N322NV

AIRBUS A319-111 · Fixed-wing multi-engine · 2 engines · 147 seats · Valid Registration

Registered owner: SUNRISE ASSET MANAGEMENT LLC, NV (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

22 reports on file, 2019-04-19 – 2026-08-16.

SMOKE/FUMES/ODORS/SPARKS · 2026-08-16 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 53,109 hrs · 35,495 cycles

(AIRCRAFT NOT GROUNDED) FA REPORT LOCKER ROOM SMELL STARTING AT DESENT THROUGH FL180 AND DISSIPATING AT GEAR DOWN . EVENT REPORTED TO PIC AT GATE / PERFORMED 21-000-001 DECONTAMINATION FOR APU LEAK / DIRTY SOCK SMELL C/W AMM 21-00-00-615-802-A , REF LOGPAGE 2193726 FOR APU DEFERAL "

Source: SDR WX0A2026081732923
OTHER · 2026-08-04 Matched by certificate designator
ATA 5320

Part: FITTING — DAMAGED (ZONE 100) · airframe 53,033 hrs · 35,464 cycles

DURING THE EXECUTION OF ALLEGIANT WORK CARD A32X-25-127-003/001 AT THE LOWER FUSELAGE, E&E COMPARTMENT: IT WAS FOUND OVALIZATION ON THE 80VU RACK L/H AND R/H LOWER LATERAL FITTINGS. REPAIR ACTION ACCOMPLISHED: PER CUSTOMER EO A32X-STR-25-EO-00203. REV 01 AD2023-05-14, 80VU RACK ATTACHMENT- INSPECTION REPAIR ACCOMPLISHED. SEE COOPESA JOB A1R156, NRI 1-2.

Source: SDR EE4Y2026080424824
NO TEST · 2026-04-29 Matched by certificate designator
ATA 3350

Part: EPSU — NO TEST (ZONE 200) · airframe 52,592 hrs · 35,204 cycles

(AIRCRAFT NOT GROUNDED) DURING EPSU BATTERY TEST, 10WL EPSU FAILED IMMEDIATELY / REMOVED/REPLACED EPSU (10WL) IAW AMM 33-51-38-000/400-001A."

Source: SDR WX0A2026050132801
FLUID LOSS; SMOKE/FUMES/ODORS/SPARKS · 2026-04-20 Matched by certificate designator
ATA 4990

Part: OIL SYSTEM — LEAKING (APU) · airframe 52,538 hrs · 35,177 cycles

(AIRCRAFT NOT GROUNDED) DIRTY SOCK SMELL ON DESCENT REPORTED STRONGEST AFT CABIN / PERFORMED TC A32X-21-000-001 & AMM 21-00-00-615-802-A. FOUND OIL LEAKING AROUND APU INTAKE AND COMPRESSOR. APU PLACED ON MEL ON LOGPAGE 2171449. TRACKING ODOR EVENT ON MDDR 230313. TC A32X-21-000-002 MUST BE COMPLETED WITHIN 5 CALENDAR DAYS. (FOLLOWUP - DI CLOSED) (RESOLVED ON W/O: 549214 TASKCARD: NR-00001 ) CW TC A32X-21-000-002ITEM: 1CW TC A32X-21-000-002.

Source: SDR WX0A2026042232792
OTHER · 2026-04-10 Matched by certificate designator
ATA 3350

Part: LENS — MISSING (ZONE 200) · airframe 52,488 hrs · 35,147 cycles

(AIRCRAFT NOT GROUNDED) ROW 14 DEF OVER WING EMERGENCY EXIT SIGN IS MISSING / INSTALLED NEW LENS IAW AMM 33-51-13-400-001-A. THIS CLEARS NEF 25-01-A07. NEF LOG UPDATED"

Source: SDR WX0A2026041232783
Earlier reports · 2019–2025 · 17 reports

2025

NO TEST · 2025-12-11 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — NO TEST (ZONE 200) · airframe 51,824 hrs · 34,794 cycles

(AIRCRAFT NOT GROUNDED) FAILED EMG LIGHTS TEST FOR POSITION. / REMOVED AND REPLACED EPSU REF WO537971"

Source: SDR WX0A2025121232665
SMOKE/FUMES/ODORS/SPARKS · 2025-10-24 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 51,586 hrs · 34,665 cycles

(AIRCRAFT NOT GROUNDED) CHEMICAL / DIRTY SOCK ODOR REPORTED ROWS 23 TO AFT GALLEY. COMPLIED WITH QRH. ODOR DISSIPATED WITH PACK 2 OFF BUT RETURNED DURING DESCENT THEN DISSIPATED AGAIN. SMOKE / ODER REPORT COMPLETED / PERFORMED LEVEL 2 IAW TASK CARD 21-000-002. CHECKS GOOD. THIS CLEARS M313 MDDR 221413. PER TC A32X-21-000-002 M313 REQUIRED TO C/W TC A32X-21-000-003 WITHIN 10 CALENDAR DAYS. TASK CARD 21-000-003 C/W M313 CREATED TO COMPLY WITH TASK CARD 05-000-011 BETWEEN 5 AND 15 CYCLES.

