N417DA

CIRRUS DESIGN CORP SR22T · 2023 · Fixed-wing single-engine · 1 engine · 5 seats · Valid Registration

Registered owner: SKYLARK HOLDINGS LLC, CA (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

25 reports on file, 1995-12-23 – 2000-10-24.

NO TEST · 2000-10-24 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 61,905 hrs · 56,107 cycles

EMERGENCY LIGHT AT R1 DOOR WON''T TEST. SWITCH BAD. REPLACED LIGHT ASSY.

Source: SDR DL72K002100
FLUID LOSS; WARNING INDICATION · 2000-09-15 Matched by certificate designator
ATA 7210

Part: HELICOIL — BACKED OUT (NR1 ENG G/B) · airframe 61,732 hrs · 55,897 cycles

NR 1 ENG WAS SHUT DOWN DURING CRUISE DUE TO ZERO OIL QTY AND LOW OIL PRESSURE. OCCURRED AT FL 200 WHEN WE LEVELED OFF. FOUND BUSHING/HELICOIL PULLED OUT OF GEARBOX AT LP6 DRAIN TUBE ABOVE OIL FILTER. REPLACED SAME, RAN ENGINE PER PFHB CKS GOOD.

Source: SDR DL72K001788
SMOKE/FUMES/ODORS/SPARKS · 2000-07-30 Matched by certificate designator
ATA 3320

Part: LIGHT — SHORTED (CABIN) · airframe 61,520 hrs · 55,618 cycles

VERY STRONG ODOR ELECTRICAL THROUGHOUT CABIN WITH NO ABNORMAL INDICATIONS IN COCKPIT. FOUND CEILING LIGHT AT 4F AT FAULT. REPLACED LIGHT ASSY.

Source: SDR DL72K001434
NO TEST · 2000-06-01 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 61,264 hrs · 55,286 cycles

EGRESS LIGHT OUT AT SEAT 7C. REPLACED EGRESS LIGHT ASSY.

Source: SDR DL72K001075
OTHER · 2000-05-01 Matched by certificate designator
ATA 3350

Part: BATTERY — INOPERATIVE (AIRSTAIR) · airframe 61,119 hrs · 55,087 cycles

AFT STAIR OVERHEAD E PATH LIGHT INOP. REPLACED BATTERIES, CHECKS NORMAL PER M/M.

Source: SDR DL72K000870
Earlier reports · 1995–1999 · 20 reports

1999

NO TEST · 1999-09-07 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (ROW 8-9)

EMERGENCY CEILING AREA WHITE LIGHT INOP. REPLACED BATTERY.

Source: SDR DL72K991987
MULTIPLE FAILURE · 1999-08-29 Matched by certificate designator
ATA 3411

Part: HOSE — LEAKING (RT INSTR PANEL)

CAPT AND F/O AIRSPEED AND ALTITUDE DISAGREES (30-50 KTS SLOWER ON F/O'S) 2,000 FT LWR ON F/O'S. WHEN F/O WENT TO ALTERNATE, IT TRIPPED THE CADC OFF LINE. CAPT'S NUMBERS APPEARED CORRECT, F/O'S APPEARED INCORRECT. FOUND STATIC LEAK AT FLEX HOSE TO ALT ALERT IND. REPLACED HOSE AND IND. REPLACED ADC. PUMP-UP PITOT-STATIC LEAK CK OK.

Source: SDR DL72K991922
SMOKE/FUMES/ODORS/SPARKS · 1999-08-27 Matched by certificate designator
ATA 2121

Part: FAN — FAILED (A/C COMPT)

STRANGE SMELL, STRONG AT TIMES COMING FROM PACKS IN FLT. PACK TEMPS REMAINED NORMAL, SMOKE ID/RMVL CHECLIST WAS RUN TO COMPLETION. NO SMOKE WAS VISIBLE JUST ODOR. REPLACED GASPER FAN.

