N16919

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

74 reports on file, 2001-04-06 – 2018-06-07.

WARNING INDICATION · 2018-06-07 Matched by certificate designator
ATA 7510

Part: WARNING MESSAGE — ACTIVATED (ANTI ICE) · airframe 39,776 hrs · 30,607 cycles

CLIMBING THRU FL180, IN ICING CONDITIONS, THE ANTI ICE CAME ON THEN THE NR 2 OIL TEMP WENT TO 147C, BROUGHT THRUST LEVER BACK TO IDLE AND TEMP WENT TO 156 C. STARTED DECENT BACK TO DEPARTURE, LEFT ICING CONDITIONS. THE ANTI TURNED OFF AND THE RIGHT OIL TEMP WENT BACK TO NORMAL. DECLARED AN EMERGENCY AND LANDED WITHOUT FURTHER EVENT. MAINTENANCE PERFORMED FIM 79-37-00-810-806, AND PERFORMED ENGINE RUNS IAW AMM 72-00-00, NO FAULTS FOUND. ACFT OK FOR SERVICE. AIRCRAFT WAS THEN TAKEN UP ON A FUNCTIONAL CHECK FLIGHT TO FURTHER VERIFY OPERATION. NO DEFECTS WERE NOTED. AIRCRAFT WAS RETURNED TO SERVICE. AIRCRAFT HAS FLOWN 11 FLIGHTS SINCE THE EVENT WITH NO FURTHER OIL TEMPERATURE ISSUES.

Source: SDR FJTA201806129191
Earlier reports · 2001–2016 · 73 reports

2016

SMOKE/FUMES/ODORS/SPARKS · 2016-11-20 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (UNKNOWN) · airframe 37,710 hrs · 29,080 cycles

PILOT REPORTED A STRONG FUEL ODOR AFTER LANDING. MX PERFORMED INSPECTION OF BOTH ENGINES AND APU WITH NO LEAKS FOUND. ENGINE GROUND RUNS PERFORMED AND NO FUEL ODOR NOTED. ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA201611205088

2015

FLUID LOSS; SMOKE/FUMES/ODORS/SPARKS · 2015-06-03 Matched by certificate designator
ATA 7261

Part: OIL SYSTEM — LEAKING (ENGINE) · airframe 34,485 hrs · 26,458 cycles

ACFT WAS FERRIED HERE, BECAUSE OF A SMOKING ENGINE AND ODORS IN CABIN. INSPECTION BOROSCOPE THE ENGINE AND FOUND OIL BUILDING UP BEHIND THE IGV'S. MAINTENANCE R & R THE ENGINE AND OPS CHECK; LEAKS CHECKS WERE GOOD AND WILL BE RELEASED AT THE END OF THESE CHECKS.

Source: SDR ASOA20150603019
FLT CONT AFFECTED; WARNING INDICATION · 2015-04-12 Matched by certificate designator
ATA 2797

Part: CONNECTOR — DAMAGED (SPOILERS) · airframe 34,140 hrs · 26,183 cycles

FLIGHT 4263, SPOILER FAIL INFLIGHT AT FL370, SPOILERS OPEN INDICATION DISPLAYED ON EICAS. MAINTENANCE FOUND DAMAGED HARNESS AND PINS AT CONNECTOR P1166 FOR THE RT SPEED BRAKE PROXIMITY SWITCH. REMOVED DAMAGE SECTION AND REPAIRED IAW EMB-145 SWPM 20-21-00. R & R CONNECTOR PLUG, P1166 IAW SWPM 20-50-01. SPOILER SYSTEM OPS CHECK GOOD IAW AMM 27-63-01. OPS CHECK GOOD. NO OTHER DEFECTS NOTED AT THIS TIME. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20150412093
FLT CONT AFFECTED · 2015-03-27 Matched by certificate designator
ATA 2700

Part: ACTUATOR — FAULTY · airframe 34,055 hrs · 26,113 cycles

THE CREW REPORTED YAW TRIM SELF ACTUATES BOTH RT AND LT AT RANDOM. MAINTENANCE REPLACED YAW TRIM ACTUATOR. OPS CHECKS WERE GOOD.

Source: SDR ASOA20150327021

2014

SMOKE/FUMES/ODORS/SPARKS · 2014-10-28 Matched by certificate designator
ATA 3320

Part: BULB — SHORTED (CABIN LIGHTS) · airframe 33,108 hrs · 25,355 cycles

THE CREW REPORTED A STRONG BURNING ELECTRICAL ODOR IN THE VICINITY OF ROW 22. THE ACFT LANDED WITHOUT INCIDENT WHERE MAINTENANCE R & R A SHORTED LIGHT BULB AT ROW 22, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20141028129
OTHER · 2014-07-24 Matched by certificate designator
ATA 5320

Part: DOOR SILL — CORRODED (FRAMES 20-22) · corrosion level 2 · airframe 32,446 hrs · 24,826 cycles

DURING C-CHECK, THE SERVICE DOOR CENTER SILL WAS FOUND TO BE CORRODED. MAINTENANCE R & R THE SILL IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20140724230
OTHER · 2014-07-24 Matched by certificate designator
ATA 5510

