6 reports on file, 2024-08-15 – 2026-10-01.
Part: DOOR SILL — CORRODED (ZONE 200) · corrosion level 2 · airframe 17,152 hrs · 8,228 cycles
AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING INSPECTION OF THE AFT CABIN FLOOR STRUCTURE FOUND CORROSION R2 DOORSILL BEAM FR-68. PERFORMED REPLACEMENT OF R2 DOOR SILL IAW-SRM-53-41-14-300-001 REV 50. /END/
Part: DOOR SILL — CORRODED (ZONE 200) · corrosion level 2 · airframe 17,152 hrs · 8,228 cycles
AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING INSPECTION OF THE AFT CABIN FLOOR STRUCTURE FOUND CORROSION R2 DOORSILL BEAM FR-68. PERFORMED REPLACEMENT OF R2 DOOR SILL IAW-SRM-53-41-14-300-001 REV 50.
Part: POWER SUPPLY — FAILED (ZONE 200) · airframe 15,621 hrs · 7,442 cycles
REFERENCE LP702388 #1 EPSU BATTERY (13WL) AFT L FAILED TEST FAILED EPSU SYS TEST. AC WAS NOT GROUNDED AS A RESULT OF THIS SDR REPORTABLE EVENT, IT WAS A RON SCHEDULED HEAVY CHECK. REMOVED AND REPLACED EPSU BATTERY (13WL) IAW AMM 33-51-38-000/400-002-A. OPS CHECK GOOD. AC OK FOR SERVICE.
Part: POWER SUPPLY — FAILED (ZONE 200) · airframe 15,621 hrs · 7,442 cycles
REFERENCE LP702387 #3 EPSU BATTERY (11WL) EMERG L FAILED TEST FAILED EPSU SYS TEST. AC WAS NOT GROUNDED AS A RESULT OF THIS SDR REPORTABLE EVENT, IT WAS A RON SCHEDULED HEAVY CHECK. REMOVED AND REPLACED EPSU BATTERY (11WL) IAW AMM 33-51-38-000/400-002-A. OPS CHECK GOOD. AC OK FOR SERVICE. /END/.
Part: POWER SUPPLY — FAILED (ZONE 200) · airframe 15,621 hrs · 7,442 cycles
REFERENCE LP702387 #2 EPSU BATTERY (10WL) FWD L FAILED TEST FAILED EPSU SYS TEST. AC WAS NOT GROUNDED AS A RESULT OF THIS SDR REPORTABLE EVENT, IT WAS A RON SCHEDULED HEAVY CHECK. REMOVED AND REPLACED EPSU BATTERY (10WL) IAW AMM 33-51-38-000/400-002-A. OPS CHECK GOOD. AC OK FOR SERVICE.
Part: SEAL — LEAKING (BLEED DUCT) · airframe 11,514 hrs · 5,335 cycles
DISCREPANCY: REFERENCE LP 448414 AFTER TAKEOFF, WE GOT A FIRE INDICATION ON THE #2 ENGINE. AC WAS GROUNDED AS A RESULT OF THIS EVENT. ALL INDICATIONS WERE NORMAL, WE FOLLOWED ECAM AND SHUT DOWN #2 ENGINE. THE FLIGHT CREW DID NOT ACTIVATE THE EXTINGUISHING BOTTLES. AIRCRAFT RETURNED TO THE AIRPORT. CORRECTIVE ACTION: PERFORMED ENGINE #2 INSPECTION AND FOUND NO EVIDENCE OF FIRE. NO FUEL LEAKS FROM FUEL NOZZLES OR FUEL LINE "B" NUTS. FOUND BLEED LEAK AT THE TBV DUCT TO COMBUSTION CASE SEAL. REMOVED AND REPLACED TBV DUCT SEAL./END/