N402NV

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

67 reports on file, 2008-09-28 – 2017-12-08.

INADEQUATE Q C · 2017-12-08 Matched by certificate designator
ATA 5330

Part: SKIN — GOUGED (BS 1207-1217) · airframe 68,612 hrs · 43,805 cycles

AFT CARGO DOOR CUTOUT DAMAGED FROM BAGGAGE LOADER. REPAIRED DAMAGE IAW AAR EA NO. 16774

Source: SDR JR2R201712080031
OTHER · 2017-09-14 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (FUSELAGE) · corrosion level 2 · airframe 68,414 hrs · 43,703 cycles

AFT LAV DOOR CUTOUT HAS CORROSION ON FWD LWR CORNER. REPAIRED SKIN IAW EA 30-2017-125.

Source: SDR JR2R20170914074
OTHER · 2017-09-14 Matched by certificate designator
ATA 5310

Part: FORMER — CORRODED (BS 1446) · corrosion level 2 · airframe 68,414 hrs · 43,703 cycles

AFT ACCESSORY BAY FORMER ON CANTED FRAME CORRODED. REPAIRED THE FORMER IAW SRM 53-03, FIG 3.

Source: SDR JR2R20170914138
OTHER · 2017-09-11 Matched by certificate designator
ATA 5320

Part: WEB — CRACKED (FUSELAGE) · airframe 68,414 hrs · 43,703 cycles

AFT ACCESSORY COMPARTMENT CANTED FRAME WEB SUPPORT CRACKED RT SIDE BETWEEN STA 1463 AND STA 1474.

Source: SDR JR2R20170911044
Earlier reports · 2008–2016 · 63 reports

2016

WARNING INDICATION · 2016-07-18 Matched by certificate designator
ATA 7920

Part: RELIEF VALVE — FAILED (RT ENGINE) · airframe 66,414 hrs · 42,706 cycles

EMERGENCY DECLARED, AFTER TAKEOFF, OIL PRESSURE CLIMBED ABOVE 55 PSI REACHING A PSI OF 80, FOLLOWED EMERGENCY QRH PROCEDURES. REPLACED NR 2 ENGINE OIL PRESSURE REGULATOR OPS AND LEAK CHECKS GOOD IAW MM 79-20-03-2-0. REMOVED & REPLACED NR 2 ENGINE OIL PRESSURE RELIEF VALVE REF AMM 79-20-03-02 SEE LP 703073 FOR LEAK & OPS CHECK .

Source: SDR WX0A2016072273178
OTHER · 2016-03-10 Matched by certificate designator
ATA 2810

Part: FUEL TANK — CRACKED (ZONE 100) · airframe 65,884 hrs · 42,426 cycles

AFT AUX FUEL TANK CRACKED AT UPPER SKIN STIFFENER, NR 1 STRINGER, AFT END. REPAIR WAS ACCOMPLISHED IAW SRM 53-05 FIGURE 46 UNDER WO 1012616-1600 0091 & WO 00283925 M301 NR 374.

Source: SDR JR2R03102016374
OTHER · 2016-03-10 Matched by certificate designator
ATA 5320

Part: STIFFENER — CRACKED (FUSELAGE) · airframe 65,884 hrs · 42,426 cycles

CRACKED UPPER SKIN STIFFENER, STRINGER NR 1, ON AFT END OF AUXILIARY TANK IN AFT CARGO. REPAIRED IAW SRM 53-05 FIG 46.

Source: SDR WX0A2016031473102
NO TEST · 2016-01-18 Matched by certificate designator
ATA 2560

Part: BATTERY — DISCHARGED (FLASHLIGHT) · airframe 65,747 hrs · 42,361 cycles

AFT EMER FLASHLIGHT INOPERATIVE. R & R AFT EMER FLASHLIGHT BATTERY IAW AMM 25-60-00. OPERATIONS CHECKED GOOD.

Source: SDR WX0A2016012173072

2015

NO TEST · 2015-12-04 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

R1 OVERHEAD EMER LIGHT, ONE LIGHT INOPERATIVE. R & R BULB IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.