Part: BRACKET — WORN (HORIZONTAL STAB) · airframe 32,446 hrs · 24,826 cycles

DURING C-CHECK, THE HORIZONTAL STABILIZER ACTUATOR UPPER MOUNT BRACKET WAS FOUND TO BE WORN AND WOULD NOT RETAIN THE HAT BUSHINGS. MAINTENANCE R & R THE BRACKET IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20140724231
OTHER · 2014-07-24 Matched by certificate designator
ATA 5510

Part: FITTING — WORN (HORIZONTAL STAB) · airframe 32,446 hrs · 24,826 cycles

DURING C-CHECK, THE LT AND RT HORIZONTAL STABILIZER HINGE PIN FITTINGS WERE FOUND TO BE WORN AND WOULD NOT RETAIN THE BUSHINGS. MAINTENANCE PERFORMED A REAMING REPAIR TO THE FIRST OVERSIZE IAW SRM 55-10-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20140724229V
OTHER · 2014-07-24 Matched by certificate designator
ATA 5242

Part: SKIN — CRACKED (E/E BAY DOOR) · airframe 32,446 hrs · 24,826 cycles

DURING C-CHECK, THE REAR E/E BAY DOOR INNER SKIN WAS FOUND TO BE CRACKED. MAINTENANCE PERFORMED A DOUBLER REPAIR IAW EC5240-01082. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20140724232

2013

NO TEST · 2013-09-19 Matched by certificate designator
ATA 2560

Part: BATTERY PACK — INOPERATIVE (FLASHLIGHT) · airframe 30,380 hrs · 23,250 cycles

DURING MX INSPECTION, AFT CABIN FLASHLIGHT FOUND INOPERATIVE. MX R & R FLASHLIGHT BATTERY. OPS CHECKED GOOD. ACFT APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20130919111

2012

NO TEST · 2012-12-12 Matched by certificate designator
ATA 3350

Part: CHARGER — INOPERATIVE (EMERGENCY LIGHTS) · airframe 28,327 hrs · 21,615 cycles

DURING MX INSPECTION THE LT AND RT OVERWING EMERGENCY LIGHTS WERE FOUND INOPERATIVE. MX R & R NR 4 EMERGENCY LIGHT BATTERY CHARGER WITH OPERATIONAL CHECKS SUCCESSFUL. ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20121212114R
NO TEST · 2012-10-23 Matched by certificate designator
ATA 3350

Part: INVERTER — INOPERATIVE (EMERGENCY LIGHTS) · airframe 27,977 hrs · 21,346 cycles

DURING PREFLIGHT INSPECTION, THE CREW REPORTED THAT THE FIRST AISLE PATH EMERGENCY LIGHT WOULD NOT ILLUMINATE. MX R & R THE NR 1 EMERGENCY LIGHT INVERTER OPS TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20121023134
OTHER · 2012-08-30 Matched by certificate designator
ATA 5320

Part: FLOOR SUPPORT — CORRODED (ZONE 900) · corrosion level 2 · airframe 27,584 hrs · 21,020 cycles

DURING C-CHECK LT OMEGA BEAM FRAME 59 HAS CORROSION (LOCAL LEVEL 2) AT SIDE WALL TO LWR FLANGE. (CROSSBEAM ATTACHMENT POINT). MX PERFORMED REPAIR ON LT OMEGA BEAM, FRAME 59 (CROSSBEAM ATTACHMENT POINT IAW SRM 53-00-10. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20120830082
OTHER · 2012-08-30 Matched by certificate designator
ATA 5320

Part: FLOOR SUPPORT — CORRODED (ZONE 900) · corrosion level 2 · airframe 27,584 hrs · 21,020 cycles

DURING C-CHECK CENTER OMEGA BEAM FRAME 59 HAS CORROSION (LOCAL LEVEL 2) ON SIDEWALL UNDERNEATH FASTENER AT CROSSBEAM ATTACHMENT POINT. MX PERFORMED REPAIR BY INSTALLING FABRICATED REPAIR DOUBLER AT CENTER OMEGA BEAM AT FRAME 59 CROSSBEAM ATTACHMENT IAW SRM 53-00-10. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20120830083
OTHER · 2012-08-30 Matched by certificate designator
ATA 5320

Part: FLOOR SUPPORT — CORRODED (ZONE 100) · corrosion level 2 · airframe 27,584 hrs · 21,020 cycles

DURING LT OMEGA BEAM HAS CORROSION (LOCAL LEVEL 2) AT CROSSBEAM ATTACHMENT POINT LOWER FLANGE FRAME 54. MX PERFORMED AND COMPLETED REPAIR OF LT OMEGA BEAM FRAME 54 IAW SRM 53-00-10, FIG 202, SHEET 2. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20120830088V
OTHER · 2012-08-30 Matched by certificate designator
ATA 5300

Part: FLOOR SUPPORT — CORRODED (ZONE 100) · corrosion level 2 · airframe 27,584 hrs · 21,020 cycles

