N335AS

EMBRAER S A EMB-505 · Fixed-wing multi-engine · 2 engines · 9 seats · Valid Registration

Registered owner: EXECUTIVE AIRSHARE LLC, KS (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
Executive Flight Services, LLC (E07A)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

12 reports on file, 2013-09-10 – 2021-04-01.

WARNING INDICATION · 2021-04-01 Matched by certificate designator
ATA 7500

Part: SHUTOFF VALVE — FAILED (NR 2 BLEED) · airframe 5,895 hrs · 3,905 cycles

BLEED 2 OVERPRESSURE FOLLOWED BY A BLEED 2 FAIL

Source: SDR XMXR202104230004
WARNING INDICATION · 2021-02-21 Matched by certificate designator
ATA 2435

Part: STARTER GEN — FAILED (NR 1) · airframe 5,806 hrs · 3,856 cycles

AFTER START; GEN 1 OFF BUS. POWERED DOWN RESTARTED AND RECEIVED ENGINE 1 CTRL FAULT

Source: SDR XMXR20210301001
OTHER · 2019-10-09 Matched by certificate designator
ATA 7500

Part: DIVERTER — CRACKED (PRECOOLER) · airframe 5,098 hrs · 3,392 cycles

CRACKED RH PRECOOLER INLET DIVERTER WELDS FOUND DURING INSPECTION IAW SERVICE LETTER 505-36-0003. REPLACED WITH OVERHAULED UNIT.

Source: SDR E07A201912020012
OTHER · 2018-12-04 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — FAILED (EMERGENCY LIGHTS) · airframe 4,548 hrs · 3,008 cycles

EMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON. REPLACED BATTERY PACK.

Source: SDR XMXR20191211014
OTHER · 2018-12-04 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — FAILED (EMERGENCY LIGHTS) · airframe 4,548 hrs · 3,008 cycles

EMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON. REPLACED BATTERY PACK.

Source: SDR XMXR20191211015
OTHER · 2018-03-02 Matched by certificate designator
ATA 7921

Part: PRECOOLER — FAILED · airframe 4,019 hrs · 2,626 cycles

INSPECTED THE LT ENGINE PRECOOLER IAW SIL505-36-0003 REV 2. FOUND BOTH PRECOOLER DIVERTER VANES CRACKED AND BROKEN OFF. DIVERTER VANES FOUND LAYING ON TOP OF PRECOOLER EXCHANGER BLOCKING INLET AIR TO PRECOOLER. DIVERTER VANES WERE REMOVED COMPLETELY AND GROUND OPERATIONAL CHECKS SHOWED NO BLEED FAILS.

Source: SDR E07A201803060002
OTHER · 2018-03-02 Matched by certificate designator
ATA 7921

Part: PRECOOLER — FAILED · airframe 4,019 hrs · 2,626 cycles

BLEED 1/2 FAIL. IAW SIL505-36-0003 INSPECTED THE ENGINE PRECOOLER AND FOUND INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLER. REPLACED.

Source: SDR E07A201803060001
OTHER · 2017-06-27 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — FAILED (EMERGENCY LIGHTS) · airframe 3,630 hrs · 2,349 cycles

EMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON

Source: SDR E07A201802140005
OTHER · 2017-06-27 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — FAILED (EMERGENCY LIGHTS) · airframe 3,630 hrs · 2,349 cycles

EMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON

Source: SDR E07A201802140004
FALSE WARNING · 2017-06-07 Matched by certificate designator
ATA 3243

Part: VALVE — LEAKING (PARKING BRAKE) · airframe 3,578 hrs · 2,318 cycles

AFTER BRAKE RELEASE. PARK BRAKE LIGHT STAYS ON OR IS INTERMITTENT COMING ON.

Source: SDR E07A201802120007
OTHER · 2015-07-14 Matched by certificate designator
ATA 5610

Part: SCREW — LOOSE (WINDSHIELD) · airframe 2,496 hrs · 1,597 cycles

FOUND TORQUE ON WINDSHIELD SCREW 1/8 TO 1/4 TURN LOOSE ON 80% OF SCREWS.

Source: SDR E07A20150819335
WARNING INDICATION · 2013-09-10 Matched by certificate designator
ATA 2120

Part: DUCT — BROKEN (RAM AIR) · airframe 1,090 hrs · 701 cycles

ON GROUND RUN ACFT WOULD NOT PASS PRESSURIZATION TEST. FOUND RAM AIR FIBERGLASS DUCT CRACKED AND LEAKING CABIN PRESSIZATION. INSTALLED A NEW DUCT ACFT WAS RETURNED TO SERVICE.

Source: SDR E07A201309110001