N306FL
Registered owner: RAINS RONALD D, TX (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
25 reports on file, 1997-09-13 – 2011-06-06.
Part: INLET — CRACKED (RT ENGINE) · airframe 200 hrs · 147 cycles
DURING INSP OF RT ENGINE INLET, CRACKS, SCRATCHES, AND MISSING RIVETS WERE FOUND ON BOTH ENGINE INLETS. THE AIRCRAFT MANUFACTURER HAS DETERMINED THAT THE DAMAGE IS ACCEPTABLE AND HAS ALLOWED THE INLET TO CONTINUE IN SERVICE WITH ADDITIONAL PERIODIC INSPECTION REQUIREMENTS. THE INLET WILL BE REPLACED AT A LATER DATE.
Earlier reports · 1997–2005 · 24 reports
2005
Part: ROLLER — WORN (GUIDE ARM) · airframe 24,272 hrs · 11,795 cycles
MAINTENANCE REPORTED R1 DOOR HARD TO CLOSE. REPLACED GUIDE ARM ROLLER PER MM 52-61-20. ADJUSTED R1 DOOR PER MM 52-41-00. REMOVED AND REINSTALLED R1 DOOR SLIDE PER MM 25-61-35. REMOVED AND REINSTALLED R1 DOOR LINER PER MM 52-41-31. REMOVED AND REINSTALLED R1 DOOR PER MM 52-41-00.
2003
Part: SKIN — DENTED (FUSELAGE) · airframe 21,103 hrs · 9,980 cycles
DURING C-7 CHECK, INSPECTION REPORTED CREASED DENT IN EXTERNAL FUSELAGE SKIN AT STA 368, 4 IN BELOW STR 18R. REPAIRED PER SRM 53-00-01 FIG 202.
Part: ACTUATOR — INOPERATIVE (NR 3 SLAT) · airframe 21,103 hrs · 9,980 cycles
DURING C-7 CHECK, INSPECTION REPORTED NR 3 SLAT ACTUATOR FAILED LOCK PIN TEST. REPLACED NR 3 SLAT ACTUATOR IAW MM 27-81-41 AND ACCOMPLISHED LE SLAT ACTUATOR LOCK PIN TEST AND LE SLAT ALTERNATE SYSTEM TESTS IAW TASK CARD 5-2710 AND MM 27-81-00.
Part: INTERCOSTAL — CRACKED (FUSELAGE) · airframe 21,103 hrs · 9,980 cycles
DURING C-7 CHECK, INSPECTION REPORTED MAIN DECK FLOOR INTERCOSTAL CRACKED BETWEEN STA 294 AND STA 312 AT RBL 32. REPLACED DAMAGED UPPER CHORD OF FLOOR INTERCOSTAL PER SRM 51-40-2.
Part: OXYGEN BOTTLE — DISCHARGED (CABIN) · airframe 21,103 hrs · 9,980 cycles
DURING C-7 CHECK, INSPECTION REPORTED SEAT 7 ABC OXYGEN CANISTER DISCHARGED. REPLACED OXYGEN GENERATOR CANISTER PER MM 35-22-11, PAGE 201, STEPS 1-3 AND MM 35-22-11, PAGE 401, STEPS 1-3.
Part: SHEAR TIE — CORRODED (FUSELAGE) · corrosion level 2 · airframe 21,103 hrs · 9,980 cycles
DURING C-7 CHECK, INSPECTION REPORTED SHEARTIE IN FWD CARGO COMPARTMENT CORRODED AT STA 500B, BETWEEN STR 27R AND 28R. REPAIRED IAW SRM 53-00-07.
Part: SHEAR TIE — CORRODED (FUSELAGE) · corrosion level 2 · airframe 21,103 hrs · 9,980 cycles
DURING C-7 CHECK, INSPECTION REPORTED SHEAR TIE IN FWD CARGO COMPARTMENT CORRODED AT STA 500B, BETWEEN STR 28L AND 28R. REPAIRED PER SRM 53-00-07.
