AISLE CEILING EMERGENCY LIGHT AT ROW 3 INOPERATIVE. REMOVED AND REPLACED CEILING EMERGENCY LIGHT AT ROW 3. OPS CHECK SAT.
VISIBLE SMOKE FROM THE FO SIDE WINDOW AREA UNDER THE PTT BUTTON PANEL. REMOVED, INSPECTED AND REINSTALLED RH SIDE CONSOLE. NO DEFECTS NOTED. REMOVED GLARESHIELD AND FOUND FOS WS HEATING SENSORS TERMINAL G LOOSE AND BURNT. PERFORMED FIM. FOUND FO WINDSHIELD HEATING SENSOR GROUND TERMINAL LOOSE AND BURNT. FOUND NO OTHER DEFECTS. REMOVED AND REPLACED FO HEATING SENSOR GROUND TERMINAL. PERFORMED OPERATIONAL CHECK OF FOS WINDSHIELD HEATING SYSTEM. OPS CHECK SAT. NO FURTHER SIGNS OF SMOKE NOTED. INSTALLED GLARESHIELD COVER.
ROW 18A AND 18CD OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED ROW 18A AND 18CD OVERHEAD EMERGENCY LIGHT LAMPS. OPS CHECK SAT.
LAV SMOKE EICAS MESSAGE IN FLIGHT. CONFIRMED NO FLAME SMOKE OR SMELL PRESENT. PERFORMED LAV SMOKE DETECTOR ADJ TEST. OPS CHECK SAT. NO DEFECTS NOTED.
RF1, AFT RADIO ALTIMETER 2 EXTERNAL DOUBLER FOUND CORRODED. REPAIR DOUBLER ON REAR FUSE I LOWER SKIN, BTW FR 68-69 AND BTW STR 21L-21R
CF1, SERVICE DOOR ENTRANCE LOWER BEAM BTW FR 20-22 FOUND CORRODED. ON CF1, SERVICE DOOR ENTRANCE LOWER BEAM BTW FR 20-22 REMOVED FOR REPLACEMENT, BLENDED OUT OF LIMIT. ON CF1, SERVICE DOOR ENTRANCE LOWER BEAM BTW FR 20-22 INSTALLED AT SERVICE DOOR SEAL BOTTOM PART FWD AFT PARTIALLY REMOVED FOR ACCESS. SERVICE DOOR SEAL (AIR FRAME) REINSTALL
FF2, DENT FOUND ON SKIN UNDER EXTERNAL POWER RECEPTACLE ACCESS PANEL BTW FR 6-7 ON LH SIDE. FF2, ON SKIN UNDER EXTERNAL POWER RECEPTACLE ACCESS PANEL BTW FR 6-7 ON LH SIDE, DENT FOUND OUT OF LIMMIT. FF2, SKIN UNDER EXTERNAL POWER RECEPTACLE ACCESS PANEL BTW FR 6-7 ON LH SIDE REPAIRED.
NOSE LANDING GEAR W/W, PLATE 123-01754-001 CRACKED. NOSE LANDING GEAR W/W PLATE 123-01754-001 REMOVED AND REPLACED
CF4, CENTER OMEGA BEAM FOUND CORRODED BTW FR 60-61. REPAIR DOUBLER ON CENTER FUSE IV CENTER OMEGA BEAM ON UPPER SURFACE BTW FR 60-61
CF1, CENTER CROSS BEAM AT FR20 FOUND CORRODED. CROSS BEAM FABRICATED WITH AN ALTERNATE MATERIAL. CROSS BEAM REPLACED WITH FABRICATED PART
CF3, LH OMEGA BEAM OUTBD STUB ANGLE BTW FR 46-50 FOUND CORRODED. LH OMEGA BEAM OUTBD STUB ANGLE BTW FR46-50 BLENDED OUT OF LIMITS. LH OMEGA BEAM OUTBD STUB ANGLE REMOVED FOR REPLACEMENT. NEW OMEGA BEAM OUTBD STUB ANGLES INSTALLED AND REPLACED
CF4, CENTER GUSSET BTW FR 59-62 IN TOILET AREA FOUND CORRODED. CF4, CENTER GUSSET BTW FR 59-62 CORROSION BLENDED AND FOUND OUT OF LIMIT. CENTER GUSSET BTW FR 59-62 REPLACED WITH MADE REPAIR PART
TAIL COMPARTMENT, SHEAR CLIP CRACKED AT FRAME 80, BETWEEN STRINGER 5R AND 7R. REMOVED AND REPLACED SHEAR CLIP AT FR80 BTW STR 5R-7R
CF3, RH OMEGA BEAM OUTBD STUB ANGLE BTW FR46-50 FOUND CRACKED. REMOVED RH OMEGA BEAM OUTBD STUB ANGLE BTW FR46-50 FOR REPLACEMENT. RH OMEGA BEAM OUTBD STUB ANGLE BTW FR46-50 REPAIRED
RF1, SHEAR CLIP AT FR72 BTW STR 17L-18L FOUND CRACKED. RF1, SHEAR CLIP AT FR72 BTW STR 17L-18L REMOVED AND REPLACED
CF2, SHEAR CLIP AT FR28 AND BTW STR 15R-16R FOUND CRACKED. SHEAR CLIP FABRICATED. CF2 SHEAR CLIP FR28 BTW 15R-16R REPLACED WITH FABRICATED PART.