DURING C-CHECK CENTER OMEGA BEAM FRAME 29 HAS CORROSION (LOCAL LEVEL 2) AT LOWER FLANGE AND SIDEWALL FOR CROSSBEAM ATTACHMENT POINT. MX PERFORMED REPAIR ON CENTER OMEGA BEAM FRAME 29 CROSSBEAM ATTACHMENT POINT IAW SRM 53-00-10. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20120830085
OTHER · 2012-08-30 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (ZONE 100) · corrosion level 2 · airframe 27,584 hrs · 21,020 cycles

DURING C-CHECK UNDER FLOOR SKIN BTWN FRAME 11 AND 12 STR 21R-20R HAS CORROSION (LOCAL LEVEL 2). MX PERFORMED REPAIR TO SKIN FRAME 11-12 STR 21R-20R IAW EC5320-01681. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20120830081V
OTHER · 2012-08-30 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (ZONE 100) · corrosion level 2 · airframe 27,584 hrs · 21,020 cycles

DURING C-CHECK PILOT INBD SEAT TRACK BUTTSTRAP CORRODED (LOCAL LEVEL 2). MX PERFORMED REPAIR TO PILOTS INBD BUTTSTRAP IAW EC5310-01623. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20120830080
OTHER · 2012-08-30 Matched by certificate designator
ATA 5320

Part: FLOOR SUPPORT — CORRODED (ZONE 100) · corrosion level 2 · airframe 27,584 hrs · 21,020 cycles

DURING C-CHECK CENTER OMEGA BEAM AT FRAME 44 LOWER CROSSBEAM ATTACHMENT POINT HAS CORROSION (LOCAL LEVEL 2). MX PERFORMED AND COMPLETED REPAIR OF CENTER OMEGA BEAM AT FRAME 44 LOWER CROSSBEAM ATTACHMENT POINT IAW EC5310-01466. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20120830089
OTHER · 2012-08-30 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (ZONE 200) · airframe 27,584 hrs · 21,020 cycles

DURING C-CHECK, CRACK AROUND RIVET FRAME 75, STRINGER 2L-3L VERIFIED WITH EDDY CURRENT. MX PERFORMED REPAIR BY INSTALLING FABRICATED REPAIR DOUBLER AND FILLER AT FRAME 75 BETWEEN STRINGER 2L-3L IAW EC5330-02313. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20120830090
OTHER · 2012-08-30 Matched by certificate designator
ATA 5320

Part: FLOOR SUPPORT — CORRODED (ZONE 100) · corrosion level 2 · airframe 27,584 hrs · 21,020 cycles

DURING C-CHECK CENTER OMEGA BEAM FRAME 32 HAS CORROSION AT BOTH LWR FLANGE AND SIDEWALL FOR CROSSBEAM ATTACHMENT POINT. MX PERFORMED REPAIR ON CENTER OMEGA BEAM FRAME 32-34 LWR FLANGE AND SIDEWALL FOR CROSSBEAM ATTACHMENT POINT IAW SRM 53-00-10. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20120830086
OTHER · 2012-08-30 Matched by certificate designator
ATA 5320

Part: FLOOR SUPPORT — CORRODED (ZONE 100) · corrosion level 2 · airframe 27,584 hrs · 21,020 cycles

DURING C-CHECK LT OMEGA BEAM FRAME 29 HAS CORROSION (LOCAL LEVEL 2) AT CROSSBEAM ATTACHMENT POINT LWR FLANGE. MX PERFORMED REPAIR AND INSTALLED J-CHANNEL AT LT OMEGA BEAM FRAME 29 IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20120830084
OTHER · 2012-08-30 Matched by certificate designator
ATA 5320

Part: FLOOR SUPPORT — CORRODED (ZONE 100) · corrosion level 2 · airframe 27,584 hrs · 21,020 cycles

DURING C-CHECK CENTER OMEGA BEAM FRAME 38 HAS CORROSION (LOCAL LEVEL 2) AT CROSSBEAM ATTACHMENT POINT BOTH SIDEWALL AND LOWER FLANGE. MX PERFORMED REPAIR ON CENTER OMEGA BEAM AT FRAME 38 CROSSBEAM ATTACHMENT FLANGE IAW SRM 53-00-10. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20120830087
OTHER · 2012-08-30 Matched by certificate designator
ATA 5320

Part: STRUCTURE — CORRODED (ZONE 100) · corrosion level 2 · airframe 27,584 hrs · 21,020 cycles

DURING C-CHECK, CARGO DOOR LOWER CUTOUT STRUCTURE CORRODED (LOCAL LEVEL 2). MX R & R CARGO DOOR LOWER CUTOUT IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20120830091
OTHER · 2012-08-29 Matched by certificate designator
ATA 5743

Part: TRUNNION PIN — CRACKED (RT MLG) · airframe 27,584 hrs · 21,020 cycles

DURING C-CHECK, RT MLG AFT UPPER TRUNNION OTBD MATING SURFACE CRACKED. MX COMPLETED REPAIR OF AFT UPPER MLG TRUNNION IAW EC5750-01483. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20120829079V
NO TEST · 2012-04-18 Matched by certificate designator
ATA 3350