Source: SDR DL72K991916
SMOKE/FUMES/ODORS/SPARKS · 1999-06-10 Matched by certificate designator
ATA 3350

Part: RELAY — OVERHEATED (COCKPIT)

JUST PRIOR TO PUSHBACK DETECTED SLIGHT ODOR AFTER ENGINE START. CYCLED PACKS AND GASPER FAN ODOR GOT PROGRESSIVELY WORSE, SEEMED CONFINED TO THE COCKPIT. ISOLATED SMELL TO COCKPIT CEILING. FOUND EMERGENCY EXIT SIGN RELAY BAD. REPLACED SAME, NO OTHER FAULTS FOUND. EMERGENCY EXIT SIGNS CHECK NORMAL.

Source: SDR DL72K991311
OTHER · 1999-05-23 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (BS 580-600)

LFEC INSPECTION OF THE STRINGER 26L SKIN LAP SPLICE BETWEEN FS 360 AND 640 INDICATED CRACKS IN THE LOWER FASTENER ROW OF THE LOWER SKIN. INTERNAL HFEC INSPECTION CONFIRMED ONLY 2 CRACKS BETWEEN FS 580 AND 600. THE CRACKS WERE ROUTED OUT OF THE SKIN LAP AND REPAIRED WITH AN EXTERNAL ALUMINUM DOUBLER PER ER/A 367428-14AD, REV A.

Source: SDR DL72K991158
NO TEST · 1999-03-25 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (L2 DOOR)

L2 EMERGENCY LIGHTS INOP. REPLACED BATTERY PACK, OPS CKS GOOD.

Source: SDR DL72K990661
OTHER · 1999-02-22 Matched by certificate designator
ATA 5313

Part: STRINGER — CRACKED (BS 950)

STRINGER 29R CRACKED INCHES AFT OF STA 950E. DAMAGED STRINGER WILL BE TRIMMED OUT AND A NEW SECTION SPLICED IN. ACTION TAKEN, ERA 332797-14.

Source: SDR DL72K990382
OTHER · 1999-02-22 Matched by certificate designator
ATA 5330

Part: SKIN — GOUGED (L1 DOORWAY)

FUSELAGE SKIN GOUGED JUST FWD OF L1 DOOR AT THE STRINGER 10L LAP SPLICE. GOUGE MEASURED 1 X 1. ACTION TAKEN, ERA 332816-14.

Source: SDR DL72K990381
OTHER · 1999-02-22 Matched by certificate designator
ATA 5713

Part: STRINGER — CRACKED (WS 629)

RT UPPER WING STRINGERS 13 AND 14 AT WS 629. CRACKED STRINGER TO RIB TAB. ACTION TAKEN, ERA 332815-14AD.

Source: SDR DL72K990383
OTHER · 1999-02-19 Matched by certificate designator
ATA 5720

Part: VENT BOX — CRACKED (BS 686.5)

FWD VENT BOX CRACKED AT AFT EAR TO RIB STA 686.5 ATTACH PT. CUT OUT ACCESS HOLE PER MM 57-13-0, FIG 803. DRILLED AFT AND FWD ANGLE ASSY AND RADIUS FILLER. HFEC CRACK, FOUND CRACK, RUNS FROM BOLT HOLE AFT AND OUTWARD TO EDGE OF FLANGE. DRILLED RADIUS FILLERS PER MM 57-13-0, DRILLED ACCESS COVER. INSTALLED RADIUS FILLERS, FWD ANGLE AND COVER ASSY PER MM 57-13-0 804.

Source: SDR DL72K990333

1997

OTHER · 1997-12-23 Matched by certificate designator
ATA 5310

Part: STRUCTURE — CRACKED (BS 1263-1273)

THE RT TORQUE BOX STRUCTURE IN THE VENTRAL STAIRWAY WAS FOUND TO THREE CRACKED MEMBERS. THE FS 1263 BEAM WAS FOUND WITH A 1.0 CRACK AND THE FS 1273 BEAM AND GUSSET WERE FOUND WITH 1.0 CRACKS. THE DAMAGED MEMBERS WERE REPLACED PER BAC S/B 727-53-0129 AS DOCUMENTED IN ER/A 363537-14AD.