CORROSION FOUND ON LH CF4 OMEGA BEAM BTW FR 59-62. OMEGA BEAM AT CF4 BTW FR59-62 LH CORRODED BEYOND LIMIT. REWORKED DEPTH OF 30% EXCEEDED INTO TWO LOCATIONS, NOMINAL THICKNESS 0.050, 0.030 REMOVED. LH CF4 OMEGA BEAM BTW FR 59-62 REPAIRED WITH DOUBLER
CF3, CENTER OMEGA BEAM INBD STUB ANGLE BTW FR 46-50 FOUND CORRODED. CENTER OMEGA BEAM LH STUB ANGLE BTW FR 46-50 BLENDED OUT OF LIMITS. REMOVED AND REPLACED CENTER OMEGA BEAM LH STU ANGLE BTW FR 46-50
CF3, LH OMEGA BEAM INBD STUB ANGLE BTW FR 46-50 FOUND CORRODED. AFTER INVESTIGATION LH OMEGA BEAM INBD STUB ANGLE BTW FR 46-50 FOUND CRACKED. LH OMEGA BEAM INBD STUB ANGLE REMOVED FOR REPLACEMENT. NEW OMEGA INBD STUB ANGLES INSTALLED
CF1, LH OMEGA BEAM INBD FLANGE, CRACK SUSPECTED AT FR21-22. 2 REPAIR DOUBLERS ON LH CENTER FUSE I OMEGA BEAM, ON INBD FLANGE AT FR 21 & 22.
CF4, RH SILL BTW FR53-59 FOUND CORRODED. ON CF4, RH SILL BTW FR 53-59 BLENDED OUT OF LIMIT. CF4, RH SILL BTW FR 53-59 REMOVED AND REPLACED
INBD L-SHAPE BRACKET FOUND HEAVY CORROSION ON LH INBD FLAP. INBD L-SHAPE BRACKET ON LH INBD FLAP BLENDED OUT OF LIMIT. LH INBD FLAP INBD L-SHAPE BRACKET REPLACED
CF2, SHEAR CLIP AT FR26 BTW STR 16R-17R FOUND CRACKED. CF2, SHEAR CLIP AT FR26 BTW STR 16R-17R REMOVED AND REPLACED
CF1, OCTOGONAL DOUBLER AT FR22 ON RH OMEGA BEAM CORRODED. ON CF1, ON RH OMEGA BEAM AT FR22 OCTOGONAL DOUBLER FOUND CORRODED OUT OF LIMITS. ON CF1, ON RH OMEGA BEAM AT FR22, OCTOGONAL DOUBLER REMOVED FOR REPLACEMENT AND NEW DOUBLER FULLY DRILLED ON CF1, ON RH OMEGA BEAM AT FR22, NEW DOUBLER FULLY INSTALLED.
OCTOGONAL DOUBLER AT FR20 ON RH OMEGA BEAM FOUND CORRODED. ON CF1, ON RH OMEGA BEAM AT FR20, OCTOGONAL DOUBLER FOUND CORRODED OUT OF LIMITS. ON CF1, ON RH OMEGA BEAM AT FR20, OCTOGONAL DOUBLER REMOVED FOR REPLACEMENT AND NEW DOUBLER FULLY DRILLED. ON CF1 ON RH OMEGA BEAM AT FR20 NEW OCTOGONAL DOUBLER FULLY INSTALLED.
