N43XA

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

27 reports on file, 2006-04-16 – 2014-11-21.

WARNING INDICATION · 2014-11-21 Matched by certificate designator
ATA 2810

Part: FUEL TANK — CONTAMINATED · airframe 55,048 hrs · 28,881 cycles

BOTH FUEL FLOW AND N1 +/- 2 PERCENT IN CRUISE LT FUEL FLOW ON 4 OCCASIONS FLUCTUATED 10 PERCENT. SUSPECTED FUEL CONTAMINATION, SUMPED ALL FUEL TANKS FOUND EVIDENCE EXCESSIVE WATER IN TANKS. DRAINED ALL FUEL TANKS SUMPED TANKS AGAIN FOR COMPLETION OF TANK DRAIN. REFUELED ACFT RESUMPED ALL TANKS WITH NO EVIDENCE OF WATER FOUND. ACFT HAS SINCE OPERATED WITH NO FURTHER DIFFICULTIES. NOTIFIED FUEL COMPANIES AT LAST 3 FUELING LOCATIONS. ALL REPORTED CHECKING TRUCKS, TANKS AND OTHER ACFT WITH NO DISCREPANCIES OR WATER FOUND IN ANY SAMPLES.

Source: SDR BJNA2015F00004
Earlier reports · 2006–2013 · 26 reports

2013

OTHER · 2013-11-15 Matched by certificate designator
ATA 5730

Part: SKIN — CORRODED (ZONE 500) · airframe 53,301 hrs · 28,035 cycles

CORROSION FOUND ON THE TOP OF BOTH WING SKIN LEADING EDGES AT THE PYLON/ENGINE STRAP AREA THAT WERE OUT OF THE SRM LIMITS. ENGINEERING SUPPLIED A REPAIR SCHEME, MESSAGE NR CIN-CIN-13-0017-08B AND CIN-CIN-13-0016-13B, IN WHICH THE REPAIR WAS ACCOMPLISHED.

Source: SDR 2013FA0000633
FLT CONT AFFECTED · 2013-10-10 Unresolved
ATA 5330

Part: SKIN — DENTED (BS 727G-747) · airframe 53,301 hrs · 28,035 cycles

RIGHT LOWER AFT FUSELAGE HAS A DENT BETWEEN BS 727G-747 STINGERS 23-24R. CUT OUT DAMAGED SKIN, REMOVED EXISTING DOUBLER AND CUT OUT DAMAGED SKIN. HFC INSPECTED CUTOUT AREA. FABRICATED EXTERNAL DOUBLER AND INSTALLED IAW SRM 53-00-01, REPAIR 31, DETAIL VIII, FIGURE 201 PLUS SRM 51-20-01, 51-40-02.

Source: SDR EB1R201403130001

2012

NO TEST · 2012-06-05 Matched by certificate designator
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHT)

R2 DOOR EMERGENCY EXTERIOR EXIT LIGHT OUT. R & R R2 DOOR EMERGENCY EXTERIOR EXIT LIGHT IAW AMM 33-51-22. OPS CHECKED GOOD.

Source: SDR BJNA2012060150001
OTHER · 2012-05-16 Matched by certificate designator
ATA 3610

Part: DUCT — UNSERVICEABLE (PAC BAY)

ACFT WAS PERFORMING A NON-ROUTINE FLIGHT OPERATION AFTER A HEAVY MX VISIT, ACFT PRESSURIZATION BECAME UNCONTROLLABLE. ACFT RETURN TO DEPARTURE AIRPORT. MX FOUND A FLEX DUCT BETWEEN CONDENSER & ACM ON RT PACK DUCT THAT FAILED AND WAS LEAKING (REF AIPC 21-51-18-06-310). FLEX DUCT WAS REPLACED IAW AMM 21-51-11. ACFT WAS PRESSURIZED AND LEAK CHECKED SYS GOOD IAW AMM. ALL PARAMETERS WERE MET.

Source: SDR BJNA201205160001
OTHER · 2012-01-19 Matched by certificate designator
ATA 2560

Part: BATTERY — DISCHARGED (FLASHLIGHT)

AFT RT INBD EMERGENCY FLASHLIGHT BATTERY DISCHARGED. R & R EMERGENCY FLASHLIGHT BATTERY.

Source: SDR BJNA2012011900101

2011

OTHER · 2011-09-26 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHT)

OVERWING EMERGENCY EXIT LIGHT WILL NOT STAY ON. R & R THE OVER WING EMERGENCY EXIT LIGHT BATTERY PACK IAW AMM 33-51-51.

