N209HA
Registered owner: WILMINGTON TRUST CO TRUSTEE, DE (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
57 reports on file, 2018-07-31 – 2026-10-19.
Part: LATCH — LACK OF LUBE (ZONE 800) · airframe 25,825 hrs · 5,592 cycles
1L DOOR LATCH OPEN/RELEASE BUTTON HAS DIFFICUTLY LOCKING/UNLOCKING. GROUNDED - YES. CLEANED AND LUBRICATED LATCH AS REQUIRED. OPS CHECK GOOD. OK FOR SVC.
Earlier reports · 2018–2025 · 56 reports
2025
Part: COFFEEMAKER — SHORTED (ZONE 900) · airframe 22,416 hrs · 4,852 cycles
ATB, STRONG AND PRESISTENT ELEC BURNING ODOR IN FWD GALLEY. GALLEY MASTER COMMERCIAL AND GALLEY & CABIN SECURED PER QRH PROC WITH NO IMPROVEMENT. NO VISIBLE SMOKE. INSPECTED FWD GALLEY AND FOUND COFFEE MAKER POSITIONED IN F111 SHORTED. REMVOED AND REPLACED COFFEE MAKER PER AMM 25-35-21. OPS,SECURITY CHECK GOOD. NO ELECTRICAL SMELL PRESENT AFTER REPLACEMENT. OK FOR SERVICE.
Part: ACM — DAMAGED · airframe 22,248 hrs · 4,817 cycles
ETOPS - AIR R WING LEAK. FOUND AIR CYCLE MACHINE DAMAGED REMOVED ACM IAW A321 AMM 21-52-21. INSTALLED NEW ACM PER A321 AMM 21-52-21 NO LEAKS NOTED NO ECAM FAULTS NOTED CHKS OK.
Part: DISPLAY — MALFUNCTIONED (ZONE 200) · airframe 22,016 hrs · 4,772 cycles
ETOPS - MCDU #1 SCREEN FLICKERING AFTER ENG START. BTB. REMOVED AND REPLACED MCDU #1 TEST OK PER:AMM 22-82-12.
Part: PIN — OUT OF LIMITS (APU STARTER) · airframe 21,312 hrs · 4,628 cycles
ETOPS - APU AUTOSHUTDOWN ON TAXI INTO GATE. FOUND STARTER WEAR PIN BEYOND LIMITS. REMOVED AND REPLACED STARTER PER AMM 49-42-51. OPS CHECK GOOD. OK FOR SVC.
Part: IGNITER — FAULTED (APU) · airframe 20,683 hrs · 4,502 cycles
ETOPS - APU AUTO SHUTDOWN. REMOVED AND REPLACED APU IGNITER PLUG PER AMM 49-41-41. REMOVED AND REPLACED IGNITION UNIT PER AMM 49-41-38. OP'S CHECK GOOD. NO DEFECTS NOTED. OK FOR SERVICE.
Part: SENSOR — DIRTY (TOILETS) · airframe 19,934 hrs · 4,355 cycles
ATB - ALL LAVS NOT FLUSHING. FOUND LIQUID LEVEL SENSOR DIRTY. CLEANED LIQUID LEVEL SENOSR PER AMM 38-31-00. OPS CHECK GOOD. NO FAULTS/DEFECTS NOTED. OK FOR SVC.
Part: ENGINE — DAMAGED (NR 2) · airframe 19,391 hrs · 4,251 cycles
WHILE PERFORMING BOROSCOPE T/C, LPC-2 PLUG WAS FOUND DAMAGED, ENG 2. REPLACED LPC-2 PLUG IAW AMM 72-00-00-400-804-A. LEAK CHECK GOOD. A/C OK FOR SERVICE.
2024
Part: FIRE LOOP — SHORTED (NR 2 ENGINE) · airframe 18,358 hrs · 4,038 cycles
ETOPS - ENG 2 FIRE LOOP A FAULT ILLUMINATED DURING DESCENT FOR 2 MINS AND AGAIN IN PARKING. FOUND INTERNAL SHORT ON ENG #2, LOOP A, AGB (FWD) DETECTOR, FIN 4002WD1. REMOVED AND REPLACED PER AMM 26-12-17. BITE TEST OK. FAULT CLEARED. ENG RUN NORMAL. OK FOR SERVICE.
