N333EN

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

105 reports on file, 2002-09-13 – 2021-08-09.

OTHER · 2021-08-09 Unresolved
ATA 5312

Part: NONE — NONE · airframe 55,642 hrs · 66,677 cycles

NOSE DOOR PIN HOLE IS ELONGATED AND CRACKED AT FSX -7.00, LBL 9.5” MEASURING 1.200”L X 1.00W, DENTS AT BULKHEAD WEB FSX -7.00 LBL 7”-8” DENT #1 MEASURES .800L X .800W X .40D, DENT #2 MEASURES 1.00L X .900W X .015D. CUTOUT WEB P/N: 85310146 DIM L-16.875"X W-9.5", REPLACED WITH P/N: 85310146 DIM L-16.875"X W-9.5" MADE FROM 2024-T3 .025 REF. DE HAVILLAND RD 8-53-17202 REV DATE: 2021-08-26.

Source: SDR 4AER2021083100004
Earlier reports · 2002–2018 · 104 reports

2018

OTHER · 2018-02-05 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT) · airframe 54,977 hrs · 65,860 cycles

LEFT AFT EXTRIOR EMERGENCY LIGHT DIM. R & R THE BULB, OPS CHECKED GOOD.

Source: SDR HNAA2018020700027

2017

SMOKE/FUMES/ODORS/SPARKS · 2017-11-19 Matched by certificate designator
ATA 4900

Part: CONTACTOR — INOPERATIVE (APU) · airframe 54,566 hrs · 65,320 cycles

APU WOULD NOT SHUT OFF. SUSPECTED WELDED APU CONTACTOR. CREW NOTICED EXCESSIVE SMOKE FROM APU AND PULLED THE APU FIRE BOTTLE. R & R THE APU GENERATOR IAW CARD 24-30-02. R & R APU START CONTACTOR IAW STANDARD PRACTICES AND APU GCU IAW AMM 24-49-03 AS PRECAUTION. RAN AND SHUT DOWN APU SEVERAL TIMES WITH NO FAULTS.

Source: SDR HNAA2017112100379
WARNING INDICATION · 2017-09-14 Matched by certificate designator
ATA 3211

Part: BOLT — SHEARED (MLG ACTUATOR MNT) · airframe 54,227 hrs · 64,939 cycles

DURING GEAR RETRACTION RIGHT GEAR UNSAFE LIGHT AND 3 AMBER INDICATIONS. PERFORMED CHECKLIST USING GEAR ALTERNATE EXTENSION. HYD PRESSURE AND QTY ARE NORMAL. INSPECTED THE NR 2 MLG. FOUND MLG RETRACT ACTUATOR FITTING ATTACH BOLTS SHEARED AT MAIN FRAME.

Source: SDR HNAA2017091800312
SMOKE/FUMES/ODORS/SPARKS · 2017-08-23 Matched by certificate designator
ATA 2460

Part: RECEPTACLE — SMOKE (DC POWER) · airframe 54,167 hrs · 64,787 cycles

DC POWER EXTERNAL RECEPTACLE WAS SMOKING WITH GPU CONNECTED. SHUT-DOWN AND DISCONNECTED GPU. FACT: INSPECTED AND FOUND HEAT DAMAGE TO AFT PIN IN EXT.P POWER RECEPTICLE. AIRCRATF SYSTEM OPS NORMAL

Source: SDR HNAA2017082800290
WARNING INDICATION · 2017-01-27 Matched by certificate designator
ATA 2497

Part: CONNECTOR — DIRTY (NR 2 GENERATOR) · airframe 53,037 hrs · 63,267 cycles

NR 2 AC GENERATOR CAUTION LIGHT ILLUMINATED DURING TAXI. CLEANED THE CONNECTOR PLUG. GROUND RAN ACFT, OPS CHECKED GOOD.

Source: SDR HNAA2017012700029
OTHER · 2017-01-11 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHTS) · airframe 52,983 hrs · 63,204 cycles

EMERGENCY LIGHT IS INOPERATIVE AT ROW 5. REMOVED AND REPLACED THE BULB. OPS CHECKED GOOD.

Source: SDR HNAA2017011100013

2016

FALSE WARNING · 2016-12-12 Matched by certificate designator
ATA 2422

Part: WARNING LIGHT — FALSE ACTIVATION (AC BUSS) · airframe 52,835 hrs · 63,012 cycles

RT AC BUSS CAUTION LIGHT ILLUMINATED INFLIGHT ALONG WITH THE ASSOCIATED CAUTION LIGHTS. CYCLED AC GENERATOR SWITCH. GROUND RAN AIRCRAFT C/N/D. AC SYSTEM OPERATES NORMAL. OK FOR SERVICE.

Source: SDR HNAA2016121300390
OTHER · 2016-12-09 Matched by certificate designator
ATA 3060

Part: BRUSH BLOCK — DAMAGED (PROPELLER HEAT) · airframe 52,794 hrs · 62,958 cycles

EMERGENCY LIGHT FLICKERED WITH PROP HEAT ON. RIGHT "A" PHASE. REMOVED AND REPLACED NR 2 PROP BRUSH BLOCK IAW MM 66-10-11. GROUND RAN AND OPS CHECKED GOOD. OK FOR SERVICE.

Source: SDR HNAA2016120900379
SMOKE/FUMES/ODORS/SPARKS · 2016-11-11 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 52,266 hrs · 62,817 cycles

STRONG ELECTRICAL ODOR IN CABIN AT ROWS 1 AND 2. COULD NOT DUPLICATE. GROUND RAN AIRCRAFT. TURNED ON ALL LIGHTS, RAN BLEED AIR, NO ODOR NOTED. OK FOR SERVICE.

Source: SDR HNAA2016111100347
OTHER · 2016-11-11 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN FLOOR) · airframe 52,666 hrs · 62,789 cycles

EMERGENCY LIGHT IS INOPERATIVE AT ROW 1DF. REMOVED AND REPLACED EMERGENCY LIGHT. OPS CHECKED GOOD

Source: SDR HNAA2016111100346
NO TEST · 2016-09-30 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 52,426 hrs · 62,499 cycles

FIRST EMERGENCY FLOOR LIGHT IS INOP. REMOVED AND REPLACED FIRST EMERGENCY LIGHT BULB. OPS CHECKED GOOD.

Source: SDR HNAA2016093000301
OTHER · 2016-09-26 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT) · airframe 52,407 hrs · 62,477 cycles

FLOOR EMERGENCY LIGHT IS OUT AT ROW 3DF. REMOVED AND REPLACED BULB. OPS CHECKED GOOD.