Source: SDR BJNA20110926001
OTHER · 2011-04-21 Matched by certificate designator
ATA 2560

Part: BATTERY — INOPERATIVE (FLASHLIGHT)

AFT LT INBD EMERGENCY FLASHLIGHT CHARGE WEAK. R & R AFT F/A FLASHLIGHT BATTERY IAW AMM 33-51-02.

Source: SDR BJNA110402

2010

OTHER · 2010-06-11 Matched by certificate designator
ATA 3350

Part: LAMP — BURNED OUT (EMERGENCY LIGHT)

EXTERIOR EMERGENCY EXIT LIGHT AT R1 DOOR INOPERATIVE. RELAMPED R1 DOOR SLIDE EMERGENCY LIGHT. OPS CK GOOD.

Source: SDR BJNA100601
OTHER · 2010-04-17 Matched by certificate designator
ATA 3350

Part: LAMP — BURNED OUT (EMERGENCY LIGHTS)

EMERGENCY AISLE LIGHT AT ROW 1 DEF, INOPERATIVE.

Source: SDR BJNA100401
OTHER · 2010-01-10 Matched by certificate designator
ATA 2560

Part: BATTERY — DISCHARGED (FLASHLIGHT)

FWD OTBD EMERGENCY FLASHLIGHT NOT CHARGING. REMOVED AND REPLACED BATTERY. OPS CK OK.

Source: SDR BJNA100103

2009

OTHER · 2009-12-30 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHTS)

SEVERAL EMERGENCY ISLE LIGHTS INOPERATIVE. REMOVED AND REPLACED THE EMERGENCY LIGHT BATTERY PACK. OPS CHECK GOOD.

Source: SDR BJNA091201
OTHER · 2009-12-30 Matched by certificate designator
ATA 3350

Part: LAMP — BURNED OUT (EMERGENCY LIGHTS)

EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BULB, OPS CHECK GOOD.(K)

Source: SDR BJNA091202
OTHER · 2009-10-11 Matched by certificate designator
ATA 3350

Part: LAMP — BURNED OUT (EMERGENCY LIGHT)

EMERGENCY LIGHT INOPEATIVE AT ROW 7. REMOVED AND REPLACED BULB IAW AMM 33-51-02. (K)

Source: SDR BJNA091001
OTHER · 2009-09-23 Matched by certificate designator
ATA 2560

Part: FLASHLIGHT — INOPERATIVE (CABIN)

AFT F/A FLASHLIGHT INOPERATIVE. REMOVED AND REPLACED THE FLASHLIGHT AND BATTERY. (K)

Source: SDR BJNA0900901
OTHER · 2009-07-21 Matched by certificate designator
ATA 3350

Part: LAMP — BURNED OUT (EMERGENCY LIGHT)

R1 DOOR EXTERIOR EMERGENCY SLIDE LIGHT INOPERATIVE. CARRIED OUT LAMP REPLACEMENT IAW AMM 33-51-22. OPS CHECK SATISFACTORY. (K)

Source: SDR BJNA090701
OTHER · 2009-06-17 Matched by certificate designator
ATA 3350

Part: LAMP — BURNED OUT (EMERGENCY LIGHT)

RT ROW 11 EMERGENCY LIGHT INOPERATIVE. REPLACE EMERGENCY AISLE LAMP IAW AMM 33-51-21. OPS CHECKS GOOD. (K)

Source: SDR BJNA090602
OTHER · 2009-06-17 Matched by certificate designator
ATA 3350

Part: LAMP — BURNED OUT (EMERGENCY LIGHT)

EXTERIOR EMERGENCY LIGHT AT R1 DOOR LOCATION INOPERATIVE. RELAMPED EMERGENCY LIGHT IAW AMM 33-51-02. OPS CHECK GOOD. (K)

Source: SDR BJNA090603
OTHER · 2009-06-17 Matched by certificate designator
ATA 3350

Part: LAMP — BURNED OUT (EMERGENCY LIGHTS)

EXTERIOR EMERGENCY LIGHT AFT OF LT WING LOCATION INOPERATIVE. REPLACED LAMP AT EXTERIOR LT WING LOCATION IAW AMM 33-51-02. OPS CHECK GOOD. (K)

Source: SDR BJNA090601
OTHER · 2009-04-27 Matched by certificate designator
ATA 5714

Part: SKIN — CORRODED (CENTER WING BOX)