CF2, SHEAR CLIP AT FR27 AND BTW STR 15R-16R FOUND CRACKED. CF2, SHEAR CLIP AT FR27 BTW STR 15R-16R REMOVED AND REPLACED
MLG TRAILING ARM, AXLE PIN HAS ROTATED AND DAMAGES TAILING EDGE ASSEMBLY. MLG MAIN WHEEL AND BRAKE ASSEMBLY REMOVED FOR ACCESS. MLG TRAILING ARM REPLACED. MLG MAIN WHEEL AND BRAKE ASSEMBLY INSTALLED. MLG AUX DOOR INSTALLED. MLG CARDON JOINT AND AXLE PIN REMOVED AND REINSTALLED.
UPON REMOVAL OF STANDBY PITOT PROBE, WE FOUND EVIDENCE OF OVERHEATING ON WIRING AND CONNECTOR P0089. THE WIRE W102-0270-16 REMOVED FROM P0089 AND RELAY K0058 AND REPLACED.
CF1, ANGLE ON LH OMEGA BEAM BTW FR 19-20 FOUND CRACKED. AT CF1, ANGLE ON LH OMEGA BEAM BTW FR 19-20 ANGLE REPLACED
FWD BELLY FAIRING, RH EMERGENCY LIGHT 191JL, DOUBLER FOUND CORRODED. FWD BELLY FAIRING, RH EMERGENCY LIGHT 191JL DOUBLER REMOVED FOR ACCESS. DOUBLER FOUND CORRODED OUT OF LIMITS. ON FWD BELLY FAIRING, RH EMERGENCY LIGHT 191JL DOUBLER REPLACED.
CF2, SHEAR CLIP AT FR25 AND BTW STR 15R-16R FOUND CRACKED. CF2, SHEAR CLIP FR25 BTW STR 15R-16R REMOVED AND REPLACED
RF1, SHEAR CLIP AT FR62 AND BTW STR 6R-8R FOUND CRACKED. RF1, AT FR62 AND BTW STR 6R-8R SHEAR CLIP REPLACED. RF1 AT FR62 BTW STR 6R-8R GROUND ON SHEAR CLIP REMOVED AND REINSTALLED.
CF2, SHEAR CLIP AT FR24 AND BTW STR 15R-16R FOUND CRACKED. CF2, SHEAR CLIP FR24 BTW STR 15R-16R REMOVED AND REPLACED
CF2, SHEAR CLIP AT FR24 AND BTW STR 14R-15R FOUND CRACKED. CF2, SHEAR CLIP AT FR24, BTW STR 14R-15R REMOVED AND REPLACED
ON RH ENG PYLON BLEED AIR PRECCOLER REMOVED, FWD STRUCTURAL BRACKET FOUND CRACKED AND BENT. ON RH ENG PYLON BLEED AIR PRECOOLER FWD STRUCTURE BRACKET REMOVED AND REPLACED
CF3, RH WING STUB FITTING AT FR46 AT FLOOR LEVEL FOUND CRACKED. RH WING STUB ANGLE (FITTING) AT FR 46 AT FLOOR LEVEL REMOVED AND NEW ANGLE DRILLED. RH WING STUB FITTING ANGLE REPLACED.
CF4, RH OMEGA BEAM FOUND CORRODED BTW FR60-61. REPAIR DOUBLER ON CENTER FUSE IV RH OMEGA BEAM ON UPPER SURFACE BTW FR60-61
RF1, SHEAR CLIP AT FR73 AND BTW STR 8R-10R FOUND CRACKED. SHEAR CLIP AT FR73 BTW STR 8R-10R REPLACED
CF2, LH SILL BTW FR 29-36 FOUND CORRODED. CF2, LH SILL BTW FR 24-36 BLENDED CORROSION AND FOUND OUT OF LIMIT. CF2, LH SILL BTW FR 29-36 REMOVED AND REPLACED.
