N312NV

AIRBUS A319-111 · 2004 · Fixed-wing multi-engine · 2 engines · 147 seats · Valid Registration

Registered owner: SUNRISE ASSET MANAGEMENT LLC, NV (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

33 reports on file, 2018-08-07 – 2026-07-31.

SMOKE/FUMES/ODORS/SPARKS · 2026-07-31 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 56,625 hrs · 37,433 cycles

(AIRCRAFT NOT GROUNDED) DURING TAKE OFF, AFT FA'S 2 & 4 HAD A DIRTY SOCK ODOR. LASTED ABOUT 3 MIN DURING + AFTER TAKE OFF. INTENSITY OF ODOR WAS MODERATE & LIGHT PER FA'S. NO VISIBLE SMOKE EITHER, AIR SOURCE USED AT GATE WAS GROUND AIR & THEN APU AIR, ENG START APU. APU BLEED OFF DURING T/O. XBLEED OFF, PACK 1 & 2 ON, BLEED 1 & 2 ON, WEATHER WAS 28C WINDS 027/07 & DRY / PERFORMED TC 001 AND LEVEL A DECON IAW AMM 21-00-00-815-802-A. NO ODOR REPRODUCED.

Source: SDR WX0A2026073132906
Earlier reports · 2018–2025 · 32 reports

2025

NO TEST · 2025-08-03 Matched by certificate designator
ATA 2560

Part: BATTERY — NO TEST (ZONE 800) · airframe 54,900 hrs · 36,403 cycles

(AIRCRAFT NOT GROUNDED) AFT F2 FA FLASHLIGHT NOT CHARGED / REPLACED BATTERY W/REF TO CMM 25-60-02. OPS CHECK GOOD"

Source: SDR WX0A2025080432523
FLUID LOSS; SMOKE/FUMES/ODORS/SPARKS · 2025-05-23 Matched by certificate designator
ATA 4990

Part: TUBE — LEAKING (APU OIL COOLER) · airframe 54,392 hrs · 36,175 cycles

(AIRCRAFT GROUNDED) DIRTY SOCK SMELL ON DESCENT. FOUND APU LEAKING OIL. REF. WO 522043 FOR PARTS REPLACEMENT. APU OIL COOLER FAN OIL TRANSFER TUBE LEAKING OIL. REMOVED COOLING FAN, REPLACED O-RINGS, AND REINSTALLED REF AMM 49-52-51-04 CONF 16. RAN APU FOR ONE HOUR, LEAK CHECK GOOD. COMPLETED TC 21-000-003, LEVEL A DECON OF ECS REF AIRBUS AMM 21-00-00-615-802-A. NO SMELL DETECTED, OPS CHECK GOOD. REPLACED APU FCU IAW AMM 49-32-11-000-003-A & 49-32-11-400-003-A. OPS CHECK GOOD AT THIS TIME, NO LEAKS NOTED AT THIS TIME. COMPLETED TC 21-000-003, LEVEL A DECON OF ECS REF AIRBUS AMM 21-00-00-615-802-A. NO SMELL DETECTED, OPS CHECK GOOD.

Source: SDR WX0A2025052732439
OTHER · 2025-05-09 Matched by certificate designator
ATA 2560

Part: SEAL — BROKEN (PBE) · airframe 54,330 hrs · 36,135 cycles

(AIRCRAFT GROUNDED) LEAD FA JUMPSEAT PBE SEAL BROKEN / REMOVED AND REPLACED FWD PBE TAMPER SEAL IAW AMM 35-32-52-300-001-A. THIS CLEARS MEL 35-32-01-B MDDR 212160. NO ""M"" PROCEDURES. INOP PLACARD REMOVED. "

Source: SDR WX0A2025051232423
WARNING INDICATION; ENGINE STOPPAGE · 2025-01-03 Matched by certificate designator
ATA 7200

