N375DL

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

29 reports on file, 1995-04-12 – 2005-09-24.

OTHER · 2005-09-24 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CRACKED (BS 678) · airframe 48,769 hrs · 37,468 cycles

FUSELAGE/OVERWING LONGITUDINAL FLOORBEAMS, CRACK REPAIR DURING ACCOMPLISHMENT OF INSPECTIONS OF THE LT/RT BL 24.8 OVERWING LONGITUDINAL FLOORBEAMS PER SI 3-056673-12AD, FATIGUE CRACKS WERE DETECTED IN THE WEB DOUBLERS AND BS 678 VERTICAL STIFFENER. CRACKED DOUBLERS AND STIFFENERS REPLACED AND INSTALLS 3-056673-3AD MODIFICATION PER ER/A 450791-14AD.

Source: SDR DL73S050609
Earlier reports · 1995–2004 · 28 reports

2004

OTHER · 2004-08-20 Matched by certificate designator
ATA 5551

Part: FITTING — CORRODED (HORIZONTAL STAB) · airframe 46,158 hrs · 35,494 cycles

HORIZONTAL STABILIZER, LT OB STAB, NR3 LUG, CORROSION. CORROSION WAS FOUND IN THE BORE OF THE LT OB STAB SECTION REAR SPAR UPPER ATTACH LUG DURING INSPECTION IAW E.O. 3-53025-3AD. THE BORE WAS OVERSIZED BEYOND THE E.O. LIMITS TO REMOVE DAMAGE AND AN OVERSIZED BUSHING WAS INSTALLED. THE REPAIR WAS ACCOMPLISHED IAW ER/A 092266-14AD.

Source: SDR DL73S040786
OTHER · 2004-08-20 Matched by certificate designator
ATA 5553

Part: ATTACH FITTING — CORRODED (VERTICAL STAB) · airframe 46,158 hrs · 35,494 cycles

VERTICAL STABILIZER ATTACH LUGS FOUND CORRODED ON THE NR 3 AND NR 6 FORE AND AFT FACES. REPAIRED IAW ERA 092521-14.

Source: SDR DL73S040783
OTHER · 2004-08-20 Matched by certificate designator
ATA 5330

Part: SKIN — GOUGED (FUSELAGE) · airframe 46,158 hrs · 35,494 cycles

FUSELAGE SKIN SUFFERED GROUND DAMAGE AT STATION 969 BETWEEN STR 20R AND 21R. REPAIRED IAW ERA 092483-14.

Source: SDR DL73S040784
OTHER · 2004-08-20 Matched by certificate designator
ATA 5711

Part: STIFFENER — CRACKED (WING SPAR) · airframe 46,158 hrs · 35,494 cycles

WING CENTER SECTION REAR SPAR STIFFENER FOUND CRACKED AT RBL 6.15. REPAIRED IAW ERA 092296-14.

Source: SDR DL73S040785
OTHER · 2004-08-20 Matched by certificate designator
ATA 5343

Part: FITTING — CORRODED (STRUT SUPPORT) · airframe 46,158 hrs · 35,494 cycles

MLG SIDE STRUT SUPPORT FITTING AT FUSELAGE STATION 685 WAS FOUND WITH LUB BORE CORROSION ON BOTH THE RT AND LT SIDES. REPAIRED IAW ERA 092411-14.

Source: SDR DL73S040782
OTHER · 2004-08-17 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (FUSELAGE) · airframe 46,158 hrs · 35,494 cycles

FUSELAGE FRAME AT STATION 727A AND STRINGER 25L SUFFERED SERVICE DAMAGE FROM CARGO, AREA IS PSE F34. REPAIRED IAW ERA 092302-14.