Part: MODULE — FAULTY (FIRE DETECTION) · airframe 21,103 hrs · 9,980 cycles
DURING C-7 CHECK, INSPECTION REPORTED FIRE WARN LIGHT ON P-7, ENG 1/2 OVERHEAT LIGHTS ON P-8 AND CONTROL CABIN ALARM BELL DID NOT OPERATE IN STEPS 1 G-3 AND 1 G-7 OF FIRE WARNING SYSTEM TEST. TEST 1 G-10 PASSED. REPLACED FIRE DETECTION MODULE PER MM 26-10-01. PERFORMED ENGINE FIRE DETECTION OPERATIONAL TEST PER MM 26-11-00 AND CHECKED GOOD. PERFORMED APU FIRE DETECTION OPERATIONAL TEST PER MM 26-15-00 AND CHECKED GOOD.
Part: FLAP TRACK — CORRODED (T/E FLAP) · corrosion level 2 · airframe 21,103 hrs · 9,980 cycles
DURING C-7 CHECK, INSPECTION REPORTED CORROSION ON NR 7 OTBD FLAP TRACK ASSY. REMOVED EXISTING BUSHINGS TO EXPOSE ALL SURFACES TO INSPECTION. INSPECTED FLAP TRACK PER OHM 57-53-15. MACHINED THE HOLE FORWARD OF BUSHING NR 60 PER SOPM 20-10-01 AND SOPM 20-10-02 TO REMOVE CORROSION. PERFORMED ALL POST MACHINING REQUIREMENTS PER SOPM 20-10-02. PERFORMED MAGNETIC PARTICLE INSPECTION OF TRACK PER SOPM 20-20-01. SHOT AND/OR FLAP PEENED THE REWORKED BORE PER SOPM 20-10-03. STYLUS CADMIUM PLATED THE BORE PER SOPM 20-42-10. REFINISHED PER OHN 57-53-15.
Part: BATTERY PACK — FAILED (EVAC SLIDE) · airframe 21,103 hrs · 9,980 cycles
DURING C-7 CHECK, INSPECTION REPORTED FWD GALLEY DOOR ESCAPE SLIDE BATTERY PACK FAILED VOLTAGE TEST. REPLACED FWD GALLEY DOOR ESCAPE SLIDE.
Part: FRAME — CRACKED (FUSELAGE) · airframe 21,103 hrs · 9,980 cycles
DURING C-7 CHECK, INSPECTION REPORTED FRAME CRACKED AT BIN RAIL ATTACH BRACKET HOLE, STA 907, BETWEEN STR 8L AND 9L. REPAIRED PER SRM 53-00-07 FIG 202, STEPS 1-10.
2002
Part: STRAP — CORRODED (FUSELAGE) · corrosion level 2 · airframe 18,117 hrs · 8,212 cycles
DURING C-6 CHECK, INSPECTION REPORTED FILLER/STRAP CORRODED BETWEEN STA 787 AND 807, RBL 20 ABOVE STR 25-R. REPLACED FILLER/STRAP PER SRM 51-40-02 AND 51-10-02.
Part: WEB — CORRODED (FUSELAGE) · corrosion level 2 · airframe 18,117 hrs · 8,212 cycles
DURING C-6 CHECK, INSPECTION REPORTED WEB BETWEEN STA 794.3 AND 847, STR 25-R, CORRODED AROUND SEVERAL NUT PLATE HOLES. REPLACED AND INSTALLED WEB PER SRM 51-40-02 AND 51-10-02.
Part: STRAP — CORRODED (STA. 774 - 858) · corrosion level 2 · airframe 18,117 hrs · 8,212 cycles
DURING C-6 CHECK, INSPECTION REPORTED CORROSION ON AFT CARGO DOOR LOWER SILL STRAP, STA. 774 TO 858, RBL 20. REPLACED SILL STRAP PER SRM 51-40-07 AND 51-10-02.
Part: SUPPORT ANGLE — GOUGED (APU DOOR) · airframe 18,117 hrs · 8,212 cycles
DURING C-6 CHECK, INSPECTION REPORTED SUPPORT ANGLE ON AFT SIDE OF AFT DOOR LATCH CUTOUT GOUGED ON APU DOOR. FABRICATED NEW SUPPORT ANGLE PER SRM 52-40-02 AND 51-70-11. ALODINED AND PRIMED PER MM 51-21-41 AND SOPM 20-41-02. INSTALLED NEW ANGLE PER SRM 52-40-02 AND 51-70-11.