Part: WARNING MESSAGE — ILLUMINATED (NR 1 ENGINE) · airframe 53,560 hrs · 35,777 cycles

(AIRCRAFT GROUNDED) (EMERGENCY DECLARED) ADV FOR LOW ENG OIL QTY FOLLOWED BY LOSS OF OIL PSI IN #1 ENG ECAM FOR SHUTDOWN OF ENG 1 ORDERED. FOLLOWED ECAM AND QRH PROCEDURES. FROM ECAM TO ENG SHUT DOWN WAS AN ESTIMATED GUESS OF 20 OR LESS SECONDS. / (RESOLVED ON W/O: 510919 TASKCARD: NR-00001 ) C/W DEFECT 8146 #1 ENG REMOVED AND REPLACED PER TASK CARD 71-400-001. ITEM: 1REMOVED AND REPLACED #1 ENG IAW AMM 71-00-00-000-042, AND 71-00-00-400-042. OPS TEST GOOD. C/W DEFECT 8146 #1 ENG REMOVED AND REPLACED PER TASK CARD 71-400-001.

Source: SDR WX0A2025010332254

2024

NO TEST · 2024-12-23 Matched by certificate designator
ATA 3350

Part: EPSU — NO TEST (ZONE 200) · airframe 53,467 hrs · 35,723 cycles

(AIRCRAFT NOT GROUNDED) FAILED T/C TEST / R/R EPSU REF WO509816"

Source: SDR WX0A2025010232250
NO TEST · 2024-12-23 Matched by certificate designator
ATA 3350

Part: EPSU — NO TEST (ZONE 200) · airframe 53,467 hrs · 35,723 cycles

(AIRCRAFT NOT GROUNDED) FAILED T/C TEST / R/R EPSU REF WO509816"

Source: SDR WX0A2025010232247
NO TEST · 2024-12-23 Matched by certificate designator
ATA 3350

Part: EPSU — NO TEST (ZONE 200) · airframe 53,467 hrs · 35,723 cycles

(AIRCRAFT NOT GROUNDED) FAILED T/C TEST / R/R EPSU REF WO509816"

Source: SDR WX0A2025010232248
NO TEST · 2024-12-23 Matched by certificate designator
ATA 3350

Part: EPSU — NO TEST (ZONE 200) · airframe 53,467 hrs · 35,723 cycles

(AIRCRAFT NOT GROUNDED) FAILED T/C TEST / R/R EPSU REF WO509816"

Source: SDR WX0A2025010232249
NO WARNING INDICATION · 2024-12-17 Matched by certificate designator
ATA 3350

Part: LENS — MISSING (RH OVERWING EXIT) · airframe 53,424 hrs · 35,699 cycles

(AIRCRAFT NOT GROUNDED) RH OVERWING CABIN WALL-MOUNTED EMERGENCY-EXIT-MARKER LENS COVER MISSING / INSTALLED NEW RH OVERWING EMERGENCY-EXIT-MARKER LENS COVER IAW AMM 33-51-13-400-001-A."

Source: SDR WX0A2024122032236
OTHER · 2024-04-22 Matched by certificate designator
ATA 3350

Part: LENS — WRONG PART (EMERGENCY LIGHT) · airframe 52,191 hrs · 35,055 cycles

CABIN SIDE WALL EMERGENCY LIGHT HAD THE INCORRECT COVER INSTALLED. R & R CABIN SIDE WALL EMERGENCY LIGHT COVER IAW AMM 33-51-13-000-001-A & 33-51-13-400-001-A.

Source: SDR WX0A2024042232017
OTHER · 2024-04-15 Matched by certificate designator
ATA 2560

Part: MEGAPHONE — INOPERATIVE (CABIN) · airframe 52,157 hrs · 35,043 cycles

FORWARD MEGAPHONE NOT WORKING / FORWARD MEGAPHONE OPERATING INTERMITTENLY, REMOVED AND REPLACED PER LOPA A1250004L03 REV 02."

