NO TEST · 2024-09-23 Matched by certificate designator
ATA 2560

Part: MEGAPHONE — INOPERATIVE (ZONE 200) · airframe 17,819 hrs · 8,085 cycles

THIS AC WAS NOT OOS FOR THIS EVENT. REFERENCE LP485250 ITEM 3, AFT MEGAPHONE INOP. REMOVED AND REPLACED AFT MEGAPHONE IAW AMM 25-65-51-710-002-A. OPS CHECK GOOD.

Source: SDR F3LA2024092400144
OTHER · 2024-05-25 Matched by certificate designator
ATA 3350

Part: BATTERY — INOPERATIVE (EMERGENCY LIGHTS) · airframe 1,686,230 hrs · 7,590 cycles

REFERENCE LTPR N/R 5001321690-0010 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SHCEDULED MX. DURING INCOMING CHECK FOUND EPSU BATTERIES 11WL INOP REPLACEMENT REQUIRED IAW AMM 33-51-38-000-002-A REV/98. REPLACED EPSU BATTERY AND POWER SUPPLY 11WL IAW AMM 33-51-38-400-001 CONF 00 REV. 98MX ACTION IS ACCEPTABLE.

Source: SDR F3LA2024060700089
OTHER · 2024-05-22 Matched by certificate designator
ATA 5320

Part: DOOR SILL — CORRODED (ZONE 100) · corrosion level 2 · airframe 16,862 hrs · 7,590 cycles

REFERENCE LTPR NR 5001320878-0010 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. CORROSION ON RH AFT DOOR SILL BEAM NUT PLATE HOLE AT FRAME 68 REQUIRES REPAIR AS PER A320NEO SRM 53-41-14-300-001 REV. 40. REPAIRED RH AFT DOOR SILL AT FRAME 68 AS PER A320NEO SRM 53-41-14-300-001 REV. 40.

Source: SDR F3LA2024060500088
OTHER · 2024-05-22 Matched by certificate designator
ATA 5320

Part: SHEAR PLATE — CRACKED (FRSM 69-70) · airframe 16,862 hrs · 7,590 cycles

REFERENCE LTPR NR 5001320901-0010 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. CRACK WAS FOUND ON L/H SHEAR PLATE FR69-70, REPLACEMENT IS REQUIRED AS PER A320NEO SRM 51-72-11 REV. 400. L/H SHEAR PLATE FR69-70 HAS BEEN REPLACED AS PER A320NEO SRM 51-72-11-911-001 REV. 40. MX ACTION IS ACCEPTABLE.

Source: SDR F3LA2024060500086
OTHER · 2024-05-22 Matched by certificate designator
ATA 5320

Part: TRACK — CORRODED (ZONE 100) · corrosion level 2 · airframe 16,862 hrs · 7,590 cycles

REFERENCE LTPR NR 5001321122-0010 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. CORROSIONFOUND ON RAIL AT Y503.2 FWD CABIN BETWEEN FR12-16 REQUIRES EVALUATION AS PER A320NEO SRM TASK 53-11-14-283-007 REV 40. PERFORMED REPLACEMENED REPLACEMENT OF RAIL AT Y503.2 AS PER A320NEO SRM 51-72-11 REV. 40. MX ACTION IS ACCEPTABLE.

Source: SDR F3LA2024060500087
OTHER · 2024-05-22 Matched by certificate designator
ATA 5320

Part: DOOR SILL — CORRODED (FRM 68) · corrosion level 2 · airframe 16,862 hrs · 7,590 cycles

REFERENCE LTPR NR 5001320875-0010 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. CORROSION ON LH AFT DOOR SILL BEAM NUT PLATE HOLE AT FRAME 68 REQUIRES REPAIR AS PER A320NEO SRM 53-41-14-300-001 REV. 40. REPAIRED LH AFT DOOR SILL AT FRAME 68 AS PER A320NEO SRM 53-41-14-300-001 REV. 40. MX ACTION IS ACCEPTABLE.

Source: SDR F3LA2024060500085
OTHER · 2024-05-22 Matched by certificate designator
ATA 5320

Part: SHEAR PLATE — CRACKED (FRMS 69-70) · airframe 16,862 hrs · 7,590 cycles

REFERENCE LTPR NR 5001320902-0010 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. CRACK WAS FOUND ON R/H SHEAR PLATE FR69-70, REPLACEMENT IS REQUIRED AS PER A320NEO SRM 51-72-11 REV. 400. R/H SHEAR PLATE FR69-70 HAS BEEN REPLACED AS PER A320NEO SRM 51-72-11-911-001 REV. 40. MX ACTION IS ACCEPTABLE.