Part: INVERTER — INOPERATIVE (EMERGENCY LIGHTS) · airframe 26,930 hrs · 20,467 cycles

FLIGHT 6124, CREW RPORTED THE GALLEY EMERGENCY LIGHT TO BE INOPERATIVE. MX R & R THE AFFECTED LIGHT INVERTER, OPS TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR ASOA20120418062

2011

OTHER · 2011-12-16 Matched by certificate designator
ATA 2340

Part: HANDSET — FAULTY (CONTROL PANEL) · airframe 25,948 hrs · 19,689 cycles

THE CREW REPORTED THE F/A'S EMERGENCY CALL SWITCH LIGHT WILL NOT EXTINGUISH. MX REPLACED THE FORWARD F/A'S HANDSET. OPS CHECKED GOOD.

Source: SDR ASOA20111216022
NO TEST · 2011-09-09 Unresolved
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 25,267 hrs · 19,166 cycles

IAH - DURING MAINTENANCE INSPECTION THE EMERGENCY EXIT LIGHTS AT SIDE DOORS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER THREE EMERGENCY LIGHT BATTERY PACK, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA11IA204
OTHER · 2011-04-10 Unresolved
ATA 2397

Part: WIRE — DEFECTIVE (NR 1 COMM) · airframe 24,283 hrs · 18,443 cycles

CLE FLT 2866 THE CREW REPORTED A COMM 1 STUCK MIC ON TRANSMIT. THE AIRCRAFT RETURNED TO CLE AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND REPLACED WIRE W101-3092-24 AND W101-3094-24 AND WIRE SPLICE 2020. OPERATIONAL CHECKS WERE GOOD.

Source: SDR C2XA11CL092
OTHER · 2011-01-19 Unresolved
ATA 2132

Part: MODULE — ERRATIC (CABIN PRESSURE) · airframe 23,801 hrs · 18,086 cycles

CLE FLT 2864 THE CREW REPORTED DURING CRUISE (FL200) THE CABIN ALTITUDE WAS REACHING 8300FT. MAINTENANCE INSPECTED AND REPLACED THE CABIN PRESSURE ACQUISITION UNIT. OPERATIONAL CHECKS WERE GOOD.

Source: SDR C2XA11CL018

2010

NO TEST · 2010-08-18 Unresolved
ATA 2611

Part: SMOKE DETECTOR — FAILED (CARGO BAY) · airframe 22,796 hrs · 17,310 cycles

IAH - FLIGHT 2435, THE CREW REPORTED THAT THE BAGGAGE SMOKE DETECTOR FAILED ON TEST. MAINTENANCE INSPECTED THE AIRCRAFT AND REMOVED AND REPLACED THE BAGGAGE COMPARTMENT FORWARD SMOKE DETECTOR, OPERATIONALLY TESTED WITH NO DEFECTS. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA10IA235
OTHER · 2010-07-26 Unresolved
ATA 5320

Part: FLOOR SUPPORT — CORRODED (FUSELAGE) · corrosion level 2 · airframe 22,661 hrs · 17,213 cycles

CENTER OMEGA BEAM CORRODED AT FRAME 20 AT RAMP ANGLE. REMOVED AND REPLACED RAMP ANGLE IAW EMB 145 SRM 51-40-02, 51-20-03, 51-20-01, 51-30-01 AND CPM 51-21-07.

Source: SDR C2XA10TY103
WARNING INDICATION · 2010-02-11 Unresolved
ATA 2150

Part: SWITCH — INOPERATIVE (AC PACK) · airframe 21,554 hrs · 16,381 cycles

IAH - FLIGHT 2627 THE CREW PERFORMED AN AIR RETURN DUE TO PACK TWO OVERLOAD EICAS MESSAGE INTERMITTENTLY COMING ON. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE REMOVED AND REPLACED THE NUMBER TWO PACK TEMP SWITCH, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA10IA065

2009

OVER TEMP; WARNING INDICATION · 2009-12-26 Unresolved
ATA 7530

Part: CONTROL VALVE — DIRTY (NR 1 ENGINE) · airframe 21,263 hrs · 16,182 cycles

IAH - FLIGHT 2411, THE CREW REPORTED A ENGINE ONE EXCEEDANCE AT TOP OF CLIMB WITH THE THRUST LEVER IN DETENT ITT AMBER JUST ABOVE 900 DEGREES AND N2 AT ABOUT 101 PERCENT, THE ENGINE STABILIZED WITH REDUCED THRUST, AND THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE NUMBER 3 & 17 THERMOCOUPLES, AND REMOVED AND REPLACED THE COMPRESSOR ACCELERATION CONTROL VALVE, OPERATIONALLY AND LEAK CHECKED WITH NO DEFECTS NOTED, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA09IA326
OVER TEMP; WARNING INDICATION · 2009-12-26 Unresolved
ATA 7722

