N339AA

ANDURIL INDUSTRIES INC ROADRUNNER · Fixed-wing multi-engine · 2 engines · 0 seats · Valid Registration

Registered owner: ANDURIL INDUSTRIES INC, CA (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

47 reports on file, 1995-02-24 – 2014-01-28.

NO TEST · 2014-01-28 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 97,378 hrs · 19,610 cycles

SEAT MOUNTED EMERGENCY LIGHTS AT 19HJ INOPERATIVE. REPLACED LAMP FOR SEAT MOUNTED EMERGENCY LIGHTS 19HJ. OPERATIONS CHECKED NORMAL.

Source: SDR AALA20140129001
Earlier reports · 1995–2013 · 46 reports

2013

WARNING INDICATION · 2013-10-04 Matched by certificate designator
ATA 3412

Part: TAT PROBE — INOPERATIVE (ZONE 200) · airframe 96,146 hrs · 19,362 cycles

LAX PILOT REPORTED TAT READING WAS INTERMITTENT & NEEDLE MOVING ERRATICALLY. FLIGHT RETURNED LAX LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED TWO RELAYS & TAT PROBE. SYSTEM GROUND CHECKED NORMAL OPERATION CLOSED.

Source: SDR AALA20131004012

2012

NO TEST · 2012-04-11 Matched by certificate designator
ATA 3350

Part: CHARGER — DEFECTIVE (EMERGENCY LIGHT) · airframe 91,197 hrs · 18,363 cycles

EMERGENCY SEAT MOUNTED ESCAPE LIGHTING PATH STAYED ON FROM ROWS 20HJ TO 30HJ AFTER REMOVING POWER FROM AIRCRAFT. REMOVED AND REPLACED BATTERY CHARGER MODULE ASSEMBLY AND BATTERY PACK LOCATED AT SEAT 25HJ SIDEWALL. OPS CHECKED NORMAL.

Source: SDR AALA20120412003
NO TEST · 2012-04-11 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DEFECTIVE (EMERGENCY LIGHT) · airframe 91,197 hrs · 18,363 cycles

EMERGENCY SEAT MOUNTED ESCAPE LIGHTING PATH STAYED ON FROM ROWS 20HJ TO 30HJ AFTER REMOVING POWER FROM AIRCARFT. REMOVED AND REPLACED BATTERY CHARGER MODULE ASSEMBLY AND BATTERY PACK LOCATED AT SEAT 25HJ SIDEWALL. OPS CHECKED NORMAL.

Source: SDR AALA20120412004

2011

NO TEST · 2011-09-22 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 89,359 hrs · 17,991 cycles

SEAT MOUNTED EMERGENCY LIGHT AT 10H INOPERATIVE. REPLACED LAMP FOR 10H SEAT MOUNTED EMERGENCY LIGHT. OPS CHECK NORMAL.

Source: SDR AALA20110922JFK01

2010

NO TEST · 2010-06-28 Matched by certificate designator
ATA 3350

Part: MODULE — INOPERATIVE (CABIN) · airframe 84,976 hrs · 17,092 cycles

SEAT EMERGENCY LIGHTS AT 10AB TO 18AB INOPERATIVE. REPLACED MODULE M9028 FOR SEAT EMERGENCY LIGHTS AT 10AB TO 18AB. OPS CHECKED NORMAL.

Source: SDR AALA20100629LAX01
OTHER · 2010-03-13 Matched by certificate designator
ATA 5411

Part: BUSHING — DAMAGED (RT PYLON) · airframe 84,007 hrs · 16,896 cycles

RIGHT PYLON ONLY THE INBOARD MOST AND OUTBOARD MOST MIDSPAR BUSHINGS WERE FOUND TO MOVE BY USING LIGHT PRESSURE. ACCOMPLISHED BORE/FASTENER HOLE REWORK PER EA B767-54-009486.

Source: SDR AALA20100317AFW01
OTHER · 2010-03-11 Matched by certificate designator
ATA 5313

Part: STRINGER SPLICE — CORRODED (FUSELAGE) · corrosion level 2 · airframe 84,007 hrs · 16,896 cycles

AN 8 INCH SECTION OF STRINGER 39 LEFT JUST BEFORE THE PRODUCTION STRINGER SPLICE AT STATION 1307 CORRODED. ACCOMPLISHED SPLICE REPAIR PER EA B767-53-009270.

