N474LF

EUROCOPTER DEUTSCHLAND GMBH MBB-BK 117 C-2 · 2009 · Rotorcraft · 2 engines · 8 seats · Valid Registration

Registered owner: WEST PENN ALLEGHENY HEALTH SYSTEM INC, PA (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
METRO AVIATION, INC (HDNA)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

3 reports on file, 2014-09-25 – 2026-02-10.

OTHER · 2026-02-10 Matched by certificate designator
ATA 5320

Part: BRACKET — CRACKED (ZONE 100) · airframe 6,321 hrs · 21,871 cycles

CRACK FOUND ON LOWER FUSELAGE BRACKET, STATION 2597.

Source: SDR 2026FA0000093
OTHER · 2015-02-11 Matched by certificate designator
ATA 5311

Part: FRAME — CRACKED (FUSELAGE) · airframe 1,135 hrs

CRACK FOUND DURING INSPECTIONS IN TAIL CONE ON FRAME AT STATION X6616 3 O'CLOCK POSITION LOOKING IN TAIL CONE. REPAIR COMPLETED IAW FORM 8110-3 AHI15-026 DATED 1-29-2015, HELICOPTERS GMBH FORM ESDM-09 01-02, RDAS-AHI1500102 REV C DATED 01-29-2015, REPAIR DOCUMENT AHI2015-0003 REV A DATED 01-14-2015.

Source: SDR HDNA201502110003
FLT CONT AFFECTED · 2014-09-25 Matched by certificate designator
ATA 6700

Part: ACTUATOR — FAILED (DUPLEX CYCLIC) · airframe 953 hrs · 3,352 cycles

DUPLEX CYCLIC TRIM ACTUATOR FAILED INFLIGHT CAUSING UNWANTED FORCE TO CONTROLS.

Source: SDR HDNA2014092600160