Part: THERMOCOUPLE — INOPERATIVE (NR 1 ENGINE) · airframe 21,263 hrs · 16,182 cycles

IAH - FLIGHT 2411, THE CREW REPORTED A ENGINE ONE EXCEEDANCE AT TOP OF CLIMB WITH THE THRUST LEVER IN DETENT ITT AMBER JUST ABOVE 900 DEGREES AND N2 AT ABOUT 101 PERCENT, THE ENGINE STABILIZED WITH REDUCED THRUST, AND THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE NUMBER 3 & 17 THERMOCOUPLES, AND REMOVED AND REPLACED THE COMPRESSOR ACCELERATION CONTROL VALVE, OPERATIONALLY AND LEAK CHECKED WITH NO DEFECTS NOTED, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA09IA325
WARNING INDICATION · 2009-12-03 Unresolved
ATA 3412

Part: SENSOR — INOPERATIVE (TAT) · airframe 21,118 hrs · 16,080 cycles

FLIGHT 2710 - EWR - FLIGHT CREW REPORTED THAT DURING CLIMBING TAT NR 1 FAIL MESSAGE IN EICAS. CREW PERFORMED AIR RETURN AND LANDED ACFT UNEVENTFULLY. EWR MX REMOVED AND REPLACED TAT NR 1 AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.

Source: SDR C2XA09RI202
NO TEST · 2009-09-01 Unresolved
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 20,514 hrs · 15,617 cycles

IAH - DURING MAINTENANCE INSPECTION THE NUMBER THREE EMERGENCY LIGHT BATTERY PACK WAS FOUND TO BE NOT HOLDING A CHARGE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BATTERY PACK, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA09IA220
NO TEST · 2009-09-01 Unresolved
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHTS) · airframe 20,514 hrs · 15,617 cycles

IAH - DURING MAINTENANCE INSPECTION THE NUMBER THREE EMERGENCY LIGHT BATTERY PACK WAS FOUND TO NOT HOLD A CHARGE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BATTERY PACK, OPERATIONALLY TESTED WITH NO DEFECTS. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA09IA020A
NO TEST · 2009-07-29 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 20,269 hrs · 15,438 cycles

EMERGENCY LIGHT OVER SEATS 12BC INOP. REMOVED AND REPLACED EMERGENCY LIGHT BULB. OPS CHECK GOOD AND AIRCRAFT RELEASED FOR SERVICE.

Source: SDR C2XA09TY192
NO TEST · 2009-06-15 Unresolved
ATA 3350

Part: INVERTER — INOPERATIVE (EMERGENCY LIGHTS) · airframe 19,959 hrs · 15,190 cycles

DURING ROUTINE MX, MX FOUND RT EMERGENCY EXIT MARKER INOPERATIVE. MX REMOVED AND REPLACED NR 5 EMERGENCY INVERTER AND PERFORMED OPS CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.

Source: SDR C2XA09RI125
WARNING INDICATION · 2009-03-08 Unresolved
ATA 3020

Part: ANTI-ICE VALVE — INOPERATIVE (NR 1 ENGINE) · airframe 19,317 hrs · 14,720 cycles

FLIGHT 3009 - EWR - FLIGHT CREW REPORTED NR 1 ENG ANTI-ICE OPEN INDICATION INOPERATIVE IN ICE CONDITION. EWR MX REMOVED AND REPLACED NR 1 ENGINE ANTI-ICE VALVE AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY. AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.

Source: SDR C2XA09RI038
OVER TEMP; WARNING INDICATION · 2009-02-18 Unresolved
ATA 2432

Part: BATTERY — OVERHEATED (NR 2) · airframe 19,198 hrs · 14,632 cycles

IAH - FLIGHT 2312, THE CREW REPORTED THAT THE NUMBER TWO MAIN BATTERY WAS OVERHEATING IN FLIGHT. THE CREW DEACTIVATED THE NUMBER TWO BATTERY, AND THE TEMPERATURE REMAINED CONSTANT UNTIL DESCENT. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE REMOVED AND REPLACED THE NUMBER TWO MAIN BATTERY, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA09IA054

2008

OTHER · 2008-12-24 Unresolved
ATA 2131

Part: CONTROLLER — FAULTY (CABIN PRESSURE) · airframe 18,868 hrs · 14,394 cycles

CLE FLIGHT 2150 - THE CREW REPORTED THE AIRCRAFT WOULD NOT PRESSURIZE ON CLIMBOUT. THE AIRCRAFT RETURNED TO CLE AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE DIGITAL CONTROLLER. OPERATIONAL CHECKS WERE GOOD.

Source: SDR C2XA08CL135
WARNING INDICATION · 2008-11-27 Unresolved
ATA 2621

Part: FIRE BOTTLE — FAULTY (NR 1 ENGINE) · airframe 18,726 hrs · 14,286 cycles

EWR - FLIGHT 2400 - THE CREW REPORTED A ENGINE 1/2 EXTBTL A INOP MESSAGE ON THE EICAS INFLIGHT. THE AIRCRAFT DIVERTED INTO CLE AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE ENGINE NR 1 FIRE BOTTLE A. OPERATIONAL CHECKS WERE GOOD.

