N1731D

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

36 reports on file, 1995-01-25 – 2000-12-22.

SMOKE/FUMES/ODORS/SPARKS · 2000-12-22 Matched by certificate designator
ATA 3300

Part: SWITCH — UNSERVICEABLE (GALLEY) · airframe 62,027 hrs · 27,950 cycles

CABIN SMOKE FLT 1958 PBI-ATL A/C 731 12/22/00, 1958 12/22/00 ACFT 731 HAD SMOKE IN THE CABIN. THE SOURCE OFTHE SMOKE WAS A SHORTED DIMMER. DIMMER DAL PN 337201822. REPLACED DIMMER.

Source: SDR DLL10002506
NO TEST · 2000-12-21 Matched by certificate designator
ATA 2560

Part: FLASHLIGHT — INOPERATIVE (CABIN) · airframe 62,022 hrs · 27,946 cycles

ON LAYOVER FOUND EMERGENCY FLASH LIGHT AT 4L DOOR WILL NOT TEST._C/A REPLACED FLASHLIGHT

Source: SDR DLL10002497
OTHER · 2000-10-10 Matched by certificate designator
ATA 5312

Part: BULKHEAD — CRACKED (FUSELAGE) · airframe 61,466 hrs · 27,776 cycles

THE FS 1212 BULKHEAD WAS FOUND WITH A TYPICAL CRACK IN THE WEB AT RBL 6. THE CRACK IS TYPICAL OF LAC S/B 093-53-277 AND AD 2000-16-08. THE CRACK WAS ROUTED OUT AND REPAIRED WITH TWO ALUMINUM DOUBLERS PER THE LAC S/B AND ER/A 378870-14AD, REV A.

Source: SDR DLL10001968
OTHER · 2000-04-08 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (FUSELAGE) · airframe 59,730 hrs · 27,217 cycles

THE FUSELAGE SKIN AND FACTORY .020 THICK DOUBLER WERE FOUND CORRODED AT FS 1645 AT STRINGER 29. THE CORROSION WAS REMOVED WITH A 21 (LONGITUDINAL) X 4.4 (CIRCUMFERENTIAL) CUTOUT THROUGH THE SKIN AND DOUBLER. THE CUTOUT WAS REPAIRED WITH AN EXTERNAL ALUMINUM DOUBLER AND TRIPLER PER ER/A 369725-14, REV A.

Source: SDR DLL10000690
Earlier reports · 1995–1999 · 32 reports

1999

SMOKE/FUMES/ODORS/SPARKS; WARNING INDICATION · 1999-12-15 Matched by certificate designator
ATA 7261

Part: PUMP — WEAK (NR 1 ENGINE)

A/C RETURNED FROM FLIGHT WITH A NR 1 ENGINE VIBRATION. FOUND THAT ENGINE WAS HIDING OIL IN GEAR CASE RESULTING IN A VIBRATION AT HIGHER POWER SETTINGS. GROUND RAN ENGINE AT HIGHER POWER SETTINGS UNTIL OIL SCAVENGED FROM GEAR CASE AND DRAINED OFF EXCESS AS ENGINE WAS OVER SERVICED DUE TO HIDDEN OIL. ALSO, REPORTS OF SMOKE IN CABIN DUE TO OIL VAPOR IN CABIN FROM OVER SERVICED ENGINE. REPLACED ENGINE.

Source: SDR DLL10992759
SMOKE/FUMES/ODORS/SPARKS · 1999-11-28 Matched by certificate designator
ATA 3310

Part: LIGHT — FAILED (COCKPIT)

DURING PREFLIGHT, COCKPIT FILLED UP WITH SMOKE AND FUMES FROM CAPT FLOOD LIGHT. REMOVED AND REPLACED CAPT FLOOD LIGHT RHEOSTAT, GROUND TEST NML.

Source: SDR DLL10992615
OTHER · 1999-03-31 Matched by certificate designator
ATA 5220

Part: COUNTERBALANCE — FAILED (R4 DOOR)

A/C IS IN FOR LETTER CHECK, OPNS 52148 & 68115 BOTH PERTAINING TO INSPECTION AND OPERATION OF PASSENGER AND EMERGENCY DOORS. FOUND R4 DOOR WOULD NOT OPEN COMPLETELY. NON-ROUTINE CARD 160 WAS INITIATED. FURTHER EVALUATION FOUND FAILURE OF THE COUNTERBALANCE TO BE THE CAUSE. REPLACED SAME.

