Maintenance disclosures
AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. FOUND CORROSION ON RT AFT DOOR SILL. REQUIRES TO BE EVALUATED IAW SRM 53-41-14 REV 49. CORROSION WAS REMOVED AND REPAIR WAS PERFORMED ON DOOR SILL AT FR. 68 IAW SRM 53-41-14 REV 49. MX ACTION IS ACCEPTABLE.
AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. FOUND CRACK ON LT SHEAR PLATE AFT WET AREA AND REQUIRES REPLACEMENT IAW SRM 51-72-11 REV 49. PERFORMED REPLACEMENT OF LT SHEAR PLATE IAW SRM 51-72-11 REV 49. MX ACTION IS ACCEPTABLE.
AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. FOUND CRACK ON RH SHEAR PLATE AFT WET AREA AND REQUIRES REPLACEMENT IAW SRM 51-72-11 REV 49. PERFORMED REPLACEMENT OF RT SHEAR PLATE IAW SRM 51-72-11 REV 49. MX ACTION IS ACCEPTABLE.
REFERENCE NR 5001330681-0010. AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING EPSU BATTERIES CAPACITY TEST, EPSU BATTERY (10WL) FAILED. REPLACEMENT IS REQUIRED IAW AMM 33-51-38-000/400-002-A REV.98. REPLACED EPSU BATTERY (10WL) IAW AMM 33-51-38-000/400-002-A REV.98 P/N OFF: 3214-31, S/N OFF: 904164 / P/N ON: 3214-31, S/N ON: 954030 B/N: 7594. MX ACTION IS ACCEPTABLE.
REFERENCE NR 5001330687-0010. AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING EPSU BATTERIES CAPACITY TEST, EPSU BATTERY (11WL) FAILED. REPLACEMENT IS REQUIRED IAW AMM 33-51-38-000-002-A REV.98. REPLACED EPSU BATTERY (11WL) IAW AMM 33-51-38-400-002-A REV.98 P/N OFF: 3214-31, S/N OFF: 884584 / P/N ON: 3214-31, S/N ON: 954032 B/N: 7596. MX ACTION IS ACCEPTABLE.
REFERENCE NR 5001330695-0010. AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING EPSU BATTERIES CAPACITY TEST, EPSU BATTERY (13WL) FAILED. REPLACEMENT IS REQUIRED IAW AMM 33-51-38-000-002-A REV.98. REPLACED EPSU BATTERY (13WL) IAW AMM 33-51-38-400-002-A REV.98 P/N OFF: 3214-31, S/N OFF: 929867 / P/N ON: 3214-31, S/N ON: 954040 B/N: 7583. MX ACTION IS ACCEPTABLE.
REFERENCE NR 5001330691-0010. AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING EPSU BATTERIES CAPACITY TEST, EPSU BATTERY (12WL) FAILED. REPLACEMENT IS REQUIRED IAW AMM 33-51-38-000-002-A REV.98. REPLACED EPSU BATTERY (12WL) IAW AMM 33-51-38-400-002-A REV.98 P/N OFF: 3214-31, S/N OFF: 910158 / P/N ON: 3214-31, S/N ON: 954024 B/N: 7564. MX ACTION IS ACCEPTABLE.
REF LP442391-1. BATTERY EPSU (EMERGENCY LIGHTING POWER SUPPLY) 10WL FAULTED DURING A SCHEDULED MAINTENANCE CHECK. CORRECTIVE ACTION: PERFORMED OPERATIONAL CHECK AND BITE CHECK OF EPSU PER TSM 33-51-00-810-822-A. TESTS AND BITE CHECKS WERE GOOD. NO FAULTS NOTED. A/C READY FOR CONTINUED SERVICE.
RAD NAV PAGE BLANK AND ACFT DIDN'T CAPTURE THE ILS SIGNAL. FOUND RMP 1&2 STYBY NAV SWITCH SELECTED. PLACED RMP'S TO NORMAL CONFIG. PERFORMED AFS TEST, TEST OK NO DEFECTS FOUND. ACFT OK FOR SERVICE. AMM 22-96-00-710-001A