OPS CHECK.&NBSP;</P><P>LP 1018458 - M7:&NBSP;PERFORMED EXT POWER OPS CHECK IAW AMM 24-41-02. OPS CHECK FAILED. DMI 109540 REMAINS OPEN.&NBSP;</P><P>LP 1018458 - M8:&NBSP;REMOVED AND REPLACED BPCU IAW AMM 24-41-03. EXT POWER OPS CHECK GOOD AT THIS TIME. THIS CLEARS MDDR 109540 MCC NOTIFIED. PLACARDS REMOVED.&NBSP;</P>)
Part: O-RING — CUT (LT ENGINE) · airframe 72,294 hrs · 12,614 cycles
UPON WALKAROUND FOUND LEFT ENGINE LEAKING FUEL. (<P>FOUND FUEL PUMP FILTER O RING TO BE CUT. REMOVED AND REPLACED O RING IAW AMM 73-11-02. LEAK CHECK GOOD, NO FURTHER DEFECTS NOTED.</P>)
Part: WARNING SYSTEM — FALSE ACTIVATION (CABIN PRESSURE) · airframe 72,202 hrs · 12,581 cycles
CABIN ALT AUTO 1&NBSP;(<P>PERFORMED BITE TEST ON CABIN ALTITUDE CONTROLLER IN AMM 21-31-01, NO LONGER SHOWING FAULT.</P>)
Part: IGNITER BOX — DEFECTIVE (APU) · airframe 72,206 hrs · 12,582 cycles
APU WILL NOT START(<P>REMOVED AND REPLACED APU EXCITER IGNITION BOX IAW AMM 49-41-03. OPS CHECK NORMAL.&NBSP;<BR /></P>)
Part: CONTROLLER — MALFUNCTIONED (CABIN TEMP) · airframe 72,157 hrs · 12,561 cycles
CAB AUTO 2 MSG. PLACED ON MDDR 107362.&NBSP;&NBSP;(<P>REPLACED CAB TEMP CONTROLLER 2. CKS GOOD PER AMM 21-31-02. CLOSED MDDR</P>)
Part: CONTACT — DIRTY (EMERGENCY LIGHT) · airframe 72,157 hrs · 12,561 cycles
EMERGENCY LIGHT TEST AT GALLEY PANEL WENT OFF WITHIN 20 SECONDS. TASK CARD CALLS FOR AFTER ONE MINUTE.&NBSP;(<P>CLEANED CONTACTS AT M736. OPS CHECK NORMAL IAW AMM 35-51-00 AND SWPM 20-60-01.</P>)
Part: CONNECTOR — DAMAGED (RT A/C PACK) · airframe 72,157 hrs · 12,561 cycles
RT PACK O/H SWITCH CONNECTOR PLUG HAS BACK SHELL DAMAGED. S556 (COMPRESSOR OUTLET O/H SWITCH).(<P>R/R BACK SHELL ON D1562 IAW B767 AMM 20-60-09. OPS CHECK GOOD.&NBSP;</P>)
Part: IGNITER BOX — INOPERATIVE (APU) · airframe 72,136 hrs · 12,551 cycles
APU FAULT ON 3 START ATTEMPTS, APU WILL NOT START.(<P>R&R IGNITER BOX AND IGNITER IAW 767 AMM&NBSP; 49-41-03-401-010.<BR /></P>)
Part: RELAY — FAULTED (IDG) · airframe 72,095 hrs · 12,535 cycles
L IDG VALVE STATUS MSG. AFTER BLOCK IN.(<P>TRANSFER TO DMI 107020 PER DDG 75-21-01-03A CAT C MBCB 17FEB19 MPCW PLACARD INSTALLED&NBSP; DISPATCH SD 0801Z<BR /></P><P>LP 1018704-M2 T/S PERF FIM 24-20 FT 820 REPLACED RELAY 1033 PER STEP 5 NOTE RAN #1 ENG AT IDLE FOR 15 MN NOT FAULTS NOTED&NBSP; THIS CLEARED MDDR 107020, PLACARDS REMOVED.</P>)
Part: SOCKET — DIRTY (IDG) · airframe 72,093 hrs · 12,534 cycles
L IDG VALVE STATUS. CLEANED IDG SOCKET PER FIM 24-20 FT 802, WHICH CLEARED MSG.