Source: SDR C2XA08CL124
NO TEST · 2008-09-27 Unresolved
ATA 3350

Part: LIGHT — MALFUNCTIONED (CABIN) · airframe 18,350 hrs · 13,983 cycles

FLT 3077 - EWR - FLT CREW REPORTED EMERGENCY LIGHTS INOPERATIVE. EWR MX RESET EMERGENCY LIGHT SYSTEM AND PERFORMED OPS CHECK SUCCESSFULLY. AC WAS RETURNED TO SERVICE.

Source: SDR C2XA08RI150
OTHER · 2008-08-05 Unresolved
ATA 5210

Part: BUSHING — WORN (PAX DOOR)

CLE - FLIGHT 2552 THE CREW REPORTED, UNABLE TO OPEN THE MAIN CABIN DOOR FROM INSIDE. MAINTENANCE INSPECTED AND REPLACED THE FORWARD BUSHINGS ON THE LINK SUPPORT OF THE MAIN CABIN DOOR. THE MAIN DOOR CABLES WERE ALSO ADJUSTED AND OPERATIONAL CHECKS WERE GOOD. (S)

Source: SDR C2XA08CL094
OTHER · 2008-07-19 Unresolved
ATA 5755

Part: BRACKET — DAMAGED (RT WING SPOILER)

RT WINGS GROUND SPOILER OUTBOARD ATTACHMENT POINT HAS A MIGRATING HAT BUSHING. MX REMOVED AND REPLACED RT WING`S GROUND SPOILER OUTBOARD ATTACHMENT POINT IAW AMM 57-51-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE. (S)

Source: SDR C2XA08SH096
OTHER · 2008-07-11 Unresolved
ATA 5751

Part: BUSHING — MIGRATED (ATTACH FITTING) · airframe 17,834 hrs · 13,646 cycles

SHV - DURING C-CHECK BOTH HAT BUSHING ON RT AILERON DAMPER ATTACHMENT FITTING ON AILERON ARE MIGRATED. MX REMOVED AND REPLACED RT AILERON DAMPER ATTACHING FITTING IAW EMB 145-SRM-51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (A)

Source: SDR C2XA08SH094
OTHER · 2008-07-11 Unresolved
ATA 5751

Part: BUSHING — MIGRATED (BRACKET) · airframe 17,834 hrs · 13,646 cycles

SHV - DURING C-CHECK RT AILERON OUTBOARD CONTROL ROD ATTACHING BRACKET ON AILERON, HAS MIGRATED HAT BUSHING. MX REMOVED AND REPLACED RT AILERON OUTBOARD CONTROL ROD ATTACHING BRACKET IAW EC5750-01177. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (A)

Source: SDR C2XA08SH093
NO TEST · 2008-03-13 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 17,025 hrs · 13,081 cycles

TYS - DURING A OVERNIGHT A-CHECK THE AFT CEILING EMERGENCY LIGHT WAS FOUND INOP. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY LAMP IAW AMM 33-50-08. OPS CHECKS GOOD.

Source: SDR C2XA08TY035

2007

SMOKE/FUMES/ODORS/SPARKS · 2007-06-18 Unresolved
ATA 7532

Part: BLEED VALVE — STICKING (NR 2 ENGINE) · airframe 15,063 hrs · 11,651 cycles

MKE FLIGHT 2266, THE CREW REPORTED THE NR 2 HIGH STAGE BLEED VALVE C/B POPPED IN FLIGHT AND NOTICED A SMOKE SMELL IN THE CABIN. MAINTENANCE INSPECTED AND REPLACED THE NR 2 HIGH STAGE BLEED VALVE. ALSO REPLACED THE NR 2 HIGH STAGE VALVE PRESSURE SWITCH. OPERATIONAL CHECKS WERE GOOD.

Source: SDR C2XA07CL054

2006

ENGINE STOPPAGE · 2006-12-01 Unresolved
ATA 7200

Part: STATOR — SHORTED (NR 2 ENGINE) · airframe 13,667 hrs · 10,552 cycles

IAH - FLIGHT 2653, THE CREW REPORTED AN UNCOMMANED ENGINE 2 SHUTDOWN WITH FADEC 2A &2B CIRCUIT BREAKERS POPPING. THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED THE AIRCRAFT AND REMOVED AND REPLACED THE NR 2 ENGINE PMA STATOR, AND THE 2A & 2B FADECS AS A PRECAUTION. OPERATIONAL CHECKS PERFORMED WITHOUT DEFECT, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA06IA189
OTHER · 2006-08-20 Unresolved
ATA 5210

Part: DOOR — OUT OF RIG (MAIN PAX) · airframe 12,962 hrs · 9,986 cycles

IAH - FLIGHT 2287, THE CREW REPORTED THAT THE MAIN CABIN DOOR WAS GETTING JAMMED ON THE TOP AND BOTTOM. MAINTENANCE INSPECTED AND RIGGED THE DOOR, OPERATIONAL CHECKS WERE PERFORMED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA06IA133
OTHER · 2006-02-03 Unresolved
ATA 7320

Part: FADEC — FAULTY (NR 1 ENGINE) · airframe 11,629 hrs · 8,958 cycles

CLE FLIGHT 3203 THE CREW REPORTED NR 1 ENGINE SURGING ON FADEC 1B. MAINTENANCE INSPECTED AND REPLACED FADEC 1B. OPERATIONAL CHECKS WERE GOOD.