Source: SDR HNAA2016092600293
NO TEST · 2016-09-05 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 52,307 hrs · 62,345 cycles

4TH EMERGENCY FLOOR LIGHT FROM FRONT IS INOPERATIVE. R & R 4TH EMERGENCY FLOOR LIGHT.

Source: SDR HNAA2016090700271
OTHER · 2016-07-19 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT) · airframe 52,060 hrs · 62,012 cycles

RIGHT AFT EMERGENCY EXIT SIGN DIM. R & R THE BULB.

Source: SDR HNAA2016072000224
OTHER · 2016-07-16 Matched by certificate designator
ATA 3350

Part: CABLE — MISSING (EMERGENCY LIGHT) · airframe 52,041 hrs · 61,991 cycles

MISSING ONE EMERGENCY LIGHT IN THE CABIN. INSTALLED EMERGENCY LIGHT CABLE ASSY.

Source: SDR HNAA2016071800221
OTHER · 2016-07-10 Matched by certificate designator
ATA 4920

Part: CONTACTOR — INOPERATIVE (APU) · airframe 520,009 hrs · 61,944 cycles

APU GENERATOR WARNING LIGHT REMAINS ILLUMINATED AFTER APU SHUTDOWN. APU GENERATOR LOAD SHOWS HIGH, SUSPECT WELDED CONTACTOR. R & R APU START CONTACTOR. APU GENERATOR WARNING LIGHT NO LONGER ILLUMINATED. UNABLE TO OPS CHECK DUE TO APU FAILING TO START.

Source: SDR HNAA2016071100211
NO TEST · 2016-05-27 Matched by certificate designator
ATA 3350

Part: LIGHT — DEFECTIVE (CABIN) · airframe 51,990 hrs · 61,922 cycles

7TH FROM LAST EMERGENCY LIGHT IS INOPERATIVE. TROUBLESHOT AND DETERMINED BULB TO BE DEFECTIVE. R & R BULB ON 7TH FROM LAST EMERGENCY FLOOR LIGHT. OPS CHECK GOOD, OK FOR SERVICE.

Source: SDR HNAA2016052700152
NO TEST · 2016-05-12 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 51,906 hrs · 61,818 cycles

EMERGENCY LIGHTS, 4TH RED LIGHT BULB OF FWD MOST SET OF RED FLOOR LIGHTS INOPERATIVE. REMOVED FWD MOST SECTION OF EMERGENCY FLOOR LIGHT COVER. R & R 4TH RED FLOOR LIGHT OF FWD MOST SET OF RED LIGHTS SECURED FLOOR LIGHTS COVER IN TRACK.

Source: SDR HNAA2016051300145
OTHER · 2016-04-04 Matched by certificate designator
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 51,671 hrs · 61,513 cycles

RED EMERGENCY LIGHT AT ROW 13 INOPERATIVE. REPLACED THE LAMP AT ROW 13.

Source: SDR HNAA2016040400097
OTHER · 2016-02-22 Matched by certificate designator
ATA 5410

Part: FITTING — CRACKED (NR 2 NACELLE) · airframe 51,396 hrs · 61,153 cycles

NR 2 ENGINE HOSE COLLAR AFT FLANGE IS CRACKED IN 2 LOCATIONS, BOTH 1" LONG LOCATED 3.5" TO LT OF CENTER BOTH VERTICAL ROWS OF RIVETS. R & R RIVETS AND DAMAGED RADIUS IAW RD8-54-3774.

Source: SDR HNAA2016022200049
OTHER · 2016-01-22 Matched by certificate designator
ATA 3350

Part: BULB — MALFUNCTIONED (EMERGENCY LIGHT) · airframe 51,261 hrs · 60,983 cycles

FORWARD RT EMERGENCY EXIT KNEE LIGHT IS DIM. R & R BULBS. OPS CHECKED GOOD.

Source: SDR HNAA2016012200018

2015

OTHER · 2015-12-25 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT) · airframe 51,103 hrs · 60,769 cycles

EMERGENCY ESCAPE PATH FLOOR LIGHT IS INOPERATIVE AT 7TH FROM FRONT, R & R. OPS CHECKED GOOD.

Source: SDR HNAA2015122500371
FLUID LOSS · 2015-12-01 Matched by certificate designator
ATA 7310

Part: UNKNOWN — LEAKING (NR 1 ENGINE) · airframe 50,971 hrs · 60,599 cycles

NR 1 ENGINE SUSPECTED FUEL LEAK. INSPECTED NR 1 ENGINE FOR FUEL LEAK. GROUND AN AIRCAFT. NO LEAK NOTED AT THIS TIME.

Source: SDR HNAA2015120100354
OTHER · 2015-11-09 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHTS) · airframe 50,835 hrs · 60,416 cycles

FORWARD 2 EMERGENCY ESCAPE PATH FLOOR LIGHTS ARE INOPERATIVE. R & R BULBS FOR FLOOR EMERGENCY ESCAPE PATH LIGHT, OPS CHECKED GOOD.

Source: SDR HNAA2015110900327
OTHER · 2015-11-09 Matched by certificate designator
ATA 3350

Part: BULB — DIM (EMERGENCY LIGHT) · airframe 50,835 hrs · 60,416 cycles

LEFT AFT EMERGENCY EGRESS LIGHT IS DIM. R & R AFT EMERGENCY EGRESS LIGHT, OPS CHECKED GOOD,

Source: SDR HNAA2015110900328
OTHER · 2015-04-27 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT) · airframe 49,670 hrs · 58,844 cycles

FLOOR EXIT SIGN A PASSENGER DOOR AND 1DF ARE INOPERATIVE. R & R BULBS AT PASSENGER DOOR FLOOR EMERGENCY LIGHTS AND ROW 1DF. OPS CHECKED GOOD.

Source: SDR HNAA2015042700142
OTHER · 2015-04-27 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT) · airframe 49,670 hrs · 58,844 cycles

EMERGENCY FLOOR LIGHT IS OUT AT ROW 10DF. R & R BULB. OPS CHECKED GOOD.

Source: SDR HNAA2015042700141
OTHER · 2015-03-09 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT) · airframe 49,355 hrs · 58,438 cycles

EMERGENCY FLOOR PATH LIGHT IS INOP AT ROW 1. R & R BULB AT ROW 1 EMERGENCY FLOOR PATH LIGHT, OPS CHECKED GOOD.

Source: SDR HNAA2015030900082
OTHER · 2015-01-12 Matched by certificate designator
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 49,024 hrs · 58,019 cycles

EMERGENCY LIGHT IS INOPERATIVE. R & R THE LAMP. OPS CHECKED GOOD.

