N166SY

EMBRAER S A ERJ 170-200 LR · 2016 · Fixed-wing multi-engine · 2 engines · 88 seats · Valid Registration

Registered owner: SKYWEST AIRLINES INC, UT (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

21 reports on file, 2021-12-16 – 2026-10-12.

OTHER · 2026-10-12 Matched by certificate designator
ATA 2565

Part: BUSTLE — BROKEN (ZONE 800 SLIDE) · airframe 24,975 hrs · 15,087 cycles

DURING REMOVAL OF LH FWD EMERGENCY EVACUATION SLIDE, LH FWD DOOR BUSTLE SLIDING TAB SNAPPED OFF OF BUSTLE. REMOVED AND REPLACED LT FWD DOOR BUSTLE IAW AMM 25-23-04.

Source: SDR SWIA2026101277603
Earlier reports · 2021–2024 · 20 reports

2024

OTHER · 2024-12-02 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (ZONE 200) · airframe 20,478 hrs · 12,210 cycles

DURING FINAL MAINTENANCE, ADDITIONAL CORROSION FOUND ON THE RH SEAT TRACK BETWEEN FR 83 - 84 (C-CHECK RO 12/8/2024) PERFORMED SPLICE REPAIR ON RH I/B SEAT TRACK BETWEEN FRAMES 82 - 84 REF EMB ETD2022-170-022163 REV: B. SEE CONTINUATION CARD FOR WORK DETAILS. NO SPECIFIC OR ADDITIONAL INSPECTIONS ARE NECESSARY.NO WEIGHT AND BALANCE ADJUSTMENT REQUIRED, REPAIR PARTS WEIGHED LESS THAN 2.5LBS.

Source: SDR SWIA2024120901320
OTHER · 2024-11-16 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (ZONE 200) · airframe 20,478 hrs · 12,210 cycles

R/H LATERAL SEAT TRACK GOUGED / CORRODED AT FR 74, 75, 76, 77, 78, 789, 80, 81, 82,AND FR 84 (C-CHECK RO 12/8/2024) REMOVED AND REPLACED R/H LATERAL SEAT TRACK BETWEEN FR 73-84. REF: SRM 51-40-08.O.E.M. PART INSTALLED NO CHANGE TO WEIGHT AND BALANCE SEE CONTINUATION CARD FOR WORK PERFORMED

Source: SDR SWIA202412091116
WARNING INDICATION · 2024-07-11 Matched by certificate designator
ATA 3240

Part: BRAKE — FAILED (PARKING) · airframe 19,722 hrs · 11,690 cycles

DUE TO PRKG BRK NO RELEASED EICAS MESSAGE REPORTED IN FLIGHT TROUBLE SHOOT AND REPAIR SYSTEM AT NEXT MAINTENANCE OVERNIGHT.MCI TYPE: SERVICEABLE / NEEDS ATTENTION (FLIGHT 4672 - FILED CLOSED) JUL 11, 2024 STATION: ONT--CMC CODES NOTED : 32400015UT1 / 32400016UT1 COMPLIED WITH FIM TASK32-41-00-810-853-A00, INITIAL EVALUATION, FAULT ISOLATION PROCEDURE BLK 1. FOUND TO TRANSITORY CONDITION OF GENERIC I/O MODULE 1. FAULT MESSAGE CLEARED. AIRCRAFT OK FOR CONTINUED SERVICE.