Source: SDR WX0A2015120873028
FLUID LOSS; SMOKE/FUMES/ODORS/SPARKS · 2015-10-15 Matched by certificate designator
ATA 4920

Part: APU — LEAKING (APU BAY) · airframe 65,365 hrs · 42,163 cycles

AFTER THE DOOR WAS SHUT & THE PUSH CLEARANCE WAS RECEIVED, THE FLIGHT ATTENDANTS CALLED FWD SAYING THAT THERE WAS SMOKE IN THE CABIN. THE CREW CANCELLED THE PUSH CLEARANCE & HAD THE RAMP CREW PULL THE JET BRIDGE BACK UP TO THE AIRCRAFT. ONCE THE COCKPIT DOOR WAS OPENED THE CAPTAIN NOTED THAT THERE WAS VISIBLE SMOKE IN THE CABIN, BUT HE COULD STILL SEE ALL THE WAY TO THE BACK OF THE CABIN. THE APU WAS TURNED OFF & EXTERNAL AIR WAS HOOKED UP. PERFORMED TASK CARD 21-059-002, FOUND APU LEAKING OIL INTO COMBUSTION CHAMBER & INTO INLET. PERFORMED TASK CARD 21-059-008, PACK BURNOUT NO SMOKE OR SMELL NOTED. R & R COALESCER BAGS IAW MM 21-20-02.

Source: SDR WX0A2015101572945
NO TEST · 2015-10-02 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 65,344 hrs · 42,150 cycles

EMERGENCY STANDBY LIGHTS INOPERATIVE AT ROWS 19 & 15. R & R BATTERY PACK B5-72. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.

Source: SDR WX0A2015100572921
NO TEST · 2015-09-13 Matched by certificate designator
ATA 2560

Part: BATTERY — DISCHARGED (FLASHLIGHT) · airframe 65,304 hrs · 42,128 cycles

ONE FWD & ONE AFT FLIGHT ATTENDANT FLASHLIGHT NOT BLINKING. REPLACED BATTERIES FOR ONE FWD & ONE AFT FLIGHT ATTENDANT FLASHLIGHTS IAW AMM 25-60-00. OPERATIONS CHECKED NORMAL.

Source: SDR WX0A2015091472861
NO TEST · 2015-09-10 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (TAIL CONE) · airframe 65,292 hrs · 42,124 cycles

FOUND ON WAKE UP, TAIL CONE EMER LIGHT INOPERATIVE & ALL THREE TAIL CONE LIGHTS VERY DIM. REPLACED BOTH POWER SUPPLIES & ONE EMER EXIT IDENTIFIER LIGHT ASSEMBLY. OPERATIONS CHECKED GOOD IAW AMM 33-53-00 & 33-53-01.

Source: SDR WX0A2015091472858
SMOKE/FUMES/ODORS/SPARKS · 2015-07-14 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR · airframe 65,006 hrs · 41,985 cycles

ACFT AIR CONDITIONING SYS SMELLS LIKE PROPANE ON CLIMB OUT, STOPS AT CRUISE. COMPLIED WITH ODOR & SMOKE TROUBLESHOOTING IAW TC 21-059-002, NO DEFECTS NOTED.

Source: SDR WX0A2015072072741
WARNING INDICATION · 2015-06-24 Matched by certificate designator
ATA 4950

Part: CLAMP — DEFECTIVE (APU) · airframe 64,909 hrs · 41,939 cycles

TAIL COMPARTMENT HIGH ON CLIMB OUT. FOLLOWED QRH PROCEDURE 21.4 RETURNED TO FIELD. REF LOG PAGE 553713 FOR TROUBLESHOOTING & WORK ORDER 260063. FOUND LEAK FROM AFT APU LOAD CONTROL VLV. R & R CLAMP IAW AMM 20-10-11. OPERATIONS & LEAK CHECKED GOOD.

Source: SDR WX0A2015062672697
FALSE WARNING · 2015-06-21 Matched by certificate designator
ATA 3697

Part: CONNECTOR — DIRTY (AC BAY)

AFTER TAKEOFF WITH APU RUNNING, TAIL COMPARTMENT TEMP HIGH MASTER CAUTION ILLUMINATED. COMPLIED WITH THE QRH PROCEDURE 21.4 & THE WARNING EXTINGUISHED AFTER TURNING BOTH AC SUPPLY SWITCHES TO HP BLEED, AT 10,000 FT APU WAS SHUT DOWN. FLIGHT CONTINUED AS DIRECTED BY QRH. CHECKED TAIL COMPARTMENT FOR LEAKS, NO MAJOR LEAKS FOUND. CLEANED TAIL COMPARTMENT TEMP SENSOR CONNECTORS, RAN APU FOR 10 MINS, LIGHT REMAINED EXTINGUISHED IAW AMM 36-20-02. OK TO CONTINUE.

