N261HC
Registered owner: INTERMOUNTAIN MEDICAL TRANSPORT LLC, UT (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| IHC Health Services, Inc. (I7LA) | Certificate holder | — | Matched by certificate designator |
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
2 reports on file, 2014-09-25 – 2023-08-10.
Part: BOLT — GROOVED (ZONE 200) · airframe 4,942 hrs · 16,256 cycles
IT WAS REPORTED AS THE AIRCRAFT WAS COMING IN FOR A 200-HOUR INSPECTION. A SLIGHT BUMP COULD BE FELT IN FLIGHT; DURING THE INSPECTION, ALL PC LINK ROD ENDS, AND BOLTS WERE INSPECTED, AND THE BLUE UPPER BOLT WAS FOUND TO HAVE A STEP WORN INTO IT, THE BOLT WAS REPLACED, AND MR TRACK AND BALANCE WERE PERFORMED, AND NO FURTHER MAINTENANCE WAS REQUIRED.
Part: BLADE — CRACKED (TAIL ROTOR) · airframe 1,325 hrs
DURING A DAILY INSPECTION , A ONE INCH CRACK ON ONE OF THE TWO TAIL ROTOR BLADES WAS DETECTED. INITAL INSPECTION WAS VISUAL A 10X GLASS WAS USED TO VARIFY. AIRCRAFT WAS REMOVED FROM SERVICE AND WILL RETURN TO SERVICE AFTER A SERVICEABLE TAIL ROTOR BLADE IS INSTALLED.