N220JQ

EMBRAER ERJ 170-200 LR · 2007 · Fixed-wing multi-engine · 2 engines · 88 seats · Valid Registration

Registered owner: DELTA AIR LINES INC, GA (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

10 reports on file, 2020-12-04 – 2024-11-09.

OTHER · 2024-11-09 Matched by certificate designator
ATA 5310

Part: CROSSBEAM — CORRODED (ZONE 200) · corrosion level 2 · airframe 40,417 hrs · 26,360 cycles

WHILE IN HEAVY CHECK - COCKPIT FLOOR STRUCTURE - FR 11 CENTER CROSS BEAM AREA HAS AREAS OF CORROSION INCLUDING CENTER TRIANGLE PLATE. INSTALLED NEW REPAIR DOUBLERS AT FRAME 11 CROSS BEAM AT CENTER AREA. REF ETD2024-170-029132

Source: SDR R61A2024110900534
OTHER · 2024-11-09 Matched by certificate designator
ATA 5730

Part: SKIN — CRACKED (ZONE 600) · airframe 40,417 hrs · 26,360 cycles

WHILE IN HEAVY CHECK - SUSPECTED CRACK RH WING RIB 4A AS MARKED. REPAIRED CRACK IN RH WING BY PERFORMING CUT OUT AND INSTALLING A REPAIR DOUBLER PER ETD-2024-170-028830.

Source: SDR R61A2024110900532
OTHER · 2024-11-09 Matched by certificate designator
ATA 5310

Part: CROSSBEAM — CORRODED (ZONE 100) · corrosion level 2 · airframe 40,417 hrs · 26,360 cycles

WHILE IN HEAVY CHECK - FWD WET AREA FLOOR STRUCTURE - CROSS BEAM RH SIDE AT FR 17 HAS AREAS OF CORROSION ON UPPER SURFACE. PERFORMED CUT OUT TO DAMAGED AREA ON FWD WET AREA FLOOR STRUCTURE - CROSS BEAM RH SIDE AT FR 17. REF EMB SRM 53-00-10/REPAIR 03P. INSTALLED DOUBLER REPAIR (INNER DOUBLER, SHIMS, & FILLER PLATE) ON RH SIDE OF FR 17 CROSS BEAM OF FWD WET AREA FLOOR STRUCTURE. REF EMB SRM 53-00-10/R03.

Source: SDR R61A2024110900533
OTHER · 2024-03-15 Matched by certificate designator
ATA 3150

Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 39,186 hrs · 25,425 cycles

CREW REPORTS BRAKE OVERHEAT ON LANDING, HIGHEST TEMP REPORTED #1 BRAKE AT 490. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. FOUND TO BE EXTREME CONDITIONS OF BRAKE ASSEMBLY, NO DEFECTS NOTED.

Source: SDR R61A2024031800121
OTHER · 2023-04-25 Matched by certificate designator
ATA 3350

Part: UNKNOWN — UNKNOWN (ZONE 800) · airframe 37,440 hrs · 24,114 cycles

MAIN CABIN DOOR WILL NOT OPEN. REMOVED DEBRIS FROM GIRT BAR ANCHOR POINTS.

Source: SDR R61A2023042600250
OTHER · 2023-01-16 Matched by certificate designator
ATA 5330

Part: SKIN — DAMAGED (FRMS 5-6 S23-24R) · airframe 36,874 hrs · 23,630 cycles

RH FWD FUSELAGE SKIN BURN BETWEEN FR 5-6 AND STGR 24R-23R DUE TO LIGHTNING STRIKE. REPAIRED PER ETD 2023-170-001224

Source: SDR R61A2023011800064
OTHER · 2021-12-16 Matched by certificate designator
ATA 5300

Part: DOOR SILL — CORRODED (ZONE 200) · airframe 34,784 hrs · 22,088 cycles

CORROSION IN CENTER OF AFT PAX DOOR SILL AS MARKED. REMOVED AND REPLACED AFT PAX DOOR SILL FWD AND AFT SEAL REST REF SRM 51-40-08.

Source: SDR R61A2021121601019
OTHER · 2021-11-22 Matched by certificate designator
ATA 5101

Part: SHEAR ANGLE — CORRODED · airframe 34,784 hrs · 22,088 cycles

CORROSION ON SHEAR CLIP AT FR 86 BETWEEN STG 27R-28R. REMOVED AND REPLACED SHEAR CLIP AT FR 86BEWTWEEN STRINGER 27R-28R. REF EMB SRM 51-40-08.

Source: SDR R61A2021112900934
OTHER · 2021-05-22 Matched by certificate designator
ATA 5240

Part: HANDLE — LACK OF LUBE (R1 DOOR) · airframe 33,559 hrs · 21,188 cycles

R1 DOOR DISARM HANDLE HARD TO DISARM, GETS STUCK HALF WAY. CLEANED AND LUBED R1 DOOR DISARM HANDLE LINKAGE. OPS CHECK GOOD.

Source: SDR R61A2021052500444
OTHER · 2020-12-04 Matched by certificate designator
ATA 3397

Part: CONNECTOR — DISCONNECTED (EMERGENCY LIGHTS) · airframe 32,593 hrs · 20,403 cycles

FWD MOST EMERGENCY LIGHT INOPERABLE. DURING REMOVAL OF CEILING PANEL, FOUND EMERGENCY LIGHT CONNECTION TO BE OFF. RECONNECTED EMERGENCY LIGHT AND PERFORMED OPERATIONS CHECK, IAW AMM 33-50-00.

Source: SDR R61A2020120800856