N445AE
Registered owner: AIR EVAC EMS INC, MO (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| Air Evac EMS, Inc. (EVCA) | Certificate holder | — | Matched by certificate designator |
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
5 reports on file, 1997-06-02 – 2023-03-03.
Part: ATTACH FITTING — CRACKED (L/H UPPER TB FIT) · airframe 4,396 hrs · 8,005 cycles
CRACK FOUND IN L/H UPPER ATTACHMENT TAILBOOM FITTING P/N 206-032-409-001P DURING 50 HOUR INSPECTION
Part: BULKHEAD — CRACKED (FUSELAGE) · airframe 2,878 hrs · 9,290 cycles
DURING PERIODIC INSPECTION, FOUND TAILBOOM ATTACHMENT BULKHEAD CRACKED AT UPPER LH INTERCOSTAL.
Part: STIFFENER — CRACKED (ZONE 100) · airframe 2,310 hrs · 10,514 cycles
RT AFT STIFFENER IN CENTER POST HAS A 2 INCH CRACK ACROSS THE STIFFENER APPROXIMATELY AT WATERLINE 67, RIGHT BL 5 AND STATION 82. RT WEB HAS 1 INCH CRACK IN SAME LOCATION. REMOVED AND REPLACED RT AFT BROOM CLOSET ANGLE P/N 206-033-110-239S AND REPAIRED CRACK R/H BROOM CLOSET SKIN IAW SRM. NO DEFECTS NOTED
Part: RIB — CRACKED (RT WING)
DURING A PHASE INSPECTION, FOUND THE CRACK IN THE RIGHT CANTED RIB HAD PROGRESSED BEYOND THE PREVIOUSLY INSTALLED STOP DRILLS. AIRCRAFT WAS RETURNED TO THE OPERATOR WITH A ''FERRY PERMIT'' FOR REPAIR. (X)
Part: ARMATURE — DAMAGED (START/GENERATOR)
WHILE APPROACHING TO LAND AT 'LAS', PILOT LOST LT GENERATOR INDICATION. TWO MINUTES LATER PILOT GOT A FIRE WARNING INDICATION AND SECURED THE ENGINE AND FIRED THE LT FIRE BOTTLE. LANDED WITH NO FURTHER PROBLEMS. EXAMINATION FOUND THE GENERATOR SHAFT SHEARED AND ARMATURE DAMAGED. BEARINGS WERE INTACT AND CASE OF GENERATOR SHOWED SIGNS OF OVERHEATING. NO OTHER DAMAGE FOUND. INSTALLED SERVICEABLE GENERATOR AND FIRE BOTTLE. SYSTEMS CHECKED GOOD.