N47962
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| Skymates Inc. | Operator | on 2005-06-10 | Operator named in NTSB report |
Accident & incident history
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
2 reports on file, 1997-02-19.
Part: CONTROL CABLE — FRAYED (RT WING)
REMOVED PANEL AT FLAP OUTBOARD HINGE AREA. INSPECTED AFT CABLE FOR WEAR WHERE IT GOES OVER ANTI-CHAFE BOX. THIS IS SECOND AIRCRAFT THAT AILERON CABLE WAS FOUND FRAYED AT THIS POINT.
Part: CONTROL CABLE — FRAYED (RUDDER)
RUDDER CABLES ARE FRAYING IN AFT BULKHEAD ON TOP OF PULLEYS. YOU MUST MOVE RUDDER IN OPPOSITE DIRECTION AND FEEL FWD AND AFT OF PULLEY TO DETERMINE IF CABLE IS FRAYED. IN SOME CASES, THIS IS NOT A GUARANTEE THAT IT IS NOT FRAYED.