N284JN

EMBRAER S A ERJ 170-200 LR · 2019 · Fixed-wing multi-engine · 2 engines · 88 seats · Valid Registration

Registered owner: AMERICAN AIRLINES INC, TX (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

12 reports on file, 2020-02-24 – 2026-10-26.

SMOKE/FUMES/ODORS/SPARKS · 2026-10-26 Matched by certificate designator
ATA 3410

Part: PROBE — ODOR (NR 3) · airframe 18,718 hrs · 12,595 cycles

BURNING ODOR DURING DESCENT AND DURING WALK AROUND, BURNING ODOR DETECTED CLOSE THE LEFT RVSM AREA PERFORMED EMB TRIAD WORK SCOPE AS INSTRUCTED. PERFORMED OPC OF AIR-CONDITIONING DISTRIBUTION SYSTEM FOR SMOKE AND ODORS IAW FIM 21-20-00-810-801-A - NO DEFECTS OR ODORS DETECTED. INSPECTED FWD EBAY AREA AND RECIRCULATION FANS FOR OPERATION WITH PACKS RUNNING IAW FIM 21-20-00-810-801-A - NO DEFECTS NOTED - RECIRCULATION FANS OPERATING NORMALLY WITH NO ODORS. PERFORMED OPC AND DET INSPECTION OF ADS PROBES IAW AMM 34-15-00 AND AMM 34-13-01 STEP 9 - FOREIGN MATERIAL FOUND ON LH UPPER ADS PROBE # 3 DURING OPC OF ADS PROBE # 3 A BURING ODOR WAS DETECTED. CLEANED AND REMOVED FOREIGN MATERIAL FROM ADS PROBE # 3 AND PERFOMRED OPC CHK - NO ODORS OR DEFECTS NOTED AFTER FOREIGN MATERIAL REMOVED FROM PROBE. PERFORMED DET INSPECTION OF PACK # 2 INLET FOR EVIDENCE OF INGESTION OF COFFEE OR SODA COMING FROM FWD GALLEY DRAIN MAST - NO EVIDENCE OF FOREIGN MATERIAL INGESTION DETECTED. PERFORMED ENGINE RUN OF BOTH ENGINES AT MAX POWER WITH APU RUNNING FOR 4 MINUTES IAW FIM TASK 21-20-00-810-803-A - NO EICAS MESSAGES, DEFECTS OR ODORS DETECTED DURING OR AFTER ENGINE RUNS.

Source: SDR SIMA20261026001
SMOKE/FUMES/ODORS/SPARKS · 2026-09-15 Matched by certificate designator
ATA 2150

Part: A/C PACK — CONTAMINATED (ZONE 100) · airframe 18,426 hrs · 12,370 cycles

BURNING RUBBER, WET RAG ODOR COMING FROM VENTS THROUGHOUT ENTIRE AIRCRAFT. SCENT BEGAN DURING STARTUP, DISSIPATED DURING CRUISE, BEGAN AGAIN DURING DESCENT. C/W WORKS COPE AS REQUIRED. ITEM 3 C/W FIM TASK 21-20-00-810-A, NO FAULTS FOUND. ITEM 4 IDENTIFIED COFFEE AND SODA INGESTED AND COKED INTO PACK 2 INLET, COVERING THE PRECOOLER AND POSSIBLE INTERNAL ACM CONTAMINATION. ITEM 5 C/W FIM TASK 21-20 -00-810-803-A. WHEN PERFORMING CHECKS WITH APU BLEED, THERE WAS A SLIGHT BURN SMELL FOR 30 SECONDS AND CLEARED. WHEN PREFORMING THE OPERATION OF PACK 1 WITH ENG 1 NO FAULTS OR SMELLS NOTED . WHEN PERFORMING THE OPERATIONAL CHECKS WITH NUMBER 2 ENG AND NUMBER 2 PACK, A SMELL OF CHOCOLATE WAS NOTED. AIRCRAFT IS TRIAD RELEASED WITH NUMBER TWO PACK MEL'D. SEE AML 115302370 FOR DEFERRAL OF PACK 2.

Source: SDR SIMA20260915001
OTHER · 2026-07-14 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (ZONE 200) · airframe 17,935 hrs · 12,001 cycles

EMERGENCY PHOTOLUMINESCENT ESCAPE ROUTE MARKING SYS - M1 FRONT RIGHT CABIN PHOTOLUMINESCENT STRIP FADED DOES NOT ILLUMINATE. MEL 3332 - AUTH# 07-527-C REPAIR C - POSITION FWD CAB - FMR 084330267 - MEL DEFERRAL - CATEGORY C. RAR FRONT RIGHT CABIN EMERGENCY PHOTOLUMINESCENT STRIP IAW AMM 33-50-51 MEL RESTORED.