Source: SDR F3LA2024060500084
Earlier reports · 2019–2023 · 8 reports

2023

NO TEST · 2023-12-06 Matched by certificate designator
ATA 2565

Part: SLIDE RAFT — FAILED (ZONE 200) · airframe 15,430 hrs · 6,929 cycles

DISCREPANCY: AC WAS IN SCHEDULED MAINTENANCE AND WAS NOT OOS DUE TO THIS ISSUE. REFERENCE LOG PAGE LP384906 ITEM 1, DURING EPSU TEST, MESSAGE SHOWN ESCAPE SLIDE L1/EPSU 10WL FWD1. CORRECTIVE ACTION: L1 DOOR ESCAPE SLIDE RAFT PACK ASSEMBLY WAS REMOVED AND REPLACED IN REF. TO AMM 25-62-44-000-007-A/25-62-44-400-007-A, OPS CHECK GOOD. A/C OK FOR SERVICE. TW F9TAB1100C DD 12/2023.//END//

Source: SDR F3LA2023120600227

2022

WARNING INDICATION · 2022-12-22 Matched by certificate designator
ATA 2910

Part: HYDRAULIC SYSTEM — MALFUNCTIONED (B SYSTEM) · airframe 12,284 hrs · 5,531 cycles

BTB HYD B SYS LO PR ECAM ON ENG 2 START - PRESSURE SHOWED 700-900 PSI - PUMP SHOULD START UPON ENG 1 START DID NOT - SHOWED AMBER HASH - SLOWLY BUILT UP PRESSURE TO 2950-3000 PSI OVER ENG 2 START TIME FRAME. OPEN

Source: SDR F3LA2022231200173
SMOKE/FUMES/ODORS/SPARKS · 2022-12-19 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (COCKPIT) · airframe 12,257 hrs · 5,520 cycles

CREW REPORTED AN ODOR EVENT IN COCKPIT. C/W TSM 05-50-00-810-831-A, LEAK OF HYD SYS GOOD IAW AMM 29-00-00-790-001 NO ODOR NOTED . ACFT OK TO CONTINUE.

Source: SDR F3LA2022201200168
FALSE WARNING · 2022-12-18 Matched by certificate designator
ATA 2913

Part: WARNING LIGHT — FALSE ACTIVATION (HYD PUMP) · airframe 12,257 hrs · 5,520 cycles

BLUE ELEC HYD PUMP FAILED ON PUSHBACK. FOLLOWED TSM 29-12-00-810-804-A UP TO STEP 3, B. NO FAULTS NOTED. OPS CHECK GOOD PER AMM 29-2-00-710-001. A/C OK FOR SERVICE.

Source: SDR F3LA2022201200169
NO TEST · 2022-09-15 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (EMERGENCY LIGHTS) · airframe 11,478 hrs · 5,192 cycles

FWD EPSU FAILS EMERGENCY LIGHTS TEST 10WL. REMOVED AND REPLACED FWD EPSU BATTERY PACK ON 10WL REF AMM 33-51-38-000-002-A & 33-51-38-400-002-A OPS CHECK GOOD.

Source: SDR F3LA2022091600110

2019

NO TEST · 2019-11-23 Matched by certificate designator
ATA 2565

Part: POWER SUPPLY — NO TEST (DOOR SLIDE) · airframe 3,550 hrs · 1,551 cycles

DISCREPANCY: REFERENCE LOG PAGE LPL 224900, ITEM 1. ESPU FAILED TEST. CORRECTIVE ACTION: REMOVED AND REPLACED DOOR SLIDE, REFERENCE AMM 25-62-44. PB 401, OPS CHECK GOOD.

Source: SDR F3LA201911270143
SMOKE/FUMES/ODORS/SPARKS · 2019-06-24 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 1,948 hrs · 840 cycles

FLIGHT ATTENDANT IN AFT GALLEY REPORTED DIRTY SOCK SMELL AS AIRCRAFT PULLED INTO GATE. APU WAS RUNNING, APU BLEED OFF, ENG #1 WAS RUNNING, ENG #2 SHUTDOWN. APU HAD ONLY BEEN RUNNING ABOUT 4 MINUTES. AIRCRAFT WAS GROUNDED DUE TO DISCREPANCY. MX PERFORMED OPS RUN OF ENGINE #1 AND #2 AT GATE WITH PACKS ON/OFF. COULD NOT CLEARLY IDENTIFY ANY TYPE OF ODOR, PER EA # A0-21T-34386. PERFORMED TROUBLESHOOTING PER TSM 05-50-00-810-831-A, POSSIBLE SOURCE IDENTIFIED AS TYPE 9, MISCELLANEOUS, NO ABNORMAL SMELLS IDENTIFIED. OK TO CONTINUE.

Source: SDR F3LA2019062600044
WARNING INDICATION · 2019-05-08 Matched by certificate designator
ATA 3020

Part: DUCT — LOOSE (NR 2 ENGINE) · airframe 1,475 hrs · 635 cycles

DISCREPANCY: REFERENCE LP1202019-2, ENG 2 FIRE WARNING WHEN ABOVE IDLE AND IN FLIGHT. CORRECTIVE ACTION - FOUND LOOSE AND MISSING FASTENERS AT JUNCTION OF 7TH STAGE COMPRESSOR AIR DUCT TO ENGINE CASE, INSTALLED BOLTS AND SEALS ON BLEED DUCT REF AMM SUBTASK 30-21-49-420-095A USED T/W F9TAB2940C DUE CAL 03/20 PERFORMED IDLE LEAK CHECK OF NR 2 ENGINE NO LEAKS NOTED REF AMM 71-00-00-710-815./END/

Source: SDR F3LA2019051000036