N202FR

AIRBUS A320-214 · 2008 · Fixed-wing multi-engine · 2 engines · 182 seats · Valid Registration

Registered owner: UMB BANK N A TRUSTEE, UT (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

31 reports on file, 2012-02-11 – 2021-08-19.

WARNING INDICATION · 2021-08-19 Matched by certificate designator
ATA 5246

Part: LATCH — OUT OF ADJUST (FUEL DOOR) · airframe 44,889 hrs · 17,613 cycles

DISCREPANCY: LP1199237 ITEM 1: AT APPROXIMATELY 80-90 KNOTS ON TAKEOFF, REFUEL PANEL CAME OPEN. T/O WAS ABORTED. HIGHEST BRAKE TEMP WAS 738. CORRECTIVE ACTION: ADJUSTED REFUELING PANEL DOOR LATCHES. OPS CHECKED GOOD. REF AMM 28-25-58-400-001-A.

Source: SDR F3LA2021082000061
OTHER · 2021-07-10 Matched by certificate designator
ATA 2565

Part: SLIDE — LEAKING (R1 DOOR) · airframe 44,492 hrs · 17,415 cycles

R1 SLIDE RESERVOIR PRESSURE IS FOUND OUT OF LIMITS. PER EO # A0-25EO-35106, AD 2020-25-03. REMOVED R1 DOOR SLIDE ASSY IAW AMM 25-62 44-012-A. INSTALLED R1 DOOR SLIDE ASSY PER AMM 23-62-44-400-805-A. TEST OK.

Source: SDR F3LA2021072100056
FLUID LOSS; WARNING INDICATION · 2021-04-29 Matched by certificate designator
ATA 2910

Part: LINE — FAILED (HYD SYSTEM) · airframe 43,846 hrs · 17,108 cycles

LP133846 ITEM 1 DISCREPENCY -- HYD Y RSVR LO LVL CORRECTIVE ACTION: REMOVED AND REPLACED #2 ENG YELLOW HCU PIPE REF AMM 29-13-49-000-048-A AND AMM 29-1349-400-099-A OPS CHECK/LEAK CHECK GOOD. T/W F9T10230C DUE 6/21. SERVICED YELLOW HYD SYST. REF AMM 12-12-29-611-001-A.

Source: SDR F3LA2021050300034
Earlier reports · 2012–2019 · 28 reports

2019

SMOKE/FUMES/ODORS/SPARKS · 2019-09-02 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (COCKPIT) · airframe 41,674 hrs · 16,168 cycles

SMELLED BURNING ELECTRIC FOR ABOUT 30 SEC ONLY IN COCKPIT NO SMOKE ASSOCIATED W/SMELL. CONDUCTED VISUAL INSPECTION OF AVIONICS COMPARTMENT AND NO DEFECTS FOUND AT THIS TIME. PERFORMED 10 MINUTE GROUND RUN. NO DEFECTS OF SMELLS ACCURD. OPS CHECK GOOD. OK FOR SERVICE. TSM 05-50-00-810-831A

Source: SDR F3LA201909030101
FLUID LOSS; SMOKE/FUMES/ODORS/SPARKS · 2019-05-15 Matched by certificate designator
ATA 4920

Part: APU — LEAKING (APU BAY) · airframe 40,537 hrs · 15,698 cycles

DISCREPANCY: REFERENCE LP1170958 ITEM#1 - ON DECENT F/A'S NOTICED STRONG ACRID ODOR WAS ALSO NOTICED IN THE COCKPIT. CORRECTIVE ACTION - REF TDI CNTRL# 1150146 FOR PRIOR FUME EVENT. PER ES# AO21T - 34386 C/W TROUBLESHOOTING IAW TSM 05-50-00-810-831-A. CAPTAIN OPERATED ENGINES FOR TROUBLESHOOTING PER TSM 71-00-00-810-802. BOTH ENGINES AND PACKS OPERATED WITH NO ODORS NOTED AND VERIFIED BY CREW. 2ND EVENT OF TDI CNTRL# TDI DUE DATE REMAINS THE SAME. FINAL CORRECTIVE ACTION - LP1170958 ITEM 3 - REF MDDR 1150143 R&R APU REF AMM 49-11-11PB401 OPS CHECK GOOD NO OTHER DEFECTS NOTED AT THIS TIME. T/W USED F9TAB5836 CAL 6/19 MEL REMOVED./END/

