N17289
Registered owner: UNITED AIRLINES INC, IL (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
3 reports on file, 2024-10-15 – 2026-10-25.
Part: TRIM PANEL — UNSECURE (ZONE 200) · airframe 13,060 hrs · 4,443 cycles
PANEL FOR EMERGENCY EXIT LIGHTS KNOCKED LOOSE & HANGING AT SEAT 25C. FOUND TRIM FOR EMERGENCY LIGHT KNOCKED OFF SEAT. RESECURED TRIM.
Part: LAVATORY — DIRTY (ZONE 900) · airframe 8,144 hrs · 2,855 cycles
AFT LEFT LAV SPILLED SEWAGE-SMELLING LIQUID ON TAKEOFF. LAV CURRNT U/S. AFT FLOOR NEEDS CLEANING PERFORMED OPS CHECK OF TOILET AND SINK IN LAV D AS REQUIRED. VERIFIED NO LEAKS. CLEANERS SANITIZED AREA. OK FOR SERVICE.
Part: CIRCUIT BREAKER — TRIPPED (ZONE 200) · airframe 5,566 hrs · 1,973 cycles
CB FOR FWD GALLEY COFFEE MAKER POPPED WAS NOT IN USE MAKER NUMBE R 105REMOVED C/M 105 AND C/M 106. INSPECTED VISIBLE WIRING, CONNECTORS, GROUNDS FOR SHORTS OR DEFECTS, NONE NOTED. REMOVED POWER PANEL ASSY IN FWD GALLEY NEXT TO C/MAKERS. INSPECTED WIRING, CONNECTORS AND CLAPS FOR DAMAGE OR SHORTS, NO DEFECTS NOTED. REMOVED POWER PANEL NEXT TO FORWARD OVEN. INSPECTED WIRING, CONNECTOR AND GROUNDS. NO DEFECTS NOTED. OPERATED BOTH FORWARD OVENS FOR 20 MINUTES, NO DEFECTS. CONTINUED... RAN SEVERAL BREW CYCLES ON BOTH FWD C/MAKERS. NO DEFECTS. VERIFIED BOTH HOTPLATE DRAINS DRAIN PROPERLY. CREW REPORTED THAT INTO PBI THE PRIOR FLIGHT, THEY NOTICED AN ELECTRICAL SMELL BUT NO SMELL WAS IN GALLEY. SUSPECT POSSIBLE SHORT OR DEFECT BETWEEN FWD GALLEY POWER SOURCE AND THE 2 FORWARD GALLEY MODULES. NEEDS FURTHER TROUBLESHOOTING TO DETERMINE CAUSE. T/S PER WDM 25-31-11 AND CMM 25-31-147. FOUND LOOSE SCREWS ON TERMINAL LUGS OF CB101 AND CB102. TIGHTENED SCREWS. MEASURED CURRENT ON ALL 3 PHASES WITH CLAMP METER. MEASURED 0 AMPS WITH BOTH COFFEE MAKERS AT REST AND 6.6 AMPS FOR EACH COFFEE MAKERS WHEN THEY WERE BREWING. ISOLATED CIRCUIT BY PULLING CB C914 AND REMOVING GALLEY PWR IND LIGHT. MEGGED WIRES AT RECEPTACLES OF COFFEE MAKERS 105 & 106. EACH PHASES TO NEUTURAL AND GND & TO EACH OTHER. NON DEFECTS NOTED. RE-INSTALLED ALL BACK TO THEIR ORIGINAL POSIPOSITIONS. PERFORMED OPS CHECK OF COFFEE MAKERS 105 & 106 IAW AMM 25-32-01. OPS CHECK GOOD. CB102 AND CB103 REMAINED IN AFTER NUMUROUS TESTS.