N26TA
Registered owner: RYAN AIR INC, AK (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| RYAN AIR, INC. (UATA) | Certificate holder | — | Matched by certificate designator |
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
1 report on file, 2026-08-24.
Part: CONTROL CABLE — MISINSTALLED (ZONE 300) · airframe 22,984 hrs · 54,263 cycles
A POST MAINT FLIGHT CHECK OF ACFT WAS CONDUCTED DUE TO AN ENG CHANGE, PROPELLER CHANGE, MULTIPLE FLT CONTROL SURFACE, CONTROL SURFACE CABLE CHANGES, & AN EXTENDED PERIOD OF DOWN TIME IN MAINT (APPROX. 6YRS.) DUE TO EXTREME CORROSION & OTHER MX ITEMS. AFTER TAKING OFF FOR FLIGHT CHECK, PILOT EXPERIENCED ACFT HAVING A NOSE DOWN TENDENCY. PILOT ADJUSTED ELEVATOR TRIM TO CORRECT ATTITUDE, BUT CONDITION WORSENED. PILOT NOTIFIED ATC THAT HE WOULD NEED TO RETURN TO AIRPORT & IT WAS GRANTED. AIRCRAFT LANDED WITHOUT FURTHER INCIDENT & RETURNED TO MAINT HANGAR. ON INVESTIGATION, DISCOVERED THE ELEVATOR TRIM TAB WAS INSTALLED WITH A TWIST IN THE CABLE RESULTING IN OPERATION OF ELEV TRIM TO BE REVERSED. TWIST IN ELEV CABLE CORRECTED, TRIM ACTUATOR & TRIM CABLE TENSION ADJUSTED IAW MM. CONTROL SURFACES RE-INSPECTED TO VERIFY CORRECT INSTALLATION & OPERATION. SECOND FLIGHT CHECK RESULTED IN SATISFACTORY OPS OF ACFT.