N286GB

BOEING 757-256 · 1994 · Fixed-wing multi-engine · 2 engines · 295 seats · Valid Registration

Registered owner: TVPX AIRCRAFT SOLUTIONS INC TRUSTEE, UT (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

PIPER PA-23 No injuries Part 91 — operator not named in the NTSB record
Source: NTSB case NYC66F0238

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

5 reports on file, 2022-08-20 – 2026-10-12.

OTHER · 2026-10-12 Matched by certificate designator
ATA 5610

Part: WINDOW — FAILED (R1) · airframe 69,294 hrs · 24,335 cycles

ETOPS SIGNIFICANT EVENT, RT FWD WINDOW SHATTERED AT FL380. NOTICED A SMALL BUT EXPANDING CRACK. PERFORMED WINDOW DAMAGE QRH. WINDOW FULLY SHATTERED SHORTLY AFTER, R1 WINDOW WAS REPLACED IAW AIRCRAFT MAINTENANCE MANUAL.

Source: SDR I5PA2026101228604
NO TEST · 2026-10-06 Matched by certificate designator
ATA 3610

Part: SHUTOFF VALVE — FAULTED (LT ENGINE) · airframe 69,253 hrs · 24,321 cycles

ETOPS SIGNIFICANT REPORT LEFT ENGINE BLEED OFF ON CLIMB - R & R LEFT ENGINE HPSOV PER AMM

Source: SDR I5PA2026100628603
NO TEST · 2026-10-05 Matched by certificate designator
ATA 2310

Part: TRANSCEIVER — FAULTY (E4-3 RACK) · airframe 69,238 hrs · 24,318 cycles

ETOPS SIGNIFICANT REPORT HF SYSTEM INOPERATIVE. REPLACED HF TRANSCEIVER PER AMM.

Source: SDR I5PA2026100528601
NO TEST · 2026-10-05 Matched by certificate designator
ATA 2310

Part: COUPLER — FAULTY (ZONE 300) · airframe 69,238 hrs · 24,318 cycles

ETOPS SIGNIFICANT REPORT, HF SYSTEM INOPERATIVE. REPLACED HF COUPLER IAW AMM.

Source: SDR I5PA2026100528602
ENGINE FLAMEOUT · 2022-08-20 Unresolved
ATA 7200

Part: ENGINE — OVERTEMP (ZONE 500) · airframe 68,387 hrs · 23,957 cycles

DURING SHORT FINAL LEFT ENGINE FLAMED OUT. EGT TEMPERATURE EXCEDANCE AFTER FUEL CUT-OFF.

Source: SDR 2022F00342