Source: SDR WX0A2024041632011

2023

INADEQUATE Q C · 2023-12-03 Matched by certificate designator
ATA 2560

Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 51,488 hrs · 34,704 cycles

FO ESCAPE ROPE IMPROPERLY STOWED SO AS TO BE UNUSEABLE. IT IS JAMMED BEHIND MOLDING. / PROPERLY STOWED FO ESCAPE ROPE IAW AMM 25-13-00. NO DEFECTS NOTED AT THIS TIME. AIRCRAFT IS OK FOR SERVICE"

Source: SDR WX0A2023120431908
WARNING INDICATION · 2023-10-25 Matched by certificate designator
ATA 3350

Part: EPSU — UNKNOWN (UNKNOWN) · airframe 51,355 hrs · 34,631 cycles

ALL EMERGENCY LIGHT RELATED TO EPSU BATTERY 10WL INOP. / EMERGENCY POWER SUPPLY UNIT (EPSU) 10WL REPLACED AND TESTED SERVICEABLE IAW AMM 35-51-38-000/400-001-A."

Source: SDR WX0A2023103031877
OTHER · 2023-10-21 Matched by certificate designator
ATA 5350

Part: TAIL CONE — UNKNOWN (UNKNOWN) · airframe 51,355 hrs · 34,631 cycles

TAIL CONE UPPER SKIN DENTED ON LH SIDE / TAIL CONE UPPER SKIN ON L/H SIDE DENT WAS EVALUATED AS PER SRM 53-51-11-283-024 REV. 146 AND REPAIRED AS PER SRM 53-51-11-300-010 REV 146 FIG 001. PERMANENT MAJOR REPAIR CATEGORY A. NO FURTHER ACTION REQUIRED."

Source: SDR WX0A1900010031874
OTHER · 2023-10-21 Matched by certificate designator
ATA 5350

Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 51,355 hrs · 34,631 cycles

TAIL CONE UPPER SKIN DENTED ON L/H SIDE / TAIL CONE UPPER SKIN ON L/H SIDE DENT WAS EVALUATED AS PER SRM 53-51-11-283-024 REV. 146 AND REPAIRED AS PER SRM 53-51-11-300-010 REV 146 FIG 001. PERMANENT MAJOR REPAIR CATEGORY A. NO FURTHER ACTION REQUIRED. SEE AWS AND NDT REPORT FOR STEP DETAILS. SEE ALLEGIANT FORM M360 FOR DENT DIMENSION."

Source: SDR WX0A1900010031885
WARNING INDICATION · 2023-09-04 Matched by certificate designator
ATA 3350

Part: EPSU — UNKNOWN (UNKNOWN) · airframe 51,295 hrs · 34,592 cycles

BAT/EPSU (12WL) EMER R CLASS 1 / R&R EPSU BATTERY 12 WL IAW AMM REF 33-51-38-000-002-A AND 33-51-38-400-002-A"

Source: SDR WX0A2023090531830
WARNING INDICATION · 2023-04-26 Matched by certificate designator
ATA 3350

Part: EPSU — UNKNOWN (UNKNOWN) · airframe 50,650 hrs · 34,223 cycles

EPSU BATTERY LOCATED AT 13WL TRIGGERING UNIT FAULT / REMOVED AND REPLACED EPSU BATTERY LOCATED AT 13WL. OPS TEST GOOD. REF AMM 33-51-38-000-002-A & 33-51-38-400-002-A."

Source: SDR WX0A2023042831757
OTHER · 2023-03-10 Unresolved
ATA 5341

Part: FRAME — UNKNOWN (ZONE 100) · airframe 49,556 hrs · 33,641 cycles

DURING TASK INSPECTION 53-260-003 REAR FUSELAGE AFT PAX DOOR STOP FITTING # 1 CRACK WAS FOUND. PERMANENT REPAIR AT AFT ENTRY DOOR FRAME 68LH AT LOWER I/B HOLE DOOR STOP FITTING IAW A319 SRM TASK 53-41-12-300-011 PARAG 2.A TABLE 004 FIGURE 008 (SHEET 1,2,AND 3) PER INSTRUCTIONS OF COOPESA EO # COO-EO-2023-16107-R00 AND AIRBUS DOSSIER 81105869.