Source: SDR AALA20100317AFW02
OTHER · 2010-03-05 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (FUSELAGE) · corrosion level 2 · airframe 83,997 hrs · 16,892 cycles

CORROSION WAS FOUND ON THE LEFT SECTION 46 WING-TO-BODY FAIRING SCREW HOLES COMMON TO THE FUSELAGE SKIN. AFTER CORROSION WAS REMOVED, 5 SCREW HOLES LOCATED BETWEEN STATIONS 1092 TO 1137 AND STRINGERS 37 AND 38 LEFT. HIGH FREQUENCY EDDY CURRENT WAS ACCOMPLISHED TO ENSURE ALL CORROSION HAD BEEN REMOVED. BOEING APPROVED TO REPAIR THE HOLES BY INSTALLING INTERNALLY COUNTERSUNK FREEZE PLUGS PER THE SRM. EA B767-53-009310.

Source: SDR AALA20100312AFW01
OTHER · 2010-03-01 Matched by certificate designator
ATA 5230

Part: BEAM — CORRODED (CARGO DOOR) · corrosion level 2 · airframe 83,997 hrs · 16,892 cycles

CORROSION WAS FOUND ON THE AFT CARGO DOOR NUMBER 4 BEAM INNER CHORD AT D STATION 175 COMMOM TO A NUT PLATE SCREW HOLE. THE CORROSION WAS REMOVED BY BLENDING LEAVING A MINIMUM REMAINING THICKNESS OF 0.093 INCH FROM PARENT THICKNESS OF 0.125. A REPAIR STRAP OF 0.063 INCH 7075-T6 WAS INSTALLED OVER THE BLEND EXTENDING 3 FASTENERS ON EITHER SIDE OF DEEPEST LOCATION. ALODINE, PRIMER AND CIC WERE APPLIED TO THE AREA FOR CORROSION PREVENTION. EA COMP-52-009208.

Source: SDR AALA20100315AFW01
OTHER · 2010-03-01 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (FUSELAGE) · corrosion level 2 · airframe 83,997 hrs · 16,892 cycles

SEVERE CORROSION WAS FOUND AT STATION 780 BETWEEN STRINGER 34 RIGHT AND STRINGER 35 RIGHT AT THE LOWER SKIN PANEL AFT EDGE. INSTALLED DOUBLER PER SRM 53-0-01-02R.

Source: SDR AALA20100309AFW01
OTHER · 2010-03-01 Matched by certificate designator
ATA 5230

Part: BEAM — CORRODED (CARGO DOOR) · corrosion level 2 · airframe 83,997 hrs · 16,892 cycles

CORROSION ON THE AFT CARGO DOOR NUMBER 4 BEAM INNER CHORD AT STATION 175 COMMON TO A NUT PLATE SCREW HOLE. CORROSION WAS REMOVED AND REPAIR STRAP OF 0.063 INCHES 7075-T6 WAS INSTALLED OVER THE BLEND EXTENDING 3 FASTENERS ON EITHER SIDE OF THE DEEPEST LOCATION. ALODINE, PRIMER AND CIC WERE APPLIED TO THE AREA FOR CORROSION PREVENTION. EA COMP-52-009208.

Source: SDR AALA20100309AFW06
OTHER · 2010-02-10 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 83,997 hrs · 16,892 cycles

PERFORMED SCHEDULED MAINTENANCE WORK CARD 0357. EMERGENCY LIGHTS FAILED TO ILLUMINATE FOR 10 MINUTES. PERFORMED MAINTENANCE WORK CARD 279A TO REPLACE EMERGENCY LIGHT POWER SUPPLY BATTERIES DURING CURRENT HEAVY C-CHECK.