Source: SDR WX0A2015062272681
FALSE WARNING · 2015-04-10 Matched by certificate designator
ATA 2613

Part: SENSOR — DIRTY (AC BAY) · airframe 64,546 hrs · 41,762 cycles

TAIL COMPARTMENT TEMP HIGH LIGHT CAME ON AT 14000' ON CLIMB OUT. LIGHT WENT OUT AFTER RT ENG POWER WAS REDUCED TO 1.3 EPR, AFTER 2 MINUTES POWER WAS INCREASED & LIGHT DID NOT RETURN. INSPECTED TAIL SECTION PNEUMATIC DUCTING & VLVS, NO DEFECTS NOTED, REF AMM 36-00-00. INSPECTED TAIL COMPARTMENT HEAT STRIPS FOR OVERHEAT CONDITION, NO OVERHEAT INDICATED. CHECKED & CLEANED LT & RT OVERHEAT SENSORS. OPERATIONS CHECKED OK IAW AMM 36-20-02. REF LOG PAGE 560141 FOR CORRECTIVE ACTION. NEW DUCT BOOTS INSTALLED ON TEMP CONTROL VLV DUCT.

Source: SDR WX0A2015041472535

2014

OTHER · 2014-12-06 Matched by certificate designator
ATA 2230

Part: AUTOTHROTTLE SYS — MALFUNCTIONED (COCKPIT) · airframe 63,819 hrs · 41,406 cycles

ON TAKEOFF, AUTO THROTTLES ENGAGED NORMALLY. DID NOT GET CLAMP AT 90KTS, THROTTLES WENT IDLE. ABORTED THE TAKEOFF, PLACED AUTO THROTTLES ON MEL 22-15 SIT 19. DMI 12765 PLACARDS INSTALLED.

Source: SDR WX0A2014120972299
NO TEST · 2014-10-23 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 63,612 hrs · 41,314 cycles

FOUND ON WAKE UP PORTABLE EMER BATTERY LIGHT INOPERATIVE & WILL NOT REMOVE. R & R PORTABLE EMER BATTERY PACK IAW AMM 33-53-00. LIGHTS OPERATE NORMAL.

Source: SDR WX0A2014102672224
OTHER · 2014-09-24 Matched by certificate designator
ATA 2740

Part: JACKSCREW — WORN (HORIZ STAB) · airframe 63,478 hrs · 41,253 cycles

WHILE COMPLYING WITH AD 2000-15-15- HORIZONTAL STAB JACKSCREW WEAR INSPECTION. JACK B FAILS FREE PLAY MEASUREMENT. MEASURES .013 LIMIT IS .010. CHECKED 3 TIMES IAW TASK CARD. REQUIRES JACKSCREW REPLACEMENT. R & R HORIZONTAL STAB JACKSCREW. OPERATIONS CHECKED GOOD IAW AMM 27-40-01. SEE LP 527853 FOR JACK B INSPECTION OF NEW ACME SCREW ASSEMBLY.

Source: SDR WX0A2014092672171
NO TEST · 2014-09-11 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (TAIL CONE) · airframe 63,425 hrs · 41,229 cycles

AFT TAIL CONE EMER LIGHTS INOPERATIVE. R & R EMER BATTERY POWER SUPPLY IAW AMM 33-53-01. SYS OPERATIONS NORMAL.

Source: SDR WX0A2014091772158
NO TEST · 2014-08-27 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 63,377 hrs · 41,207 cycles

TUNNEL SIDEWALL EMER LIGHTS INOPERATIVE. IAW LP 540887 FOR CORRECTIVE ACTION, EMER LIGHTS OPERATIONS CHECKED GOOD IAW AMM 33-53-01. NO FURTHER ACTION REQUIRED.