Source: SDR HNAA2015011200016

2014

SMOKE/FUMES/ODORS/SPARKS · 2014-12-17 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 48,857 hrs · 57,798 cycles

STRONG ELECTRICAL ODOR COMING FROM CLOSET. INSPECTED WIRING AND COMPONENTS IN CLOSET UPPER AND LOWER AVIONICS RACKS AND BEHIND PILOT AND F/O. INSPECTED NOSE COMPARTMENT. NO FAULTS FOUND. GROUND RAN AIRCRAFT. ALL SYSTEMS OPERATED NORMAL. OPS CHECKED GOOD. OK FOR SERVICE.

Source: SDR HNAA2014121700367
OTHER · 2014-09-08 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT) · airframe 48,281 hrs · 57,042 cycles

EMERGENCY LIGHT IS INOPERATIVE AT ROW 11. R & R BULB. OPS CHECKED GOOD.

Source: SDR HNAA2014090800261
SMOKE/FUMES/ODORS/SPARKS · 2014-04-10 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (COCKPIT) · airframe 47,330 hrs · 55,781 cycles

STRONG ODOR IN FLIGHT DECK, GROUND RAN ACFT, EXERCISED ACFT AND D/C POWER, NO ABNORMAL ODORS FOUND AT THIS TIME. OK FOR SERVICE.

Source: SDR HNAA2014041000125
OTHER · 2014-03-10 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (EMERGENCY LIGHT) · airframe 47,118 hrs · 55,518 cycles

EMERGENCY LIGHT HAS A WIRE BROKEN. SPLICE WIRES IAW PPS 9.09 (5.7). OPS CHECKED GOOD.

Source: SDR HNAA2014031000082
SMOKE/FUMES/ODORS/SPARKS · 2014-03-05 Matched by certificate designator
ATA 3320

Part: SOCKET — DAMAGED (CABIN LIGHTS) · airframe 47,101 hrs · 55,492 cycles

CABIN OVERHEAD LIGHT AT 8 A/C INTERMITTENT WITH LIGHT ODOR. FOUND LT SOCKET DAMAGED. CABIN OVERHEAD LIGHTS DEACTIVATED CIRCUIT BREAKERS S1, S2 & R2. CABIN INTERIOR NORMAL LIGHTING SYSTEM, SPECIAL PROCEDURE 33.1 HAS BEEN COMPLIED WITH.

Source: SDR HNAA2014030700073

2013

NO TEST · 2013-12-18 Matched by certificate designator
ATA 3350

Part: BULB — FAILED (EMERGENCY LIGHT) · airframe 46,659 hrs · 54,909 cycles

EMERGENCY SIDEWALL LIGHT IS INOPERATIVE AT ROW 11AC. R & R BULB. OPS CHECKED GOOD.

Source: SDR HNAA2013121800620
FALSE WARNING · 2013-10-21 Matched by certificate designator
ATA 3150

Part: INDICATOR — FAILED (TORQUE) · airframe 46,317 hrs · 54,471 cycles

TAKEOFF WARNING HORN SOUNDED AFTER TAKEOFF, 70 PERCENT TORQUE. ACFT CONFIGURED PROPERLY. R & R FAULTY SWITCH. OPS CHECKED GOOD. FAILED ENGINE RUN. R & R NR 1 TORQUE INDICATOR IAW AMM 77-1-5. OPS CHECKED GOOD WITH ENGINES RUNNING.

Source: SDR HNAA2013102100540
OTHER · 2013-10-17 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 593) · corrosion level 2 · airframe 46,313 hrs · 54,468 cycles

FUSELAGE SKIN INNER SIDE FOUND CORRODED UNDER FRAME. BLENDED SKIN ON WAFFLE IAW SRM 51-20-11. COMPLIED WITH HFEC INSPECTION. SKIN REPAIRED IAW EA15-2013-430.

Source: SDR HNAA2013101700537
OTHER · 2013-10-17 Matched by certificate designator
ATA 5311

Part: FRAME — CRACKED · airframe 46,313 hrs · 54,468 cycles

FLIGHT COMPARTMENT FRAME BRACKET IS CRACKED BETWEEN LOWER PILOTS WINDOW AND SIDE WINDOW. R & R FRAME BRACKET BETWEEN LOWER SIDE WINDOW AND PILOTS WINDSHIELD WITH NEW PARTS AND INSTALLED WITH SOLID RIVETS IAW SRM 51-42-05 AND HI-LOKS IAW SRM 51-40-10.

Source: SDR HNAA2013101700536
OTHER · 2013-10-17 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (BS 582) · corrosion level 3 · airframe 46,313 hrs · 54,468 cycles

STRINGER 31S FOUND CORRODED. R & R WITH NEW IAW RD8-53-1312, RD8-51-015 AND SRM 51-42-05.

Source: SDR HNAA2013101700538
SMOKE/FUMES/ODORS/SPARKS · 2013-09-03 Matched by certificate designator
ATA 2120

Part: BALLAST — BURNED (CABIN LIGHTS) · airframe 46,184 hrs · 54,302 cycles

F/A REPORTS MILD ELECTRICAL ODOR IN CABIN OVERHEAD LIGHTS. DEACTIVATED BY PULLING AND COLLARED C/B SI,S2,R2 IAW S.P.33.1. R & R BULB HOLDER AND BALLAST ASSY IAW MM 20-45-07. OPS CHECKED GOOD. PERFORMED HIDDEN DAMAGE INSPECTION. NO DEFECTS NOTED IN SURROUNDING AREA AT THIS TIME.

Source: SDR HNAA2013090300486
FLUID LOSS; WARNING INDICATION · 2013-07-01 Matched by certificate designator
ATA 2910

Part: LINE — LEAKING (HYD SYSTEM) · airframe 45,759 hrs · 53,749 cycles

NR 2 HYD QTY DROPPED TO .5 QUARTS FOLLOWED BY ISO VALVE CAUTION LIGHT. R & R DRAG STRUT ACTUATOR STARBOARD FLEX LINE. CLEANED AREA, SERVICED HYD, GROUND RAN ACFT. OPS AND LEAKED CHECKED GOOD.

Source: SDR HNAA2013070100379
OTHER · 2013-06-26 Matched by certificate designator
ATA 3350

Part: SWITCH — FAILED (EMERGENCY LIGHTS) · airframe 45,724 hrs · 53,700 cycles

EMERGENCY LIGHTS WILL NOT TURN OFF. R & R F/A EMERGENCY LIGHT SWITCH. OPS CHECKED GOOD IAW WC 33-50-03Q.

