N317AZ
Registered owner: CARGO AIRCRAFT MANAGEMENT INC, OH (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
21 reports on file, 2021-02-23 – 2026-10-17.
Part: ROLLER — OUT OF RIG (WINDOW) · airframe 109,884 hrs · 20,886 cycles
R2 WINDOW WILL NOT CLOSE. ADJUSTED R2 WINDOW TOP AND BOTTOM AFT ROLLER CLUSTERS IAW B767 AMM 56-11-02. WINDOW OPERATES NORMALLY.
Part: SLAT SYSTEM — NO DISCREPANCY · airframe 109,713 hrs · 20,822 cycles
SLATS PROBABLE OVERSPEED. "LE SLAT ASYM" AT APPROXIMATELY 170 KNOTS. IMMEDIATELY SLOWED TO BELOW 250 KNOTS. INDICATING BETWEEN UP AND 1° AND ALTITUDE 25,000 TO 33,000 APPROXIMATELY. CREW ELECTED TO RETURN TO ORIGINATING STATION. EMERGENCY WAS DECLARED. AIRCRAFT LANDED WITHOUT INCIDENT. AIRCRAFT WAS GROUNDED FOR MAINTENANCE AND INSPECTION. ACCOMPLISHED FLAP/SLAT DOWN OVERSPEED CONDITIONAL INSPECTION PHASE I IAW AMM 05-51-08. NO DEFECTS NOTED AT THIS TIME.
Part: SLIDING WINDOW — INOPERATIVE (ZONE 200) · airframe 109,653 hrs · 20,795 cycles
CO-PILOT'S WINDOW WILL NOT CLOSE. FOUND AND REMOVED EXCESS RTV AROUND SEAL. OPERATIONAL CHECK IAW AMM 56-11-02, NO FAULTS.
Earlier reports · 2021–2025 · 18 reports
2025
Part: BATTERY PACK — INOPERATIVE (ZONE 200) · airframe 107,746 hrs · 19,977 cycles
EMERGENCY LIGHT L9801, L9803 AND THE EXTERIOR EMERGENCY LIGHTS ARE INOPERATIVE. FAULT PLACED ON MAINTENANCE DEFERRAL 65186, CATEGORY D DUE ON 10 DECEMBER 2025. REMOVED AND REPLACED EMERGENCY BATTERY AND POWER SUPPLY IN FORWARD POSITION IN ACCORDANCE WITH BOEING 767 AIRCRAFT MAINTENANCE MANUAL 33-51-07. OPERATIONAL CHECK GOOD. DEFERRAL 65186 CLEARED.
Part: SKIN PANEL — DELAMINATED (ZONE 300) · airframe 107,198 hrs · 19,744 cycles
LEFT HORIZ STAB UPPER SKIN PANEL DISBONDED LE STA 250.
Part: SKIN PANEL — CORRODED (ZONE 300) · airframe 107,198 hrs · 19,744 cycles
LEFT HORIZ STAB UPPER SKIN PANEL LE STA 250-305 INTERNAL SKIN DISBONDED
Part: SUPPORT WEB — CORRODED (ZONE 100) · corrosion level 2 · airframe 107,198 hrs · 19,744 cycles
CORROSION ON UPPER BILGE PANEL ALC 1335 RBL16
Part: BRACKET — CORRODED (ZONE 100) · corrosion level 2 · airframe 107,198 hrs · 19,744 cycles
FLC ROLLER TRAY STAND-OFF BRACKET CORRODED STA 478, LBL44
Part: BRACKET — CORRODED (ZONE 100) · corrosion level 2 · airframe 107,198 hrs · 19,744 cycles
FLC CARGO DOOR LOWER SEAL DEPRESSOR BRACKET CORROED AT STA 578
Part: PANEL — CORRODED (ZONE 100) · corrosion level 2 · airframe 107,198 hrs · 19,744 cycles
UPPER BILGE PANEL AT FS 1335 RBL16 FOUND BOTH THE LEFT AND RIGHT BILGE PANELS CORRODED
Part: SKIN — CRACKED (ZONE 100) · airframe 107,198 hrs · 19,744 cycles
CRACK ON SKIN AT STRINGER 23L STATION 654+28
Part: SHIM — CORRODED (NOT REPORTED) · corrosion level 2 · airframe 68,045 hrs · 26,231 cycles
FOUND CORROSION ON SHIM TO BE OUT OF LIMITS
Part: FRAME — CORRODED · airframe 107,198 hrs · 19,744 cycles
LEFT FUSELAGE STATION 1197 +88 APPROX S-12L FOUND CORROSION SPOT ON FRAME
2023
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 104,589 hrs · 18,752 cycles
ENROUTE FROM KSFO TO KBWI CREW REPORTED FWD EQUIPT COOLING OVHT CAUTION AND CABIN ALTITUDE WARNING MESSAGES DISPLAYED WITH A LOSS OF PRESSURIZATION. IN COMPLIANCE OF ATI QUICK REFERENCE HANDBOOK PROCEDURES, CREW DESCENDED TO 10,000 FT AND DIVERTED TO KILN WITH AN EMERGENCY DECLARATION. LANDING WAS WITHOUT INCIDENT AND ON ARRIVAL THE AIRCRAFT WAS GROUNDED FOR MAINTENANCE. INSPECTION OF EQUIPMENT COOLING DUCTS SATISFACTORY. NO FAULTS FOUND. PER B767 IAI FAULT ISOLATION MANUAL 21-58-00, FORWARD LOW FLOW DETECTOR REMOVED AND REPLACED IAW B767 AMM 21-58-17. ADDITIONALLY, AT MAINTENANCE OPERATIONS CONTROL REQUEST REMOVED AND REPLACED COOLING DUCT VALVE ASSEMBLY PER B767 AMM 21-58-01. OPERATIONAL AND LEAK CHECKS GOOD. NO ADDITIONAL SYSTEM FAULTS NOTED. 17 DECEMBER 2023 FUNCTIONAL FLIGHT CHECK ATN317 FOR VERIFICATION OF CORRECTIVE ACTIONS SATISFACTORY. NO FAULT MESSAGES PRESENTED IN FLIGHT. AIRCRAFT RETURNED TO SERVICE.