Source: SDR WX0A2025102732611
OTHER · 2025-05-06 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (ZONE 200) · airframe 50,588 hrs · 34,107 cycles

(AIRCRAFT NOT GROUNDED) PER WO 520528 AND TC 335100-03-1-001 MID CABIN SIDEWALL LH EMERGENCY EXIT SIGN LIGHT FOUND TO BE INOP. / REMOVED AND REPLACED LH MID CABIN SIDEWALL EMERGENCY EXIT SIGN LIGHT. OPS CHECK GOOD IAW AMM 33-51-16-400-001-A AND 33-51-16-000-001-A."

Source: SDR WX0A2025050732419

2024

NO WARNING INDICATION · 2024-11-25 Matched by certificate designator
ATA 2565

Part: SLIDE — ABNORMAL (L2 COVER) · airframe 49,641 hrs · 33,529 cycles

(AIRCRAFT NOT GROUNDED) L2 SLIDE COVER OUT TOO FAR / RAR L2 SLIDE IAW AMM 25-62-44-000/400-002-A. OPS CHECK GOOD. NO OTHER DEFECTS NOTED."

Source: SDR WX0A2024112732225
NO TEST · 2024-05-31 Matched by certificate designator
ATA 2560

Part: MEGAPHONE — NO TEST (FWD CABIN) · airframe 48,785 hrs · 33,085 cycles

FWD MEGAPHONE VOICE SPEAKING INOP, SIREN WORKS. / REPLACED FWD MEGAPHONE PER LOPA."

Source: SDR WX0A2024060332060
OTHER · 2024-02-07 Matched by certificate designator
ATA 2560

Part: BATTERY — CORRODED (MEGAPHONE) · airframe 48,253 hrs · 32,799 cycles

FORWARD L1 MEGAPHONE BATTERIES CORRODED CONNECTORS, NEEDS TO BE REPLACED. / REMOVED AND REPLACED FORWARD L1 DOOR MEGAPHONE BATTERIES IAW AMM 25-65-51-920-001-A. OPS CHECK GOOD."

Source: SDR WX0A2024020731957

2022

NO TEST · 2022-12-04 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 46,306 hrs · 31,712 cycles

3 EPSU BATTERIES FAILED CAPACITANCE TEST. / REMOVED AND REPLACED 3 EPSU BATTERIES AND PERFORMED EPSU CAPACITANCE TEST. TEST OK. REFERENCE AMM 33-51-38-400-002-A AND 33-51-00-710-003-A"

Source: SDR WX0A2022120531669
NO WARNING INDICATION · 2022-08-30 Matched by certificate designator
ATA 5341

Part: NONE — NONE

NRC 2000-0082: 429-90 DURING SPECIAL DETAILED INSPECTION OF THE DOOR STOP FITTINGS HOLES AT AFT PASSENGER/CREW DOOR, ONE CRACKED FOUND AT L2 DOOR FR 68 FITTING NO.1 LOWER I/B HOLE./FR 68, DOOR STOP FITTINGS NO.01, LOWER I/B HOLE REPAIRED AS PER SRM 53-41-12-300-011 REV 141 AND SRM 51-73-12 REV.141. FINAL HOLE DIA. FOR CRACK REMOVAL AND BEFORE FREEZE PLUG INSTALLATION IS 0.575 INCH. PERMANENTLY REPAIRED, CATEGORY B.INSPECTION THRESHOLD: 37900 FC (FH NOT RELEVANT), INTERVAL 5600 FC (FH NOT RELEVANT) AS PER SRM 53-41-12-205-010, REV. 141. INSPECTION METHOD: HFEC AS PER NTM 51-10-08 REV.136. SEE AWS AND NDT REPORT MWO52235-30 FOR DETAIL."