Part: COWL DOOR — CHAFED · airframe 18,117 hrs · 8,212 cycles
DURING C-6 CHECK, INSPECTION REPORTED PREVIOUS REPAIR ON LT. SECTION OF APU COWL DOOR CHAFFED/GROOVED. REMOVED ADDITIONAL DAMAGE FOUND AT EDGE OF PREVIOUS REPAIR. FABRICATED NEW DOUBLER TO ENCOMPASS NEW CUTOUT IN SKIN PER SRM 52-40-02, 52-40-01, MM 51-21-41 AND SOPM 20-41-02.
Part: ANGLE — CORRODED (FUSELAGE) · corrosion level 2 · airframe 18,117 hrs · 8,212 cycles
DURING C-6 CHECK, INSPECTION REPORTED CORROSION ON L-ANGLE IN FWD CARGO COMPARTMENT, STA 500D, LBL 29 TO RBL 21. REPAIRED ANGLE PER SRM 51-40-02, 51-40-05 AND 51-10-02.
Part: SHUTOFF VALVE — FAILED (NR 2 ENGINE) · airframe 17,260 hrs · 7,785 cycles
AIR TURNBACK. FLIGHT CREW REPORTED WING/BODY OVERHEAT ILLUMINATED IN FLIGHT. COMPLIED WITH CHECKLIST AND LIGHT REMAINED ILLUMINATED. PRESSURE IN RT DUCT 10 PSI, WHICH DECREASED TO 5 PSI WHEN THRUST LEVER REDUCED IN POWER. SHUT DOWN NR 2 ENGINE AND MONITORED OIL PRESSURE. REPLACED M237 MODULE AND NR 2 ENGINE PRSOV. PERFORMED OVERWEIGHT LANDING INSPECTION PER MM 05-51-74, PHASE I. NO DAMAGE NOTED. PERFORMED OPERATIONAL TESTS AND CHECKED OKAY.
2001
Part: WIRE — BROKEN (CABIN) · airframe 14,746 hrs · 6,565 cycles
PRIOR TO DEPARTURE, FLIGHT CREW REPORTED EMERGENCY EXIT FLOOR PATH WIRING EXPOSED AT ROW 15. SPLICED BROKEN WIRE PER STANDARD PRACTICES 20-30-12, PERFORMED OPERATIONAL TEST OF EMERGENCY LIGHT SYSTEM AND CHECKED OKAY.
2000
Part: FITTING — CORRODED (AFT LAVATORY) · corrosion level 2 · airframe 11,771 hrs · 5,139 cycles
DURING C-4 CHECK, INSPECTION REPORTED CORROSION AROUND RT. AFT LAVATORY OTBD AFT FLOOR MOUNT. MAINTENANCE FABRICATED AND REPLACED NEW FITTING PER EA 25-737-108.
1999
Part: BATTERY — DISCHARGED (R2 DOOR SLIDE)
DEN - DURING C-CHECK INSPECTION REPORTED R-2 EMERGENCY ESCAPE SLIDE BATTERY FAILED VOLTAGE TEST. REPLACED R-2 EMERGENCY ESCAPE SLIDE. CYCLES: 2,635. (X)
Part: BATTERY — DISCHARGED (L1 DOOR SLIDE)
DEN - DURING C-CHECK INSPECTION REPORTED L-1 EMERGENCY ESCAPE SLIDE BATTERY FAILED VOLTAGE TEST. REPLACED L-1 EMERGENCY ESCAPE SLIDE. CYCLES: 2,635. (X)
Part: BATTERY — DISCHARGED (L2 DOOR SLIDE)
DEN - DURING C-CHECK INSPECTION REPORTED L-2 EMERGENCY ESCAPE SLIDE BATTERY FAILED VOLTAGE TEST. REPLACED L-2 EMERGENCY ESCAPE SLIDE. CYCLES: 2,660. (X)
1997
Part: WIRE — LOOSE (CABIN)
DEN - DURING SERVICE CHECK, MAINTENANCE REPORTED WIRES DISCONNECTED FROM FLOOR PROXIMITY LIGHTING AT ROW 13. MAINTENANCE RECONNECTED WIRES AND SYSTEM CHECKED OKAY. (X)