Source: SDR F3LA2019051700038
FLUID LOSS; SMOKE/FUMES/ODORS/SPARKS · 2019-05-11 Matched by certificate designator
ATA 4920

Part: APU — LEAKING (APU BAY) · airframe 40,503 hrs · 15,681 cycles

DISCREPANCY: REFERENCE LP1110900 ITEM 1. FIRST FLT OF THE DAY TURNED APU ON AND A STRONG DIRTY MUSTY SOCK ODOR FILLED THE CABIN. TURNED PACKS OFF AND ODOR RESCINDED. CORRECTIVE ACTION: TROUBLE SHOOTING PER TSM 05-50-00-810-831-A AND EA#A0-211-34386 FOUND OIL LEAK AT APU. PLACED APU ON MEL 49-10-01A CTRL# 1150143 DUE DATE 5-21-19. DISCREPANCY: ITEM 2, REF MEL 49-10-01A REF# LP1110900-1 DIRTY SOCK SMELL WITH APU BLEED. CORRECTIVE ACTION: DEF APU PER LP1110900-1, PERFORMED DECONTAMINATION OF ECS VIA PACK 1&2 BURN OUT IAW AMM 21-00-00-160-059-A NO ODORS NOTED AT THIS TIME AMM 21-00-00-1690-059-A. DISCREPANCY: ITEM 3. REF LOG PAGE LP1110900 1&2 PERFORMED CABIN ODOR TROUBLE SHOOTING IAW TSM 05-50-00-810-831-A AT NEXT CONVENIENT MAINTENANCE OPPORTUNITY BEFORE 60 FC PER EA # A0-21T-34386. CORRECTIVE ACTION: DEF PER TSM TROUBLESHOOTING TDI #1150146./END/

Source: SDR F3LA2019051400037

2018

SMOKE/FUMES/ODORS/SPARKS · 2018-11-06 Matched by certificate designator
ATA 2300

Part: PANEL — DEFECTIVE (ZONE 200) · airframe 38,730 hrs · 14,931 cycles

DISCREPANCY: REFERENCE LOG PAGE LP1112557 ITEM 1, RMP 1 MALFUNCTION VERY STRONG ELECTRICAL ODOR. CORRECTIVE ACTION: REMOVED AND REPLACED 1RG1 RMP REF AMM 23-13-13-400-001-A. OPS TEST OK, A/C OK TO CONTINUE./END/

Source: SDR F3LA2018110800478
OTHER · 2018-10-24 Matched by certificate designator
ATA 2720

Part: CONTROL CABLE — CORRODED (RUDDER) · corrosion level 2 · airframe 38,717 hrs · 14,926 cycles

DISCREPANCY: REFERENCE N/R 2168N511 RUDDER LT OUTBOARD CABLE RUSTED LOCATED UNDER DUMMY BEAM Y503.2. CORRECTIVE ACTION: CABLE FWD CONNECTION REMOVED AND REPLACED WITH NEW CABLE IAW AMM 27-21-61 PB401 AND AMM 27-21-820-002-A./END/

Source: SDR F3LA2018103100475
OTHER · 2018-10-16 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 38,717 hrs · 14,926 cycles

DISCREPANCY: REFERENCE N/R 2168N412, P/R (721615) FLOORBEAM Y765 CORRODED AT FR66-70. CORRECTIVE ACTION: EVALUATED FLOORBEAM Y765 AT FR66-70. REMOVED .030 MAT. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-42-11./END/

Source: SDR F3LA2018102200459
OTHER · 2018-10-15 Matched by certificate designator
ATA 7830

Part: BEAM — CRACKED (THRUST REVERSER) · airframe 38,717 hrs · 14,926 cycles

DISCREPANCY: REFERENCE N/R 2168N342 CRACK ON ENG 2 I/B THRUST REVERSER PIVOT FITTING BEAM. CORRECTIVE ACTION: REMOVED AND REPLACED NR 2 ENG I/B THRUST REVERSER KEEL BEAM UPPER FAIRING WEB IAW GOODRICH CMM 78-32-36 REPAIR 61./END/