CF2, RH SILL BTW FR 29-36 FOUND CORRODED. RH SILL BTW FR 29-36 BLENDED OUT OF LIMITS. CF2 RH SILL BTW FR 29-36 REMOVED AND REPLACED
CF4, LH GUSSET BTW FR59-62 IN TOILET AREA FOUND CORRODED. CF4, LH GUSSET BTW FR 59-62 IN TOILET BLENDED AND FOUND OUT OF LIMITS. LH GUSSET BTW FR 59-62 REMOVED AND REPLACED WITH MORE REPAIR PART AND MASTER PART AND INSTALLED
CF2, LH SILL BTW FR 24-29 FOUND CORRODED. LH SILL BTW FR 24-29 BLENDED OUT OF LIMITS. ON CF2, LH SILL BTW FR24-29 REMOVED AND REPLACED
RF1 SHEAR CLIP AT FR66 AND BTW STR 6L-7L FOUND CRACKED. AT RF1, SHEAR CLIP AT FR66 AND BTW STR 6L-7L REMOVED AND REPLACED
CF2, RH SILL BTW FR 24-29 FOUND CORRODED. RH SILL BTW FR 24-29 BLENDED OUT OF LIMITS. CF2, RH SILL BTW FR 24-29 REMOVED AND REPLACED
CF4, RH GUSSET BTW FR59-62 IN TOILET AREA FOUND CORRODED. GUSSET AT CF4 TOILET AREA CORRODED BEYOND LIMIT. OLD GUSSET REMOVED AND NEW GUSSET AT CF4. RH BTW FR 59-62 INSTALLED. NOMINAL THICKNESS 0.040, 0.025 REMOVED REWORK DEPTH OF 30% EXCEEDED.
EMERGENCY EXIT ROW CEILING LIGHTS BOTH INOPERATIVE. REMOVED AND REPLACED RH AND LH OVERWING EMERGENCY LIGHT LAMPS. OPS CHECK SAT.
MCD EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BULB. OPS CHECK GOOD.
WING EMERGENCY EXIT LIGHT INOPERATIVE. OPS CHECKED EMERGENCY EXIT LIGHT GOOD
CABIN AND CABIN EMERGENCY LIGHTS REMAIN ILLUMINATED DISABLING PA USE FD AND FA. INSPECTED AND FOUND CABIN AND CABIN EMERGENCY ILLUMINATED ON ICU. REMOVED AND REPLACED PA AMPLIFIER. OPS CHECK SAT
LH EXTERNAL OVERWING EMERGENCY LIGHT AND BOTH PSU EMERGENCY LIGHTS AT ROW 18 INOPERATIVE. SUSPECT BPS #3 TO BE BAD. REMOVED AND REPLACED BPS #3. OPS CHECK GOOD
SMOKE IN COCKPIT ON TAKE OFF DURING CLIMB OUT. FOUND DEICING FLUID IN ENGINE INLETS. CLEANED FLUID AND PERFORMED HIGH POWER RUNS WITH CREW. NO SMOKE OR ABNORMAL SMELL NOTED.
SERVICE DOOR EMERGENCY LIGHT INOPERATIVE. SERVICE DOOR EMERGENCY LIGHT CONTACT SOLDER DEFORMED, ADDED SOLDER. OPS CHECK GOOD
GROUND CREW NOTICED MCD HANDLE STICKING OUT WHEN DOOR CLOSED AND MFD INDICATIONS OPEN. CLEANED AND LUBRICATED MAIN DOOR ROLLERS. OPEN AND CLOSED DOOR, OPS CHECK SAT. NO INDICATION. NO STICKING HANDLE
SUPPLEMENTAL (NEW) INFORMATION: FOUND EVIDENCE OF FIRE FROM #2 GEN. PERFORMED FIRE INSPECTION. FOUND LOWER COWLING TO HAVE MAJORITY OF THE HEAT DAMAGE CAUSED BY THE #2 GEN. COWLING WILL REQUIRE REPLACEMENT. FOUND THAT ALL SUSPECTED DAMAGE TO INTERNAL COWLING/PYLON AND ENG COMPONENTS TO BE HEAVY SOOT AFTER CLEANING. ALL AFFECTED AREAS NO SIGNS OF HEAT DAMAGE ON ALL COMPONENTS OTHER THAN ON #2 GEN EXHAUST ASSEMBLY.
EMERGENCY LIGHT OVER WING ROW 18 INSIDE INOP. REMOVED AND REPLACED #3 EMERGENCY LIGHT BATTERY OPS CHECK SAT.
LH OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BULB. OPS CHECK SAT.
EXIT ROW FWD CEILING EMERGENCY EXIT INDICATION PLACARD DISBONDED FROM LH MOUNTING SCREW. REMOVED AND REPLACED EXIT LOCATING SIGN ASSEMBLY. OPS CHECK SAT.