Source: SDR WX0A2014090372127
NO TEST · 2014-08-27 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 63,377 hrs · 41,207 cycles

TUNNEL OVERHEAD EMER LIGHTS INOPERATIVE. REPLACED BATTERIES AT B5-25. OPERATIONS CHECKED GOOD IAW AMM 35-53-01.

Source: SDR WX0A2014090372124
NO TEST · 2014-08-27 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (TAIL CONE) · airframe 63,377 hrs · 41,207 cycles

THREE TAIL CONE LIGHTS INOPERATIVE. REPLACED POWER SUPPLY & BATTERIES. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.

Source: SDR WX0A2014090372123
NO TEST · 2014-08-27 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 63,377 hrs · 41,207 cycles

AFT ENTRY DOOR EXIT MARKER LIGHTS INOPERATIVE. R & R AFT ENTRY DOOR EXIT IDENTIFIER LIGHT ASSEMBLY IAW AMM 33-53-01. OPERATIONS CHECKED GOOD.

Source: SDR WX0A2014090372125
NO TEST · 2014-08-27 Matched by certificate designator
ATA 3397

Part: WIRE — FAULTY (CABIN) · airframe 63,377 hrs · 41,207 cycles

L2 DOOR EXIT MARKER LIGHTS INOPERATIVE. R & R EMER BATTERY PACK & PWR SUPPLY B5-107 IAW AMM 33-53-00, NO FIX. TROUBLE SHOT, FOUND WIRE L982D14 CONNECTED AT B5-209, THIS IS A DELETE WIRE FROM AIM DWG AA 10625 & IS CONNECTED TO GND WIRE L982D14 COIL & STOW IAW SWPM 20-10-04. EMER LIGHTS OPERATIONS CHECKED GOOD IAW AMM 33-53-01.

Source: SDR WX0A2014090372126
OTHER · 2014-08-14 Matched by certificate designator
ATA 2150

Part: FLEX COUPLING — OUT OF POSITION (AC BAY)

ON CLIMB OUT AT 12-15, NOTED FLOW LIGHT & CLIMBING CABIN. UNABLE TO MAINTAIN CABIN PRESS. BOTH PRESS CONT INOPERATIVE, UNPRESSURIZED FLT. REF LP 515938 RT PACK ON MEL 21-08 SIT 2, CONTROL 10838, RT PACK MEL CLEARED ON LP 515943. FLEX COUPLING OFF BETWEEN LT ACM COMPRESSOR & PRIMARY HEAT EXCHANGER. INSPECTED ACM FOR DAMAGE, NONE NOTED. INSTALLED FLEX COUPLING & NEW CLAMP. OPERATIONS TESTED OF LT PACK SYS GOOD IAW AMM 21-51-01. PRESSURIZED ACFT IAW TASK CARD FO443601. OPERATIONS CHECKED GOOD. PERFORMED BIT TEST OF PRESS CONTROLLERS IAW AMM 21-32-03. FAULT SHOWS ACFT MOTOR. R & R OUTFLOW VLV ACTUATOR. OPERATIONS CHECK & BIT CHECKED GOOD IAW AMM 21-32-05.

Source: SDR WX0A2014082272111
OTHER · 2014-08-08 Matched by certificate designator
ATA 5320

Part: CUSP WEB — CORRODED (FUSELAGE)

RIGHT CABIN AT STATION 1060 RBL 55 CUSP WEB IS CORRODED. TRIMMED OUT CORRODED AREA. INSTALLED FILLER & DOUBLER IAW SRM 5.

Source: SDR WX0A2014081172082
OTHER · 2014-08-05 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE)

CORROSION ON RT FLOORBEAM STATION 1309. REPAIRED FLOORBEAM IAW EA 25-2014-236 DATED 8/4/2014.

Source: SDR WX0A2014080772079
OTHER · 2014-08-03 Matched by certificate designator
ATA 5320

Part: CUSP WEB — CORRODED (FUSELAGE)

RIGHT CABIN AT STATION 1060 RBL 55 CUSP WEB IS CORRODED. TRIMMED OUT CORRODED AREA, INSTALLED FILLER & DOUBLER IAW SRM 53-05 FIG 131A-10. WORK ACCOMPLISHED ON WORK ORDER 1011048-2400-0147.