Part: SWITCH — FAULTY (START VALVE) · airframe 72,016 hrs · 12,507 cycles
LEFT ENG START VALVE TEST OK BUT DID NOT ILLUMINATE DURING ENGINE START(<P>TRANSFER TO MDDR 106164 PER MEL 80-00-01-01 PLACARD INSTALLED&NBSP;</P><P>LP 927414 -M3 REMOVED AND REPLACED LT ENGINE START VALVE SWITCH IAW SWPM 20-84-15 REINSTALLED ENGINE START PANEL OPS CHECK GOOD THIS CLEARED DMI 106164</P>)
Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 71,989 hrs · 12,497 cycles
HI FLOW INHIBIT ON STATUS PAGE(<P>PERFORMED PACK TEMP CONTROL BITE CHECK REF FIM 21-61-00 FAULT TREE 803 MSG CLEARED NO DEFECTS NOTED</P>)
2018
Part: BATTERY — DEFECTIVE (APU) · airframe 71,920 hrs · 12,468 cycles
APU BAT CHGR STATUS MSG. REPLACED APU BATTERY, SYSTEM CHECK GOOD IAW AMM 24-31-04.
Part: WARNING MESSAGE — FALSE ACTIVATION (APU BATTERY) · airframe 71,920 hrs · 12,468 cycles
APU BAT CHARGE&NBSP; STATUS MESSAGE&NBSP;(<P>PERFORMED&NBSP; FIM 24-31 FT 805 MESAGE CLEARED APU BATTERY&NBSP; 28V&NBSP;</P>)
Part: INDICATION SYS — FALSE INDICATION (COCKPIT) · airframe 71,920 hrs · 12,468 cycles
ENG 3 FAN VIBRATION INDICATOR OF UP TO 4.5 DURING CLIMB NO PHYSICAL VIBRATION. INSPECTED INLET AND EXHAUST AREAS CHECKED FOR LOOSE DUCTS ON ENG AND NONE FOUND OK FOR SERVICE REF AMM 71-00-00.
Part: UNKNOWN — MALFUNCTIONED (FUEL SYSTEM) · airframe 71,870 hrs · 12,453 cycles
DURING 2 HOUR VERIFICATION FLIGHT, EXPERIENCED 2 FUEL MIGRATIONS FROM LT TO RT OF 1500 LBS BOTH TIMES. PERFORMED OPS CHECK OF ENGINE FUEL FEED SYSTEM AND INSP OF FUEL TANKS FOR LEAKAGE PER AMM 28-22-00 AND 28-11-00. COULD NOT DUPLICATE FUEL TRANSFER FIND EXTERNAL LEAKS. C/W SERVICE LETTER 767-56-28-05A. CHECKS OK AT THIS TIME.
Part: OXYGEN BOTTLE — LEAKING (PAX O2 SYS) · airframe 71,837 hrs · 12,440 cycles
PAX O2 BOTTLE 2 IS LEAKING, VALVE TO OPEN BOTTLE IS SLIGHTLY BENT AND VALVE HANDLE IS VERY LOOSE.(<P><SPAN>INSTALLED / NEW O2 BOTTLE IN POS 2 IAW B767 AMM REF 12-15-08, NO LEAKS NOTED&NBSP;</SPAN></P>)
Part: VALVE — FAULTY (IDG) · airframe 71,729 hrs · 12,402 cycles
LEFT IDG VALVE STATUS MESSAGE. PERFORMED FIM UP TO BLOCK 4 24-20 FAULT TREE 802, NO DEFECTS NOTED AT THIS TIME PER CHECK. IDG DELTA P NO DEFECTS RAN ENGINES IAW AMM 71-00-00 NO FAULTS NOTED. REMOVED AND REPLACED THE LEFT ENGINE IDG VALVE AMM 24-11-12. PERFORMED ENGINE RUN IAW AMM 71-00-00 AND OPS CHECKED NORMAL AT THIS TIME.
Part: RELAY — FAILED (LT IDG) · airframe 71,718 hrs · 12,399 cycles
LT IDG VALVE STATUS MSG. PERFORMED FIM TASK 24-20 FT 802. R&R IDG VALVE FAILURE RELAY (K1033) IAW SWPM 20-81-11 NO FAULTS NOTED. MSG CLEARED.
Part: STATUS MESSAGE — FALSE ACTIVATION (COCKPIT) · airframe 71,695 hrs · 12,390 cycles
CABIN ALT AUTO 1 STATUS MESSAGE DISPLAYED. PERFORMED BITE TEST IAW AMM 21-31-00. MESSAGE CLEARED, OPS CHECK OK NO FAULTS AT THIS TIME.
Part: STATUS MESSAGE — FALSE ACTIVATION (COCKPIT) · airframe 71,691 hrs · 12,388 cycles
LT IDG VALVE. MSG CLEARED IAW FIM 24-20 FT 802.
Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 71,693 hrs · 12,389 cycles
CTR LEFT FUEL PUMP LIGHT ILLUMINATED WITH 1.1 K IN CENTER IN TANK. PERFORMED OPS CHECK PER AMM 28-42-00, ALL CHECKS OK NO FAULTS NOTED.
Part: UNKNOWN — MALFUNCTIONED (WEATHER RADAR) · airframe 71,657 hrs · 12,376 cycles
RADAR SPIKES INTERMITTENTLY. OPS CHECK RADAR IAW AMM 34-43-00 AND FIM 34-43 FAULT TREE 805, NO FAULTS NOTED AT THIS TIME.