Part: FEEDER CABLE — BROKEN (FIRE DETECTION) · airframe 18,358 hrs · 4,038 cycles
ETOPS - FOUND HIGH TEMP FIRE DETECTION CABLE ASSY BROKEN. REMOVED AND REPLACED #2 ENGINE FIRE LOOP A ELECTRICAL HARNESS PER AMM 26-12-61. OPS TEST FIRE LOOP/SQUIB PER AMM 26-12-00,OVERHEAT DETECTION PER AM 26-12-61 FADEC #2 PER AMM 73-21-00. SYS NORMAL OK FOR SERVICE.
Part: FIRE LOOP — FAULTED (NR 2 ENGINE) · airframe 18,353 hrs · 4,037 cycles
ETOPS - ENG 2 FIRE LOOP A FAULT ILLUMINATED. REMOVED AND REPLACED FIRE ELERTIC HARNESS ON ENG 2. PER AMM 226-12-61-000-802-A. OPS CHECK GOOD, OK FOR SERVICE.
Part: A/C PACK — FAULTED (NR 2) · airframe 17,845 hrs · 3,936 cycles
ETOPS - AIR PACK 2 REGUL FAULT ON ECAM ON CLUMBOUT. REMOVED AND REPLACED #2 PACK COMP OUTLET TEMP SENSOR PER AMM 21-61-11. OPS,LEAK, SECURITY CHECK GOOD OK FOR SERVICE.
Part: PACKING — LEAKING (FAN SHAFT COVER) · airframe 17,353 hrs · 3,839 cycles
ETOPS - FOUND #1 ENG WITH OIL BELOW INLET CONE. REMOVED AND REPLACED FAN SHAFT COVER PACKING PER AMM 72-15-00-960-801-A. IDLE TEST GOOD. NO LEAKS. OK TO CONTINUE
Part: HOUSING — DAMAGED (FUEL FILTER) · airframe 17,232 hrs · 3,816 cycles
ETOPS - FOUND FUEL FILTER HOUSING DAMAGED ON #2 ENG WHILE PERFORMING TASK CARD E1128-321-73-002. REMOVED AND REPLACED FUEL FILTER ASSEMBLY ON #2 ENGINE PER AMM 73-11-07. OPS CHECK GOOD. LEAK CHECK GOOD. OK FOR SERVICE.
Part: BLADE — DAMAGED (NR 1 ENG) · airframe 17,187 hrs · 3,807 cycles
ETOPS - WHILE REMOVING # 1 ENGINE # 19 BLADE, FOUND # 18 FAN BLADE S/N: LAEDAS9430 DAMAGED/CRACKED AT ROOT. REMOVED AND REPLACED DAMAGED FAN BLADE S/N LAEDA59430 PER AMM 72-11-03. FAN TRIM BALANCE OKAY. OK FOR SVC.
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 16,066 hrs · 3,581 cycles
ETOPS - APU AUTO SHUT DOWN. REMOVED AND REPLACED APU OIL FILTERS PER AMM 49-91-41-200-002-A CONDITION SAME REMOVED + REPLACED BOTH DIFFERENTIAL PRESSURE SWITCHES 49-91-14. FILTER CHECK OK. CHECK OF APU GOOD. OKAY FOR SERVICE
2023
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 14,727 hrs · 3,314 cycles
ETOPS - ENG 2 FIRE LOOP A FAULT/ECAM. REMOVED AND REPLACED #2 ENG LOOP A FWD DETECTOR PER 26-12-17-400-802A. BITE TEST PASSED . NO FAULTS NOTED. OK FOR SERVICE.
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 14,522 hrs · 3,274 cycles
ETOPS - WHEN OPENING #1 ENG TR COWL FOR ENG WASH, NOTICED FLUID LEAK ON RIGHT SIDE OF ENGINE. FOUND HYDRAULIC LEAK ON EDP HYDRAULIC INLINE DAMPER. REPLACED DAMAGED SEALS PER AMM 29-11-46-400-803A. OPS CHECK WAS GOOD. NO LEAKS NOTED. OK TO CONTINUE.
