N261HC
Registered owner: INTERMOUNTAIN MEDICAL TRANSPORT LLC, UT (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| IHC HEALTH SERVICES, INC. (I7LA) | Certificate holder | — | Matched by certificate designator |
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
IT WAS REPORTED AS THE AIRCRAFT WAS COMING IN FOR A 200-HOUR INSPECTION. A SLIGHT BUMP COULD BE FELT IN FLIGHT; DURING THE INSPECTION, ALL PC LINK ROD ENDS, AND BOLTS WERE INSPECTED, AND THE BLUE UPPER BOLT WAS FOUND TO HAVE A STEP WORN INTO IT, THE BOLT WAS REPLACED, AND MR TRACK AND BALANCE WERE PERFORMED, AND NO FURTHER MAINTENANCE WAS REQUIRED.
DURING A DAILY INSPECTION , A ONE INCH CRACK ON ONE OF THE TWO TAIL ROTOR BLADES WAS DETECTED. INITAL INSPECTION WAS VISUAL A 10X GLASS WAS USED TO VARIFY. AIRCRAFT WAS REMOVED FROM SERVICE AND WILL RETURN TO SERVICE AFTER A SERVICEABLE TAIL ROTOR BLADE IS INSTALLED.