SERVICE DOOR EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED SERVICE DOOR EXTERNAL EMERGENCY LIGHT. OPS CHECK SAT
RH ELEVATOR UPPER SKIN NEAR I/B SPRING TAB O/B MOUNT HAS TEAR. REPAIRED RH ELEVATOR UPPER SKIN NEAR I/B SPRING TAB O/B MOUNT.
RIGHT HORIZONTAL STAB HINGE INBD LUG BUSHING MIGRATED. REPAIRED IAW SRM 55-10-02.
RIGHT HORIZONTAL STAB HINGE OTBD LUG BUSHING MIGRATED. REPAIRED IAW SRM 55-10-02.
LEFT HORIZONTAL STAB HINGE OTBD LUG BUSHING MIGRATED. REPAIRED IAW SRM 55-10-02.
LEFT HORIZONTAL STAB HINGE, INBD LUG BUSHING MIGRATED. REPAIRED IAW SRM 55-10-02.
LEFT INBD HORIZONTAL HINGE MOUNT LUG HAD DISPLACED METAL. REPAIRED IAW SRM 55-10-02.
RIGHT OTBD HORIZONTAL HINGE MOUNT LUG HAS DISPLACED METAL. REPAIRED IAW SRM 55-10-02.
TYS A/C WAS IN A A-CHECK CONDITION WHEN INSPECTION FOUND THE LAV RETURN TO SEAT LIGHT PC BOARD BURNT. MAINTENANCE REMOVED AND REPLACED THE PC BOARD ASSEMBLY IAW AMM 33-23-05. OPS CHECK WAS GOOD AND WAS RELEASED.
TYS A/C WAS IN A A-CHECK STATUS WHEN INSPECTION FOUND THE NR 2 RUDDER WITH 3 DISTINCT DENTS ON THE TRAILING EDGE. MAINTENANCE REMOVED AND REPLACED RUDDER 2 IAW WITH TASK CARD 538087, IPC 27-21-02 FIG 02B ITEM 1. OPS CHECK GOOD AND WAS RELEASED.
DURING ROUTINE MAINTENANCE, THE EMERGENCY EXIT SIGN BY THE SERVICE DOOR WAS FOUND INOPERATIVE. MAINTENANCE REPLACED THE INVERTER. OPS CHECKED GOOD.
PILOT REPORTED THE LOWER EMERGENCY EXIT LIGHT ON THE GALLEY DOOR IS OUT. MX REMOVED AND REPLACED THE LAMP. OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.
THE CREW REPORTED AFTER ENTERING ICING CONDITIONS AND ICE PROTECTION ACTIVATED, A LOUD THUD NOISE WAS HEARD FOLLOWED BY THE STRONG ODOR OF SMOKE IN THE COCKPIT AND WHITE CLOUD OF SMOKE BY THE LAST 5 ROWS IN BACK OF ACFT. MAINTENANCE INSPECTED AND REPLACED THE NR 11 MID COUPLING O-RINGS ON THE BLEED AIR SYSYTEM. PERFORMED OPS CHECKS OF BOTH PACKS. NO DEFECTS WERE NOTED.
DURING C-CK. CENTER OMEGA BEAM CORRODED AT FRAME 59. REPAIRED OMEGA BEAM IAW EC5310-01473. ACFT WAS APPROVED FOR RETURN TO SERVICE.
DURING C-CHECK. CARGO DOOR LOWER BEAM CORRODED BETWEEN FRAME 65-68. R & R CARGO DOOR LOWER BEAM IAW SRM 51-40-02. ACFT WAS APPROVED FOR RETURN TO SERVICE.
PILOT REPORTED THE MAIN CABIN DOOR HANDLE HARD TO OPEN. MAINTENANCE ADJUSTED MCD CABLE TENSION AND ADJUSTED INTERCONNECT RODS, OPS CHECKED GOOD. ACFT WAS APPROVED TO RETURN TO SERVICE.
DURING PREFLIGHT INSPECTION, THE CREW REPORTED THE EMERGENCY EXIT LIGHT AT SERVICE DOOR AND BULKHEAD AT 3CD WERE FOUND TO BE INOPERATIVE. INSPECTED AND RESEATED THE BATTERY IN THE POWER SUPPLY, OPS TESTED WITH NO DEFECTS, AND THE AIRCRATF WAS APPROVED FOR RETURN TO SERVICE.