Part: IGNITER BOX — FAULTY (APU) · airframe 13,733 hrs · 3,114 cycles
ETOPS - APU AUTO SHUTDOWN, FAULTING IGNITION EXCITER (8030KM) REPLACED APU IGNITION UNIT REF AMM 49-41-38. ECB SELF TEST GOOD, APU OPS CHECK GOOD. OK TO CONTINUE SERVICE.
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 13,477 hrs · 3,052 cycles
SUPPLEMENTAL TO HALA2023032100054. UPDATED WITH RESOLUTION. ETOPS - DMI # 206678. VENT AVNCS SYS FAULT. RE-ACTIVATED 24HQ ISOL VALVE. OPS CHECK PER AMM 21-26-00-710-001 OK. TEST PER TSM 21-26-00-810-807-A OK . NO FAULTS DETECTED. A/C OK TO CONTINUE. PLACARD REMOVED. MIC SHEET UPDATED.
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 13,442 hrs · 3,045 cycles
DMI # 206678. VENT AVNCS SYS FAULT. AWAITING RESOLUTION
Part: FIRE DETECTOR — SHORTED · airframe 13,293 hrs · 3,014 cycles
ETOPS - ENG 1 FIRE LOOP A FAULT. FOUND FWD PYLON FIRE DETECTOR SHORT TO GROUND REMOVED AND REPLACED FWD PYLON FIRE DETECTOR LOOP A PER AMM 26-12-16 OPS CHECK GOOD.
Part: CONTROLLER — FAULTED (FUEL QTY) · airframe 13,012 hrs · 2,958 cycles
ETOPS-DURING CRUISE LT FUEL TANK TEMP FLUCTUATED BETWEEN -10 DRGREES C TO 49 DEGREES C. REMOVED AND REPLACED FQIC AT 3QT IAW AMM 28-42-34-000-001-A AND 28-42-34-400-001-A. OPS CK GOOD. NO FAULTS. OK TO CONTINUE SVC.
Part: SEAL — DAMAGED (NR 3 BEARING) · airframe 12,870 hrs · 2,930 cycles
ETOPS - RH ENGINE #3 BEARING SEAL (AFT) APPEARS DAMAGED. PHOTOS SENT TO POWERPLANT ENGINEERING. REMOVED AND REPLACED #2 ENGINE PER TASK CARD J321-72-HWI-02. OK FOR SERVICE.
2022
Part: CONTROL VALVE — FAULTED (NR 2 A/C PACK) · airframe 12,477 hrs · 2,851 cycles
ETOPS- A/C PACK NR 2 REGULATOR FAULT DURING CLIMB THROUGH 14,000 FT. CABIN CREW STATED TEMP TOO WARM. REMOVED AND REPLACED THE A/C PACK FLOW CONTROL VALVE IAW AMM 21-51-51-400-001-A AND 21-51-51-000-001-A. OPS AND LEAK CHECKED GOOD. OK TO CONTINUE.
Part: PUMP — FAILED (NR 2 ENGINE) · airframe 12,219 hrs · 2,797 cycles
ETOPS-ENG 2 FUEL VALVE FAULT ECM @ ENGINE SHUTDOWN. REPLACED #2 ENG INTERGRATED FUEL PUMP PER AMM 73-11-01. OPS AND LEAK CHK GOOD
Part: NONE — NONE · airframe 11,847 hrs · 2,724 cycles
EIU-1 FAULT. T/S PER A321 TSM 73-25-00-810-A00-A WILL NEED EIU P/N: 777461-1-1 . EIU-1 (1KSI) INOP. REMOVED AND REPLACED NBR 1 EIU PER A321 AMM 73-25. OPS CKS GOOD. S/W VERIFIED CURRENT
Part: NONE — NONE · airframe 11,024 hrs · 2,484 cycles
ETOPS - ENG 2 EIU FAULT // REMOVED AND REPLACED ENGINE SEL SW (6KS) PER TSM 73-25-00-810-425A & PERFORMED OPS TEST OF EIU 1 AND 2 PER AMM 73-25-34. OPS GOOD. 6/27/22 19845. PENDING ENGINE RUN. PERFORMED ENG 1 & 2 IDLE RUN. CHECK GOOD. NO FAULTS. OK FOR SVC.