Source: SDR F3LA2018102900469
OTHER · 2018-10-12 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 38,717 hrs · 14,926 cycles

FLOORBEAM -Y1292 CORRODED AT FR16. REMOVED AND REPLACED FLOORBEAM -Y1292 AT FR 16 IAW SRM 51-72-11, SRM 51-74-00, TASK 5-A AND SRM 53-11-14-283-004.

Source: SDR F3LA2018102500465
OTHER · 2018-10-12 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 38,717 hrs · 14,926 cycles

DISCREPANCY: REFERENCE N/R 2168N291, FLOORBEAM Y1292 CORRODED AT FR16. CORRECTIVE ACTION: EVALUATED FLOORBEAM Y1292 AT FR16 FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14-283-004. REPLACED FLOORBEAM IAW SRM 51-72-11-911-001./END/

Source: SDR F3LA2018102200461
OTHER · 2018-10-12 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 38,717 hrs · 14,926 cycles

FLOORBEAM -Y254 CORRODED AT FR16. REMOVED AND REPLACED FLOORBEAM -Y254 AT FR16 IAW SRM 51-72-11 AND SRM 51-74-00 TASK 5-A AND 53-11-14-283-004.

Source: SDR F3LA2018102500466
OTHER · 2018-10-11 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 38,718 hrs · 14,926 cycles

DISCREPANCY: REFERENCE N/R 2168N246, FLOORBEAM CORRODED BETWEEN FR16 TO FR20. CORRECTIVE ACTION: REMOVED AND REPLACED FLOORBEAM IAW 51-72-11-911 AND 53-11-15-283-003./END/

Source: SDR F3LA2018102900473
OTHER · 2018-10-11 Matched by certificate designator
ATA 5320

Part: DOOR SILL — CORRODED (FUSELAGE) · corrosion level 2 · airframe 38,717 hrs · 14,926 cycles

DISCREPANCY: REFERENCE N/R 2168N247, R2 DOOR SILL CORRODED AT FWD SPLICE FR66. CORRECTIVE ACTION: REMOVED AND REPLACED R2 DOOR SILL IAW SRM 51-72-11 AND SRM 53-41-14./END/

Source: SDR F3LA2018102600467
OTHER · 2018-10-11 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 38,717 hrs · 14,926 cycles

DISCREPANCY: REFERENCE N/R 2168N241, FLOORBEAM Y254 CORRODED 2 INCHES FWD OF FR66. CORRECTIVE ACTION: REMOVED AND REPLACED FLOORBEAM Y254 FR66 IAW SRM 51-72-11-911-001, 51-74-00, 51-44-11, 53-00-14-283-003./END/

Source: SDR F3LA2018102300462
OTHER · 2018-10-11 Matched by certificate designator
ATA 5320

Part: DOOR SILL — CORRODED (FUSELAGE) · corrosion level 2 · airframe 38,717 hrs · 14,926 cycles

DISCREPANCY: REFERENCE N/R 2168N238, L2 DOOR SILL CORRODED AT FR66 FWD SPLICE. CORRECTIVE ACTION: REMOVED AND REPLACED DOOR SILL (L2 DOOR) IAW SRM 53-41-14-283-002, SRM 51-72-11-911-001, AMM 38-30-00-010-002, AMM 38-30-00-410-002A, AMM 52-13-31-000-003-A AND AMM 52-13-31-400-007-A./END/

Source: SDR F3LA2018102900470
OTHER · 2018-10-11 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 38,717 hrs · 14,926 cycles

DISCREPANCY: REFERENCE N/R 2168N233 FWD DUMMY BEAM Y503.2 CORRODED BETWEEN FR12 TO FR16. CORRECTIVE ACTION: DUMMY FLOORBEAM REMOVED AND REPLACED IAW SRM 51-72-11-911 (FR12 TO FR16)./END/

