N206NV
Registered owner: ALLEGIANT AIR LLC, NV (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
14 reports on file, 2022-06-03 – 2026-09-09.
Part: HINGE — CORRODED (ZONE 400) · airframe 35,504 hrs · 18,200 cycles
(AIRCRAFT NOT GROUNDED) (DEFECT DISCOVERED DURING AC HEAVY MX VISIT) NRC 4000-0010: 1205-06 ENGINE NR 2 PYLON OVERPRESSURE PANEL 481CR HINGE CORRODED. ENGINE NR 2 PYLON OVERPRESSURE PANEL 481CR HINGE REPLACED IAW SRM 51-42-11 REV.159.
Part: EPSU — INOPERATIVE (ZONE 200) · airframe 35,504 hrs · 18,200 cycles
(AIRCRAFT NOT GROUNDED) (DEFECT DISCOVERED DURING AC HEAVY MX VISIT) NRC 7000-0006: IN AFT PASSENGER CABIN, ALL LIGHT RELATED TO EPSU 13WL INOP. EPSU TO REPLACED. IN AFT PASSENGER CABIN, EPSU 13WL REPLACED AND TESTED SERVICEABLE IAW AMM 33-51-38-400-001-A"
Part: APU — ODOR (ZONE 100) · airframe 34,329 hrs · 17,650 cycles
(AIRCRAFT NOT GROUNDED) DIRTY SOCK SMELL ASCENDING THRU FL 210. DISSIPATED ON ITS OWN WITHIN A FEW MINUTES / PERFORMED TC A32X-21-000-001 AND FOUND SOURCE OF ODOR COMING FROM THE APU. PERFORMED LEVEL II DECONTAMINATION REF TASKCARD A32X-21-000-002. REMOVED & REPLACED FCU IAW AMM 49-32-11-000-003-A & 49-32-11-400-003-A, REMOVED AND REPLACED OIL COOLING FAN IAW AMM 49-52-51-000-002-A & 49-52-51-400-002-A. OPS & LEAK CHECK GOOD. CLEANED APU COMPARTMENT IAW AMM 49-00-00-100-003-A, CLEANED AIR INTAKE IAW AMM 49-16-00-100-005-A, CLEANED APU COMPARTMENT DOORS IAW AMM 49-00-00-100-807-A. PERFORMED BLEED DUCT DECON IAW AMM 36-12-00-615-807-A. PERFORMED AMM 21-00-00-615-802-A TO VERIFY NO ODOR IN CABIN.
Part: UNKNOWN — ODOR (CABIN) · airframe 34,220 hrs · 17,603 cycles
(AIRCRAFT NOT GROUNDED) DIRTY SOCK SMELL REPORTED BY OFFGOING CABIN CREW (DURING DESCENT). SMELL IS STRONG ENOUGH TO PERSIST WELL AFTER CREW CHANGE./ COMPLIED WITH TC A32X-21-000-002 , NO SMELL OR DEFECTS NOTED (W/O: 545015, TASKCARD: NR-00001)."
Earlier reports · 2022–2025 · 10 reports
2025
Part: SWITCH — FAULTED (HYD SYSTEM) · airframe 32,637 hrs · 16,777 cycles
(AIRCRAFT NOT GROUNDED) (EMERGENCY DECLARED) AT CRUISE Y SYS LO PR ON ECAM / PER TSM 29-13-00-810-801-A FOUND LOW LEVEL SWITCH INOPERATIVE . R/R LOW LEVEL SWITCH IAW AMM 29-13-41-000-004 & AMM 29-13-41-400-004 NO DEFECTS NOTED AT THIS TIME LEAK CHECK & OPS CHECK GOOD A/C OK FOR SVC.
