N307JE

BOMBARDIER INC BD-100-1A10 · 2006 · Valid Registration

Registered owner: TVPX AIRCRAFT SOLUTIONS INC TRUSTEE, UT (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

J · 2025-06-21 Matched by certificate designator
ATA 3230

ON SHORT FINAL BELOW 500' AUDIO ALERT TOO LOW GEAR. ON FIRST GO AROUND ELECTED NOT TO RAISE GEAR ON THE DOWN THREE GREEN INDICATION. ON SECOND ATTEMPT WITH SAME ALERT ELECTED TO RAISE GEAR AND EXECUTE A NORMAL PATTERN. THIRD LANDING ATTEMPT WAS NORMAL. MX C/A: INTERROGATED MDC, FOUND NO RELATED FAULTS FOR PROXIMITY SYSTEM. CUSTOMER REQUEST TO PERFORM A TAWS OPERATIONAL CHECK. COMPLIED WITH OPS CHECK TASK 34-42-01-710-802 (2.) A-E STEPS 1-14. STEP 15 REQUIRES OPENING OF HYD CIRCUIT BREAKERS AND POSITION GEAR HANDLE UP. WILL NEED TO BE PLACED ON JACKS FOR THIS PORTION OF TEST ALONG WITH GEAR SWINGS. MCC SENT IN DOWNLOADS TO CRC FOR REVIEW. PER MCC AND CRC REPLACED LANDING GEAR CONTROL PANEL ASSEMBLY WITH CUSTOMER SUPPLIED NEW PART PER CHALLENGER 300 AMM CH 32-31-13 AND C/W TAWS OPERATIONAL CHECK TASK 34-42-01. ALL OPS CHECKS GOOD.

Source: SDR U5QA202506210154 · FAA SDRS