Source: SDR F3LA2018102300464
OTHER · 2018-10-11 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 38,717 hrs · 14,926 cycles

DISCREPANCY: REFERENCE N/R 2168N242, FLOORBEAM -Y765 CORRODED AT FR66-FR70. CORRECTIVE ACTION: REMOVED AND REPLACED FLOORBEAM -Y765 FR66 TO FR70 IAW SRM 51-72-11, 51-44-11, 53-00-14-283-002./END/

Source: SDR F3LA2018102300463
OTHER · 2018-10-11 Matched by certificate designator
ATA 5320

Part: SHEAR WEB — CORRODED (FUSELAGE) · corrosion level 2 · airframe 38,717 hrs · 14,926 cycles

DISCREPANCY: REFERENCE N/R 2168N230, LT FR70 LATERAL SHEAR WEB PLATE AT CABIN FLOOR CORROSION. CORRECTIVE ACTION: EVALUATED LT FR70 SHEAR WEB FOUND TO BE OUT OF LIMITS IAW SRM 51-11-11. REPLACED SHEAR WEB IAW SRM 51-72-11./END/

Source: SDR F3LA2018102200460
SMOKE/FUMES/ODORS/SPARKS · 2018-07-25 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 38,002 hrs · 14,622 cycles

FLIGHT ATTENDANTS COMPLANIED OF ODOR FUMES DURING TAXI. UPON DEBRIEF THEY SAID THEY COULD SMELL IN DESCENT. DID TRY TO ISOLATE BETWEEN PACK 1 AND 2 DURING SHORT TAXI, NO HELP. PER AMM 05-50-00-810-831-1A. INSPECTED ENGINE. APU AND PACKS FOR POTENTIAL OIL AND HYDRAULIC LEAKS. NONE FOUND. SUSPECT OUTSIDE AIR OR CARRY ON LUGGAGE FOR THE SMELLS. AIRCRAFT OK TO CONTINUE.

Source: SDR F3LA2018072600375
SMOKE/FUMES/ODORS/SPARKS · 2018-05-31 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 37,373 hrs · 14,359 cycles

AT FL350 F/AS CALLED AND SMELLED AN ODOR LIKE MUSTY DIRTY SOCKS, ELECTRICAL, NAIL POLISH SWEET ODOR FROM ROW 14 AFT. RAN ELIMINATION OF ODOR IN CABIN /COCKPIT CHECKLIST IAW VOL 2. DECLARED EMERGENCY, LANDED SAFELY. MAINTENANCE PERFORMED TSM 05-50-00-810-831-A IAW COS (CAUSE OF SMELL) NR 2 PACK INDICATED HIGHEST PROBABLE SOURCE. PERFORMED TSM 21-00-00-810-802 COULD NOT DUPLICATE ODOR. MAINTENANCE REQUESTED OPS CHECK FLIGHT. MAINTENANCE PERFORMED PERIODIC CHECK IAW FFT-M05100-M0-1. MAINTENANCE ALSO SERVICED THE CREW O2 IAW AMM 35-11-41 PB 401. OPS CHECK FLIGHT COMPLIED WITH AND FOUND SATISFACTORY. RETURNED TO SERVICE.

Source: SDR F3LA2018060400350

2016

WARNING INDICATION · 2016-09-14 Matched by certificate designator
ATA 3260

Part: PROXIMITY SENSOR — OUT OF ADJUST (MLG) · airframe 30,536 hrs · 11,696 cycles

LANDING GEAR NOT UPLOCKED. LANDING SYSTEM DISAGREE, AIR TURNBACK. POST FLIGHT REPORT SHOWED 25GA NLG EXTENTION PROXIMITY SWITCH IAW TSM 32-31-00-810-842-A AND 32-31-00-810-868-A. REMOVED AND REPLACED PROXIMITY SWITCH 25GA AND ADJUSTED DIMENSIONAL CHECKS FOR 25GA AND 24GA. IAW AMM 32-31-73-820-006-A. NUMBERS 1 AND 2 LGCIU OPS CHECKED GOOD IAW AMM 32-69-00-740. OPS CHECK FLIGHT AND POST FLIGHT WALK AROUND PERFORMED AND FOUND SATISFACTORY. AIRCRAFT RELEASED FOR SERVICE.