Part: BATTERY PACK — NO TEST (ZONE 200) · airframe 32,298 hrs · 16,612 cycles
(AIRCRAFT NOT GROUNDED) EPSU FAILED CAPACITANCE CHECK / REPLACED ALL 4 EPSU BATTERIES, OP CHECK OF EPSU THRU BITE GOOD, INTERFACE AND POWER-UP TEST OF CIDS GOOD, REF AMM 33-51-38-400-002-A"
2024
Part: HANDLE — OUT OF ADJUST (ZONE 800) · airframe 31,279 hrs · 16,080 cycles
(AIRCRAFT NOT GROUNDED) DOOR R FWD EMERGENCY EXIT - ECAM OCCURED JUST AFTER GEAR EXTENSION ON FINAL APPROACH. / USING TSM 52-21-00-810-803-A, FOUND RH FWD OVERWING EMERGENCY EXIT PROXIMITY SWITCH HANDLE FLAP OUT OF ADJUSTMENT. ADJUSTED PROXIMITY SWITCH FOR HANDLE FLAP IAW AMM 52-71-13-400-001-A. OPS CHECK OF EMERGENCY EXIT HANDLE FLAP GOOD, SHOWING ARMED ON ECAM, FAP AND DOOR ARMED LIGHT BESIDE DOOR."
Part: WARNING MESSAGE — FALSE ACTIVATION (ZONE 800) · airframe 31,276 hrs · 16,076 cycles
(AIRCRAFT NOT GROUNDED) AFTER ENG SHUTDOWN RT FWD EMER OVERWING EXIT SHOWED OPEN. / OPS CHECKED RH FWD EMER DOOR IAW AMM 52-21-11-400-001-A. ALL OPS CHECKED GOOD AT THIS TIME. "
Part: SLIDE — NO TEST · airframe 30,350 hrs · 15,600 cycles
DURING OPERATIONAL TEST OF THE EPSU THROUGH BITE CHECK PER AMM 33-51-00-710-001-A, BITE CHECK IS FAILING AND GIVING MESSAGE ""ESCAPE SLIDE LT/EPSU (13WL) AFT L"". / C/W TSM 25-62-00-810-819-A REMOVED AND REPLACED ESCAPE SLIDE AFT L 7502MM IAW AMM 25-62-44-000-002-A AND AMM 25-62-44-400-006-A OPS CHECK GOOD."
2023
Part: EPSU — UNKNOWN (UNKNOWN) · airframe 29,614 hrs · 15,145 cycles
PERFORMED EPSU BITE TEST AMM 33-51-00-710-001 PER WEEKLY CHECK EPSU (11WL) FAILED. / REMOVED AND REPLACED EPSU BATTERY IAW AMM 33-51-38-000-002-A AND 33-51-38-400-002-A. OPS CHECK GOOD"
Part: EPSU — UNKNOWN (UNKNOWN) · airframe 28,777 hrs · 14,672 cycles
EMERGENCY LIGHT BATTERY INOP / REMOVED AND REPLACED IAW AMM ÿ½33-51-38-000-001-A AND 33-51-38-400-001-A. OPS CHECK GOOD."
Part: NONE — NONE · airframe 27,879 hrs · 14,192 cycles
LEFT/RIGHT OVERWING EMERGENCY EXIT LIGHT HAS 1 LAMP EACH INOP (FAR AFT) / REMOVED AND REPLACED 1EA LAMP L/H, R/H OVERWING AFT EMERGENCY EXIT LIGHT IAW AMM 33-51-15-000-001-A. AND 33-51-15-400-001-A. PERFORMED OPS CHECK. OPS CHECK GOOD."
2022
Part: BATTERY — INOPERATIVE · airframe 26,956 hrs · 13,732 cycles
EPSU BATTERY (12WL) FAILED AT EPSU BITE TEST. / REMOVED AND REPLACED EPSU BATTERY (12WL) IAW AMM 33-51-38-000-002-A AND 33-51-38-400-002-A."
Part: SEAL — NOISY · airframe 26,324 hrs · 13,440 cycles
REF LP 1668308 FA REPORTS WHISTLING FROM 12A EMERGENCY EXIT. / REMOVED AND REPLACED LEFT HAND FORWARD HATCH SEAL IAW AMM 52-21-`18-960-003-A."