HARD BOIL EGG/SULFUR SMELL DURING START OF DESCENT FROM FL240, SLOWING DOWN, AND APU START FOR APPROX 1 MINUTE AT A TIME. PRESSURIZED AT THE TIME OF FIRST SMELLING ODOR. FAS DID A SWEEP THROUGH OF CABIN, NO ONE WAS EATING EGGS AND THERE WE'RE NONE IN THE OVERHEAD COMPARTMENTS. THEY WE'RE ADAMANT NO ONE WAS PASSING GAS AND NOTHING IN THE LAVS OR GARBAGE CAN FOLLOWED FIM 21-20-00-810-801-A STEPS AND COULD NOT DUPLICATE SMELL. ALSO RAN BOTH ENGINES FOR 10 MINS WITH PACK AND BLEED OPEN. WALKED UP AND DOWN THE AISLES COULD NOT DUPLICATE SMELL. TRIAD RELEASED ACFT OKAY FOR SERVICE.
RH FWD EMERGENCY PHOTOLUMINESCENT END INDICATOR NEAR FWD CLOSET IS INOP RAR RH FWD EMERGENCY PHOTOLUMINESCENT END INDICATOR IAW AMM 33-50-21/400. OPC GOOD
DWMS NRTC F022149 - RH FWD CENTER FLOOR BEAM HAS CORROSION AHEAD OF THE SEAT TRACK. (LEVEL 2 CORROSION) (MAJOR REPAIR) REPAIRED RH FWD CENTER FLOOR BEAM IAW ERS EJ-53MR-5126.
MULTIPLE EMERGENCY PHOTOLUMINESCENT LIGHT STRIPS ARE DAMAGED COMPLETE:REPLACED OR REPAIRED MULTIPLE PASSENGER CABIN PHOTOLUMINESCENT INDICATOR STRIP LIGHTS I.A.W. EMB175 A.M.M. 33-50-21.
FOUND FWD EMERGENCY EXIT IDENTIFIER SIGN INOP-C/A-RAR FWD LH EMERGENCY LIGHT POWER SUPPLY UNIT IAW AMM 33-50-01. OPC GOOD.
#1 EMERGENCY LIGHT POWER SUPPLY FAILED FUNCTIONAL CHECK OF W/C 33-50-01-001-C/A-RAR #1 EMERGENCY LIGHT POWER SUPPLY IAW EMB AMM 33-50-01 OPERATIONAL CHECK GOOD
SSI 53-23-005 AFT GALLEY RH BEAM SPLICE CORRODED AT FR 90 (LEVEL 2 CORROSION)-C/A-RAR AFT GALLEY RH BEAM SPLICE AT FR 90 IAW EMB 175 SRM 51-40-08
SSI 53-23-005 AFT GALLEY RH PANEL SUPPORT CORRODED AT FR 89 (LEVEL 2 CORROSION)-C/A-RAR AFT GALLEY RH SUPPORT AT FR 89 IAW EMB 175 SRM 51-40-08
FOUND RH CENTER FLOOR BEAM TO HAVE CORRODED GUSSET PLATE AT FR 90 (LEVEL 2 CORROSION)-C/A-RAR RH CENTER FLOOR BEAM GUSSET PLATE AT FR 90 IAW EMB 175 SRM 51-40-08
SSI: LH CENTER FLOOR BEAM IS CORRODED JUST FWD OF SEAT TRACK AT FR 19A MAJOR REPAIR (LEVEL 2 CORROSION)-C/A-REMOVED AND INSTALLED A SERVICEABLE LH CENTER SEAT TRACK BEAM AT FR 19A IAW EMB 175 SRM 51-40-08
SSI: 53-32-005 AFT GALLEY FLOOR RH SHEAR PANEL CORRODED BETWEEN FR 87-88 (MARKED) (LEVEL 2 CORROSION)-C/A-RAR AFT GALLEY RH SHEAR PANEL BETWEEN FR 87-88 IAW EMB 175 SRM 51-40-02, EMB 175 SRM 51-40-08 AND EMB 175 SRM 51-21-02.
5EA PHOTOLUMINESCENT FLOOR LIGHT STRIPS ARE DAMAGED-C/A-COMPLETE:REMOVED AND REPLACED ALL BROKEN (5EA) PHOTOLUMINESCENT FLOOR LIGHT STRIPS IAW EMB 175 AMM 33-50-21. OPS CHECK GOOD.