Source: SDR EE4Y2023031017407

2022

OTHER · 2022-11-14 Matched by certificate designator
ATA 2560

Part: MEGAPHONE — BROKEN (CABIN) · airframe 49,797 hrs · 33,757 cycles

FA MEGAPHONE BROKEN. / REMOVED AND INSTALLED FWD MEGAPHONE IAW A/C LOPA DRAWING # A1250004L03 OPS CK GOOD IAW AMM 25-65-51."

Source: SDR WX0A2022111631781
NO WARNING INDICATION · 2022-08-12 Matched by certificate designator
ATA 7500

Part: A/C PACK — TRIPPED · airframe 49,538 hrs · 33,635 cycles

ENG 2 FIRE ECAM 3000 FEET ON DEPARTURE. ENG SHUT DOWN PER ECAM. REPLACEMENT OF OUTER T/T HALF ASSY, ENG 2 LOWER HP DUCTS"

Source: SDR WX0A2022081274205
NO WARNING INDICATION · 2022-07-19 Matched by certificate designator
ATA 3350

Part: BATTERY — FAILED · airframe 49,438 hrs · 33,589 cycles

REF W,O, 459481 EMERGENCY BATTERY CAPACITY CHECK FAILED PACKS 10WL AND 13WL PARTS ON ORDER / R&R BOTH EMERGENCY POWER SUPPLY UNITS 10WL AND 13WL IAW AMM 33-51-38-000-001-A/33-51-38-400-002-A OPS CHKS GOOD"

Source: SDR WX0A2022072074164
NO WARNING INDICATION · 2022-03-16 Matched by certificate designator
ATA 3350

Part: EPSU — FAILED INSP · airframe 48,755 hrs · 33,224 cycles

10WL BATTERY FAILED EPSU SYSTEM TEST / REMOVED AND REPLACED BATTERY ON 10WL IAW AMM 33-51-38-000-002-A AND AMM 33-51-38-400-002-A. OPS CHECK GOOD"

Source: SDR WX0A2022031674030
WARNING INDICATION · 2022-01-22 Matched by certificate designator
ATA 3350

Part: EPSU — INOPERATIVE · airframe 48,392 hrs · 32,998 cycles

FOUND CLASS 1 EPSU (12WL) EMER R MESSAGE. / REMOVED AND REPLACED BATTERY PACK AT 12WL IAW AMM 33-51-38-000-002-A AND 33-51-38-400-002-A. OPS CHECK GOOD AT THIS TIME."

Source: SDR WX0A2022012473934

2021

OTHER · 2021-09-29 Matched by certificate designator
ATA 5754

Part: SLAT — WORN (ZONE 500) · airframe 47,928 hrs · 32,759 cycles

DURING THE VISUAL INSPECTION PER ALLEGIANT TASK CARD 574405-01-1-001_P1-OP-UP/0, AT LH WING IT WAS FOUND THE SLAT #3 INBOARD END TRAILING EDGE WITH WEAR. CORRECTIVE ACTION: PERMANENT REPAIR WAS PERFORMED AS PER A319 SRM TASK 57-44-21-300-011 REV 138 DTD 08-01-2021. FOR ADDITIONAL INFORMATION SEE COOPESA´S WORK ORDER A1K253 SUB JOB 5 ITEM 11.

