N390UP
Registered owner: UNITED PARCEL SERVICE CO, KY (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
2 reports on file, 2025-07-10 – 2026-10-22.
Part: WIRE — DAMAGED (ZONE 100) · airframe 2,981 hrs · 1,226 cycles
PAN PAN DECLARED AT FL370, FLAP INDICATOR SHOWED 1/2. EICAS SLAT DISAGREE, LE LIGHT, FLAP HANDLE IN UP. RAN CHECKLIST, LANDED NON-NORMAL @ FLAPS 20. FLAPS APPEARED TO OPERATE NORMALLY THRU FLAP 20 FOR LANDING. INSPECTED SENSOR AND SPLICES FOR S278- SPLICE CONDITION WAS QUESTIONABLE. RE-SPLICED PER SWPM 20-30-12 7.G AND 7.H. SYSTEM TESTS NORMAL PER AMM TASK 27-88-01-722-028; AMM TASK 32-09-13-765-801 AND AMM TASK 27-88-01-200-801. CHECKED FOR UNLOCKED PINS ON RACK CONNECTOR- REF AMM 32-09-04/401. NO DEFECTS NOTED. AIRCRAFT OKAY FOR CONTINUED SERVICE.
Part: PACKING — LEAKING (HYD SYSTEM) · airframe 70 hrs · 37 cycles
C HYD QTY EICAS DECREASING RESERVIOR QTY. OBSERVED UPON DESCENT AND ARRIVAL C HYD PRESS EICAS QRH PROCEDURES FOLLOWED INCLUDING ALT FLAP AND GEAT EXTENSION. FOUND PRESSURE OUTLET UNION PACKING DAMAGED/TORN. REPLACED PACKING AND UNION IAW AMM 29-11-19 AND AMM 20-11-00. CLEANED THE AREA IAW AMM 12-25-01. C/OUT OPS CHK OF CENTER HYD SYS IAW AMM 29-11-00, OPS CHK SATISFACTORY. C/OUT CENTER SYS EXTERNAL LEAK CHK IAW AMM 29-11-00, NO LEAK FOUND. SATISFACTORY. A/C OK FOR SERVICE.