RH WING TIP SPAR 1 IS CRACKED. (INSIDE 651AB)-C/A-COMPLETE:SEE NRTC E904836** ONETIME REPLACEMENT - EO-EJ-5700-004 OPS PTB DUE FOR REPLACEMENT OF RH WING TIP SPAR 1
RH WING OUTBD SPAR 1 IS CRACKED.-C/A-COMPLETE:RAR RH WING OUTBOARD SPAR 1 IAW EMB 175 SRM 51-40-08, SRM 51-43-03, SRM 51-43-04, AND SRM 51-41-02.
LH WING TIP SPAR 1 IS CRACKED. (INSIDE 551AB)-C/A-COMPLETE:SEE NRTC E904835** ONETIME REPLACEMENT - EO-EJ-5700-004 OPS PTA DUE FOR REPLACEMENT OF LH WING TIP SPAR 1
ON FINAL APPROACH TO ORD STEER FAIL ON EICAS UPON GEAR EXTENSION. LANDED W/OUT INCIDENT AFTER DECLAREDL EMERGENCY W/A NLG FAIL MSG. -C/A-HARD FAULT AND WOULD NOT RESET. RAR SHORTED STEERING FEEDBACK SENSOR #2 IAW EMB 175 AMM 32-53-09. ADJUSTMENT/TEST GOOD.
CREW REPORTS- FOUND PASSENGER DOOR HARD TO OPEN-C/A-FOUND LH ROLLERS STICKING. LUBRICATED ROLLERS AS REQUIRED. NO OTHER DEFECTS NOTED.
#2 ENGINE LP VIBRATION IN AMBER. 4.0 AT 15,000 FT -24,000- DECLARED EMERGENCY-OVERWEIGHT LANDING 80,000 LBS - 100 FPM- EQP CHANGE FLT CONT. -C/A-DEFERRED PER GE MM REF LMM 72-21-00-800-806 TDMI AUTHORIZATION NUMBER 026T72122.NO INSPECTIONS NEEDED FOR SINK RATES LESS THAN 360 FPM IAW E-175 AMM OVERWEIGHT LANDING INSP/ CHECK 05-50-27. NO MTX ACTION REQUIRED AT THIS TIME.
AT APROX 8000 FT WHILE DESCENDING CA RA CAME UP TO APPROX 800 FT AND AURAL LANDING GEAR WARNING SOUNDED. C/A T/S RA, IAW FIM 22-11-00 BLOCK DIAGRAM 1 BLOCKS 1,2,3, AND 12. PERFORMED OPS CHECK, IAW AMM 34-31-00. OPS CHECK GOOD. CMC CODE (22110115FA1).
COCKPIT OVERHEAD PANEL FWD BEAM BETWEEN FR08 AND FR11 STR01L AND STR 03L BENT ALONG TOP HALF OF LEFT UPPER SIDE. REMOVED AND REPLACED FWD COCKPIT OVERHEAD PANEL BEAM IAW EMB 175 SRM 51-40-02, 51-41-01, 51-41-02
COCKPIT OVERHEAD PANEL BEAM BETWEEN FR08 AND FR11 STR 01L AND STR 03L BENT ALONG FULL LENGTH AND CRACKED AT AFT END. REMOVED AND REPLACED LH OVERHEAD COCKPIT PANEL BEAM IAW EMB 175 SRM 51-40-02, 51-41-02
OVERHEAD COCKPIT PANEL FWD BEAM BETWEEN FR08 AND FR11 STR01L AND STR 03L BENT ALONG TOP HALF OF LEFT UPPER SIDE. REMOVED AND REPLACED FWD COCKPIT OVERHEAD PANEL BEAM IAW EMB 175 SRM 51-40-02, 51-41-01, 51-41-02
AFT COCKPIT OVERHEAD PANEL BEAM BETWEEN FR08 AND FR11 STGR 01L AND STGR 03L BENT ALONG TOP RH UPPER HALF "MAJOR REPAIR"-C/A-REMOVED AND REPLACED AFT OVERHEAD COCKPIT PANEL BEAM IAW EMB 175 SRM 51-40-02, 51-41-01, 51-41-02
FWD COCKPIT OVERHEAD PANEL BEAM BETWEEN FR08 AND FR11 STGR 01L AND STGR 03L BENT ALONG TOP HALF OF THE LEFT UPPER SIDE "MAJOR REPAIR"-C/A-REMOVED AND REPLACED FWD COCKPIT OVERHEAD PANEL BEAM IAW EMB 175 SRM 51-40-02, 51-41-01, 51-41-02
LH COCKPIT OVERHEAD PANEL BEAM BETWEEN FR08 AND FR11 STGR 01L AND STGR 03L BENT ALONG FULL LENGTH AND CRACKED AT AFT END "MAJOR REPAIR"-C/A- REMOVED AND REPLACED LH OVERHEAD COCKPIT PANEL BEAM IAW EMB 175 SRM 51-40-02, 51-41-01, 51-41-02
GATE AGENT HAD IUSSUES / DIFFICULTY OPENING MAIN CABIN DOOR. C/A-CLEANED MAIN PAX DOOR ROLLERS AND GUIDES IAW STD MTX PRACTICES. NO FURTHER DEFECTS NOTED AT THIS TIME.