Source: SDR WX0A2014080572063
OTHER · 2014-08-01 Matched by certificate designator
ATA 5320

Part: MEMBRANE — CORRODED (FUSELAGE)

R1 DOOR FLOOR WEB IS CORRODED FROM STATION 177 TO 180 RBL 44 TO 54. R & R WEB IAW DWG 9936534. WORK ACCOMPLISHED ON WORK ORDER 1011048-2400-0139 M301 ITEM 332.

Source: SDR WX0A2014080572060
OTHER · 2014-08-01 Matched by certificate designator
ATA 5320

Part: MEMBRANE — CORRODED (FUSELAGE)

R1 DOOR FLOOR WEB IS CORRODED FROM STATION 180 TO 200 RBL 44 TO 54. REPAIRED CUSP WEB IAW SRM 51-70-4 FIG 2. WORK ACCOMPLISHED ON WORK ORDER 1011048-2400-0138 M301 ITEM 331.

Source: SDR WX0A2014080572059
NO TEST · 2014-07-18 Matched by certificate designator
ATA 2560

Part: BATTERY — DISCHARGED (DEFIBRILLATOR)

FORWARD DEFRIB BATTERY DEAD & PAD INTERMITTENTLY INOPERATIVE. R & R FWD DEFRIB AT BATTERY IAW MM25-60-01.

Source: SDR WX0A2014072272039
NO TEST · 2014-07-16 Matched by certificate designator
ATA 2560

Part: FLASHLIGHT — INOPERATIVE (CABIN)

FWD EMER FLASH LIGHT INOPERATIVE. R & R EMER FLASHLIGHT IAW AMM 25-60-00.

Source: SDR WX0A2014071872034
ENGINE STOPPAGE · 2014-06-09 Matched by certificate designator
ATA 7200

Part: ENGINE — FAILED (RIGHT)

RIGHT ENG FAILED AFTER TAKEOFF, ACFT RETURNED TO IAG. ENG CHANGE IN PROGRESS, ADDITIONAL INFO TO BE SUBMITTED AS IT BECOMES AVAILABLE.

Source: SDR WX0A071980

2013

NO TEST · 2013-12-03 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN)

OVERHEAD EMERGENCY LIGHT SEAT ROW 23 INOPERATIVE. REPLACED ROW 23 BATTERIES IAW AMM 33-53-01, OPERATIONS CHECKED GOOD.

Source: SDR WX0A071768
NO TEST · 2013-09-11 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHTS)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACK IAW AMM 33-50-00, SYS OPS CHECKED NORMAL. ACFT RETURNED TO SERVICE.

Source: SDR WX0A201309260003
NO TEST · 2013-07-25 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHTS)

DURING A ROUTINE OVERNIGHT SERVICE CHECK, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACK AND OPS CHECK WAS ACCOMPLISHED IAW AMM 33-50-00, SYS OPS CHECKED NORMAL. ACFT RETURNED TO SERVICE.

Source: SDR WX0A2013080100641
OTHER · 2013-05-16 Matched by certificate designator
ATA 5312

Part: BULKHEAD — CRACKED (FUSELAGE)

CRACKS FOUND ON FWD & AFT SIDES OF CANTED BULKHEAD WEB AT STA 1463 BETWEEN L9 & L11. ADDITIONALLY FOUND CRACK IN LOUVER CLIPS AT STA 1463 AFT OF WEB AND ANGLES / WEB STIFFENERS ON AFT FACE OF WEB. REPLACED PARTS - WEBS P/N'S 9953015-57 & 9953015-37, SRM P/N 9911839-2091-5, LOWER CLIPS P/N'S 9911839-183, 9911839-185 & 9911839-187, ANGLES/WEB P/N'S 9911839-145, 9911839-29 & 9911839-31.

Source: SDR WX0A071586
OTHER · 2013-02-06 Matched by certificate designator
ATA 5210

Part: STRUCTURE — CRACKED (L1 DOOR)

L-1 DOOR FWD UPPER AREA 3 INCH CRACK ADJACENT TO UPPER STOP PAD FITTING. STOP DRILLED CRACK, FABRICATED, LOCATED, DRILLED AND INSTALLED PAD SEGMENT DOUBLER.

Source: SDR WX0A071513
OTHER · 2013-02-05 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (FUSELAGE)

LEFT O/B CABIN SEAT TRACK CORRODED AT STATION 1200 LBL 44. REMOVED DAMAGED AREA OF SEAT TRACK, LOCATED, DRILLED AND INSTALLED REPLACEMENT SEAT TRACK AND SPLICE.