Part: NONE — NONE · airframe 11,023 hrs · 2,481 cycles
ETOPS - "ENG 1 OIL CHIP DETECTED" NOTIFICATION ON ROLLOUT // MSG GONE UPON GATE ARRIVAL. INSPECTED MAGNETIC CHIP COLLECTORS AND FOUND TO BE WITHIN LIMITS. INSPECTED OIL FILTER AND FOUND NO DEBRIS. REPLACED OIL FILTER AS PRECAUTIONARY. RAN ENG#1 UNABLE TO DUPLICATE MSG. CONT'D ON 868487-2. OKAY TO CONTINUE REF TSM 79-35-00-810-808-A. NOTE: CHIP CHECK CARDS ROUTED TO JET-CARE.
2021
Part: NONE — NONE · airframe 8,620 hrs · 1,873 cycles
INFO TO MX: APPROX 1.5 HRS INTO FLIGHT A CONT. LOUD SQUEALING NOISE BEGAN. SEEMED TO BE COMING FROM COCKPIT DOOR. FA COULD HEAR IN FWD GALLEY. WE DID AN ENROUTE CLB + NOISE STOPPED AT 700 FT ABOVE ORIGINAL CRUISE ALT. // FOUND FENOLIC STRIP BENT ON TOP OF 1R DOOR. RE-SECURED. PRESSURIZED A/C PER AMM 05-53-00-780-002-A-01. TO 7.8 PSI, NO LEAKS DETECTED. OK FOR SVC.
Part: FIRE LOOP — FALSE ACTIVATION (NR 1) · airframe 8,536 hrs · 1,849 cycles
ETOPS - 3 MIN AFTER TO AND AGAIN 4 MIN AFTER TO ECAM ENG 1 FIRE LOOP B FAULT. ACCOMPLISHED ECAM PROCEDURE AT SOMEPOINT DURING FLIGHT THAT STATUS MESSAGE FIRELOOP B DISAPPEARED // PERFORMED TSM 26-12-00-810-84-A. FOUND ENG 1 FIRE LOOP B FWD AND AFT OUT OF VALUES. R/R AFT AND FWD LOOP B IAW AMM 26-12-00. ALL TEST OK. NO FAULTS AT THIS TIME. A/C OK FOR SERVICE
Part: PUMP — DEFECTIVE (FUEL SYSTEM) · airframe 7,224 hrs · 1,587 cycles
ETOPS - FUEL L TK PUMP 2 LO PR DISPLAYED ON ECAM DURING CRUISE AT FL370 WITH 1HR15MINS REMAINING IN FLIGHT. FUEL TEMP 19C. // TROUBLESHOT FUEL L TK PUMP 2 LO PR PER A321 TSM 28-21-00-810-828-A. COMPLIED WITH STEPS (2) TRU (20). NO DEFECTS NOTED. (DL783821). REMOVE AND REPLACED L TK 2 PUMP PER A321 AMM 28-21. LEAK CK AND OPS CK GOOD. C/W SFAR88 INSTRUCTIONS.
2020
Part: PIN — DETACHED (R2 DOOR) · airframe 6,275 hrs · 1,368 cycles
EMERGENCY EQUIPMENT, 2R DOOR STRING/SAFETY PIN NOT ATTACHED TO DOOR. RESECURED 2R SAFETY PIN. SECURITY CHECK OK.
Part: LIGHT — MISSING (CABIN) · airframe 6,273 hrs · 1,361 cycles
EMERGENCY EQUIPMENT, STRIP OF PATHWAY LIGHTING MISSING NEAR AFT OF A/C. REMOVED & REPLACED PHOTOLUMINESENT STRIP-FLOOR-PROXIMITY EMERGENCY ESCAPE PATH-MARKING REFERENCING AMM 33-51-21. OK FOR SERVICE.
Part: SHUTOFF VALVE — LEAKING (FUEL SYSTEM) · airframe 5,961 hrs · 1,168 cycles
ETOPS SIGNIFICANT SYSTEM - FOUND FUEL LEAKING PASS LP SHUT OFF FUEL VALVE ON # 2 ENGINE. // REMOVED AND REPLACED LP SHUT OFF FUEL VALVE PER AMM 28-24-41-400-001-A ON # 2 ENGINE OPS AND LEAK CHECK GOOD.