Source: SDR DLL10990715

1998

NO TEST · 1998-12-04 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOP (GALLEY)

DURING LAYOVER, EMERGENCY CEILING LIGHTS BY L2/R2 INOP. POWER SUPPLY DOES NOT CHARGE. REPLACED POWER SUPPLY.

Source: SDR DLL10982496
NO TEST · 1998-06-23 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (CABIN)

EMERGENCY LIGHTS AT L2 R2 X-AISLE INOP. REPAIRED BROKEN WIRE AND OPS NORMAL.

Source: SDR DLL10981329
OTHER · 1998-04-03 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (FS 328)

AT HMV, FS 328 BLKHD EXTRNL SKIN DOUBLERS WERE FOUND CORRODED BETWEEN THE FUSE SKIN AND SKIN DOUBLER. ADDITIONAL INSPECTION FOUND TWO CRACKS IN THE FUSE SKIN AND ORIGNAL INTERNAL DOUBLER. REPAIRED PER ERA 331542-14AD.

Source: SDR DLL10980758
OTHER · 1998-04-03 Matched by certificate designator
ATA 5712

Part: RIB — CRACKED (WS 529)

RT WING IWS 529 RIB, UPPER CAP WAS FOUND CRACKED. PART REPLACED PER ERA 331467-14.

Source: SDR DLL10980752
OTHER · 1998-04-03 Matched by certificate designator
ATA 3221

Part: FITTING — CRACKED (BS 449)

DURING RTN INSPECTION OF THE FS 449 BLKHD WALL, TYP DAMAGE WAS FOUND TO THE RT NLG TRUNNION FITTING. REPAIRED PER ERA 331464-14AD.

Source: SDR DLL10980761
OTHER · 1998-04-03 Matched by certificate designator
ATA 5730

Part: SKIN — CRACKED (WS 570)

WHILE ACCOMPLISHING INSPECTIONS PER SI 7-70958-12AD, A CRACK INDICATION WAS FOUND ON THE LT WING LWR SURFACE AT IWS 570, S10. REPAIRED PER ERA 331492-14AD.

Source: SDR DLL10980760
OTHER · 1998-04-03 Matched by certificate designator
ATA 5320

Part: PRESSURE DECK — CRACKED (BS 395-437)

NLG PRESSURE DECK WAS FOUND CRACKED IN FIVE LOCATIONS. ALL WERE AT THE EDGES OF PAD UP AREAS IN THE PANEL WHERE THE NLG VERT WALL STIFFENERS TIE INTO THE PRESSURE DECK. REPAIRED PER ERA 331507-14.

Source: SDR DLL10980754
OTHER · 1998-04-03 Matched by certificate designator
ATA 5730

Part: SKIN — CRACKED (WS 477)

WHILE ACCOMPLISHING INSPECTION PER SI7-70953-12AD, A CRACK INDICATION WAS FOUND ON THE RT WING LWR SURFACE AT IWS 477, S17. REPAIRED PER ERA 331493-14AD.

Source: SDR DLL10980759
OTHER · 1998-04-03 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 1615)

MULTI ELEMENT CORROSION WAS FOUND IN THE AFT LT SIDE OF THE C2 CARGO COMPT BETWEEN FS 1585 AND FS 1665. DAMAGE INCLUDES SKIN, STRINGERS, FRAME AND SKIN CLIP. REPAIRED PER ERA 331474-14.

Source: SDR DLL10980756
OTHER · 1998-04-03 Matched by certificate designator
ATA 5330

Part: SKIN — DENTED (BS 718)

DENTS FOUND ON FUSE SKIN FROM 709 TO 730 BETWEEN S22-24. REPAIRED PER ERA 331484-14.

Source: SDR DLL10980753
OTHER · 1998-04-03 Matched by certificate designator
ATA 5320

Part: FITTING — CORRODED (BS 901)

TWO OF THE LWR DOOR SILL INBD CAP FITTINGS LOCATED AT FS 901 USED ON BOTH RT AND LT SIDES WERE FOUND CORRODED AND REQUIRED REPLACEMENT. REPAIRED PER ERA 331465-14.

Source: SDR DLL10980751
OTHER · 1998-04-03 Matched by certificate designator
ATA 5310

Part: PANEL — CRACKED (FS 380)

FUSE HORIZ PRESSURE DECK PANEL WAS FOUND WITH APPROX 0.75 INCH CRACK. THE CRACK IS LOCATED AT RBL 102 JUST AFT OF FS 378. REPAIRED PER ERA 331483-14.

Source: SDR DLL10980757
OTHER · 1998-04-02 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 760)

CORROSION WAS FOUND ON THE FWD BELLY SKIN BETWEEN FS 539 AND 983. REPAIRED PER ERA 331516-14.