ON INITIAL CLIMB AND ALL DECENTS, A STRONG ODER OF DIRTY SOCKS AND MUSTY AIR WAS PERSISTANT CATEGORY A, FLIGHT DECK. DISCOVERED COMPRESSOR WASH WAS C/W ON BOTH ENGINES PRIOR TO THIS LEG. C/W FIM 21-20-00-810-009-A. ALSO RAN AIRCRAFT AT NUMEROUS POWER, BLEED AND PACK SETTINGS. NO DEFECTS NOTED. ALL SMELLS HAVE DISSIPATED. A/C OK FOR SERVICE.
1 DENT AT AFT JACK POINT BETWEEN FRAME 92-92. C/A-PERFORMED PERMANENT REPAIR OF DENT AT AFT JACK POINT BETWEEN FRAME 92-93 IAW ERS-EJ-53MR-3681.
BLEED 2 LEAK ILLUMINATED IN FLIGHT. RAN QRH RETURNED TO DEPARTURE. BLEED 1 FAIL ILLUMINATED IN FLIGHT RAN QRH EICAS MSG WENT AWAY BUT YELLOW X ON SYSTEMS PAGE OVER BLEED 1 VALVE. BLEED 1 FAIL ILLUMINATED AGAIN AFTER LANDING "TRANSFERRED TO NRWC 026-DFW-01018" -C/A- REMOVED AND REPLACED RH ENG. PRECOOLER OUTLET DUCT GASKET IAW 36-11-08, AND PERFORMED OP CK OF THE RH ENGINE PNEUMATIC BLEED SYSTEM IAW E-175 AMM 36-11-00. OP CHECK GOOD. REMOVED AND REPLACED NACELLE PRESSURE-REGULATING SHUTOFF-VALVE FILTER IAW E175 AMM 36-11-03. PERFORMED OPS CHK OF AIR BLEED SYSTEM IAW E175 AMM 36-00-00-710-801-A. NO BLEED FAULTS MSG NOTICED ON EICAS. OPS CHK GOOD. PERFORMED TAKEOFF/GO-AROUND (TOGA) SWITCH OPERATIONAL TEST IAW E175 AMM TASK 22-11-00-710-801-A, EFFECTIVITY PRIMUS EPIC LOAD 25.7
"TRANSFERRED FROM NRWC 026-DFW-01025 ITEM 1" REF TO NRWC 026-DFW-01024. STRINGER 29L BETWEEN FRAMES 92 AND 93 IS DAMAGED WITH POSSIABLE CREASE OR CRACK. PICTURES SENT TO ENG. MAJOR REPAIR. C/A-COMPLIED WITH ERS-EJ-53MR-3681.
REF ITEM 1 LBPG 4431774 E2 AFT CORE COWL ACOUSTIC SKIN CRACKED AT TRAILING EDGE 1 " LONG-C/A-REMOVED AND REPLACED RH ENGINE I/B T/R ASSY IAW EMB 175 AMM 78-30-01. OPS CHECKS GOOD
BLEED 2 LEAK CAUTION MESSAGE DURING CLIMBOUT. BLEED 1 FAIL 2 MINUTES AFTER RECEIVING BLEED 2 LEAK MESSAGE. FAULT CODE: 36112210AM2. R&R NR 2 ENG NACELLE PRSOV IAW AMM 36-11-03, OPS CHK AND LEAK CHK GOOD. FAULT CODE: 36115002AM2 FOUND E1 FAN AIR VALVE EXHAUST DUCT DAMAGED. R&R EXHAUST DUCT IAW AMM 36-11-09, OPS CHECK AND LEAK CHECK GOOD.
DENT WITH GOUGE FWD OF FRAME 83, AFT OF AFT WIFI ANTENNA. C/A-ACCOMPLISHED PERMANENT REPAIR TO DENT WITH GOUGE FWD OF FRAME 83, AFT OF AFT WIFI ANTENNA IAW ERS-EJ-53MR-3594.