Part: TRANSDUCER — MALFUNCTIONED (BLEED AIR SYS) · airframe 5,961 hrs · 1,168 cycles
ETOPS SIGNIFICANT SYSTEM - AIR BLEED MESSAGE ON ECAM. // REMOVED AND REPLACED BLEED DIFFERENTIAL PRESSURE TRANSDUCER ON # 1 ENGINE. BITE TEST OKAY, OKAY TO CONTINUE.
Part: APU — SHUTDOWN · airframe 5,619 hrs · 1,099 cycles
ETOPS SIGNIFICANT SYSTEM - X2 APU SHUTDOWN DURING START. // RESTART APU BY EXTERNAL POWER PER AMM 49-00-00-860-008-A. OPS CHECK OKAY OK FOR SERVICE. NO ISSUE NOTED
Part: UNKNOWN — ODOR (CABIN) · airframe 5,597 hrs · 1,093 cycles
OPEN - FUMES, DIRTY SOCK SMELL ON DESCENT THROUGH 4000'. REPEAT WRITE-UP, FUME FORM FILLED OUT. // FERRY FLIGHT REQUIRED. THIS AIRCRAFT HAS BEEN INSPECTED THIS DATE AND IS SAFE FOR THE INTENDED FLIGHT.
Part: ENGINE — VIBRATION (NR 1) · airframe 5,422 hrs · 1,058 cycles
ETOPS SIGNIFICANT SYSTEMS - ECAM ENG 1 - ENG VIB. BTB. NR 1 ENGINE REPLACEMENT. REMOVED NR 1 ENGINE S/N P770609 AND INSTALLED NR 1 ENGINE S/N P770677, PER W/O 172866 TASK CARD J321-72-HWI-02.
2019
Part: SENSOR — MALFUNCTIONED (A/C PACK TEMP) · airframe 5,191 hrs · 1,013 cycles
ETOPS SIGNIFICANT SYSTEM - ECAM AIR PACK 2 OVHT 37 MIN INTO FLIGHT @FL320. FOLLOWED ECAM PROC. AFTER COOL DOWN TURNED PACK BACK ON. FAILED AGAIN. LEFT PACK 2 OFF.// PERFORMED TSM 21-61-00-810-802-A, CLEANED TEMP SENSOR 32HH & 34HH, CONDITION IMPROVED, NO OVER HEAT MESSAGE. REMOVED AND REPLACED SENSOR 32HH, REF AMM 21-61-11. LEAK CHECK GOOD, BUT FAILED 34HH ON BITE TEST. REMOVED AND REPLACED PACK OUTLET TEMP SENSOR 34HH PER AMM 21-61-15, OPERATIONAL TEST OK, OK FOR SVC.
Part: CHECK VALVE — LEAKING (APU) · airframe 5,185 hrs · 1,012 cycles
ETOPS SIGNIFICANT SYSTEM - BTB ECAM APU BLEED LEAK AFTER ENGINE START FOLLOWED BY APU LEAK FED BY ENGINES, INTERMITTENT FAULT LIGHT ON ENG 1 BLEED SWITCH. // INSPECTED APU COMPARTMENT, CARGO BAY PANEL AFT COMPARTMENT AND THE COMPARTMENT DUCTS FOR ANY BLEED LEAK. REMOVED AND INSPECTED APU CHECK VALVE FOR CONDITION PER AMM 36-12-51-200-0001A, CONDITION OK. BMC-1 REMOVED AND REPLACED PER AMM 36-11-34. BITE TEST BAD, CONDITION SAME. REPLACED BULKHEAD CONNECTOR & SENSING ELEMENT (16HF) OPS CHECK GOOD PER AMM 36-22-00-710-802-A. OK FOR SERVICE. FOUND APB FEED THRU CONNECTOR FOR APU BLEED LEAK DETECTION LOOP HAS LOW INSULATION TO GROUND (600 OHMS). CONNECTOR IS BETWEEN ELEMENT 16HF & 17HF. REMOVED AND INSTALLED SENSING ELEMENT 16HF PER AMM 36-22-17. OPS CHECK GOOD PER AMM 36-22-00-710-802-A. OK FOR SERVICE.
Part: OIL SYSTEM — LOW (APU) · airframe 4,588 hrs · 895 cycles
ETOPS SIGNIFICANT SYSTEM - UPON APU START LOW OIL LEVEL ADVISORY. APU RUN FOR 30 MINUTES. // SERVICED APU WITH 2PT. OIL. QUANTITY CHECK GOOD. NO FAULTS NOTED AFTER APU START. REF. AMM 12-13-49-612-001-A O.K. TO CONTINUE.