Source: SDR C2XA06CL018

2005

FLUID LOSS; WARNING INDICATION · 2005-12-20 Unresolved
ATA 2910

Part: O-RING — DAMAGED (NR 1 HYD MANFLD) · airframe 11,343 hrs · 8,729 cycles

FLIGHT 2334 EWR TO SDF, CREW REPORTED HYDRAULIC SYSTEM NR 1 FAILED IN FLIGHT. FLIGHT DIVERTED TO RIC. RIC MX FOUND THE CAUSE OF FLUID LOSS TO BE AT THE NR 1 HYD MANIFOLD, EDHP PRESSURE SWITCH. MX REMOVED AND REPLACED THE PRESSURE SWITCH O-RING AND DUE TO THE SYSTEM BEING RUN OUT OF FLUID ALSO REPLACED NR 1 EDHP AND NR 1 EMDP ALONG WITH DECONTAMINATING THE FLUID SYSTEM AND CHANGING NR 1 SYSTEM HYD FLUID FILTERS.

Source: SDR C2XA05RI019
WARNING INDICATION · 2005-10-21 Unresolved
ATA 3260

Part: SWITCH — INOPERATIVE (NLG) · airframe 10,933 hrs · 8,413 cycles

IAH - FLIGHT 2989, THE CREW REPORTED THAT THE NLG DOORS WOULD NOT CLOSE. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE REMOVED AND REPLACED THE NLG DOOR SEQUENCE PROXIMITY SWITCH, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA05IA119
OTHER · 2005-01-03 Unresolved
ATA 3350

Part: INVERTER — FAILED (EMERGENCY LIGHT) · airframe 8,956 hrs · 6,875 cycles

EWR - PILOT REPORTED OVERHEAD EMERGENCY EXIT LIGHT OVER ROW 12 OUT. MAINTENANCE REMOVED AND REPLACED NR 3 INVERTER IAW EMB 145 MM 33-50-11. OPS CHECK GOOD.

Source: SDR C2XA05BT002

2004

FALSE WARNING · 2004-10-26 Unresolved
ATA 2611

Part: SMOKE DETECTOR — DIRTY (LAVATORY) · airframe 8,500 hrs · 6,502 cycles

IAD - FLIGHT 3293 CREW REPORTED LAV SMOKE WARNING IN FLIGHT, NO SMOKE VISIBLE. CREW FOLLOWED QRH PROCEDURE. IAD MAINTENANCE CLEANED SMOKE DETECTOR SENSOR AND PERFORMED LAV SMOKE FIM TASK 26-14-00. ALL OPERATIONAL CHECKS WERE SATISFACTORY. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA04RI010
NO TEST · 2004-10-13 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 8,413 hrs · 6,430 cycles

DURING INSPECTION FOUND CENTER AISLE EMERGENCY LIGHT AT ROW 12 INOPERATIVE. REMOVED THE CENTER AISLE EMERGENCY LIGHT ASSY. OPS CHECK OK.

Source: SDR C2XA04BT108
OTHER · 2004-08-10 Unresolved
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 8,083 hrs · 6,174 cycles

SHV-DURING C-CHECK THE CENTER FLOORBEAM WAS FOUND TO BE CORRODED OUT OF LIMITS IAW SRM 53-21-10. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BEAM IAW SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA04SH480
NO TEST · 2004-07-31 Unresolved
ATA 3350

Part: LAMP — BURNED OUT (EMERGENCY LIGHT) · airframe 8,064 hrs · 6,157 cycles

NON-ROUTINE WORK CARD WRITE UP, NR 2 OVERWING EMERGENCY LIGHT INOP. REMOVED AND REPLACED NR 2 OVERWING EMERGENCY LIGHT IAW EMB 145 MM 33-50-07. OPS CHECK GOOD.

Source: SDR C2XA04BT082
OVER TEMP; WARNING INDICATION · 2004-06-13 Unresolved
ATA 2432

Part: BATTERY — OVERTEMP (MASTER)

THE CREW REPORTED A NUMBER TWO BATTERY OVERTEMP IN FLIGHT. THE AIRCRAFT DIVERTED TO EFD WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED BOTH AIRCRAFT BATTERIES, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA04IA065

2003

NO TEST · 2003-12-16 Unresolved
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT)

DURING ROUTINE MAINTENANCE THE EMERGENCY LIGHT AT ROW 12B/C WAS INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT BULB AT ROW 12 B/C. OPERATIONAL CHECKS WERE GOOD.