LAV SMOKE WARNING MSG AT 36000. LASTED ABOUT 20 SECONDS. FA SAID NOTHING ABNORMAL. -C/A-ACCOMPLISHED LAV SMOKE DETECTOR SYSTEM TESTING AND OPERATIONAL CHECK AND DID NOT FIND ANY FAULTS IAW AMM AMM 26-14-01 OPC GOOD.
AFT SERVICE DOOR EXIT SIGN INOPERATIVE. TROUBLESHOT THE AFT SERVICE DOOR SIGN IAW WM 33-50-50 AND FOUND NO POWER TO PIN -M- ON P0546 FOR THE NR 4 EMERGENCY LIGHT POWER UNIT. REMOVED AND REPLACED THE NR 4 EMERGENCY LIGHT POWER UNIT IAW AMM 33-50-01, OPS CHECKED GOOD.
ON LANDING, THE FIRST OFFICER NOTICED THAT THE FA FLASHLIGHT WAS INOPERATIVE DURING THE WALK AROUND POST FLIGHT. IT SHOWS AS CHARGING BUT IS DEAD. REMOVED AND REPLACED THE FLASHLIGHT IAW AMM 33-51-04. OPS CHECKED GOOD.
DURING CLIMB OUT, AFTER NOSE GEAR ROTATED, A PULSATING VIBRATION FELT ON COCKPIT FLOOR. AFTER LEVEL FL280 AND DESCENT STILL FELT VIBRATION BUT NOT AS BAD. RT NOSE TIRE ASSY OUT OF ROUND. PERFORMED NLG AND DOORS INSPECTION IAW AMM 32-20-00. NO DEFECTS NOTED. FOUND LT NOSE TIRE ASSY OUT OF ROUND. REMOVED AND REPLACED THE LT NOSE TIRE ASSY IAW 32-49-01-000-801-A. REMOVED AND REPLACED THE RT NOSE TIRE ASSY IAW WC 32-49-01-000-801-A.
LEVELING OFF AT FL370, E1 LPVIB IND 4.0, REDUCED THROTTLE AND IT REDUCED TO 3.0. RAN THE QRH CHECKLIST AND MADE PRECAUTIONARY LANDING. PERFORMED ESM 72-00-00 SUBTASK 72-00-00-700-801. FOUND THE NR 1 ENGINE TO BE OPERATING WITHIN LIMITS. OPS CHECKED GOOD.
RIGHT AND LEFT MLG AFT TRUNNION BEARING RETAINER PLATE TOP BOLT BROKEN. PERFORMED A PERMANENT REPAIR.
FWD FLASHLIGHT IN CABIN NOT WORKING. REPLACED THE FLASHLIGHT AND BATTERY IAW AMM 33-50-01 . OPS CHECKED GOOD.
DURING FLT EMERGENCY LIGHTS ON CAUTION ON EICAS. PERFORMED OPERATIONAL TEST OF EMERGENCY LIGHTING IAW AMM33-50-00. OPS CHECKED GOOD
3B FAIL MSG PRESENTED DURING THE DESCENT. DECLARED AN EMER, REPEAT WRITE UP. ACCOMPLISHED WORK SCOPE IAW INSTRUCTIONS & REPLACED EIVM MODULE IAW AMM OPERATIONAL CHECK GOOD. CANNOT DUPLICATE FAIL. REMOVED MAU 3 POWER SUPPLY 2 & INSTALLED INTO MAU 1 POWER SUPPLY 1 POSITION & REMOVED MAU 1 POWER SUPPLY 1 & INSTALLED INTO MAU 3 POWER SUPPLY 2 POSITION. WORK PERFORMED IAW AMM 31-41-02. OPERATIONS CHECKED GOOD. MAU 3 PS2 PN 7024440-1903, SN 1508U310 INSTALLED & MAU 1 PS1 PN 7024440-1903 & SN 07078388 INSTALLED. REMOVED MAU 3 NIC 2 & INSTALLED INTO MAU 1 NIC 2 POSITION & REMOVED MAU 1 NIC 2 & INSTALLED INTO MAU 3 NIC 2 POSITION. WORK PERFORMED IAW AMM 31-41-04 OPERATIONAL CHECKED GOOD. MAU 3 NIC 2 PN 7038231-1902, SN 1509D623 OFF & PN 7038231-1902, SN 1510E024 ON. MAU 1 NIC 2 PN 7038231-1902, SN 1510E024 OFF & PN 7038231-1902, SN 150D623 ON. PREFORMED WIRING INSPECTION AS REQUESTED IAW SWPM 20-62-00, NO DISCREPANCIES NOTED. R & R EVM MODULE IAW MM 77-31-01. OPERATIONS CHECKED GOOD.