Source: SDR F3LA2016091500055

2013

OTHER · 2013-09-03 Matched by certificate designator
ATA 5320

Part: PLATE — CORRODED (ZONE 200) · corrosion level 2 · airframe 19,289 hrs · 7,009 cycles

ACFT IS OUT OF SERVICE FOR C4/S1 CHECK. AFT CABIN LATERAL PLATE HAS CORROSION AT FR 69-70, S23R. R & R SHEAR PLATE IAW SRM 51-42-11, PAR 6, PAR 7, AND PAR 13.

Source: SDR F3LA2013091600909
OTHER · 2013-08-27 Matched by certificate designator
ATA 5330

Part: SKIN — DENTED (ZONE 100) · airframe 19,289 hrs · 7,009 cycles

ACFT IS OUT OF SERVICE FOR C4/S1 CHECK. RT FWD FUSELAGE FR 10, STRINGER 23R DENTED. REPAIRED IAW SRM 53-11-11 PB201, PARA 5.J.

Source: SDR F3LA2013091600907
OTHER · 2013-08-27 Matched by certificate designator
ATA 5330

Part: SKIN — GOUGED (ZONE 100) · airframe 19,289 hrs · 7,009 cycles

ACFT IS OUT OF SERVICE FOR C4/S1 CHECK. LOWER FUSELAGE AT FR 53, STRINGER 37L, DENTED WITH A GOUGE IN THE CENTER. REPAIRED IAW SRM 53-41-11, PB201.

Source: SDR F3LA2013091600908
OTHER · 2013-08-19 Matched by certificate designator
ATA 5330

Part: SKIN — DENTED (ZONE 100) · airframe 19,289 hrs · 7,009 cycles

ACFT OUT OF SERVICE FOR C4/S1 CHECK. DENT FWD OF THE L2 DOOR APPROXIMATELY .054" DEEP, 3.5" LONG, 3.375" WIDE. REPAIRED IAW SRM 53-00-11, PB201, PARA 4.A.

Source: SDR F3LA2013091600906

2012

FLUID LOSS; WARNING INDICATION · 2012-10-29 Matched by certificate designator
ATA 2910

Part: LINE — CHAFED (HYD SYSTEM) · airframe 16,535 hrs · 5,911 cycles

YELLOW SYS LOW LEVEL HYDRAULICS. R & R NR 2 ENGINE HYD LOW PRESSURE SWITCH TUBE. REF AMM 29-13-49-000-005A AND 29-13-49-400-005A. OPS AND LEAK CHECK GOOD.

Source: SDR F3LA2012102800807
OTHER · 2012-03-10 Matched by certificate designator
ATA 5270

Part: PROXIMITY SWITCH — FAILED (PAX DOOR) · airframe 14,364 hrs · 5,062 cycles

MAIN CABIN DOOR DOES NOT SHOW CLOSED ON ECAM WHEN IT IS CLOSED. R & R LT 1 DOOR PROXIMITY SWITCH, OPS CHECK GOOD AMMS2-71-11-401.

Source: SDR F3LA2012003140721
FALSE WARNING · 2012-02-17 Matched by certificate designator
ATA 2560

Part: GIRT BAR — OUT OF ADJUST (R2 DOOR) · airframe 14,133 hrs · 4,972 cycles

R2 DOOR ARMED INDICATION INTERMITTENT. FOUND R2 DOOR GIRT BAR FITTING OUT OF ADJUSTMENT. ADJUSTED R2 DOOR GIRT BAR FITTING AMM 52-13-00-820-057 A.

Source: SDR F3LA2012022300711
FALSE WARNING · 2012-02-11 Matched by certificate designator
ATA 5270

Part: PROXIMITY SWITCH — FAILED (L1 DOOR) · airframe 1,403 hrs · 4,965 cycles

L1 DOOR INDICATES OPEN WHEN IT IS CLOSED. R & R L1 DOOR PROXIMITY SWITCH AMM52-71-11, PB 401.

Source: SDR F3LA2012021400708