Source: SDR HNAA2013062600365
NO TEST · 2013-03-26 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT) · airframe 45,135 hrs · 52,922 cycles

FORWARD RT TOP, LT AFT AND RT MOST AFT TOP EMERGENCY SIGNS ARE DIM. R & R BULBS IN EMERGENCY EXIT SIGNS. OPS CHECKED GOOD. RESECURED LENS.

Source: SDR HNAA2013032600184
WARNING INDICATION · 2013-03-04 Matched by certificate designator
ATA 2421

Part: GCU — FAILED · airframe 44,984 hrs · 52,730 cycles

ACFT OUT OF POSITION DUE TO RT AC BUSS AND TRU CAUTION LIGHTS. MX REPLACED AC GCU AND AC GEN SWITCH. GROUND RAN ACFT. OPS CHECKED GOOD.

Source: SDR HNAA2013030400102
NO TEST · 2013-02-01 Matched by certificate designator
ATA 3397

Part: WIRE — DISCONNECTED (EMERGENCY LIGHT) · airframe 44,797 hrs · 52,495 cycles

CEILING EMERGENCY LIGHT AT ROW 10AC IS INOP. PARTIALLY LOWERED HEADLINER AT ROW 10AC. FOUND WIRE DISCONNECTED. RECONNECTED WIRE TO LIGHT AT 3351/P23. RESECURED HEADLINER AT ROW 10 AC. OPS CHECKED GOOD.

Source: SDR HNAA2013020100031
SMOKE/FUMES/ODORS/SPARKS · 2013-01-28 Matched by certificate designator
ATA 3320

Part: SOCKET — BURNED (CABIN LIGHTS) · airframe 44,753 hrs · 52,449 cycles

STRONG ELECTRICAL ODOR COMING FROM AROUND ROW 6. INSPECTED AND FOUND DAMAGED OVERHEAD LIGHT SOCKET AT ROW 8 AND 9DF. R & R SOCKET ASSY AT ROW 8 AND 9DF. OPS CHECKED GOOD.

Source: SDR HNAA2013012800022

2012

SMOKE/FUMES/ODORS/SPARKS · 2012-08-11 Matched by certificate designator
ATA 3320

Part: FIXTURE — BURNED (CABIN LIGHTS) · airframe 43,815 hrs · 51,226 cycles

CABIN O/H LIGHT AT 6D/F FWD FIXTURE END SMOKING. MX INSPECTED AND FOUND FWD END BURNED AND PULLED AND COLLARD CIRCUIT BREAKERS S1, S2, AND R2 PER SP 33.1.

Source: SDR HNAA2012081300916
NO TEST · 2012-08-01 Matched by certificate designator
ATA 3350

Part: BULB — FAILED (EMERGENCY LIGHT) · airframe 43,743 hrs · 51,130 cycles

ROW 7 CEILING EMERGENCY LIGHT IS INOPERATIVE. REMOVED LENS, R & R BULB, AT SAID LOCATION. REINSTALLED LENS. OPS CHEKCED GOOD.

Source: SDR HNAA2012080100888
OTHER · 2012-07-18 Matched by certificate designator
ATA 3350

Part: SIGN — DISLODGED (CABIN) · airframe 43,641 hrs · 50,998 cycles

EMERGENCY EXIT SIGN ABOVE AIRSTAIR FALLING OFF. RESECURED. OK FOR SERVICE.

Source: SDR HNAA2012071800869
NO TEST · 2012-04-20 Matched by certificate designator
ATA 3350

Part: BULB — BURNED OUT (EMERGENCY LIGHT) · airframe 43,060 hrs · 50,232 cycles

FLOOR PATH EMERGENCY LIGHT IS INOPERATIVE AT ROW 7. R & R BULB. OPS CHECKED GOOD.

Source: SDR HNAA2012042000742
FLUID LOSS; WARNING INDICATION · 2012-03-19 Matched by certificate designator
ATA 2910

Part: LINE — LEAKING (HYD SYSTEM) · airframe 42,845 hrs · 49,955 cycles

LOST HYD NR 2 SYS ISOLATION VALVE, CAUTION LIGHT ILLUMINATED, HAD TO PERFORM ALTERNATE EXTENSION OF GEAR. HYD PRESSURE APPEARED NORMAL. INSPECTED AND FOUND NR 2 QTY AT 1 QT. INSTALLED TEMP FLEX LINE FROM RESERVOIR TO TEE FITTING. OPS AND LEAKED CHECKED GOOD.

Source: SDR HNAA2012031900702
FALSE WARNING · 2012-02-20 Matched by certificate designator
ATA 2611

Part: SMOKE DETECTOR — MALFUNCTIONED (CARGO BAY) · airframe 42,670 hrs · 49,745 cycles

CARGO SMOKE WARNING LIGHT ILLUMINATED DURING TAXI OUT. R & R BOTH FWD AND AFT BAG BAY SMOKE DETECTORS IAW AMM 26-12-01. OPS CHECKED IAW 26-12-00, OPS CHECKED GOOD.

Source: SDR HNAA2012022100598

2011

WARNING INDICATION · 2011-12-09 Matched by certificate designator
ATA 2130

Part: UNKNOWN — UNKNOWN (CABIN PRESSURE) · airframe 42,184 hrs · 49,156 cycles

WITH EITHER BLEED SELECTED ON, ACFT PRESSURIZED AND CABIN HEATS UP. VERFIED BOTH REAR OUTFLOW VALVES OPEN. GROUND RAN ACFT AND OPERATED NR 2 BLEED AND BOTH PACKS CHECKED GOOD, OK FOR SERVICE.

Source: SDR HNAA2011120900419
NO TEST · 2011-04-28 Matched by certificate designator
ATA 3350

Part: SIGN — FAILED (CABIN) · airframe 40,796 hrs · 47,323 cycles

FWD EMERGENCY SIGN FAILED BETA LIGHT FUNCTION CHECK. R & R EMERGENCY SELF POWERED LIGHT.

Source: SDR HNAA2011050600106
NO TEST · 2011-04-28 Matched by certificate designator
ATA 3350

Part: LIGHT — FAILED (CABIN) · airframe 40,296 hrs · 47,323 cycles

AFT RT EMERGENCY EXIT SIGN FAILED BETA LIGHT FUNCTION CHECK. R & R AFT RT EMERGENCY SELF POWERED LIGHT AND LENS.