Source: SDR EE4Y2023031017361
OTHER · 2021-08-25 Matched by certificate designator
ATA 5300

Part: PRESSURE PLATE — CRACKED (ZONE 100) · airframe 47,928 hrs · 32,759 cycles

WHILE PERFORMING INSPECTION AND REPAIR PER ALLEGIANT E.O. E5331-0007 R3 RELATED TO AD2018-06-04, PRESSURE PLATE FASTENER HOLES WERE FOUND CRACKED BETWEEN FR35-FR36 UNDER LONGITUDINAL BEAM. CORRECTIVE ACTION: PERMANENT REPAIR WAS PERFORMED AS PER E.O. E5331-0007 R3 RELATED TO AD2018-06-04. FOR ADDITIONAL INFORMATION SEE COOPESA´S WORK ORDER A1K253 SUB JOB 9 ITEM 3.

Source: SDR EE4Y2023031017362
OTHER · 2021-07-26 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — FAULTED (EMERGENCY LIGHT) · airframe 47,558 hrs · 32,558 cycles

AFT CENTER EMERGENCY POWER SUPPLY UNIT (EPSU) BATTERY FAULT, REQUIRES CHANGE / AFT CENTER EMERGENCY POWER SUPPLY UNIT (EPSU) BATTERY REMOVED AND REPLACED IAW AMM 33-51-38-000-002-A AND 33-51-38-400-002-A, OPS CHECK GOOD"

Source: SDR WX0A2021072673797
OTHER · 2021-07-25 Matched by certificate designator
ATA 3350

Part: LENS — DETACHED (EMERGENCY LIGHT) · airframe 47,553 hrs · 32,556 cycles

EMERGENCY EXIT LIGHT COVER AT SEAT 14A FELL OFF / REPLACED BROKEN BLANKING CAP ROW 14ABC IAW AMM 33-51-13-000-001-A AND AMM 33-51-13-400-001-A."

Source: SDR WX0A20210726797
NO TEST · 2021-04-14 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 46,826 hrs · 32,168 cycles

ESPU (13WL) BATT FAILED ""CABIN EMERGENCY LIGHTING"" WORK CARD 335100-03-1-001. / REPLACED EPSU (13WL) BATT, BITE CHECKED NORMAL, IAW TSM 33-51-00-810-857-A & AMM 33-51-38-400-002-A."

Source: SDR WX0A2021041673684

2020

NO TEST · 2020-09-26 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 45,785 hrs · 31,586 cycles

EMERGENCY LIGHTING BATTERY RT FIN (12WL) ECAM FAILURE MESSAGE ON START OF BATTERY CAP TEST. NEEDS TO BE REPLACED BEFORE BATTERY CAP TEST CAN START AND CONTINUE. REMOVED EMERGENCY POWER SUPPLY BATTERY FROM RT POWER SUPPLY, IAW AMM 33-51-38-000-002-A AND INSTALLED NEW BATTERY, IAW AMM 33-51-38-400-002-A. POWER UP TEST GOOD.

Source: SDR WX0A2020092873582
NO TEST · 2020-05-23 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 45,078 hrs · 31,208 cycles

EPSU BATTERY FIN# 10WL FAILED EPSU CAPACITY TEST. REPLACED THE EPSU BATTERY.

Source: SDR WX0A2020052537508

2019

NO TEST · 2019-07-14 Matched by certificate designator
ATA 2560

Part: MEGAPHONE — INOPERATIVE (CABIN)

FWD MEGAPHONE INOP. R&R MEGAPHONE.

Source: SDR WX0A2019071573406

2018

FLUID LOSS; SMOKE/FUMES/ODORS/SPARKS · 2018-08-07 Matched by certificate designator
ATA 4930

Part: FCU — LEAKING (APU ENGINE) · airframe 41,155 hrs · 29,119 cycles

FA REPORTED A DIRTY SOCK ODOR DURING FLIGHT. FOUND THE APU FUEL CONTROL DRAIN LEAKING. R & R THE APU FUEL CONTROL UNIT.

Source: SDR WX0A2018081073366