Source: SDR DLL10980716
OTHER · 1998-03-09 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (PAX DOORWAY)

A TYP CRACK WAS FOUND AT THE UPPER AFT CORNER OF THE R1 DOOR PASSENGER DOOR. REPAIRED PER ERA 331475-14.

Source: SDR DLL10980544
OTHER · 1998-03-09 Matched by certificate designator
ATA 5343

Part: FITTING — CRACKED (BS 449)

DURING RTN INSPECTION OF THE FS 449 BLKHD, TYP DAMAGE WAS FOUND TO THE RT NLG TRUNNION FITTING. THE FITTING HAD A CRACK IN THE INBD FLANGE. THIS CRACK IS TYP PER SB 093-53-233. THIS AC WAS PREVIOUSLY REPAIRED USING THE 1642622-101/-102 PREVENATIVE MOD PER SAME SB. REPAIRED PER ERA 331464 14AD.

Source: SDR DLL10980542

1997

OTHER · 1997-11-21 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 790)

FUSELAGE/SKIN FS 783 TO 805 STR 33 TO 35 : CORROSION CUTOUT REPAIR. THE FUSELAGE SKIN BETWEEN FS 783 AND 805 AND STR 33 TO 35 WAS FOUND CORRODED RESULTING IN TWO CUTOUTS. THE SKIN CUTOUTS WERE REPAIRED WITH A DOUBLER AND TRIPLER PER ER/A 363222-14 REV A.

Source: SDR DLL10972465
SMOKE/FUMES/ODORS/SPARKS · 1997-10-12 Matched by certificate designator
ATA 2330

Part: PROJECTOR — FAILED (CABIN)

AFT PROJECTOR QUIT RUNNING AND EMITTED BURNED SMELL IN CABIN. DISCONNECTED CANNON PLUG AND COAX CABLE. REPLACED PROJECTOR.

Source: SDR DLL10972044
FLUID LOSS; WARNING INDICATION · 1997-07-09 Matched by certificate designator
ATA 7260

Part: CHIP DETECTOR — DEFECTIVE (NR 2 ENGINE)

NR 2 ENG OIL QTY DROPPED TO ZERO, OIL PRESS LOW LIGHT ILLUMINATED. ENG SHUTDOWN, PERFORMED VISUAL INSP, FOUND MASTER CHIP DETECTOR HOUSING DEFECTIVE AND PACKINGS ON CHIP DETECTOR ONE CUT AND ONE MISSING. REPLACED CHIP DETECTOR HOUSING AND PACKINGS, RAN ENG ALL CKS NML.

Source: SDR DLL10971337
OTHER · 1997-06-30 Matched by certificate designator
ATA 5330

Part: SKIN — CORROSION (BS 1550)

THE RT SIDE FUSELAGE BONDED SKIN ASSEMBLY WAS FOUND CORRODED AT STA 1550 IN THE AREA OF STRINGER 28 AND 29. IN ADDITION, A SECTION OF THE C2 DOOR SURROUND TRIPLER WAS FOUND CORRODED IN THE SAME AREA. THE DAMAGE CUTOUTS WERE: 6 (FWD/AFT) X 11 (UP/DOWN) IN THE SKIN AND 1 (FWD/AFT) X 8 (UP DOWN) IN THE DOOR TRIPLER. THE ADJACENT INTERNAL TEAR STRAP WAS ALSO FOUND CORRODED AND WAS REPAIRED PER THE SRM. THE AREA WAS REPAIR WITH A DOUBLER AND APPROVED PER FAA/DER FORM 8110-3, DER DESIGNATION SO-775, DTD 6-30-97.

Source: SDR DLL10971333
NO TEST · 1997-05-06 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

EMERGENCY LIGHTS INOP AT R3, EXIT SIGNS AND CEILING LIGHTS. REMOVED AND REPLACED EMERGENCY PWR SUPPLY, CKS NORMAL.

Source: SDR DLL10970867
WARNING INDICATION · 1997-04-24 Matched by certificate designator
ATA 5230

Part: SEAL — FAILED (C 2 DOOR)

RAPID LOSS OF CABIN PRESS AT FL 350, OUTFLOW VLV IN NORMAL AND WERE FIXED THERE USING MANUAL CONTROL PRESS CONTROL. SYSTEM SEEMED NORMAL PASSENGERS OXY SYSTEM ACTIVATED AUTO ON X/FEED. VALVE CLOSED NR 3 HP VLV WAS LATCHED. NOISE REPORTED AT ROW 45. FOUND C2 DOOR SEAL BLOWN OUT AT TOP OF DOOR.

