N35HD

RAYTHEON AIRCRAFT COMPANY C90A · Valid Registration

Registered owner: GUARDIAN FLIGHT LLC, TX (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
GUARDIAN FLIGHT, LLC. (G1IA)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

I · 2023-03-14 Matched by certificate designator
ATA 3400

EADI AND EHSI DISPLAYS INDICATED ONLY RANDOM DOTS ON THE DISPLAYS. AFTER A WHILE, THE NORMAL DISPLAY RESUMED. THEN, BOTH DISPLAYS BECAME EXTREMELY DISTORTED AND REMAINED THAT WAY FOR THE DURATION OF THE FLIGHT. REPLACED DPU WITH OVERHAULED.

Source: SDR G1IA20230314040 · FAA SDRS
B · 2021-10-01 Matched by certificate designator
ATA 2140

SHORTLY AFTER DEPARTURE FROM KAPA EN ROUTE TO KRCV AT FL200 MEDICAL CREW ALERTED PILOT TO SMOKE IN THE CABIN. MEDICAL CREW ALSO ADVISED THE RIGHT SIDE CABIN AIR OUTLET AND WALL NEAR THE RIGHT REAR FACING SEAT WAS ABNORMALLY HOT. CREW DONNED OXYGEN MASKS IAW THE MEMORY ITEMS AND CHECKLIST. PILOT DECLARED AN EMERGENCY AND BEGAN AN IMMEDIATE RETURN TO KAPA. DURING AND RETURN MANEUVERING THE SMOKE BEGAN TO INCREASE IN INTENSITY. PILOT BEGAN A DESCENT WITH ASSOCIATED POWER REDUCTION AND IAW C90 QRH THE PILOT TURNED OFF THE ELECTRIC HEAT (WAS IN NORM), TURNED THE CABIN TEMP MODE OFF (WAS IN AUTO), AND TURNED THE VENT BLOWER TO HIGH. MED CREW ADVISED AT THAT POINT THE SMOKE WAS DISSIPATING. CREW SAFELY RECOVERED THE AIRCRAFT AT KAPA. CORRECTIVE ACTION: GAINED ACCESS TO HEATER DUCTS AND COILS. INSPECTED DUCTS FOR DAMAGE AND DETERIORATION. NONE NOTED. INSPECTED HEATER COILS FOR DAMAGE. NONE FOUND. REMOVED FOD FROM INSIDE AREA TO ENSURE NO POSSIBILITY OF FUTURE COMBUSTION. REASSEMBLED DUCTS AND COILS. FUNCTIONAL TESTED SYSTEM WITH SATISFACTORY RESULTS. NO FURTHER DEFECTS NOTED.

Source: SDR G1IA20211001021 · FAA SDRS