N31703

BEECH 1900C · 1984 · Fixed-wing multi-engine · 2 engines · 19 seats · Valid Registration

Registered owner: UAS TRANSERVICES INC, FL (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
Ameriflight, LLC (JIKA)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

5 reports on file, 2015-11-02 – 2026-04-27.

OTHER · 2026-04-27 Matched by certificate designator
ATA 5531

Part: SPAR ANGLE — CORRODED (ZONE 300) · airframe 44,513 hrs · 59,868 cycles

DURING AN EVENT 6 SCHEDULED INSPECTION OF BEECHCRAFT MODEL 1900C AIRCRAFT N31703 (SERIAL NUMBER UB-10), PDX MAINTENANCE FOUND CORROSION ON THE VERTICAL STABILIZER REAR SPAR LH ANGLE THAT EXCEEDED THE REPAIR LIMITS IN TEXTRON 1900C SRM CHAPTERS 51-40-02 AND 51-40-06, REVISION D0, DATED MAY 1, 2019. AMERIFLIGHT PART 145, JIKR213F, REPLACED THE LH ANGLE WITH A NEWLY MANUFACTURED HAWKER BEECHCRAFT ANGLE EXTRUSION, PART NUMBER 101-640010-10. THE REPAIR STATION ALSO CONDUCTED A HIDDEN DAMAGE INSPECTION AND FOUND NO ADDITIONAL DAMAGE. REFERENCE WORK ORDER #0011272, DATED MAY 14, 2026.

Source: SDR JIKA2026051901
OTHER · 2023-11-09 Matched by certificate designator
ATA 2720

Part: CABLE — BROKEN (ZONE 100) · airframe 43,523 hrs · 58,491 cycles

PILOT REPORTED THAT HE HAD NO RIGHT-HAND RUDDER CONTROL ON APPROACH. THE LEFT-HAND RUDDER AND RUDDER TRIM WERE NORMAL. MAINTENANCE FOUND A SEPARATED FLIGHT CONTROL CABLE AND IS IN THE PROCESS OF REPLACING IT. BEFORE RETURNING THE AIRCRAFT TO SERVICE.

Source: SDR JIKA20231113901
WARNING INDICATION · 2021-07-14 Matched by certificate designator
ATA 7312

Part: FUEL HEATER — CRACKED (RIGHT) · airframe 42,591 hrs · 56,924 cycles

AFTER TAKE OFF FROM KRDM, THE FLIGHT CREW REPORTED RIGHT OIL PRESSURE WARNING ANNUNCIATOR FLICKERED AND RIGHT OIL PRESSURE INDICATIONS DROPPED TO 50 PSI. AFTER LANDING FOUND OIL LEAKING FROM RIGHT NACELLE, TROUBLESHOOTING MFOUND A CRACK IN FUEL HEATER. MAINTENANCE REPLACED FUEL OIL HEATER, OPERATION AND LEAK CHECK GOOD.

Source: SDR JIKA2021071401
OTHER · 2019-05-13 Matched by certificate designator
ATA 3260

Part: INDICATION SYS — MALFUNCTIONED (COCKPIT) · airframe 41,859 hrs · 55,739 cycles

DISCREPANCY: THE PILOT REPORTED WHILE ON APPROACH TO KPRC, WHEN THE LANDING GEAR WAS SELECTED TO THE DOWN POSITION THAT THE NOSE GEAR INDICATION DID NOT ILLUMINATE. THE PILOT NOTIFIED ATC AND PERFORMED A FLY-BY OF KPRC TOWER FOR CONFIRMATION OF ALL 3 GEAR DOWN, AND THIS WAS CONFIRMED. THE PILOT REQUESTED TO EXIT PATTERN TO TROUBLE SHOOT AND TALK TO COMPANY. THEN TRIED THE PUSH TO TEST FEATURE AND STILL NO ILLUMINATION OF THE NOSE GEAR DOWN INDICATION. THEN THE PILOT DIVERTED TO KPHX PASSING BY KSCF TOWER AND CONFIRMING A SECOND TIME GEAR WAS DOWN. THE PILOT FOLLOWING PROCEDURE PERFORMED A MANUAL GEAR EXTENSION AND DECLARED AN EMERGENCY THEN LANDED IN KPHX WITHOUT FURTHER INCIDENT. MAINTENANCE CORRECTIVE ACTION: MAINTENANCE INSPECTED THE NOSE LANDING GEAR AND INDICATION SYSTEM. MAINTENANCE PERFORMED SEVERAL GEAR SWINGS AND RIGGING CHECKS WITH NO DEFECTS NOTED. MAINTENANCE AS PRECAUTIONARY REPLACED ALL P\N MS25237-327 LAMPS WITH NEW UNITS. THE OPERATION OF THE LANDING GEAR AND INDICATION SYSTEM WAS NORMAL. THE AIRCRAFT WAS RETURNED TO SERVICE AND NO SUBSEQUENT ISSUES HAVE BEEN REPORTED.

Source: SDR JIKA2019051302
SMOKE/FUMES/ODORS/SPARKS · 2015-11-02 Matched by certificate designator
ATA 2751

Part: MOTOR — MALFUNCTIONED (TE FLAP) · airframe 39,269 hrs · 53,052 cycles

AFTER TAKEOFF THE PILOT NOTICED A SMOKE SMELL IN COCKPIT. THE PILOT NOTIFIED THE TOWER & DECLARED AN EMER. THE PILOT RETURNED & LANDED WITHOUT INCIDENT. TROUBLESHOOTING REVEALED A FAULTY ELEC FLAP MOTOR & GEAR BOX ASSEMBLY. REPLACED ELEC FLAP MOTOR & GEAR BOX ASSEMBLY & PERFORMED FLAP SYS OPERATIONAL CHECKS. ALL CHECKS WERE NORMAL.

Source: SDR JIKA2015110201