Source: SDR WX0A071512
OTHER · 2013-02-02 Matched by certificate designator
ATA 5523

Part: TAB — DAMAGED (LT ELEVATOR)

LEFT ELEVATOR CONTROL TAB LIGHTNING STRIKE DAMAGE ON TRAILING EDGE 36 INCHES FROM O/B END. REMOVED DAMAGED AND PREPPED FOR BONDING. FABRICATED REPAIR DOUBLER AND BONDED.

Source: SDR WX0A071511
OTHER · 2013-01-30 Matched by certificate designator
ATA 5311

Part: FRAME — CRACKED (FUSELAGE)

CANTED FRAME STATION 1474 CRACKED AT LONGERON 18L. VERIFIED STOP DRILL CRACK. FABRICATED DOUBLERS, LOCATED, DRILLED AND INSTALLED.

Source: SDR WX0A071502
OTHER · 2013-01-22 Matched by certificate designator
ATA 5753

Part: DOUBLER — CHAFED (TE FLAP VANE)

LEFT O/B AFT FLAP I/B VANE L/E CHAFED OUT OF LIMITS ON EXISTING DOUBLER. REMOVED DAMAGED DOUBLER, REMOVED DAMAGED SKIN, PERFORMED WATER EVAC. FABRICATED FILLER AND DOUBLER AND BONDED.

Source: SDR WX0A071493

2012

NO TEST · 2012-10-26 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEM OPERATIONAL CHECK WAS NORMAL. THE AIRCRAFT HAS BEEN RETURNED TO SERVICE.

Source: SDR WX0A071368
NO TEST · 2012-01-17 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEM OPERATIONAL CHECK WAS NORMAL. THE AIRCRAFT HAS BEEN RETURNED TO SERVICE.

Source: SDR WX0A071083
NO TEST · 2012-01-17 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEM OPERATIONAL CHECK WAS NORMAL. THE AIRCRAFT HAS BEEN RETURNED TO SERVICE.

Source: SDR WX0A071084
SMOKE/FUMES/ODORS/SPARKS · 2012-01-13 Matched by certificate designator
ATA 2170

Part: COALESCER BAG — DIRTY (AC BAY)

FLIGHT CREW PERSONNEL REPORTED DURING PUSHBACK APU / RT PACK OPERATING. FA'S REPORTED AN ODOR OF BURNING PLASTIC. MAINTENANCE DEPARTMENT PERSONNEL REMOVED AND REPLACED BOTH COALESCER BAGS IAW AMM 21-20-02, RAN APU FOR SEVERAL MINUTES, NO SMOKE OR ODORS NOTED, AIRCRAFT OK FOR SERVICE.

Source: SDR WX0A071082
NO TEST · 2012-01-06 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEM OPERATIONAL CHECK WAS NORMAL. THE AIRCRAFT HAS BEEN RETURNED TO SERVICE.

Source: SDR WX0A071059

2011

NO TEST · 2011-10-31 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEM OPERATIONAL CHECK WAS NORMAL. THE AIRCRAFT HAS BEEN RETURNED TO SERVICE.

Source: SDR WX0A070989
NO TEST · 2011-10-31 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEM OPERATIONAL CHECK WAS NORMAL. THE AIRCRAFT HAS BEEN RETURNED TO SERVICE.

Source: SDR WX0A070988
OTHER · 2011-09-15 Matched by certificate designator
ATA 5320

Part: CUSP WEB — CRACKED (FUSELAGE)

RT CABIN CUSP WEB CRACKED AND CORRODED AT STA 1287. REMOVED DAMAGED CUSP WEB, FABRICATED CUSP WEB AND DOUBLERS, LOCATED, DRILLED AND INSTALLED IAW MD 80 SRM FIG 96 AND DRG SG09530019.

Source: SDR WX0A070935
OTHER · 2011-09-14 Matched by certificate designator
ATA 5320

Part: CUSP WEB — CORRODED (FUSELAGE)

CABIN LT FLOOR CUSP WEB CORRODED FROM STA 712 TO STA 731. REMOVED DAMAGED AREA, FABRICATED REPAIR DOUBLER, RING DOUBLERS, FILLERS, LOCATED, DRILLED AND INSTALLED IAW DRAWING SG 09530019.