Source: SDR HNAA2011050600105
OTHER · 2011-04-28 Matched by certificate designator
ATA 3350

Part: LIGHT — FAILED (CABIN) · airframe 40,796 hrs · 47,323 cycles

AFT LT EMERGENCY EXIT SIGN FAILED BETA LIGHT FUNCION CHECK. R & R EMERGENCY SELF POWERED LIGHT AND LENS.

Source: SDR HNAA2011050600103
OTHER · 2011-04-20 Matched by certificate designator
ATA 5311

Part: FRAME — CRACKED (BS 128.1 S25-26R) · airframe 40,794 hrs · 47,320 cycles

FRAME STA 128.1 CRACKED BETWEEN STRINGER 25R AND 26R. REPAIRED FRAME STATION 128.1 BETWEEN STRINGER 25R AND 26R IAW -8300 SRM 53-20-21, PAGE 2.

Source: SDR HNAA2011050600113
OTHER · 2011-04-15 Matched by certificate designator
ATA 5310

Part: PANEL — CRACKED (COCKPIT) · airframe 40,794 hrs · 47,320 cycles

COCKPIT ENTRANCE FLOOR CLOSE OUT PANEL CRACKED. REMOVED AND FABRACATED COCKPIT ENTRANCE CLOSE OUT PANEL IAW DWG 85311097. INSTALLED PANEL IAW -8300 SRM 51-40-11. PART MAKE OF 2024T3 .040, BATCH 37.

Source: SDR HNAA2011050600111
OTHER · 2011-04-08 Matched by certificate designator
ATA 5330

Part: ACCESS PANEL — CORRODED (FUSELAGE) · airframe 40,794 hrs · 47,320 cycles

CORROSION INSIDE PANEL 132AR. CORRODED PANEL REMOVED, NEW DOOR PANEL INSTALLED AS REQUIRED. ALL WORK DONE IAW SRM 51-40-07, 51-40-11. FINISH PAINT AS REQUIRED ON EXTERIOR SURFACE OF DOOR PANEL.

Source: SDR HNAA2011050600115
OTHER · 2011-04-08 Matched by certificate designator
ATA 5320

Part: SILL — CORRODED (FUSELAGE) · airframe 40,794 hrs · 47,320 cycles

SERVICE DOOR SILL HAS CORROSION AROUND NUTPLATE. REMOVED CORROSION FROM SERVICE DOOR SILL AROUND NUTPLATE HOLE IAW SRM 51-20-00. FOUND TO BE WITHIN LIMITS. ALODINE, PRIMED AND REPAINTED SERVICE DOOR SILL.

Source: SDR HNAA2011050600114
OTHER · 2011-04-06 Matched by certificate designator
ATA 5753

Part: SHAFT — CORRODED (FLAP CARRIAGE) · airframe 40,794 hrs · 47,320 cycles

RT NR 4 FLAP CARRIAGE HAS 3 WORN AND CORRODED MAIN ROLLER SHAFTS. R & R RT NR 4 FLAP CARRIAGE MAIN ROLLER SHAFT IAW -8300 AMM 57-50-43.

Source: SDR HNAA2011050600118
OTHER · 2011-04-06 Matched by certificate designator
ATA 3010

Part: CLAMP — CORRODED (DE ICE SYSTEM) · airframe 40,794 hrs · 47,320 cycles

ADEL CLAMP ON RT L/E DEICE LINE BETWEEN YW106.800 AND RT NACELLE IS CORRODED. R & R ADELL CLAMP ON RT L/E DEICE LINE BETWEEN YW106-800 AND RT HAND NACELLE.

Source: SDR HNAA11050600116A
OTHER · 2011-04-06 Matched by certificate designator
ATA 5754

Part: SHAFT — CORRODED (NR 5 SLAT) · airframe 40,794 hrs · 47,320 cycles

LEFT NR 5 FLAP CARRIAGE FWD AND AFT OTBD MAIN ROLLER SHAFT WORN AND CORRODED. R & R LT NR 5 FLAP CARRIAGE FWD AND AFT OTBD MAIN ROLLER SHAFT IAW -8300 AMM57-50-53.

Source: SDR HNAA2011050600121
OTHER · 2011-04-06 Matched by certificate designator
ATA 5754

Part: BUSHING — CORRODED (ROLLER SHAFT) · airframe 40,794 hrs · 47,320 cycles

RT NR 5 FLAP CARRIAGE UPPER DEAD WEIGHT ROLLER SHAFT BUSHING CORRODED. R & R RT NR 5 FLAP CARRIAGE DEAD WEIGHT ROLLER SHAFT BUSHING IAW -8300 AMM57-50-53.

Source: SDR HNAA2011050600120
OTHER · 2011-04-06 Matched by certificate designator
ATA 5754

Part: BOLT — CORRODED (FLAP CARRIAGE) · airframe 40,794 hrs · 47,380 cycles

RT NR 4 FLAP CARRIAGE HOOK ROLLER GUARD BOLT IS CORRODED. R & R NR 4 RT FLAP CARRIAGE HOOK ROLLER GUARD BOLT IAW -8300 AMM 57-50-43.

Source: SDR HNAA2011050600119
OTHER · 2011-04-06 Matched by certificate designator
ATA 5755

Part: STRUCTURE — CORRODED (SPOILER) · airframe 40,794 hrs · 47,320 cycles

HARDWARE FOR FLIGHT SPOILER POSITION INDICATOR LT OTBD SPOILER IS CORRODED. R & R HARDWARE ON LT OTBD FLGHT SPOILER POSITION INDICATOR.

Source: SDR HNAA2011050600128
OTHER · 2011-04-06 Matched by certificate designator
ATA 3040

Part: STRUCTURE — RUSTED (WINDSHIELD WIPER) · airframe 40,794 hrs · 47,320 cycles

CO-PILOTS WINDSHIELD WIPER HARDWARE RUSTED. R & R RUSTED HARDWARE AT CO-PILOTS WINDSHIELD WIPER IAW AMM30-42-00.

Source: SDR HNAA2011050600127
OTHER · 2011-04-06 Matched by certificate designator
ATA 5753

Part: SHAFT — CORRODED (TE FLAP CARRIAGE) · airframe 40,794 hrs · 47,320 cycles

LT NR 4 FLAP CARRIAGE HAS 3 MAIN ROLLER SHAFTS THAT ARE WORN AND CORRODED. R & R LT NR 4 FLAP CARRIAGE MAIN SHAFTS ISW -8300 AMM57-52-00.

Source: SDR HNAA2011050600116
OTHER · 2011-04-06 Matched by certificate designator
ATA 5321

Part: FLOORBOARD — CORRODED (GALLEY) · airframe 40,794 hrs · 47,320 cycles

AFT GALLEY FLOORBOARD HARDWARE CORRODED. R & R AFT GALLEY FLOORBOARD HARDWARE.