Source: SDR AALA20100212AFW01

2009

OTHER · 2009-08-15 Matched by certificate designator
ATA 2150

Part: VALVE — FAULTY (AC PACK) · airframe 82,240 hrs · 16,524 cycles

PBI - INFLIGHT JFK-MIA. AIR INTERRUPT DUE TO RIGHT PACK FAILED EN ROUTE AND LEFT PACK ALREADY ON PLACARD. EMERGENCY DECLARED LANDED PBI WITHOUT INCIDENT. AIRCRAFT WAS FLOWN TO MIA FOR REPAIRS. ELBOW DUCT FROM AIR CYCLE MACHINE TURBINE TO REHEATER SHOWED SIGNS OF LEAKAGE WHERE TURBINE INLET TEMPERATURE BULB SCREWED IN. REPLACED TURBINE UNIT TEMPERATURE CONTROL MPN22023234, LOW LIMIT VALVE, AND THE TEMPERATURE BULB MPN2340239001 FOR THE RIGHT PACK. REPLACED AIR CYCLE MACHINE MPN6806404 SERIES 4 FOR THE LEFT PACK. SYSTEM GROUND CHECKED NORMAL.

Source: SDR AALA20090815TUL02
FLUID LOSS; SMOKE/FUMES/ODORS/SPARKS · 2009-03-21 Matched by certificate designator
ATA 2782

Part: PDU — LEAKING (LE SLAT) · airframe 80,599 hrs · 16,188 cycles

MIA - CREW REPORTED ELECTRIC BURNING SMELL AND HAZE IN COCKPIT. LANDED MIA WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND THE LEFT WING POWER DRIVE UNIT DRIVE MOTOR PUMP LEAKING HYDRAULIC FLUID. REPLACED BOTH HEAT EXCHANGERS, RECIRCULATION FANS, AND SLAT POWER DRIVE UNIT SHAFT SEALS. SYSTEM GROUND CHECK NORMAL OPERATION.

Source: SDR AALA2009032100001

2008

OTHER · 2008-07-23 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (BS 421-443 S36R) · airframe 78,744 hrs · 15,807 cycles

AFW FORWARD CARGO STRINGER WAS CORRODED. AREA OF DISCREPANCY WAS 22 INCHES IN LENGTH. REPAIRED PER SRM 53-00-03 2R2 WITH EXCEPTIONS PER MRB 767 3258.

Source: SDR AALA200802326
OTHER · 2008-07-23 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (FUSELAGE) · airframe 78,744 hrs · 15,807 cycles

AFW FORWARD CARGO STRINGER WAS CORRODED. AREA OF DISCREPANCY WAS 21 INCHES IN LENGTH. REPAIRED PER SRM 53-00-03 2R2 WITH EXCEPTIONS PER MRB 767 3256.

Source: SDR AALA200802328
OTHER · 2008-07-23 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (FUSELAGE) · airframe 78,744 hrs · 15,807 cycles

AFW FORWARD CARGO STRINGER WAS CORRODED. AREA OF DISCREPANCY WAS 22 INCHES IN LENGTH. REPAIRED PER SRM 53-00-03 2R2 WITH EXCEPTIONS PER MRB 767 3260.

Source: SDR AALA200802327

2006

NO TEST · 2006-11-28 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHT)

SFO - EMERGENCY EXIT LIGHTS AT LEFT AND RIGHT OVERWING INOPERATIVE. REPLACED BATTERY PACK AT M1209 FOR INOPERATIVE EMERGENCY EXIT LIGHTS AT LEFT AND RIGHT OVERWING. SYSTEM GROUND CHEKCED NORMAL OPERATION.

Source: SDR AALA20061122
NO TEST · 2006-07-10 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT)

JFK- EMERGENCY FLOOR PATH LIGHT AT SEAT 22B IS MISSING LENS AND BULBS ARE INOPERATIVE. REPLACED LENS AND BULBS FOR EMERGENCY FLOOR PATH LIGHT AT SEAT 22B. SYSTEM GROUND CHECKED NORMAL OPERATION.

Source: SDR AALA20060450
NO TEST · 2006-04-22 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHT)

LAX - EMERGENCY LIGHTS FROM SEAT 2B TO 9B, 2H TO 9H AND 20H TO 26H INOPERATIVE. REPLACED BATTERY PACKS FOR EMERGENCY LIGHTS FROM SEAT 2B TO 9B, 2H TO 9H AND 20H TO 26H. SYSTEM GROUND CHECKED NORMAL OPERATION.