DURING FINAL APPROACH, CREW REPORTED A BURNING ELECTRICAL ODOR AT ROW 7. ACFT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND FOUND A BLOWN AND CRACKED DUCT DIRECTLY BELOW ROW 7.
DURING FINAL APPROACH, THE CREW REPORTED A BURNING ELECTRICAL ODOR AT ROW 7. THE ACFT LANDED WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE ACFT AND FOUND A BLOWN AND CRACKED DUCT DIRECTLY BELOW ROW 7.
AFTER TAKEOFF, CREW REPORTED SMOKE IN LAVATORY AND ELECTED TO RETURN TO DEPARTURE. LANDED WITHOUT INCIDENT. MAINTENANCE DETERMINED SOURCE OF SMOKE TO BE COMING THROUGH THE NR 2 ENGINE BLEED. ENGINE WAS REPLACED, OPS CHECK PERFORMED AND THE DISCREPANCY CLEARED.
RIGHT OMEGA BEAM CORRODED BEYOND LIMITS. R & R CORRODED SECTION OF BEAM IAW EC5310-01711
THE CREW REPORTED THE EMERGENCY EXIT LIGHT IN CENTER OF AISLE BURNED OUT. MX INSPECTED AND RESET THE AISLE PATH LIGHTING SYS. OPERATIONAL CHECKS WERE GOOD. NO DEFECTS FOUND.
MCI - FLIGHT 6096, DURING LEVEL FLIGHT AT APPROXIMATELY 4000FT THE CREW REPORTED MULTIPLE GPWS WARNINGS INCLUDING "LANDING GEAR", "BANK ANGLE", AND "TOO LOW GEAR". THE AIRCRAFT LANDED AT MCI WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE AIRCRAFT AND PLACED THE EGPWS ON MEL 34-41-00-1, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. THE AIRCRAFT SUBSEQUENTLY LANDED AT DEN WHERE MAINTENANCE REMOVED AND REPLACED THE EGPWS UNIT, OPERATIONALLY TESTED WITH NO DEFECTS, REMOVED THE MEL, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.
SHV - DURING C-CHECK THE SHEAR CLIP AT FRAME 65 FOR THE CARGO DOOR CUTOUT FORWARD LOWER CORNER WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A SPLICE REPAIR IAW EXPRESSJET EC5320-01494. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.
FLIGHT 2056 - EWR - FLIGHT CREW REPORTED LAV SMOKE INDICATION ON EICAS (NO SMOKE NOTICED DURING VISUAL INSPECTION). EWR MX RAN ENGINES AND PACKS - NO SMOKE NOTICED AND PERFORMED OPERATIONAL CHECK FOR THE LAV SMOKE DETECTION SYSTEM SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.
ORD FLT 2301 - THE CREW REPORTED THE BRAKES PULSATE ON LANDING CAUSING THE AIRCRAFT TO SHAKE VIOLENTLY, AIRCRAFT DIFFICULT TO CONTROL. MAINTENANCE INSPECTED ALL BRAKE ASSEMBLIES AND WHEEL SPEED X-DUCERS AND HARNESS AND REPLACED THE NR 3 BRAKE ASSEMBLY. PERFORMED OPERATIONAL CHECKS AND PERFORMED HIGH SPEED TAXI.
IAH - FLIGHT 2045, THE CREW REPORTED A LAV SMOKE DETECTOR WENT OFF IN FLIGHT. THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED THE AIRCRAFT AND REMOVED AND REPLACED THE LAVATORY SMOKE DETECTOR, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.
FLIGHT 2914 - EWR - FLIGHT CREW REPORTED LAV SMOKE INDICATION DURING CLIMBING, MESSAGE CLEARED ABOUT 1 MIN LATER. EWR MX PERFORMED OPERATIONAL CHECK ON LAV SMOKE DETECTOR SYSTEM AND COULD NOT DUPLICATE MESSAGE. ACFT WAS APPROVED TO RETURN TO SERVICE.
FLIGHT 2485 - ORF - FLIGHT CREW REPORTED LOUD SQUALL COMING FROM BOTH COMMS/HEADSETS AND THEY WERE UNABLE TO COMMUNICATE TO EACH OTHER. CREW PERFORMED AIR RETURN AND LANDED ACFT UNEVENTFULLY. MX FOUND LOOSE SCREW ON NR 1 VHF ANTENNA. MX TIGHTEN SCREWS AND FLIGHT CREW PERFORMED COMM OPERATIONAL CHECK AND ALSO A FLIGHT TEST SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.