Source: SDR DL73S040769
WARNING INDICATION · 2004-06-13 Matched by certificate designator
ATA 2133

Part: OUTFLOW VALVE — MALFUNCTIONED (CABIN PRESSURE) · airframe 45,929 hrs · 35,323 cycles

PASSING FL 220 CABIN UNABLE TO MAINTAIN PRESSURIZATION. DESCENT INITIATED QRH PROCEDURES ACCOMPLISHED. NO INJURIES OR AIRCRAFT DAMAGE. REPLACED AIRCRAFT OUTFLOW VALVE ASSEMBLY PER M/M. SYSTEM CHECKS NORMAL.

Source: SDR DL73S040549
SMOKE/FUMES/ODORS/SPARKS · 2004-03-25 Matched by certificate designator
ATA 2120

Part: ODOR — DETECTED (CABIN) · airframe 45,375 hrs · 34,895 cycles

ON CLIMBOUT, F/A REPORTED STRONG ODOR IN AFT CLOSET AND LAV AREA AT FL 310 ODOR DISSIPATED. INSPECTED COCKPIT AND CABIN, NO PROBLEMS NOTED. INSPECTED BEHIND COFFEEMAKERS, NO ODORS PRESENT. CYCLED CABIN LIGHTING, ALL LIGHTS OPS NORMAL. RAN BOTH ENGINES AT PWR WITH PACKS, NO ODORS NOTED. A/C OK FOR SERVICE.

Source: SDR DL73S040271

2003

OTHER · 2003-09-05 Matched by certificate designator
ATA 3417

Part: ADC — FAILED (E/E BAY) · airframe 44,106 hrs · 33,876 cycles

AFTER LIFTOFF F/O ALT AND AIRSPEED FAILED. CONTACTED ATL MTC RTN TO CVG. REPLACED NR 2 DADC.

Source: SDR DL73S030815
NO TEST · 2003-07-10 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — DISCHARGED (CABIN) · airframe 43,867 hrs · 33,756 cycles

LEFT OVER WING DOOR EXIT SIGN INOP DURING TEST. REPLACED POWER SUPPLY

Source: SDR DL73K030625

2002

NO TEST · 2002-08-21 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — DISCHARGED (CABIN) · airframe 41,404 hrs · 32,743 cycles

EMERGENCY EXIT LIGHTS POWER SUPPLY FAILED ON L/O INSP. REPLACED POWER SUPPLY.

Source: SDR DL73K021109
OTHER · 2002-07-26 Matched by certificate designator
ATA 5310

Part: FRAME — CRACKED (STA 616 WL202) · airframe 41,200 hrs · 32,661 cycles

FUSELAGE FRAME AT STA 616 LH/RH WERE CRACKED IN IN BD/OUTBD FLANGEAT LOCATION ATTACHING TO FLOOR STUB BEAM. D AMAGE WAS FOUND DURING INSPECTION PER SI 3-85751-12. CORRECTIVE ACTION: DAMAGE WAS REPAIRED PER ER/A 383607-14.

Source: SDR DL73K020868
INFLIGHT SEPARATION; F.O.D. · 2002-02-27 Matched by certificate designator
ATA 7110

Part: BULLET — SEPARATED (ENG INTAKE) · airframe 40,011 hrs · 32,165 cycles

ON TAKEOFF ROLL, A LOUD THUD WAS HEARD AND AIRCRAFT PULLED SLIGHTLY TO THE LEFT. TAKEOFF WAS ABORTED. ENGINE PARAMETERS WERE NORMAL. UPON INSPECTION FOUND NR 1 ENGINE NOSE BULLET MOUNTING STUDS HAD PULLED FROM N1 TACH GEARBOX AND BULLET BECAME DISLODGED IN THE INLET OF ENGINE. NO DAMAGE WAS FOUND OTHER THAN TO THE BULLET ITSELF. ALL PARTS WERE ACCOUNTED FOR AND NO FURTHER DAMAGE TO THE ENGINE WAS FOUND DURING INSPECTION. N1 TACH GEARBOX AND NOSE BULLET IN NUMBER 1 ENGINE WERE REPLACED. ENGINE POWER RUN WAS ACCOMPLISHED PER PFHB AND AIRCRAFT WAS RETURNED TO SERVICE.