Source: SDR SIMA20260714003
OTHER · 2026-07-09 Matched by certificate designator
ATA 3350

Part: GLOWSTRIP — FADED (ZONE 200) · airframe 17,886 hrs · 11,967 cycles

FRONT RIGHT CABIN EMERGENCY PHOTOLUMINESCENT STRIP FADED DOES NOT ILLUMINATE. RAR FRONT RIGHT CABIN PHOTOLUMINESCENT STRIP IAW AMM 33-50-51 MEL RESTORED.

Source: SDR SIMA20260709002
OTHER · 2026-07-09 Matched by certificate designator
ATA 3350

Part: LIGHT — FADED (ZONE 200) · airframe 17,886 hrs · 11,967 cycles

FRONT RIGHT CABIN EMERGENCY PHOTOLUMINESCENT STRIP FADED DOES NOT ILLUMINATE. DEFERRED PER MEL 33-32 AUTH 070527-C. PENDING CORRECTIVE ACTION

Source: SDR SIMA202607109002
OTHER · 2025-11-22 Matched by certificate designator
ATA 5344

Part: HINGE — OUT OF ADJUST (ZONE 200) · airframe 16,086 hrs · 10,758 cycles

DOOR 1L HEAVY AND DIFFICULT TO MANIPULATE. INSPECTED, LUBRICATED AND ADJUSTED DOOR 1L HINGE ASSY, ACTUATING AND LOCKING MECHANISM IAW ERJ AMM 52-11-00 AND 52-11-20. OPC GD ACFT OK FOR SERVICE

Source: SDR SIMA202511242001
SMOKE/FUMES/ODORS/SPARKS · 2025-09-12 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (COCKPIT) · airframe 15,533 hrs · 10,372 cycles

STRONG SMELL OF SMOKE IN THE COCKPIT FOLLOWED FIM TASK 21-20-00-810-801-A. NO SMOKE SMELL NOTED DURING INSPECTION. TRIAD RELEASED....MOC 341558

Source: SDR SIMA20250912001
NO TEST · 2025-06-03 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (ZONE 200) · airframe 14,980 hrs · 9,978 cycles

FOUND PHOTO ILLUMINESCENT STRIP IN FRONT OF FWD WARDROBE NOT ILLUMINATING RAR PHOTOLUMINESCENT INDICATOR STRIP FWD OF WARDROBE IAW AMM 33-50-21. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED.

Source: SDR SIMA20250603001
OTHER · 2024-09-02 Matched by certificate designator
ATA 3350

Part: BATTERY — INOPERATIVE (ZONE 200) · airframe 12,869 hrs · 8,498 cycles

CEILING EMERGENCY LIGHT #5 INOP. REF LGPG 5180368 ITEM 1 RAR #3 EMERGENCY LIGHT POWER UNIT IN REF WITH ERJ 175 AMM 33-50-01. PERFORMED OPERATIONAL TEST IN REF WITH ERJ 175 AMM 33-50-01. OPS CHECK GOOD.

Source: SDR SIMA20240902001
OTHER · 2024-08-27 Matched by certificate designator
ATA 5210

Part: LATCH — LACK OF LUBE (ZONE 800) · airframe 12,822 hrs · 8,459 cycles

L1 PASSENGER DOOR HARD TO OPEN/CLOSE LUBRICATED L1 DOOR OUTER LATCH MECHANISM AND OPENED AND CLOSED DOOR IAW ERJ-GHC-08-23 R1. TESTED SATISFACTORY

Source: SDR SIMA20240827001
WARNING INDICATION · 2023-11-14 Matched by certificate designator
ATA 2752

Part: ACTUATOR — FAILED (RT WING TE FLAPS) · airframe 10,550 hrs · 6,833 cycles

FLAP FAIL AT AFTER LANDING RETRACTION AT FLAPS 1-C/A-REMOVED AND REPLACED R/H OUTBOARD FLAP PANEL ACTUATOR (4R). REF. E175 AMM 27-51-01. OPS CHECKS GOOD. NO DEFECTS NOTED.

Source: SDR SIMA202311164001
OTHER · 2020-02-24 Matched by certificate designator
ATA 2421

Part: GCU — INOPERATIVE (NR 2) · airframe 1,070 hrs · 648 cycles

IDG 2 OIL RAN QRH-C/A-DEFERRED #2 IDG PER MEL 24-5. FOUND IDG 2 DISCONNECTED PER DEFERRAL RECONECCTED IDG 2 IAW AMM 24-21-01. TROUBLESHOT PER FIM TASK 24-21-00-810-812-A. FOUND GCU2 TO BE INOP RAR IAW AMM 24-21-19 OPC GOOD. MEL RESTORED. PERFORMED OPC CHK OF IDG 2 IAW AMM 24-21-01. OPC GOOD.

Source: SDR SIMA202002254001