Source: SDR SWIA202407120011

2021

OTHER · 2021-12-20 Matched by certificate designator
ATA 5300

Part: NONE — CRACKED · airframe 13,775 hrs · 7,739 cycles

LATE FIND-FR52 LH SIDE OF LOWER FUSELAGE FWD SIDE OF FRAME ATTACH ANGLE CRACKED AS MARKED (C-CHECK RO 1/3/2022) REMOVED AND REPLACED -FR52 LH SIDE OF LOWER FUSELAGE FWD SIDE OF FRAME ATTACH ANGLE REF EMB SRM 51-40-08

Source: SDR SWIA202163553
OTHER · 2021-12-19 Matched by certificate designator
ATA 5512

Part: SKIN — DAMAGED (HORIZONTAL STAB) · airframe 13,775 hrs · 7,739 cycles

HORIZONTAL STAB. RH L/E 341AR HAS MULTIPLE NICKS WITH HIGH METAL. (C-CHECK RO 1/3/2022) BLENDED SMOOTH MULTIPLE NICKS WITH HIGH METAL. NOMINAL THICKNESS IS .110", DEEPEST BLENDOUT OF MATERAIL REMOVED IS .011", REMAINING MATERIAL THICKNESS IN THIS AREA IS .099". WORKED AREA IS WITHIN ALLOWABLE LIMITS PER ETD2021-170-043325. RESTORED SURFACE PROTECTION AS REQUIRED. INSPECTION REQUIREMNTS: EXTERNAL DET, THRESHOLD OF OF 7500FC, INTERNAL OF 7500FC LOOKING FOR CORROSION AND CRACKS, EXTERNAL ULTRA SONIC ON ERODED AREAS FOR CHECK REMAINING THICKNESS, THRESHOLD OF 7500FC, INTERVAL OF 7500FC. THIS IS AN ADDITIONAL AND SPECIFIC INSPECTION REQUIREMENT. IT REPRESENTS THE REPAIR AIRWORTHINESS LIMITATION, HOWEVER, IT DOES NOT DISMISS ANY OTHER EXISTING MAINTENANCE TASK. THRESHOLD IS COUNTED SINCE THE REPAIR ACCOMPLISHMENT. REF ETD2021-170-043325. SEE CONTINUATION CARD FOR ACCOMPLISHED

Source: SDR SWIA2022010563543
OTHER · 2021-12-19 Matched by certificate designator
ATA 5552

Part: NONE — WORN · airframe 13,775 hrs · 7,739 cycles

L/H ELEVATOR AT #1 AND #2 HINGE POSITION, ELEVATOR HINGE ATTACHING HARDWARE WORN (BOLT AND FLOATING BUSHING) (C-CHECK RO 1/3/2022) REMOVED AND REPLACED ATTACHING HARDWARE ON L/H ELEVATOR AT #1 AND #2 HINGE POSITION (BOLT AND FLOATING BUSHING) REF. AMM 27-31-05. REF CP 24004181 FOR FINAL INSTALL

Source: SDR SWIA202163557
OTHER · 2021-12-19 Matched by certificate designator
ATA 5552

Part: NONE — WORN · airframe 13,775 hrs · 7,739 cycles

R/H ELEVATOR AT #1 AND #2 HINGE POSITION, ELEVATOR HINGE ATTACHING HARDWARE WORN (BOLTS AND FLOATING BUSHINGS) (C-CHECK RO 1/3/2022) REMOVED AND REPLACED R/H ELEVATOR AT #1 AND #2 HINGE POSITION, ELEVATOR HINGE ATTACHING HARDWARE. (BOLTS AND FLOATING BUSHINGS) REF. AMM 27-31-05.

Source: SDR SWIA202163558
OTHER · 2021-12-19 Matched by certificate designator
ATA 5552

Part: NONE — CORRODED · airframe 13,775 hrs · 7,739 cycles

R/H ELEVATOR AT #3 HINGE POSITION, ELEVATOR AND ACTUATOR ATTACHING HARDWARE WORN (BOLTS) AND CORRODED (FLOATING BUSHINGS) (C-CHECK RO 1/3/2022) REMOVED AND REPLACED ELEVATOR AND ACTUATOR ATTACHING HARDWARE (BOLTS) AND (FLOATING BUSHINGS) REF AMM 27-31-05

Source: SDR SWIA202163552
OTHER · 2021-12-19 Matched by certificate designator
ATA 5552