Source: SDR DL72K972719
OTHER · 1997-12-22 Matched by certificate designator
ATA 5754

Part: RIB — CRACKED (NR 7 LE SLAT)

FOUND ON B2 LETTER CHECK, 1.25 INCH CRACK IN RADIUS OF NOSE RIB I/B SIDE OF ACTUATOR ATTACH NR 7 SLAT. REPAIRED PER MM 57-54-0.

Source: SDR DL72K972708
OTHER · 1997-12-22 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (L 1 DOORWAY)

FOUND DURING B-2 LETTER CHECK, 1.25 INCH CRACK FUSELAGE SKIN AT MAIN ENTRY DOOR UPPER HINGE CUTOUT. REPAIRED PER SRM 53-30-3 FIG 33, TIME LIMITED.

Source: SDR DL72K972705
OTHER · 1997-12-22 Matched by certificate designator
ATA 5414

Part: SKIN — CRACKED (S-DUCT HOUSING)

FOUND ON B2 LETTER CK, SEVERAL .25 INCH CRACKS 'S' DUCT HOUSING FWD OF ACCESS PANEL 9501 RT SIDE. REPAIRED PER MM 54-30-0.

Source: SDR DL72K972707
OTHER · 1997-12-22 Matched by certificate designator
ATA 2782

Part: BRACKET — CRACKED (NR 1 SLAT ACT)

FOUND ON B2 LETTER CK, 1 INCH VISIBLE CRACK NR 1 SLAT ACTUATOR O/B ATTACH BRACKET. REPAIRED PER MM 57-20-21.

Source: SDR DL72K972706
OTHER · 1997-12-22 Matched by certificate designator
ATA 5313

Part: STRINGER — CRACKED (BS 942)

A 1.5 INCH CRACK IN LWR RADIUS OF STR 18A. REPAIRED PER MM 53-12-0 PG 820.

Source: SDR DL72K972717

1996

OTHER · 1996-10-01 Matched by certificate designator
ATA 5400

Part: S-DUCT WEB — CRACKED (NR 2 ENGINE)

DURING ACCOMPLISHMENT OF EO 4-59253-12 OPN 0120, FOUND .5 INCH VISIBLE CRACK IN LOWER LT CORNER OF VERTICAL WEB CROSSING NR 2 ENG INLET S-DUCT AT STA 1303. STOP DRILLED CRACK PER SRM 53-10-4 PG 65, INSTALLED DOUBLER PER SRM 53-10-4.

Source: SDR DL72K962292
OTHER · 1996-10-01 Matched by certificate designator
ATA 5320

Part: FITTING — CORRODED (BS 740)

CORROSION AT STA 740 BETWEEN STR 28R AND 29R AT SKIN SUPPORT FITTING. REPLACED FITTING PER MM 53-11-0 PG 858.

Source: SDR DL72K962236

1995

NO TEST · 1995-12-28 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

EMERGENCY LIGHTING INOP OVER L-2 DOOR. ITEM FOUND DURING MTC LAYOVER. REPLACED BATT PACK AND ALL OPS NORMAL.

Source: SDR DL72K954796
OTHER · 1995-12-23 Matched by certificate designator
ATA 5320

Part: TRANSVERSE BEAM — CRACKED (BS 1263)

THERE IS A 1.5 INCH CRACK IN THE AFT GUSSET AND FWD TRANSVERSE BEAM OF THE RT TORQUE BOX AT FS 1263. THESE AREAS OF THE TORQUE BOX ARE THE SUBJECT OF AIRWORTHINESS DIRECTIVE 94-07-08 WHICH REQUIRES INSPECTION PER S/B 53-0129. THIS REPLACEMENT DOES NOT TERMINATE THE REPETITIVE INSPECTION REQUIREMENTS. TERMINATING ACTION WILL BE PROVIDED BY EO 4-61071-3.

Source: SDR DL72K961612