Source: SDR AALA2060253

2005

PARTIAL RPM/PWR LOSS · 2005-02-15 Matched by certificate designator
ATA 7320

Part: SWITCH — INOPERATIVE (ZONE 100)

LAX - INFLIGHT T0019/15 LEFT ENGINE ROLLED BACK AT 300 FEET. FULL CONTROL MOVED CUTOFF AND RUN. ENGINE NORMAL AT TOUCHDOWN. THROTTLES PARKED UP THROUGH TOUCHDOWN AND ROLLOUT. REVERSED NORMALLY. REPLACED LEFT HAND ENGINE FUEL FILTER AND LEFT AND RIGHT HAND FUEL CUT OFF SWITCHES. SYSTEM GROUND CHECKED NORMAL OPERATION.

Source: SDR AALA20050118

2004

NO TEST · 2004-11-24 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

EMERGENCY LIGHTS FROM SEATS 31A TO 37A INOPERATIVE. REPLACED BATTERY PACK AND CHARGER FOR EMERGENCY LIGHTS FROM SEATS 31A TO 37A. SYSTEM GROUND CHECKED NORMAL OPERATION.

Source: SDR AALA20041164
OTHER · 2004-11-23 Matched by certificate designator
ATA 3350

Part: MODULE — INOPERATIVE (EMERGENCY LIGHTS)

JFK - LEFT HAND EMERGENCY LIGHTS AT ROWS 31 TO 37 INOPERATIVE. REPLACED BATTERY PACK AND BATTERY CONTROL MODULE AT ROW 35AB FOR LEFT HAND EMERGENCY LIGHTS AT ROWS 31 TO 37. SYSTEM GROUND CHECKED NORMAL OPERATION.

Source: SDR AALA20041159

2003

SMOKE/FUMES/ODORS/SPARKS · 2003-09-09 Matched by certificate designator
ATA 2530

Part: OVEN — MALFUNCTIONED (GALLEY)

LAX - FLT 33 - HEAVY SMOKE EMERGING FROM THE FIRST CLASS GALLEY. MAINTENANCE FOUND RESIDUE IN CONTACT WITH THE OVEN HEATING ELEMENT. REMOVED AND REPLACED OVEN. GROUND OPS CHECK NORMAL. (M)

Source: SDR AALA20031035
NO TEST · 2003-03-26 Matched by certificate designator
ATA 3350

Part: BALLAST — INOPERATIVE (EMERGENCY LIGHT)

DURING OVERNIGHT MAINTENANCE, LEFT OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED LEFT OVERWING EMERGENCY EXIT LIGHTS BALLAST. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20030372
NO TEST · 2003-02-05 Matched by certificate designator
ATA 2560

Part: FLASHLIGHT — INOPERATIVE (CABIN)

SFO - DURING OVERNIGHT MAINTENANCE, FORWARD CENTER RIGHT FLIGHT ATTENDANT EMERGENCY EXIT FLASHLIGHT INOPERATIVE. REPLACED FORWARD CENTER RIGHT FLIGHT ATTENDANT EMERGENCY EXIT FLASHLIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20030162

2002

WARNING INDICATION · 2002-03-31 Matched by certificate designator
ATA 2131

Part: CONTROLLER — FAILED (CABIN PRESSURE)

JFK - FLT 15 - EN ROUTE JFK-LAX - SHORTLY AFTER TAKEOFF EICAS MESSAGE INDICATED NO NR 1 AND 2 CABIN ALTIMETER INDICATION. MANUAL MODE ALLOWED LIMITED VALVE CONTROL. RETURNED TO JFK AND LANDED WITHOUT FURTHER INCIDENT. REPLACED NR 1 AUTO PRESSURE CONTROLLER. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20020379
NO TEST · 2002-01-14 Matched by certificate designator
ATA 3350

Part: CONNECTOR — DEFECTIVE (CABIN)

SFO - DURING OVERNIGHT MAINTENANCE, FOUND EMERGENCY ESCAPE PATH LIGHTING AT SEAT 33H INOPERATIVE. REPLACED CONNECTOR AND PINS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20020041

2001

NO TEST · 2001-11-22 Matched by certificate designator
ATA 3350

Part: LIGHT — DISCONNECTED (CABIN)

SFO - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 32B INOPERATIVE. RECONNECTED EMERGENCY EXIT LIGHT AT SEAT 32B. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20012062

