N416MA

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

6 reports on file, 1996-09-30 – 2010-03-26.

OTHER · 2010-03-26 Matched by certificate designator
ATA 5312

Part: BULKHEAD — CRACKED (FS 270 BL-9,)

DURING OTHER MX, 2 CRACKS WERE FOUND IN BULKHEAD, PN 222-031-505-001 AT ATTACHMENT POINT OF NODAL BEAM SUPPORT, PN 222-031-519-103.

Source: SDR QMLR3253U
WARNING INDICATION · 2009-12-20 Matched by certificate designator
ATA 7200

Part: ENGINE — FAILED · airframe 11,137 hrs

ENROUTE TO HOSPITAL, WHILE DESCENDING, NOTICED THE TORQUE OF THE NR1 ENG HAD DROPPED TO ZERO. THE NR1 ENG PARAMETERS WERE CONSTANT AT ABOUT 75-80 PERCENT NG AND APPROX 650 DEGREES C MGT. IMMEDIATELY VERIFIED THAT BOTH THROTTLES WERE COMPLETELY OPEN. AS APPLIED PWR WITH COLLECTIVE CONTROL THE NR 2 ENG PARAMETERS BEGUN TO NORMALLY INCREASE WHILE THE NR 1 ENG PARAMETERS REMAINED CONSTANT WITH THE TORQUE STILL AT ZERO. OIL TEMPERATURES AND PRESSURES WERE NORMAL AND NO LIGHTS WERE ILLUMINATED ON THE CWP. NOTIFIED CREW AND DECLARED AN EMERGENCY WITH THE CONTROL TWR OF AIRPORT WAS ALREADY IN CONTACT WITH (KSBD). THE CREW NOTIFIED THE APPROPRIATE COMMUNICATION FACILITIES AND REQUESTED ALTERNATIVE TRANSPORTATION FOR THE PATIENT. EMERGENCY PROCEDURES IAW FLIGHT MANUAL WERE APPLIED WITH THE COOPERATION OF THE CREW. HAVING NO REASONS TO SHUTDOWN THE NR 1 ENG (AS IT WAS APPARENTLY STABILIZED AT A VALUE SLIGHTLY ABOVE THE IDLE POSITION) DECIDED TO PERFORM A RUN ON LANDING ON MAIN TAXIWAY OF AIRPORT WITH BOTH ENGINES RUNNING. LANDING WAS UNEVENTFUL AND NO PARAMETERS WERE EXCEEDED. AFTER LANDING THE PATIENT WAS LOADED TO AN AMBULANCE AND TRANSPORTED BY OUR CREW TO DESTINATION HOSPITAL AND PROPER MANAGEMENT NOTIFIED. AT THIS TIME THE CAUSE OF THE PROBLEM HAS NOT BEEN IDENTIFIED.

Source: SDR QMLA122009049
OTHER · 1997-01-13 Unresolved
ATA 6220

Part: BEARING — WORN EXCESSIVELY (M/R)

PART IS WORN EXCESSIVELY. ELASTORMERIC EXTRUSION, DELAMINATION & SEPERATION. UNIT FIRST PUT INTO SERVICE 08-03 1983.

Source: SDR HAIW6HR0068
OTHER · 1997-01-08 Unresolved
ATA 6220

Part: BEARING — WORN EXCESSIVELY (M/R)

PART IS WORN EXCESSIVELY. ELASTOMERIC MATERIAL IS SEPERATING. BEARING WAS PUT IN SERVICE 14 JUL. 1989. PART HELD FOR FUTURE EVALUATION.

Source: SDR HAIW6HR0067
OTHER · 1996-11-06 Unresolved
ATA 6330

Part: ISOLATION MOUNT — DEFECTIVE (M/R XMSN)

MOUNT IS DEFECTIVE. MOUNT APPEARS TO BE "WEAK". A/C HAD A "GROUND BOUNCE". POSSIBLE DELAMINATION OF ELASTROMIC MATERIAL IS APPARENT. REPLACING THIS MOUNT WI TH "NEW" REMOVED THE GROUND BOUNCE.

Source: SDR W6HR9644
OTHER · 1996-09-30 Unresolved
ATA 6330

Part: ISOLATION MT — WORN EXCESS (M/R XMSN)

ISOLATION MOUNTIS WORN EXCESSIVELY. ELASTOMERIC MATERIAL IS SEPERATED FROM INNER THREADED BOSS WHERE ROD END IS THREADED INTO.

Source: SDR W6HR9640