Source: SDR HNAA2011050600129
OTHER · 2011-04-06 Matched by certificate designator
ATA 5753

Part: BOLT — CORRODED (FLAP CARRIAGE) · airframe 40,794 hrs · 47,320 cycles

LT NR 4 FLAP CARRIAGE GUARD BOLT IS CORRODED. R & R LT NR4 FLAP CARRIAGE GUARD BOLT IAW -8300 AMM 57-50-43.

Source: SDR HNAA20110506117
OTHER · 2011-04-06 Matched by certificate designator
ATA 5740

Part: CLAMP — CORRODED · airframe 40,794 hrs · 47,320 cycles

2 ADEL CLAMPS ON LT L/E DEICE LINE BETWEEN FUSELAGE AND NACELLE ARE CORRODED. R & R 2 ADEL CLAMPS,

Source: SDR HNAA2011050600125
OTHER · 2011-04-04 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (CABIN) · airframe 40,794 hrs · 47,320 cycles

RT INBD SEAT RAIL HAS GOUGES, NICKS AND CORROSION. RT INBD SEAT TRACK REWORKED AND CORROSION REMOVED AS REQUIRED. SEAT TRACK REMAINING IS BEYOND LIMITS IAW RD8-53-784 AND RD8-53-4936. R & R ORIGINAL SEAT TRACK AND INSTALLED NEW SEAT TRACK IAW SRM 51-40-07, 51-40-10, AND 51-42-05.

Source: SDR HNAA20110506112
OTHER · 2011-01-22 Matched by certificate designator
ATA 3350

Part: BULB — BURNED OUT (EMERGENCY LIGHT) · airframe 40,380 hrs · 46,777 cycles

EMERGENCY FLOOR LIGHT AT ROW 10DF INOP. R & R BULB IN EMERGENCY FLOOR LIGHT AT ROW 10DF, OPS CHECKED GOOD.

Source: SDR HNAA2011021500007

2010

NO TEST · 2010-11-22 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (ROW 6) · airframe 40,007 hrs · 46,293 cycles

EMERGENCY FLOOR PATH LIGHT AT ROW 6 IS INOP. R & R ROW 6 EMERGENCY FLOOR PATH LIGHT. OPS CHECKED GOOD.

Source: SDR HNAA2010120300258
OTHER · 2010-08-25 Matched by certificate designator
ATA 5540

Part: STRUCTURE — DAMAGED (RUDDER) · airframe 39,461 hrs · 45,576 cycles

FORE RUDDER ON LT TOP SIDE HAS AN AREA OF IMPACT DAMAGE. REPAIRED IAW EO8-55-10-0379.

Source: SDR HNAA2010082600201
OTHER · 2010-07-24 Matched by certificate designator
ATA 3350

Part: LIGHT — OUT OF POSITION (CABIN) · airframe 39,308 hrs · 45,394 cycles

EMERGENCY EGRESS LIGHT IN ROW 8. REPOSITIONED LIGHT ASSY INTO MODULE. OPS CHECK GOOD.

Source: SDR HNAA2010082600193
OTHER · 2010-05-14 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT) · airframe 38,784 hrs · 44,762 cycles

RT EMERGENCY EXIT LOWER SIDEWALL LIGHT BULB IS INOP. R & R RT AFT EMERGENCY EXIT LOWER SIDEWALL LIGHT BULBS AS REQUIRED.

Source: SDR HNAA2010051400142
SMOKE/FUMES/ODORS/SPARKS · 2010-04-24 Matched by certificate designator
ATA 3320

Part: SWITCH — SPARKS (AIRSTAIR LIGHT) · airframe 38,665 hrs · 44,604 cycles

AIR STAIR DOOR LIGHT SWITCH SPARKS WHEN PRESSED. R & R AIR STAIR DOOR SWITCH AND TESTED IAW MM 33-20-00. RESET CIRCUIT BREAKER, SYS TESTED WELL.

Source: SDR HNAA2010042400127
NO TEST · 2010-01-08 Matched by certificate designator
ATA 3350

Part: BULB — BURNED OUT (EMERGENCY LIGHTS) · airframe 38,010 hrs · 43,797 cycles

DURING RON INSP, A FLOOR EMERGENCY LIGHT WAS FOUND INOPERATIVE. THE BULB WAS REMOVED AND REPLACE AND THE OPS CHECK WAS GOOD.

Source: SDR HNAA20101000001
OTHER · 2010-01-08 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT) · airframe 380,010 hrs · 43,797 cycles

LT EMERGENCY LIGHT IS INOPERATIVE. R & R LT FWD EMERGENCY LIGHT BULB, OPS CKD GOOD.

Source: SDR HNAA2010012200006
WARNING INDICATION · 2010-01-03 Matched by certificate designator
ATA 6100

Part: BETA SWITCH — FAILED (NR 2 ENGINE) · airframe 37,977 hrs · 43,756 cycles

NR 2 ENG TORQUE SURGED APPROX 30 PERCENT RANGE JUST AFTER TAKEOFF. AFTER TAKEOFF NR 2 ENGINE TORQUE SURGED TO APPROX 119 PERCENT AND PROP SURGED TO APPROX 1000 RPM. ACFT AT 100 AGL AND CLEARED UP AFTER LANDING. REACTIVATED BETA LOCKOUT SYS. R & R NR 2 ENG BETA SWITCH IAW STANDARD PRACTICE. PERFORMED BETA LOGIC, OPERATES CKD GOOD. CLEAR MEL.

Source: SDR HNAA2010012200009

2009

SMOKE/FUMES/ODORS/SPARKS · 2009-08-09 Matched by certificate designator
ATA 2210

Part: PANEL — MALFUNCTIONED (COCKPIT) · airframe 37,099 hrs · 42,631 cycles

PILOT REPORTED A BURNING SMELL IN COCKPIT, STATED THAT IT WAS POSSIBLY COMING FROM THE CAPT 802 PANEL. MAINTENANCE REMOVED AND REPLACED 802 ADVISORY PANEL, INSPECTED, AND DRIED OUT AREA. OPERATIONAL CHECK WAS GOOD IAW DASH-8 MM 22-10-09.

Source: SDR HNAA2009081000024
NO TEST · 2009-06-26 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 36,805 hrs · 42,269 cycles

UPON INSPECTION AT SBY, AIRCRAFT N333EN WAS FOUND TO HAVE AN EMERGENCY LIGHT INOPERATIVE. THE EMERGENCY LIGHT BULB WAS REPLACED AND THE OPERATIONAL CHECK WAS GOOD.