Part: FIRE DETECTOR — FAULTY (NR 2 ENGINE) · airframe 3,738 hrs · 727 cycles
ETOPS / DURING CLIMB ENG 2 FIRE LOOP FAULT ILLUMINATED, WENT OUT AFTER 1 MINUTE. REMOVED AND REPLACED #2 ENGINE PYLON FIRE DETECTORS (3WD2) AND (4WD2) PER AMM 26-12-16.
Part: FDU — FAULTED (NR 2) · airframe 3,728 hrs · 725 cycles
ETOPS / IN CRUISE ENG 2 FIRE LOOP B FAULT. // PERFORMED TSM 26-12-00-810-806-A AND TSM 26-12-00-810-826-A. ENG 2 FIRE LOOP B RESISTANCE CHECK IS SATISFACTORY. VISUAL CHECK IS GOOD. FDU 2 BITE TEST GAVE "CHK FDU ENG2 CHAN B SPLY." REMOVED AND REPLACED FDU2.
Part: VALVE — MALFUNCTIONED (BLEED AIR SYS) · airframe 3,489 hrs · 678 cycles
ETOPS SIGNIFICANT SYSTEM - ENG 1 BLEED FAULT. REMOVED & REPLACED FAN AIR VALVE PER AMM 36-11-54-000-803-A & AMM36-11-54-400-803-A. OP'S CHECK GOOD. OK TO CONT SERVCE.
Part: UNKNOWN — MALFUNCTIONED (WEATHER RADAR) · airframe 2,984 hrs · 579 cycles
ETOPS SIGNIFICANT SYSTEM - ERRONEOUS HAZARD DISPLAY ON RADAR. 40NM RANGE. GREEN "CLOUD" AND MANGENTA "TURB" DISPLAYED IN CLEAR SMOOTH AIR. AUTO SETTINGS. PERFORM BITE TEST OF WEATHER RADAR PER AMM 34-41-00. OPS CHECK GOOD. OK FOR SERVICE.
Part: PRESSURE SWITCH — FAILED (HYD PUMP) · airframe 2,845 hrs · 552 cycles
ETOPS SIGNIFICANT SYSTEM - ECAM HYD BLUE ELEC PUMP LO PR CAME ON IN FLIGHT. PERFORMED ECAM ACTIONS AND PROCEED FLIGHT WITH BLUE PUMP MANUALLY OFF. // REMOVED AND REPLACED BLUE ELECTRIC PUMP PRESSURE SWITCH IAW AMM 29-12-17-000-001-A. OPS CHECK GOOD OK FOR SERVICE.
Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 2,368 hrs · 461 cycles
ETOPS SIGNIFICANT SYSTEM - BTB. AFTER ENGINE START, STATUS PAGE ECAM MSG. INOP SYS: A/THR CAT 3 APPEARED. PERFORMED AMM 22-96-00 & AMM 22-30-00. OPS CK OK. OK FOR SERVICE.
Part: UNKNOWN — ODOR · airframe 2,238 hrs · 436 cycles
FUMES/ODORS LIKE DIRTY WET SOCKS DURING DESCENT THRU 14000, ALL THE WAY TO THE GATE. // PERFORMED TSM 05-50-00-810-831-A. RAN #1 AND #2 ENGINES AND ISOLATED APU BLEED AND RAN EACH PACK INDIVIDUAL. NO ODOR NOTED IN CABIN OR COCKPIT. OK TO CONTINUE.