TOP AFT LT CORNER OF THE CTR WING SKIN AT S-1C AND S-2C AT LBBL 60 TO 65 HAS CORROSION ON (3) SPOTS THAT ARE OUT OF THE LIMITS (0.080, 0.070, AND 0.050) OF THE MFG SRM. INSTALLED INTERNAL AND EXTERNAL DOUBLERS IAW AEROTECH STRUCTURES INC" 8110-3 APPROVED DWG R09-010-01 (INITIAL RELEASE) DATED APRIL 20, 2009. (K)

Source: SDR BJN2009F00000
OVER TEMP; WARNING INDICATION · 2009-01-29 Matched by certificate designator
ATA 4920

Part: APU — OVERHEATED

APU FIRE/OVHT LIGHT ILLUMINATED IN FLIGHT. QRH/MEMORY ITEMS FOLLOWED, BOTTLE DISCHARGED, FIRE/OVHT LIGHT EXTINGUISHED. INSPECTION FOUND HEAT DAMAGE TO OVHT/FIRE DETECTION WIRING AND POSSIBLE TURBINE WHEEL FAILURE. REMOVED AND REPLACED APU. FAILURE ANALYSIS - PROBABLE CAUSES ARE DEFECTIVE TEMPERATURE CONTROL SYS/ INCORRECT TURBINE BEARING SLEEVE INSTALLED, WHICH WOULD RESULT IN EXCESSIVE VIBRATION FOLLOWED BY CONTACT OF THE TURBINE WHEEL AND SHROUD. (K)

Source: SDR BJNA090101

2008

NO TEST · 2008-10-19 Unresolved
ATA 3350

Part: LAMP — BURNED OUT (EMERGENCY LIGHT)

LT FORWARD EXTERIOR OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. RE-LAMPED EMERGENCY EXIT LIGHT IAW AMM 33-51-22.

Source: SDR BINA081001
FLT CONT AFFECTED · 2008-04-02 Matched by certificate designator
ATA 2730

Part: ACTUATOR — MALFUNCTIONED (ELEVATOR)

STABILIZER TRIM WOULD NOT KEEP UP WITH THE COMMANDED POSITION, ASSOCIATED WITH A STAB OUT OF TRIM ANNUNCIATION. STABILIZER TRIMMED "UP" OK. REMOVED AND REPLACED STABILIZER JACK SCREW ASSEMBLY. OVERHAUL FOUND - P/N 54032-006 SCREW ASSEMBLY WORN; P/N 65C34615-1 SLEEVE OUT OF TOLERANCE; P/N 69-44011-8 GEAR OUT OF TOLERANCE; BEARINGS WORN REQUIRED REPLACEMENT; SPRING OUT OF TOLERANCE. (S)

Source: SDR BJNA080402
FLT CONT AFFECTED · 2008-04-02 Matched by certificate designator
ATA 2740

Part: JACKSCREW — DAMAGED (STABILIZER)

STABILIZER TRIM WOULD NOT KEEP UP WITH THE COMMANDED POSITION, ASSOCIATED WITH A STAB OUT OF TRIM ANNUNCIATION. STABILIZER TRIMMED (UP), OK. REMOVED AND REPLACED STABILIZER JACK SCREW ASSY. WAITING FOR TEAR DOWN REPORT ON REMOVED UNIT. (K)

Source: SDR BJNA032908002
OTHER · 2008-03-29 Matched by certificate designator
ATA 2220

Part: SPRING — BROKEN (ELEVATOR)

BJNA080401- ALTITUDE HOLD INTERMITTENT. FOUND ELEVATOR LOAD FEEL CENTERING SPRING (OUTER) BROKEN. REMOVED AND REPLACED ELEVATOR LOAD FEEL CENTERING SPRINGS (INNER AND OUTER). (K)

Source: SDR BJNA032908001
OTHER · 2008-02-28 Matched by certificate designator
ATA 2560

Part: BATTERY — DISCHARGED (FLASHLIGHT)

F/A EMERGENCY FLASHLIGHT BATTERY DISCHARGED. REMOVED AND REPLACED THE EMERGENCY FLASHLIGHT BATTERY. (K)

Source: SDR BJNA080201

2006

NO TEST · 2006-04-16 Matched by certificate designator
ATA 3350

Part: WIRE — BROKEN (CABIN)

ROW 13, EMERGENCY EXIT LIGHT INOPERATIVE. REPAIRED BROKEN SPLICE IAW STANDARD WIRING PRACTICES MANUAL REF 20-10-13. (K)

Source: SDR BJNA060401