IAH - FLIGHT 2020, DURING PREFLIGHT INSPECTION THE CREW REPORTED AN EXIT LIGHT IN THE CABIN AS INOPERATIVE. MAINTENANCE CLEANED THE CONNECTOR ON THE AFFECTED EXIT LIGHT, OPERATIONALLY TESTED WITH NO DEFECTS. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.
IAH - DURING PREFLIGHT INSPECTION THE CREW REPORTED THAT THE EMERGENCY EXIT LIGHTS / SIGNS AT ROW 12 WERE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED EMERGENCY LIGHT INVERTER, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.
IAH - DURING PREFLIGHT INSPECTION THE CREW REPORTED THAT THE EMERGENCY EXIT LIGHT AT THE MAIN CABIN DOOR WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED EMERGENCY LIGHT INVERTER, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.
FLIGHT 3146 - EWR - DURING CLIMBING PAST FL 240, FLIGHT CREW REPORTED NOISE AND VIBRATION APPEARING TO COME FROM THE WINDSHIELD SEAM INSULATION. CREW PERFORMED AIR RETURN AND LANDED ACFT SAFELY. EWR MX FOUND CAPTAIN WINDSHIELD HUMP SEALANT PEELING OFF. MX TRIMMED THE LOOSE SEALANT AND PERFORMED SEALANT REPAIR.
IAH - DURING PREFLIGHT INSPECTION THE CREW REPORTED AN EMERGENCY EXIT SIGN AT ROW 12 TO BE INOPERATIVE. MAINTENANCE INSPECTED THE EXIT SIGN, RESECURED THE CONNECTORS, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.
IAH - FLIGHT 2060 - THE CREW REPORTED THAT THE AIRCRAFT WOULD NOT PRESSURIZE IN FLIGHT. THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE DIGITAL CONTROLLER, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.
FLT 0017 - TUS TO SAT - DURING CRUISE FLIGHT CREW REPORTED HYD SYS 1 INDICATED 0 PRESSURE AND 0 QUANTITY. CONTRACT AND ONT MX PERSONNEL WERE DISPATCHED. AIRCRAFT DIVERTED TO TUS AND DECLARED NO EMERGENCY AND LANDED SAFELY. MX PERSONNEL AFTER VISUAL INSPECTION FOUND HYD SERVICE LINE DISCONNECTED. MX RE-TIGHTENED SERVICE LINE OPERATIONALLY CHECK SATISFACTORY AND AIRCRAFT WAS RELEASED TO RETURN TO SERVICE.
SHV - DURING C-CHECK LT OMEGA BEAM HAS CORROSION ON FR 20. MX REPAIRED LT OMEGA BEAM AT FR 20 IAW EMB 145 SRM 53-20-10. THE AIRCRAFT WAS APPROVED TO RETURN FOR SERVICE.
FLT 419 - LAS TO COS - DURING CRUISE FLIGHT CREW REPORTED AND DECLARED EMERGENCY AND DIVERTED THE FLIGHT BACK TO LAS WHERE IT LANDED SATISFACTORY WITHOUT INCIDENT DUE TO NR 1 FUEL QTY IND 0, FUEL INBALANCE, FUEL 1 LOW LEVEL EICAS MSGS. MX CONTROL AUTHORIZED FLIGHT CREW TO RELEASE THE AIRCRAFT IAW MEL 28-40-00/2. 10-12-07 ON 09/06/2007 THE AIRCRAFT WAS FLOWN TO ONT FOR FURTHER INSPECTION. MX PERSONNEL PERFORMED NR 1 FUEL LOW LEVEL OPERATIONAL CHECKS AND SATISFACTORY CHECK GOOD AND AIRCRAFT WAS RELEASE TO RETURN FOR SERVICE IN AIRWORTHY CONDITIONS.
CREW REPORTED "SMOKE ODOR SMELLED IN COCKPIT IN FLIGHT, ONLY FOR FIVE MINUTES, GONE AFTER A FEW MINUTES. MAINTENANCE ACCOMPLISHED VISUAL INSPECTION OF COCKPIT AREA AND RELAY PANEL. NO DEFECTS NOTED IAW EMB145MM NR 5-20-14. AIRCRAFT RETURNED TO SERVICE.