2000

SMOKE/FUMES/ODORS/SPARKS · 2000-01-13 Matched by certificate designator
ATA 2300

Part: PHONE — SHORTED (CABIN)

ICT - FLT 201 - EN ROUTE CREW REPORTED ELECTRICAL BURNING SMELL IN AFT CABIN. LANDED ICT WITHOUT INCIDENT. REPLACED AT&T PASSENGER PHONE. SYSTEM GROUND CHECK NORMAL OPERATION. PHONE SHORTED OUT. (M)

Source: SDR AALA20000081

1999

NO TEST · 1999-09-24 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (ROW 17 HJ)

SFO - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING AT 17 HJ TO 30 HJ INOPERATIVE. REPAIRED WIRES AT 17 HJ. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)

Source: SDR AALA991447
NO TEST · 1999-09-14 Matched by certificate designator
ATA 3350

Part: SOCKET — DEFECTIVE (LT EMER EXIT)

SFO - DURING OVERNIGHT MAINTENANCE, LEFT FORWARD OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED LIGHT SOCKET IN LEFT FORWARD OVERWING EMERGENCY EXIT LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA991389
FALSE WARNING · 1999-06-06 Matched by certificate designator
ATA 2613

Part: CONNECTOR — LOOSE (CARGO COMPT)

RDU - FLT 174 - DURING CRUISE, FORWARD CARGO OVERHEAT STATUS MESSAGE AND OVERHEAD LIGHT ILLUMINATED IN FLIGHT. AIR INTERRUPTED BACK TO RDU AND LANDED WITHOUT INCIDENT. NO SIGN OF SMOKE OR HOT CONDITION. SECURED CANNON PLUG ON TEMPERATURE SWITCH. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA990847

1998

OTHER · 1998-11-30 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 855-999)

AFW - FLOORBEAM AT RBL 33 HAD CORROSION BLENDED BEYOND SRM LIMITS. ROTO-PEEN BLENDED AREAS PER SRM. ALODINED ALL BARE ALUM SURFACES FINISH BLENDED AREAS WITH 2 COATS BMS 10-11 PRIMER. FILL BLENDS WITH BMS PROSEAL 870. (M)

Source: SDR AALA984234
OTHER · 1998-11-30 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 780-920)

AFW - FLOORBEAM AT LBL 11 HAD CORROSION BLENDED BEYOND SRM LIMITS. ROTO-PEEN, BLENDED AREAS PER SRM. ALODINE ALL BARE ALUM SURFACES FINISH BLENDED AREAS WITH 2 COATS OF BMS10-11 PRIMER. FILL BLENDS WITH BMS5-95 PROSEAL 870. (M)

Source: SDR AALA984232
OTHER · 1998-11-30 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 1565)

AFW - FLOORBEAM AT STATION 1565 LBL 77 HAD CORROSION BLENDED BEYOND SRM LIMITS. FABRICATE REPAIR STRAP OUT OF 301 1/2H STAINLESS STEEL .050 INCH THICK. ALODINE ALL BARE ALUMINUM SURFACE FINISH BLEND AND REPAIR PARTS WITH 2 COATS BMS10-11 PRIMER FILL BLENDS WITH BMS5-92. INSTALL REPAIR STRAP WET WITH BMS5-95. (M)

Source: SDR AALA984233
OTHER · 1998-11-29 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE)

AFW - FLOORBEAM AT RBL 54 HAS CORROSION BLENDED BEYOND SRM LIMITS. ROTO PEEN BLENDED AREA PER SRM, ALODINED ALL BARE ALUM SURFACES. FINISH BLENDED WITH 2 COATS OF BMS10-11, PRIMER FILL BLENDS WITH BMS 5-95 PROSEAL 870. (M)

Source: SDR AALA984236
OTHER · 1998-11-28 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 266)

AFW - FLOORBEAM AT STATION 266 RBL 26 HAD CORROSION BLENDED BEYOND SRM LIMITS. FABRICATE REPAIR STRAP OUT OF 301.5 INCH STAINLESS STEEL .050 INCH THICK. ALODINE, FINISH BLEND AND REPAIR PARTS WITH 2 COATS OF BMS10-11 PRIMER, FILL BLENDS WITH BMS 5-92. INSTALL REPAIR STRAP WET WITH BMS 5-95 SEALANT. (M)