Part: NONE — CORRODED · airframe 13,775 hrs · 7,739 cycles

L/H ELEVATOR AT #3 HINGE POSITION, ELEVATOR HINGE AND ACTUATOR ATTACHING HARDWARE WORN (BOLTS) AND CORRODED (FLOATING BUSHING) (C-CHECK RO 1/3/2022) REMOVED AND REPLACED ATTACHING HAREWARE ON L/H ELEVATOR AT #3 HINGE POSITION (FLOATING BUSHING) REF. AMM 27-31-05. REF CP 24004181 FOR FINAL INSTALL

Source: SDR SWIA202163551
OTHER · 2021-12-17 Matched by certificate designator
ATA 5300

Part: NONE — CORRODED · airframe 13,775 hrs · 7,739 cycles

R/H O/B PANEL SUPPORT AT FR 84 HAS CORROSION AS MARKED. (C-CHECK RO 1/3/2022) REMOVED AND REPLACED R/H O/B PANEL SUPPORT AT FR 84 REF EMB SRM 51-40-08. SEE CONTINUATION CARD FOR WORK ACCOMPLISHED

Source: SDR SWIA202163550
OTHER · 2021-12-16 Matched by certificate designator
ATA 5300

Part: NONE — FAILED · airframe 13,775 hrs · 7,739 cycles

L/H ELEVATOR INBD PCU FAILED BACKLASH FAILED BACKLASH FUNCTIONAL TEST (C-CHECK RO 1/3/2022) / REMOVED AND REPLACED HARDWARE FOR THE LH INBD ELEVATOR PCU. REF E-175 AMM 27-32-02. TORQUE WRENCH: ASSET 61343, CAL DUE 02-03-22. PERFORMED BACKLASH CHECK OF THE LH INBD ELEVATOR PCU. BACKLASH CHECK GOOD AT THIS TIME. FINAL BACKLASH VALUE .287 MM. REF E-175 AMM 27-30-00.

Source: SDR SWIA202163554
OTHER · 2021-12-16 Matched by certificate designator
ATA 5322

Part: NONE — CORRODED · airframe 13,775 hrs · 7,739 cycles

PAX FLOOR SHEAR PLATE CORRODED AT FRAME 19 BETWEEN AISLE AND FWD PAX DOOR. (C-CHECK RO 1/3/2022) REMOVED AND REPLACED PAX FLOOR SHEAR PLATE BETWEEN FR 19-20. REF EMB SRM 51-40-08. SEE CONTINUATION FOR WORK PERFORMED.

Source: SDR SWIA202163548
OTHER · 2021-12-16 Matched by certificate designator
ATA 5313

Part: NONE — CORRODED · airframe 13,775 hrs · 7,739 cycles

PAX FLOOR SHEAR PLATE CORRODED AT FRAME 14 NEAR SERVICE DOOR. (C-CHECK RO 1/3/2022) REMOVED AND REPLACED PAX FLOOR SHEAR PLATE AT FRAME 14 NEAR SERVICE DOOR. REF SRM 51-40-08

Source: SDR SWIA202163546
OTHER · 2021-12-16 Matched by certificate designator
ATA 5311

Part: NONE — CORRODED · airframe 13,775 hrs · 7,739 cycles

R/H I/B SPLICE AT FR-89 HAS CORROSION AS MARKED. (C-CHECK RO 1/3/2022) REMOVED AND REPLACED R/H I/B SPLICE AT FR-89 REF EMB SRM 51-40-08 SEE CONTINUATION CARD FOR WORK ACCOMPLISHED

Source: SDR SWIA202163545
OTHER · 2021-12-16 Matched by certificate designator
ATA 5346