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 104,589 hrs · 18,752 cycles
ENROUTE FROM KSFO TO KBWI CREW REPORTED FWD EQUIPT COOLING OVHT CAUTION AND CABIN ALTITUDE WARNING MESSAGES DISPLAYED WITH A LOSS OF PRESSURIZATION. IN COMPLIANCE OF ATI QUICK REFERENCE HANDBOOK PROCEDURES, CREW DESCENDED TO 10,000 FT AND DIVERTED TO KILN WITH AN EMERGENCY DECLARATION. LANDING WAS WITHOUT INCIDENT AND ON ARRIVAL THE AIRCRAFT WAS GROUNDED FOR MAINTENANCE. INSPECTION OF EQUIPMENT COOLING DUCTS SATISFACTORY. NO FAULTS FOUND. PER B767 IAI FAULT ISOLATION MANUAL 21-58-00, FORWARD LOW FLOW DETECTOR REMOVED AND REPLACED. IAW B767 AMM 21-58-17. ADDITIONALLY, AT MAINTENANCE OPERATIONS CONTROL REQUEST REMOVED AND REPLACED. COOLING DUCT VALVE ASSEMBLY PER B767 AMM 21-58-01. OPERATIONAL AND LEAK CHECKS GOOD. NO ADDITIONAL SYSTEM FAULTS NOTED. 17 DECEMBER 2023, FUNCTIONAL FLIGHT CHECK ATN317 FOR VERIFICATION OF CORRECTIVE ACTIONS SATISFACTORY. NO FAULT MESSAGES PRESENTED IN FLIGHT. AIRCRAFT RETURNED TO SERVICE.
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 103,898 hrs · 18,474 cycles
IN CLIMB MODE RIGHT THRUST LEVER DOES NOT RESPOND TO MANUAL INPUTS REGARDLESS IF AUTOTHROTTLE MODE IS ON OR OFF. ALTERNATIVELY, IN CRUISE AND DESCENT MODE THE RIGHT THRUST LEVER WILL RESPOND. PRECAUTIONARY, CREW DECLARED EMERGENCY WITH DESTINATION STATION (KCVG) AIR TRAFFIC CONTROL. LANDING WAS WITHOUT INCIDENT AND NO ADDITIONAL PRECAUTIONARY ACTIONS NOTED. ON ARRIVAL, AIRCRAFT GROUNDED FOR UNSCHEDULED MAINTENANCE. IAW B767 AMM 76-11-00 DETAILED VISUAL INSPECTION OF THRUST CONTROL SYSTEM SATISFACTORY. WITH HIGH POWER ENGINE RUN, POWERPLANT TEST 4, 11, AND 12 GOOD. NO FAULT MESSAGES OR INDICATIONS DISPLAYED. CREW REPORTED FAULT NOT DUPLICATED. ALL AUTOTHROTTLE POWER LEVER ANGLE AND THRUST LEVER ANGLE CHECKS GOOD IAW B767 AMM 71-00-00, 22-33-01 AND 73-21-09.
Part: SKIN — CRACKED (ZONE 600) · airframe 103,164 hrs · 18,180 cycles
RW LEADING EDGE SKIN DAMAGED BEHIND #7 SLAT
Part: SKIN — CRACKED (ZONE 200) · airframe 103,041 hrs · 18,138 cycles
LH FUSELAGE FORWARD ENTRY DOOR CUTOUT AFT LOWER CORNER HAS CRACK AT FASTENER HOLE.
Part: SKIN — CRACKED (ZONE 200) · airframe 103,041 hrs · 18,138 cycles
FUSELAGE FWD SERVICE DOOR CUTOUT AFT LOWER CORNER LOWER FASTENER CRACK INDICATION
2021
Part: TENSION TIE — NOT REPORTED (BULKHEAD) · corrosion level 2 · airframe 98,512 hrs · 16,604 cycles
COMPLY WITH FVCI #21011-5 FABRICATION TENSION FITTING REAR SPAR BULKHEAD 100T1432-3. FABRICATED CENTER WING TENSION FITTING PN-100T1432-3 PER FA BAS 21019 REV 1R, FVCI EO 21011-5 REV B AND 8110-3 DATED 8 MARCH 2021.
Part: SKIN — CORRODED (BS 952) · corrosion level 2 · airframe 98,512 hrs · 16,604 cycles
AFTER CLEANING INBOUND SIDE OF CENTER TANK AREA FOUND CORROSION ON UPPER SKIN AREA AT STA 952, BETWEEN 8 TO 12 INCH FROM FUSELAGE SKIN TO INBOUND SIDE. ACCOMPLISHED REPAIR ON CENTER WING SKIN AT STA 952 IAW FAS EA 21019 REV 1R, FVCI E0 21011-4 REV B AND 8110-3 DATED 01 MARCH 2021.