Source: SDR DLL10970752
OTHER · 1997-04-24 Matched by certificate designator
ATA 3520

Part: PSU — CRACKED (CABIN)

PASSENGER O2 MASKS AT ROWS 37C DID NOT DEPLOY AUTOMATICALLY OR MANUALLY. ALSO, TUBES AT 36EFG WERE TOO SHORT. REPLACED PSU AT 36EFG AND PSU AT 37C. PERFORMED ADJUSTMENT AND TEST, CHECKS OK.

Source: SDR DLL10970763
WARNING INDICATION · 1997-04-24 Matched by certificate designator
ATA 3520

Part: OXYGEN MASK — FAILED TO DROP (CABIN)

FOLLOWING RAPID LOSS OF CABIN PRESURE AT FL 350, MASK AT SEAT 37 C, F, G DID NOT DROP. ALSO, MASK AT 36 E, F, G WERE TO SHORT. REPLACED PSU AT ALL LOCATIONS AND PERFORMED BITE TES, SYS CK NORMAL.

Source: SDR DLL10971527
NO TEST · 1997-04-19 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

ON L/L CK, FOUND EMERG LIGHT AND SIGN AT 4L DOOR GOES OUT AFTER A FEW SECONDS TEST. REPLACED PWR SUPPLY AT 4L DOOR. TEST WAS GOOD PER MM.

Source: SDR DLL10970720
ENGINE STOPPAGE · 1997-01-24 Matched by certificate designator
ATA 7331

Part: FUEL FLOW REG — MALFUNCTIONED (NR 3 ENGINE)

TAILPIPE FIRE NR 3 ENG AT THE START OF T/O ROLL. ACCOMPLISHED EMERGENCY PROCEDURES AND FOLLOW UP ITEM IN POM. SPEED NEVER EXCEED 10 KTS, NO ENGINE PARAMETERS EXCEEDED ENGINE ROLLBACK AND SHUTDOWN AS THROTTLE BROUGHT TO IDLE. REPLACED FUEL FLOW REGULATOR PER M/M, NO LEAKS ON ENG RUN. OPERATION NORMAL PER PFHB, PERFORMED VISUAL INSPECT ENG AND PYLON AND NO DAMAGE FOUND.

Source: SDR DLL10970140

1996

FLUID LOSS · 1996-07-22 Matched by certificate designator
ATA 2913

Part: PUMP — CRACKED (NR 2 ENG)

IN CRUISE B-SYSTEM HYDRAULIC RESERVOIR LOW QUANTITY LIGHT ON WITH FLUID LEVEL AT THREE-EIGHTS FULL. AT SAME TIME, NOTED B2 ATM ON PRESSURIZING B-HYDRAULIC SYSTEM AND B-PUMP LOW PRESSURE LIGHT ON FLUID LOSS STOPPED WITH PUMPS TURNED OFF. FOUND B-SYSTEM ENGINE DRIVEN PUMP CASTING CRACKED. REPLACED SAME. OPS CHECK GOOD.

Source: SDR DLL10961753

1995

OTHER · 1995-07-14 Matched by certificate designator
ATA 5312

Part: BLKHD WEB — CRACKED (FS 1363)

A CRACK WAS FOUND IN THE FS 1363 BULKHEAD WEB AND LOWER CAP, LOCATED BETWEEN STR 47 AND 48. REPAIRED PER DL ERA 271397-14.

Source: SDR DLL10954504
OTHER · 1995-02-08 Matched by certificate designator
ATA 7110

Part: NOSE COWL — CRACKED (1/3 ENG)

DURINE A ROUTINE SHOP INSPECTION, NR 1 ENGINE NOSE COWL, FOUND CRACKED AT FORWARD BULKHEAD OUTER ANGLE OF NOSE COWL. THE CRACK WAS REPAIRED PER SRM 54-21-00.

Source: SDR DLL10950739
OTHER · 1995-01-25 Matched by certificate designator
ATA 5755

Part: SKIN — DELAMINATED (SPOILER)

ON INITIAL SHOP INSPECTION, SPOILER PANEL WAS FOUND WITH 4 AREAS OF DELAMINATION ON THE LOWER SKIN. AT 48 INCHES, AND 4 INCHES FROM THE OUTBOARD END OF SLAT ON THE TRAILING EDGE, ALSO AT THE INBOARD TRAILING EDGE AND 24 INCHES FROM THE INBOARD END AT THE T/E OF SLAT, REPAIRED PER SRM 57-52-00.

Source: SDR DLL10950600