Part: NONE — CORRODED · airframe 13,775 hrs · 7,739 cycles

R/H I/B SEAT TRACK BETWEEN FR 31-32 HAS CORROSION AS MARKED. (C-CHECK RO 1/3/2022) REMOVED AND REPLACED OUT OF LIMITS R/H I/B SEAT TRACK BETWEEN FR 23-34 WITH NEW SEAT-TRACKAS REQUIRED REF SRM 51-40-08

Source: SDR SWIA202163542
OTHER · 2021-12-16 Matched by certificate designator
ATA 5322

Part: NONE — CORRODED · airframe 13,775 hrs · 7,739 cycles

PAX FLOOR SHEAR PLATE CORRODED AT FRAME 17 NEAR SERVICE DOOR. (C-CHECK RO 1/3/2022) REMOVED AND REPLACED PAX FLOOR SHEAR PLATE AT FRAME 17 NEAR SERVICE DOOR REF EMB SRM 51-40-02,51-40-08. RESTORED SURFACE PROTECTION REF EMB SRM 51-23-06. APPLIED CIC REF CPM 51-25-00

Source: SDR SWIA202163547
OTHER · 2021-12-16 Matched by certificate designator
ATA 5300

Part: NONE — FAILED · airframe 13,775 hrs · 7,739 cycles

L/H ELEVATOR OTBD PCU FAILED BACKLASH FAILED BACKLASH FUNCTIONAL TEST (C-CHECK RO 1/3/2022) REMOVED AND REPLACED HARDWARE, BOLT AND BUSHING, FOR THE LH ELEVATOR OTBD PCU. REF E-175 AMM 27-32-02. TORQUE WRENCH ASSET 61343, CAL DUE 02-03-22. PERFORMED BACKLASH CHECK OF THE LH ELEVATOR OTBD PCU. BACKLASH CHECKED GOOD AT THIS TIME. FINAL BACKLASH VALUE .430 MM. REF E-175 AMM 27-30-00.

Source: SDR SWIA202163555
OTHER · 2021-12-16 Matched by certificate designator
ATA 5300

Part: NONE — CORRODED · airframe 13,775 hrs · 7,739 cycles

R/H O/B CROSS BEAM DOUBLER PLATE FR87-FR88 HAS CORROSION AS MARKED. (C-CHECK RO 1/3/2022) REMOVED AND REPLACED R/H O/B CROSS BEAM DOUBLER PLATE FR87-FR88 REF EMB SRM 51-40-08 SEE CONTINUATION CARD FOR WORK ACCOMLPISHED

Source: SDR SWIA202163544
OTHER · 2021-12-16 Matched by certificate designator
ATA 5322

Part: NONE — CORRODED · airframe 13,775 hrs · 7,739 cycles

PAX FLOOR, MILLED FITTING CORRODED JUST AFT OF PAX DOOR BETWEEN FRAMES 19-20. (C-CHECK RO 1/3/2022) REMOVED AND REPLACED PAX FLOOR, MILLED FITTING AFT OF PAX DOOR BETWEEN FRAMES 19-20 REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-04, 51-23-05, AND 51-23-06. APPLIED CORROSION INHIBITING COMPOUND REF CPM 51-25-00-910-001-A.

Source: SDR SWIA202163549
OTHER · 2021-12-16 Matched by certificate designator
ATA 5300

Part: NONE — FAILED · airframe 13,775 hrs · 7,739 cycles

R/H ELEVATOR INBD PCU FAILED BACKLASH FAILED BACKLASH FUNCTIONAL TEST (C-CHECK RO 1/3/2022) REMOVED AND REPLACED RH INBOARD PCU TO ELEVATOR HINGE HARDWARE. REF AMM 27-32-02. TW #TC2-61343 DUE 2-3-22. TW#TC2-8951 DUE 10-26-22.RE-CHECK OF BACKLASH ON RH ELEVATOR INBD PCU GOOD AT THIS TIME. FINAL BACKLASH RESULT IS .155 MM. REF AMM 27-30-00

Source: SDR SWIA202163556