Source: SDR DL73K020235
NO TEST · 2002-02-06 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 39,858 hrs · 32,102 cycles

EMERGENCY LIGHT OVERHEAD SEAT ROW 2 DEF INOP. REPLACED BULB.

Source: SDR DL73K020147

2001

FALSE WARNING · 2001-12-26 Matched by certificate designator
ATA 2612

Part: PLUG — FAILED (COCKPIT) · airframe 39,553 hrs · 31,975 cycles

ON DESCENT INTO JFK FLT NR 2568. APU DET INOP LIGHT CAME ON THEN WENT OUT. APPROX 5 MIN LATER AT 1000 FT AGL, APU FIRE HANDLE AND FIRE WARNING WITH BELL CAME ON. APU FIRE BOTTLE EXTINGUISHED AND RED FIRE HANDLE STAYED ON. APU WAS NOT RUNNING. FOUND APU FIRE INDICATION HARNESS LOOP PLUGS FAILED. REPLACED SAME AND REPLACED APU FIRE BOTTLE.

Source: SDR DL73K011981
OTHER · 2001-03-07 Matched by certificate designator
ATA 3310

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 36,997 hrs · 30,895 cycles

PASSENGER SEAT 17C AND ALL SEAT EPATH LITES AFT OF IT ARE INOP. FOUND BATTERY PACK INOP. DAL P/N 337101963

Source: SDR DL73K010381

2000

FLT CONT AFFECTED · 2000-10-11 Matched by certificate designator
ATA 2782

Part: ACTUATOR — FAILED (NR 4 SLAT) · airframe 35,644 hrs · 30,297 cycles

DURING APP WHEN FLAPS 2 SELECTED L/E FLAP TRANS LIGHT STAYED ILLUM AND 4 SLAT SHOWED UNSAFE YELLOW ON OVHD PANEL FLAPS WERE SELECTED TO 5 AND ALL WENT GREEN AND SHOWED SAFE. ABOUT 5 SECS LATER L/E FLAP TRANS LIGHT REILLUM AND 4 SLAT SHOWED UNSAFE AGAIN. FLAPS WERE SEL TO 10 AND ALL WENT SAFE AND GREEN FOR REST OF APP AND ALL FLAP SETTINGS HIGHER THAN 5. WHEN 4 SLAT SHOWED UNSAFE CO PILOT VISUALLY COULD SEE 4 FLAP UP WHEN OTHERS WERE DOWN. REMOVED AND REPLACED NR 4 SLAT ACT PER MM. INSP R/INSTALL OF SLAT ACT PER MM RII C/W 655177.

Source: SDR DL73E001979
OTHER · 2000-05-23 Matched by certificate designator
ATA 2133

Part: OUTFLOW VALVE — INOPERATIVE (AFT FUSELAGE) · airframe 34,843 hrs · 29,625 cycles

ON DEPARTURE FROM CVG, A/C FAILED TO PRESSURIZE LEVELED OFF AT 9,000 FT AND RETURNED TO CVG. INSPECTED DOOR SEALS AND A/C BAYS, ALL CHECKS OK. FOUND OUTFLOW VLV NOT WORKING PROPERLY. REPLACED OUTFLOW VLV, PRESSURIZED A/C TO 6 PSID, RAN PRESS CK PER MM, ALL CHECKS OK.

Source: SDR DL73E001014
WARNING INDICATION · 2000-05-20 Matched by certificate designator
ATA 2131

Part: CONTROLLER — FAILED (CABIN PRESSURE) · airframe 34,821 hrs · 29,606 cycles

LOSS OF CABIN PRESSURIZATION AT 35,000 FT. RAN CHECK LIST. COULD MANUALLY CONTROL CABIN AT 10,000 FT. REPLACED PRESSURE CONTROLLER PER M/M, CHECKS OK PER M/M.