Source: SDR AALA984237
NO TEST · 1998-06-20 Matched by certificate designator
ATA 3397

Part: WIRE — LOOSE (CABIN)

SFO - DURING OVERNIGHT MAINTENANCE, FORWARD GALLEY CROSS AISLE EMERGENCY LIGHTS INOPERATIVE. REPLACED SPLICE ON FORWARD GALLEY CROSS AISLE EMERGENCY LIGHTS. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)

Source: SDR AALA981200
NO TEST · 1998-01-20 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (CABIN)

SFO - DURING OVERNIGHT CHECK, DISCOVERED EMERGENCY EXIT SIGN AT LEFT AFT FLIGHT ATTENDANT SEAT INOPERATIVE. REPLACED EMERGENCY EXIT SIGN WIRE AT LEFT AFT FLIGHT ATTENDANT SEAT. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)

Source: SDR AALA980194

1997

SMOKE/FUMES/ODORS/SPARKS · 1997-09-29 Matched by certificate designator
ATA 2530

Part: OVEN — DEFECTIVE (GALLEY)

SFO - FLT 0035 - DURING APPROACH TO SFO, ELECTRICAL ODOR NOTED IN CABIN WITH NO OTHER ABNORMAL INDICATIONS. AIRCRAFT LANDED SFO WITHOUT INCIDENT. REPLACED MID-GALLEY NR 3 OVEN. SYSTEM GROUND CHECKED, NORMAL OPERATION WITH NO ELECTRICAL ODOR NOTED. (X)

Source: SDR AALA971846
ELECT. POWER LOSS-50 PC · 1997-04-12 Matched by certificate designator
ATA 2421

Part: IDG — FAILED (LT ENGINE)

ORD - FLT 0682 - LEFT GENERATOR DRIVE LIGHT FLICKERED BEGINNING AND DURING CLIMB-OUT. DRIVE LIGHT CAME ON CONTINUOUSLY AFTER 1.5 HOURS OF FLIGHT. LEFT GENERATOR DRIVE DISCONNECTED. 5383/PLACARDED LT GEN INOP PER MEL 24-1. SERVICED BOTH ENG IDG TO OVERFLOW. APU OIL LEVEL FULL. ACCOMPLISHED MPM 24-01. ENTERED IN MIC. AUTH 4-193DC-B. REMOVED AND REPLACED IDG IAW MM 24-11-01-4-2. OPS CHECK GOOD, LEAK CHK GOOD. DISC GOOD. OPS CHECK GOOD AFTER DISCONNEECT. REMOVED MEL 4-193DC-B AND CLEARED MIC. (X)

Source: SDR AALA970732

1996

NO TEST · 1996-01-03 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (CABIN)

SFO - DURING OVERNIGHT CHECK, EMERGENCY EXIT LIGHTS AT FORWARD CROSS AISLE INOPERATIVE. REPAIRED BROKEN EMERGENCY EXIT LIGHT WIRE AT FORWARD CROSS AISLE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA960009

1995

NO TEST · 1995-10-22 Matched by certificate designator
ATA 3350

Part: EEL WIRE — BROKEN (CABIN)

SFO - DURING OVERNIGHT CHECK, RT FORWARD GALLEY EMERGENCY FLOOR LIGHT FOUND INOPERATIVE. REPAIRED BROKEN EMERGENCY FLOOR LIGHT WIRE BY RT FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION. (X)

Source: SDR AALA951836
NO TEST · 1995-04-16 Matched by certificate designator
ATA 3350

Part: EEL CONNECTOR — LOOSE (CABIN)

SFO - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS AT PAX SEAT 20 AB INOPERATIVE. RESERCURED LOOSE EMERGENCY FLOOR LIGHT CONNECTOR AT PAX SEAT 20 AB. SYSTEM GROUND CHECKED NORMAL OPERATION. (W)

Source: SDR AALA950683
NO TEST · 1995-02-24 Matched by certificate designator
ATA 3350

Part: CONNECTOR — LOOSE (CABIN)

SFO - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHT AT PAX SEAT 17AB INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT CONNECTOR AT PAX SEAT 17AB. SYSTEM GROUND CHECKED NORMAL OPERATION. (W)

Source: SDR AALA950335