Source: SDR HNAA2009062700205
NO TEST · 2009-06-24 Matched by certificate designator
ATA 3350

Part: BULB — BURNED OUT (EMERGENCY LIGHT) · airframe 36,790 hrs · 42,253 cycles

UPON INSP, IT WAS FOUND THAT AN EMERGENCY LIGHT WAS INOPERATIVE. LIGHT BULB WAS REPLACED AND THE OPS CHECK WAS GOOD.

Source: SDR HNAA2009062500199
NO TEST · 2009-06-21 Matched by certificate designator
ATA 3350

Part: BULB — BURNED OUT (EMERGENCY LIGHTS) · airframe 33,767 hrs · 42,225 cycles

UPON INSP, IT WAS FOUND THAT AN EMERGENCY LIGHT WAS INOPERATIVE. THE BULB ON THE EMERGENCY LIGHT WAS REMOVED AND REPLACED. OPS CHECK GOOD.

Source: SDR HNAA2009062400198
OTHER · 2009-01-14 Matched by certificate designator
ATA 3425

Part: AHRS — FAILED (NR 1)

IN FLIGHT CAPTAIN AUTOMATIC DIRECTION INDICATOR PITCH UP ALONG WITH ATTITUDE HEADING AND REFERENCE SYSTEM DATA INVALID MSG ON 802 PANEL ALSO CAPTAIN HORIZONTAL SITUATION INDICATOR AND FIRST OFFICER RADIO MAGNETIC INDICATOR DISPLAYED ERRONEOUS INFORMATION. R&R NR 1 ATTITUDE HEADING AND REFERENCE SYSTEM IAW 34-21-01 OPS CHECK GOOD.

Source: SDR HNAA2009012000000

2008

WARNING INDICATION · 2008-11-21 Matched by certificate designator
ATA 7310

Part: FILTER ELEMENT — CLOGGED (NR 2 ENGINE) · airframe 35,516 hrs · 40,658 cycles

ON TAKEOFF ROLL NR 2 FUEL FILTER BYPASS CAUTION LIGHT ILLUMINATED. ABORTED TAKEOFF. REMOVED, INSPECTED & REPLACED HP & LP FUEL FILTER REF (WORK) CARD 73-10-02R AND 73-10-04R AND MAINT MANUAL 72-00-01 AND REPLACED HP FILTER BYPASS SWITCH REF P&W MAINT, RUNUP CHECKS GOOD.

Source: SDR HNAA2008120200327
PARTIAL RPM/PWR LOSS · 2008-09-07 Matched by certificate designator
ATA 6120

Part: SWITCH — DEFECTIVE (COCKPIT)

AT AN ALTITUDE OF APPROXIMATELY 100 FEET AND AFTER THE LANDING GEAR WAS SELECTED UP, THE NR 1 ENGINE BETA LOCKOUT FAILED. PROP SPEED DROPPED TO 990 RPM AND FLUCTUATED UP TO 1080 RPM. THE EMERGENCY CHECKLIST WAS PERFORMED AND THE ACFT WAS RETURNED TO THE ORIGINATING FIELD. AN EMERGENCY WAS NOT DECLARED. WHILE TRYING TO DEACTIVATE THE BETA SYSTEM, THE PROP WOULD STILL CYCLE IN AND OUT OF BETA RANGE. MX TROUBLESHOOTING DISCOVERED THE POWER LEVER MICRO-SWITCH 6141-S3 TO BE DEFECTIVE. THE SWITCH WAS CHANGED AND SYSTEM RE-ACTIVATED. THE SYSTEM WAS THEN OPS CHECKED WITH APPLICABLE WORKCARD AND CHECKED GOOD. ACFT WAS THEN RELEASED FOR SERVICE.

Source: SDR HNAA0800276
OTHER · 2008-06-29 Matched by certificate designator
ATA 5610

Part: WINDSCREEN — CRACKED (COCKPIT)

F/O WINDSCREEN DEVELOPED CRACKS AFTER DEPARTURE. REMOVED AND REPLACED F/O WINDSCREEN. (K)

Source: SDR HNA2008F00019
SMOKE/FUMES/ODORS/SPARKS · 2008-06-18 Matched by certificate designator
ATA 2530

Part: COFFEEMAKER — BURNED (GALLEY)

HOT JUG IN WARMER NR 1 HAS BURNING SMELL. REPLACED HOT JUG. FOUND ONE BURNED PIN IN OLD JUG. (K)-

Source: SDR HNA2008F00024
NO TEST · 2008-06-15 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (EMERGENCY LIGHT)

ROW 11AC EMERGENCY EXIT SIGN INOP. REPAIRED BROKEN GROUND WIRE AS REQUIRED, OPS CHECK GOOD. (A)

Source: SDR HNAA0800209
OTHER · 2008-05-08 Matched by certificate designator
ATA 7120

Part: MOUNT — BROKEN (NR 1 ENGINE) · airframe 34,530 hrs · 39,388 cycles

NR 1 ENGINE AFT OUTBOARD STRUT MOUNT FOUND TO BROKEN. INSP GENERATED BY INSPECTION CARD 71-20-03.

Source: SDR HNAA0800155
FLT CONT AFFECTED · 2008-04-22 Matched by certificate designator
ATA 2731

Part: SERVO — MALFUNCTIONED (ELEVATOR) · airframe 34,431 hrs · 39,268 cycles

ELEVATOR TRIM IS DIFFICULT TO MOVE AND TRAVEL IS LIMITED. REMOVED AND REPLACED ELEVATOR TRIM SERVO. OPS CHECK GOOD IAW -8 MM.

Source: SDR HNAA0800141
ENGINE STOPPAGE · 2008-03-23 Matched by certificate designator
ATA 7200

Part: ENGINE — MAKING METAL (NR 1) · airframe 34,244 hrs · 39,035 cycles

NR 1 ENGINE FAILED INFLIGHT. CREW WAS FLYING ALONG AT 9000 FT ABOUT 5 MILES WEST OF CLT WHEN NR 1 ENGINE SHUT ITSELF DOWN. THE CREW FEATHERED THE ENGINE AND DECLARED AN EMERGENCY, AND LANDED WITHOUT INCIDENT. MAINTENANCE PULLED THE FDR AND WILL SHIP TO ROA. MAINTENANCE INSPECTED THE ENGINE, PULLED THE STARTER AND SPUN THE ENGINE BY HAND AND THE ENGINE WAS MAKING NOISE. MAINTENANCE THEN PULLED NL PROBE AND FOUND THE NL PROBE PACKED WITH METAL. MORE INFORMATION TO FOLLOW.