Source: SDR WX0A070934
NO TEST · 2011-05-27 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEM OPERATIONAL CHECK WAS NORMAL. THE AIRCRAFT HAS BEEN RETURNED TO SERVICE.

Source: SDR WX0A070865
NO TEST · 2011-03-29 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEM OPERATIONAL CHECK WAS NORMAL. THE AIRCRAFT HAS BEEN RETURNED TO SERVICE.

Source: SDR WX0A070819
NO TEST · 2011-03-23 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEM OPERATIONAL CHECK WAS NORMAL. THE AIRCRAFT HAS BEEN RETURNED TO SERVICE.

Source: SDR WX0A070806
NO TEST · 2011-02-11 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEM OPERATIONAL CHECK WAS NORMAL. THE AIRCRAFT HAS BEEN RETURNED TO SERVICE.

Source: SDR WX0A070768
NO TEST · 2011-01-28 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEM OPERATIONAL CHECK WAS NORMAL. THE AIRCRAFT HAS BEEN RETURNED TO SERVICE.

Source: SDR WX0A070761
NO TEST · 2011-01-13 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEM OPERATIONAL CHECK WAS NORMAL. THE AIRCRAFT HAS BEEN RETURNED TO SERVICE.

Source: SDR WX0A070731

2010

NO TEST · 2010-04-14 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEM OPERATIONAL CHECK WAS NORMAL. THE AIRCRAFT HAS BEEN RETURNED TO SERVICE.

Source: SDR WX0A070556
OTHER · 2010-02-10 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (FUSELAGE)

RT FUSELAGE SKIN (RT LOWER WING SKIN) HAS CORROSION AT STA 845, STA 29R. BLENDED CORROSION FOUND OUT OF LIMITS, INSTALLED DOUBLER REPAIR AT RT LOWER FUSELAGE SKIN STA 845 STA 29R AS PER RES 2002066, 17X17.

Source: SDR WX0A070525
OTHER · 2010-02-10 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (FUSELAGE)

FUSELAGE SKIN HAS CORROSION AT STA 864 RBL 0 TO 20, RT WING CENTER SECTION. BLENDED CORROSION FOUND SKIN OUT OF LIMITS, INSTALLED DOUBLER REPAIR AT RT FUSELAGE SKIN STA 864 RBL 0 TO 20 AS PER RES 2002066-4, 19X5.

Source: SDR WX0A070524
OTHER · 2010-02-10 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (FUSELAGE)

WING CENTER SECTION LOWER SKIN RT HAS CORROSION STA 905 RBL 22 TO 52. BLENDED CORROSION, FOUND SKIN OUT OF LIMITS, INSTALLED REPAIR DOUBLER AT RT WING CENTER LOWER SKIN STA 905 FROM RBL 17 TO 56 (RT FUSELAGE SKIN) AS PER RES 2002066-10.

Source: SDR WX0A070526

2009

NO TEST · 2009-08-27 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00. THE AIRCRAFT HAS RETURNED TO SERVICE.

Source: SDR WX0A070392
OTHER · 2009-07-16 Unresolved
ATA 2780

Part: PULLEY — MIGRATED (SLATS)

DURING SCHEDULED INSP FOUND RT WING L/E CAVITY, (2) PULLEYS MIGRATED WITH NO GAP BETWEEN EACH PULLEY AFT OF NR 0, SLAT INBD AND OTBD SLAT TRACK.

Source: SDR DU4R2009382

2008

NO TEST · 2008-10-15 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

L1 DOOR EMERGENCY LIGHT - DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REPLACED THE EMERGENCY LIGHT ASSEMBLY AS REQUIRED. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00. THE AIRCRAFT HAS RETURNED TO SERVICE.

Source: SDR WX0A070245
NO TEST · 2008-09-28 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — FAILED (EMERGENCY LIGHTS)

DURING A ROUTINE OVERNIGHT SERVICE CHECK INSP, MAINT REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINT REMOVED AND REPLACED THE APPROPRIATE BATTERIESIN THE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED IAW AMM 33-50-00. THE ACFT HAS RETURNED TO SERVICE. (K)

Source: SDR WX0A070236