Source: SDR DL73E000990

1999

OTHER · 1999-08-24 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (BS 332)

FUSELAGE SKIN ASSY R1 DOOR CUTOUT LOWER AFT CORNER CRACK REPAIR. A .25 LONG TYPICAL CRACK WAS FOUND IN THE SKIN AND BONDED DOUBLER AT THE LOWER AFT CORNER OF THE R1 DOOR CUTOUT. THE UNDERLYING BEAR STRAP WAS NOT DAMAGED. THE CRACK WAS ROUTED OUT OF THE SKIN AND REPAIRED WITH AND EXTERNAL ALUMINUM DOUBLER AND TRIPLER PER ER/A 368091-14, REV A.

Source: SDR DL73E991906
NO WARNING INDICATION · 1999-07-07 Matched by certificate designator
ATA 5270

Part: WIRE — FAILED (P5 PANEL)

FOUND WIRING TO DOOR WARNING MODULE ON P5 PANEL SHORTING ON HYD PUMP CONTROL PANEL. REPAIRED WIRING AND REPLACED HYD PUMP CONTROL PANEL.

Source: SDR DL73E991529

1998

NO TEST · 1998-08-29 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

MID AISLE EMERGENCY LIGHTS INOP. REPLACED BATTERY PACK.

Source: SDR DL73E981791
NO TEST · 1998-06-30 Matched by certificate designator
ATA 3350

Part: BULB — FAILED (CABIN)

LT WING EMERGENCY LIGHT INOP. REPLAMPED.

Source: SDR DL73E981369

1997

FLUID LOSS; WARNING INDICATION · 1997-06-11 Matched by certificate designator
ATA 7314

Part: FUEL PUMP PLUG — LOOSE (NR 1 ENGINE)

FUEL LEAK ON NUMBER ONE ENGINE. FOUND TEST PLUG ON FUEL PUMP FILTER HOUSING BACKED OUT. SECURED, SAFTIED SYSTEM LEAK CKS GOOD.

Source: SDR DL73E971122
OVER TEMP; WARNING INDICATION · 1997-04-25 Matched by certificate designator
ATA 3020

Part: DUCT — RUPTURED (NR 1 ENGINE)

NR 1 ENG OVERHEAT LIGHT CAME ON AT 1200 MSL, ALL ENG IND NORMAL. WHEN THROTTLE RETARDED LIGHT WENT OUT. FOUND DUCT TO NOSE COWL A/I VLV RUPTURED.

Source: SDR DL73E970766

1996

OTHER · 1996-10-22 Matched by certificate designator
ATA 5312

Part: BULKHEAD — CRACKED (BS 178)

DURING INSPECTION PER SI 3-69482-12, STATION 178 BULKHEAD WAS FOUND CRACKED IN SEVERAL LOCATIONS. REPAIR ACCOMPLISHED PER ERA 304293-14 REV B. THE BULKHEAD WEB IS FABRICATED FROM 0.032 CLAD 2024-T3.

Source: SDR DL73E962457

1995

SMOKE/FUMES/ODORS/SPARKS · 1995-07-13 Matched by certificate designator
ATA 2170

Part: COALESCER BAG — DIRTY (AFT GALLEY)

ON TAKEOFF, HAD SMOKE OF UNKNOWN ORIGIN REPORTED FROM AFT GALLEY THROUGH 1000 FT ON CLIMB. SECURED PACKS, SMOKE ODOR STOPPED. FLIGHT RETURNED TO SLC. RAN ENGINES AT POWER, FOUND ONLY CONDENSATION COMING FROM VENTS. REPLACED COALESCER BAGS, RETURNED TO SERVICE.

Source: SDR DL73E953086
OTHER · 1995-04-12 Matched by certificate designator
ATA 5240

Part: SKIN — CRACKED (R 1 DOOR)

FOUND DURING LETTER CHECK INSP, R-1 DOOR UPPER HINGE HAS CRACK FROM CUTOUT TO DRAIN HOLE. REPAIRED PER SRM 52-00-3.

Source: SDR DL73E951532