Part: NOT REPORTED — MALFUNCTIONED (WEATHER RADAR) · airframe 71,622 hrs · 12,365 cycles
INTERMITTENT RADAR SPIKES ON RADAR RETURNS. PERFORMED WX RADAR OPS TEST PER AMM 34-43-00. OPS TEST OK AT THIS TIME.
Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 71,622 hrs · 12,365 cycles
STATUS MESSAGE LEFT IDG VALVE. PERFORMED BITE TEST OF BPCU FOUND NO FAULT AND RESET BOX MESSAGE CLEARED IAW AMM 24-11-00.
Part: SWITCH — DEFECTIVE (COCKPIT) · airframe 71,615 hrs · 12,363 cycles
LEFT ENGINE OIL PRESSURE LIGHT INOP. INSPECTED L ENG OIL PRESS LIGHT LIGHTED PUSH BUTTON ASSY IAW SWPM 20-84-18. FOUND NR 1 & 2 SPRING LOADED CONTACTS TO BE WEAK, ALSO FOUND NR 2 CONTACT TO BE BROKEN OFF INSIDE BASE ASSY. CRIMPED NEW CONTACT AND WIRE IAW WDM 79-33-11, INSTALLED NEW BASE ASSY L474 IAW SWPM 20-84-18 LIGHT CHECKS GOOD.
Part: SENSOR — DEFECTIVE (AC BAY) · airframe 71,615 hrs · 12,363 cycles
RIGHT PACK INOP. R&R MIX MANIFOLD SENSOR IAW 21-61-02. OPS CHECK NORMAL AT THIS TIME.
Part: UNKNOWN — MALFUNCTIONED (FUEL SYSTEM) · airframe 71,606 hrs · 12,359 cycles
INFLIGHT CTR RT FUEL PUMP EICAS MSG DID NOT ANNUNCIATE/DISPLAY EVEN WHEN THE CENTER FUEL TANK WAS DOWN TO 0.0 QUANTITY, NO PRESS LIGHT ON THE SWITCH LIGHT EITHER. T/S PER FIM 28-22 COULD NOT DUPLICATE ON GROUND.
Part: PUMP — FAULTY (FUEL SYSTEM) · airframe 71,606 hrs · 12,359 cycles
CTR LEFT & CTR RIGHT FUEL PUMP PRESS LIGHT CHECKS ON AND OFF WITH 0.7 IND IN CTR TANKFUEL. RIGHT CTR FUEL PUMP OPS CHECK NORMAL IAW AMM 28-42-01 LT CTR FUEL PUMP TRANSFERRED TO MDDR 100526 PER MEL 28-22-02A CAT C DUE DATE 12 OCT 18 PLACARD INSTALLED M PROCEDURES. C/W DISPATCH EH 0506Z. OPS CKS GOOD.
Part: TRU — FAULTY (APU) · airframe 71,602 hrs · 12,358 cycles
APU FAIL TO START AFTER LANDING. R&R APU TRU IAW AMM 24-32-04, OPS CKD GOOD.
Part: STATUS MESSAGE — FALSE ACTIVATION (COCKPIT) · airframe 71,564 hrs · 12,345 cycles
LT IDG VALVE STATUS MESSAGE. UPON INSPECTION NO MSG FOUND, CHECK CIRCUIT BREAKER AND FOLLOWED MAINT PROCEDURE PER FIM 24-11-00. OPS CHECK GOOD, NO STATUS MSG. A/C IN NORMAL CONDITION AL TIHIS TIME.
Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 71,577 hrs · 12,350 cycles
STATUS MSG LT IDG VALVE. T/S PER FIM 24-20 FT 802 , NO FAULTS NOTED, CLEANED CONNECTOR D11046. BIT BPCU PER FIM MSG CLEARED. RUN L ENGINE AND FAULT COULD NOT BE DUPLICATED REF AMM 71-00-00.
Part: SENSOR — FAULTY (AC BAY) · airframe 71,555 hrs · 12,342 cycles
RT PACK AUTO SHUT DOWN (WILL WORK IN STANDBY). R&R RT COMPRESSOR TEMP SENSOR TS42 IAW AMM 21-51-06 OPS CHECK AND SATISFACTORY BITE AT PACK CONTROLLER ALL OK.
Part: CONNECTOR — DIRTY (AC BAY) · airframe 71,555 hrs · 12,342 cycles
RT PACK TEMP CAUTION AFTER LANDING. PERFORMED BITE CHECK IAW 21-51-14. FOUND COMPRESSOR OUTLET FAULT, CHECKED SENSOR. REMOVED CONNECTOR AND CLEANED/RE-SECURED IAW AMM 21-52-01, CLEARED FAULT. FAULT DID NOT RETURN.