Source: SDR WX0A1900010074258
NO WARNING INDICATION · 2022-08-27 Matched by certificate designator
ATA 5320

Part: BEAM — CORRODED (R2 DOOR SILL) · airframe 46,005 hrs · 31,524 cycles

NRC 2000-0025 : 32779-31 AFT PASSENGER CABIN ON R2 DOOR SILL BEAM LOCATED AT FR 68-69 STRG 23RH CORROSION FOUND. / AFT PASSENGER CABIN ON R2 DOOR SILL BEAM LOCATED AT FR 68-69 STRG 23RH CORROSION REMOVED BY BLENDING AS PER SRM 51-74-00 AND FOUND OUT OF LIMITS AS PER SRM 53-41-14-283-002 MATERIAL REMOVED 0.029'' WHICH REPRESENT 40.8% MAXIMUM ALLOWABLE IS 25%. AREA REPAIRED AS PER SRM 53-41-14-300-001 FIG 001 PRINCIPLE 8. REPAIR CATEGORY A NO FURTHER ACTION REQUIRED. SEE AWS FOR REPAIR STEPS AND NDT REPORT MWO 52235-13"

Source: SDR WX0A2022091274239
NO WARNING INDICATION · 2022-05-12 Matched by certificate designator
ATA 3300

Part: EPSU — NONE · airframe 45,495 hrs · 31,250 cycles

DURING OPS CHECK OF EMER LIGHT SYSTEM, EPSU BATTERY (12WL) EMER R FAILED. / REMOVED AND REPLACED EPSU BATTERY (12WL) IAW AMM 33-51-38. OPS CHECK - GOOD"

Source: SDR WX0A2022051374089
NO WARNING INDICATION · 2022-03-14 Matched by certificate designator
ATA 2565

Part: MEGAPHONE — INOPERATIVE · airframe 45,151 hrs · 31,079 cycles

AFT FA MEGAPHONE NOT WORKING / REPLACED AFT MEGAPHONE IAW AMM 25-65-51."

Source: SDR WX0A2022031674031

2021

NO TEST · 2021-06-13 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — NO TEST (EMEGENCY LIGHTS) · airframe 43,580 hrs · 30,244 cycles

FAILED BATTERY CAPACITY CHECK ON 1A1 CHECK / REMOVED AND REPLACED BATTERY (FIN 10WL,FWD LEFT HAND) IAW AMM TASK 33-51-38-002-A, 33-51-38-400-002-A. OPERATIONAL CHECK COMPLETED"

Source: SDR WX0A2021061473739

2020

NO TEST · 2020-07-22 Matched by certificate designator
ATA 3350

Part: EPSU — NO TEST (EMERGENCY LIGHTS) · airframe 41,936 hrs · 29,416 cycles

CABIN EMERGENCY LIGHTING, TEST SHOWS FAULT OF EPSU(13WL)AFT L / T/S PER TSM 33-51-00-810-857-A.CONFIRMED FAULT OF EPSU FIN 13WL. R/R EPSU BATTERY PER AMM 33-51-38. OPS CHK GOOD"

Source: SDR WX0A2020072473531
OTHER · 2020-05-13 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 41,521 hrs · 29,237 cycles

EPSU BATTERY FIN# 12WL FAILED EPSU BAT CAP TEST / REPLACED EPSU BATTERY"

Source: SDR WX0A2020051573504

2019

OTHER · 2019-11-29 Matched by certificate designator
ATA 2560

Part: KNOB — BROKEN (FWD MEGAPHONE) · airframe 40,826 hrs · 28,894 cycles

WHILE PERFORMING EMERGENCY EQUIPMENT CHECK FOUND FWD MEGAPHONE TO HAVE A BROKEN VOLUME KNOB / REMOVED AND REPLACED FWD MEGAPHONE REF AMM 25-65-51 PB 201 OPS CHECK GOOD AT THIS TIME"

Source: SDR WX0A2019120273439
WARNING INDICATION · 2019-10-02 Matched by certificate designator
ATA 2131

Part: CONTROLLER — MALFUNCTIONED (CABIN PRESSURE) · airframe 40,494 hrs · 28,727 cycles

EMERGENCY DECLARED, LOST OF CABIN PRESSURE. R&R R1 & R2 DOOR SEALS, CABIN PRESSURE CONTROLLERS,

Source: SDR WX0A2019100373426
SMOKE/FUMES/ODORS/SPARKS · 2019-04-19 Matched by certificate designator
ATA 2120

Part: ECS — CONTAMINATED (RIGHT)

STRONG DIRTY SOCK SMELL DURING DESCENT. PERFORMED ECS DECONTAMINATION. R&R RIGHT HAND WATER INJECTOR, FLOW CONTROL VALVE, ACM, PRIMARY HEAT EXCHANGER, MAIN HEAT EXCHANGER, REHEATER, CONDENSER, RECIRCULATION FILTER, AND OZONE FILTER.

Source: SDR WX0A2019042273390