Part: CONNECTOR — BROKEN (GALLEY) · airframe 1,997 hrs · 389 cycles
JUST BEFORE LANDING, STRONG ELECTRICAL BURNING SMELL IN THE AFT GALLEY. THE SMELL WENT AWAY AFTER LANDING. // TROUBLESHOT ELECTRICAL ODOR IN AFT GALLEY PER TSM 05-50-00-810-831-A. FOUND MOST LIKELY CAUSE TO BE MISCELLANEOUS. OPERATED ALL EQUIPMENT IN AFT GALLEY, COFFEE MAKERS, OVENS, TRASH COMPACTOR, LIGHTING, NO DEFECTS NOTED. INSPECTED BEHIND AFT GALLEY. NO DEFECTS NOTED. INSPECTED TRASH COMPACTOR FOUND BACK SHELL BROKEN, REMOVED AND REPLACED TRASH COMPACTOR BACK SHELL P522 PER ASM 25-33-32. PER 25-35-00 OK FOR SERVICE. REF 20-44-00(ESPM) FOR CONNECTOR OPS CHECK GOOD. REMOVED, INSPECTED, AND REINSTALLED OVENS. NO DEFECTS NOTED. REF AMM 25-35-19. OK FOR SERVICE.
2018
Part: SMOKE WARNING — FALSE ACTIVATION (LAVATORY) · airframe 1,311 hrs · 257 cycles
DURING CLIMB AT FL320 ECAM SMOKE LAVATORY SMOKE. WENT OUT AFTER ONE MINUTE. NO REPORT OF ANY SMOKE.// PERFORMED OPS CHECK OF LAV SMOKE DETECTION SYSTEM PER AMM 26-17-00-710-001-A. OPS CHECK GOOD. OKAY FOR SERVICE.
Part: FAULT MESSAGE — FALSE ACTIVATION (NR 2 IGNITION) · airframe 1,125 hrs · 221 cycles
ETOPS SIGNIFICANT SYSTEM - BTB ENG 2 IGN A FAULT.// PERFORMED GROUND SCAN OF EEC 2A/B - NO FAULTS ASSOCIATED WITH IGN A FAULT. PERFORMED EEC 2A/B SYSTEM TEST - TESTS OK (NO FAULTS ASSOCIATED W/ ENG 2 IGN A FAULT. REFERENCE TSM 73-25-00-810-A80-A. CREW PERFORMED SUCCESSFUL ENGINE START ON "A" SYSTEM AT GATE. OK FOR SERVICE.
Part: IGNITION SYS — FAULTED (NR 2 ENGINE) · airframe 1,100 hrs · 216 cycles
ETOPS SIGNIFICANT SYSTEM - ENG 2 IGNITION A SYS FAULT DURING START.// PERFORMED IGNITER AUDIBLE TEST PER AMM 74-00-00-710-802-A. OPS CHK OK. PERFORMED TASK CARD E1128-321-74-004. OPS NORMAL. OK FOR SVC.
Part: WARNING SYSTEM — ACTIVATED (COCKPIT) · airframe 992 hrs · 195 cycles
OPEN - DIVERSION - ETOPS SIGNIFICANT SYSTEM - ENGINE 1 LOOP B ECAM. AIRCRAFT DIVERTED TO THE NEAREST STATION, WHERE AN UNEVENTFUL LANDING WAS MADE. REPAIR IN WORK.
Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 906 hrs · 178 cycles
ETOPS SIGNIFICANT SYSTEM - INFO TO MAINTENANCE, UPON STARTING ENG NR 2 GOT ECAM ENG 2 START FAULT AND ENG 2 IGN A FAULT, PER MAINT. REQUEST WE RESET A3 AND Q40 CIRCUIT BREAKERS. AFTER CIRCUIT BREAKERS RESET AND RESTART ENG NR 2 FAULT CLEARED. PERFORMED OPERATIONAL TEST OF ENG NR 2 IGNITION SYSTEM PER AMM 74-00-00-710-802-A. IGN A AND B SYSTEM TESTED OK. NO FAULTS NOTED. OK FOR SVC.
Part: WARNING MESSAGE — FALSE ACTIVATION · airframe 325 hrs · 65 cycles
DURING START OF THE NR 2 ENGINE, ING FAULT APPEARED. PERFORMED TASK 73-25-00-810-A45-A, NO FAULTS FOUND. CREW RAN THE NR 2 ENGINE, CYCLED A & B WITH NO FAULTS. OK FOR SERVICE.
Part: IGNITER — INOPERATIVE (NR 2 ENGINE) · airframe 177 hrs · 36 cycles
NR 2 ENGINE IGNITER A SYSTEM INOPERATIVE. R & R THE IGNITER PLUG ON ENG#2 SYSTEM A. PER AMM 74-21-01. PERFORMED OPS CHECK, OPS CHECKS GOOD. A/C OK FOR SERVICE.