Source: SDR C2XA03CL199
NO TEST · 2003-06-23 Unresolved
ATA 3350

Part: INVERTER — INOPERATIVE (CABIN)

CLE FLIGHT 2058 THE CREW REPORTED DURING PREFLIGHT THE EMERGENCY EXIT LIGHT WAS INOPERATIVE AT ROW 12. MAINTENANCE REPLACED THE NR 6 INVERTER. OPERATIONAL CHECKS WERE GOOD.

Source: SDR C2XA03CL116
NO TEST · 2003-06-20 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

DURING ROUTINE MAINTENANCE NR 2 AND NR 3 EMERGENCY AISLE PATH LIGHTS WERE FOUND INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY AISLE PATH LIGHT STRIP. OPERATIONAL CHECKS WERE GOOD.

Source: SDR C2XA03CL115
NO TEST · 2003-05-20 Unresolved
ATA 3350

Part: FUSE — BLOWN (EMERGENCY LIGHT)

EWR---CO2196, CREW REPORTED, EMERGENCY EXIT LIGHT STRIP INOPERATIVE.....MAINTENANCE REMOVED AND REPLACED FUSES IN GALLEY EMERGENCY LIGHT BATTERY IAW EMB145 CMM #25-60-03 AND 33-50-00, OPS. CHECKED EMERGENCY LIGHT STRIP GOOD.

Source: SDR C2XA03BT059
OTHER · 2003-01-31 Unresolved
ATA 3350

Part: BULB — BLOWN (CABIN) · airframe 4,527 hrs · 3,362 cycles

TYS, During a scheduled inspection the first aisle emergency light was found inoperative. Maintenance removed and replaced the bulb. operiational checked good, aircraft released to service.

Source: SDR C2XA03TY013
WARNING INDICATION · 2003-01-10 Unresolved
ATA 3620

Part: SWITCH — DEFECTIVE (AFT WING TO FUSE)

CLE FLIGHT#2316 THE CREW REPORTED AFTER TAKEOFF A BLEED LEAK INDICATION OCCURED.THE CREW TURNED OFF THE #2ENGINE BLEED AND THE MESSAGE CLEARED.SHORTLY AFTER THE MESSAGE RETURNED AND THE CREW SHUTDOWN THE #2 ENGINE.THE AIRCRAFT LANDED WITHOUT FURTHER INCIDENT.MAINTENANCE INSPECTED AND REPLACED THE BLEED AIR THERMAL SWITCH SO220.OPERATIONAL CHECKS WERE GOOD.

Source: SDR C2XA03CL010

2002

OTHER · 2002-11-22 Unresolved
ATA 5300

Part: STRAP — CORRODED (CABIN) · corrosion level 2 · airframe 4,147 hrs · 3,051 cycles

SHV- DURING C CHECK BUTT STRAP BETWEEN FRAMES 15 AND 16 CENTERLINE WAS FOUND TO HAVE CORROSION. MAINTENANCE REMOVED DAMAGE AND PEFORMED A SPLICE REPAIR IAW EMB 145 SRM 53-21-10. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.

Source: SDR C2XA02SH130
OTHER · 2002-11-21 Unresolved
ATA 5330

Part: SKIN — DENTED (FUSELAGE) · airframe 4,147 hrs · 3,051 cycles

DURING C CHECK, A DENT WAS FOUND JUST AFT OF FRAME 12A BY STRINGER 18 LT. MAITENTANCE REPAIRED DENT IAW CONTINENTAL EXPRESS EC 5330-01206. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.

Source: SDR C2XA02SH129
WARNING INDICATION · 2002-09-19 Unresolved
ATA 7520

Part: BYPASS VALVE — INOPERATIVE (NR 1 PYLON)

IAH- FLIGHT 2908 NR 1 BLEED OVERTEMP WHILE CLIMBING THROUGH FL200 WHEN ENTERING ICING CONDITIONS QRH COMPLETED. MAINTENANCE REMOVED AND REPLACED NR 1 FAN AIR BYPASS VALVE, PERFORMED A OPERATIONAL CHECK, NO DEFECTS NOTED, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA02IA200

2001

SMOKE/FUMES/ODORS/SPARKS · 2001-06-13 Unresolved
ATA 2530

Part: RECEPTACLE — ODOR (COFFEMAKER) · airframe 856 hrs · 573 cycles

GSP---CO4088, CREW REPORTED LEFT HAND COFFEE RECEPTACLE GIVES OFF BURN SMELL. MAINTENANCE PLACED BOTH COFFEEMAKERS ON MEL AND RETURNED THE AIRCRAFT TO SERVICE.

Source: SDR C2XA01BT114
NO TEST · 2001-04-06 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

IAH-DURING A-CHECK, THE MECHANIC NOTED THE AISLE PATH LIGHTING AT SEAT 9A WAS INOPERATIVE. IAH-MAINTENANCE REMOVED AND REPLACED THE AISLE EMERGENCY LIGHT AT SEAT 9A AND THE OPERATIONAL CHECK OF THE EMERGENCY LIGHTING SYSTEM WAS SATISFACTORY. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.

Source: SDR C2XA01IA198