Source: SDR HNAA0800108
SMOKE/FUMES/ODORS/SPARKS · 2008-01-27 Matched by certificate designator
ATA 2424

Part: GCU — HOT (NR 2 ENGINE) · airframe 33,878 hrs · 38,582 cycles

AN "ELECTRICAL SMELL" IN FLIGHT DECK ON F/O SIDE, FOUND NR 2 ENG GCU HOT. REPLACED GCU, OPS CHECK GOOD, "ELECTRICAL SMELL GONE", HIDDEN DAMAGE INSP C/W.

Source: SDR HNAA0800050

2007

SMOKE/FUMES/ODORS/SPARKS · 2007-11-14 Matched by certificate designator
ATA 2510

Part: MASTER CAUTION — UNKNOWN (COCKPIT) · airframe 33,405 hrs · 38,023 cycles

DURING CREW SWAP IN CLT, ARRIVING CREW FOUND A FISH ODOR IN COCKPIT AREA. MAINTENANCE CHECKED OVERHEAD PANELS IN COCKPIT. SLIGHT ODOR WAS NOTICED COMING FROM MASTER CAUTION PANEL. REMOVED AND REPLACED CAUTION PANEL AND OPS CHECKED GOOD PER AMM 33-12-01. SMELL DISSIPATED AFTERWARDS AND AIRCRAFT WAS RELEASED FOR SERVICE.

Source: SDR HNAA0700269
FALSE WARNING · 2007-09-03 Matched by certificate designator
ATA 3260

Part: WARNING SYSTEM — MALFUNCTIONED (COCKPIT) · airframe 32,934 hrs · 37,445 cycles

AFTER TAKEOFF CYCLED GEAR UP, LEFT MAIN GEAR DOOR AMBER LIGHT ILLUMINATED (DOORS REMAINED OPEN). LANDING GEAR INOP CAUTION LIGHT ILLUMINATED, PERFORMED ALT EXTENSION PROCEDURES. INSPECTED LT MAIN GEAR PROX SENSORS FOR DEFECTS AND PROPER GAPS, GEAR AND GEAR DOOR SENSORS CHECK GOOD IAW MM 32-10-00. JACKED A/C, SWUNG GEAR SEVERAL TIMES, NO DEFECTS NOTED. REMOVED AND REPLACED PSEU AS PRECAUTIONARY, OPS CHECK GOOD.

Source: SDR HNAA0700174
OTHER · 2007-07-26 Matched by certificate designator
ATA 2565

Part: DISK — BURST (DITCHING DAM) · airframe 32,678 hrs · 37,133 cycles

LEFT DITCHING DAM PRESSURE READS ZERO PSI. FOUND DISK BURST BUT DITCHING DAM DID NOT DEPLOY. REMOVED AND REPLACED DITCHING DAM DISK, BOTTLE AND BAG PER W/C 25-60-10R AND W/C 25-60-07R PARTS REPLACED - BURST DISK ADAPTER P/N A 68641, NITRO CLYLINDER P/N 410870-3, S/N 450, DITCHING DAM P/N 4MAN25-10, S/N F2548.

Source: SDR HNAA0700164
OTHER · 2007-06-15 Matched by certificate designator
ATA 3222

Part: CYLINDER — CORRODED (NLG) · airframe 32,398 hrs · 36,792 cycles

NLG INNER CYLINDER LOWER BORE CORRODED. REMOVED AND REPLACED NLG INNER CYLINDER WITH NEW BEARING AND THRUST SET 8821-1 IAW CMM 32-20-01 NLG STRUT S/N DCL291/90.

Source: SDR HNAA0700117
WARNING INDICATION; ELECT. POWER LOSS-50 PC · 2007-04-15 Matched by certificate designator
ATA 2434

Part: GENERATOR — LIGHTNING STRIKE (LT & RT) · airframe 31,998 hrs · 36,301 cycles

LIGHTNING STRIKE DURING CLIMB & LOST BOTH DC GENS. C/W LIGHTNING STRIKE INSP W/C. NO DEFECTS NOTED AT THIS TIME. STARTER/GEN P/N: 23088-008, S/N-POS 1:788, POS 2:1159. NO GENERATOR CHANGED.

Source: SDR HNAA0700069

2005

FALSE WARNING · 2005-05-26 Matched by certificate designator
ATA 7931

Part: TRANSMITTER — FALSE INDICATION (ENG OIL PRESSURE) · airframe 27,711 hrs · 30,917 cycles

NR 2 ENGINE OIL PRESSURE WENT TO ZERO PSI AND THEN WENT TO 40 PSI WITH NO OIL PRESSURE LIGHT AFTER TAKEOFF. REMOVED AND REPLACED THE NR 2 ENGINE OIL PRESSURE TRANSMITTER.

Source: SDR HNAA0500046

2004

OTHER · 2004-10-19 Matched by certificate designator
ATA 2565

Part: BOTTLE — LEAKING (SLIDE/RAFT) · airframe 26,736 hrs · 29,687 cycles

DURING LAYOVER DITCHING DAM RT EMERGENCY EXIT DOOR WATER DAM WAS ACTIVATED BUT DID NOT DEPLOY. DURING LAYOVER F/A ATTEMPTED TO OPEN EXIT DOOR TO VENT A/C. F/A HERD A HISSING NOISE AND STOPPED REMOVING DOOR. FOUND HISSING NOISE TO BE NITROGEN FROM DITCHING DAM BOTTLE. SERVICED BOTTLE, OPS CHECKED DITCHING DAM SYSTEM NO DISCREPANCY NOTED AND THEN SERVICED AND REACTIVATED SYSTEM.

Source: SDR HNAA0400155

2003

WARNING INDICATION · 2003-01-17 Matched by certificate designator
ATA 6100

Part: PROPELLER (#1 PROP) · airframe 22,747 hrs · 24,647 cycles

NUMBER 1 PROPELLER DUE TO POSSIBLE OVR TORQUE CONDITION. REMOVED AND INSPECTED PROP AND REINSTALLED.

Source: SDR HNAA0300001

2002

OTHER · 2002-09-13 Matched by certificate designator
ATA 2560

Part: BOTTLE — LEAKING (CABIN) · airframe 22,004 hrs · 23,673 cycles

RIGHT HAND DITCHING DAM PREESURE AT 1200 PSI. DITCHING DAM REMOVED AND PUR IN BAG BIN. REPLACED DITCHING DAM NITROGEN BOTTLE AND REINSTALLED DITCHING DAM.

Source: SDR HNAA0200065